PeakTech 1635 Digital Clamp Meter User Manual
- June 3, 2024
- PeakTech
Table of Contents
PeakTech 1635 Digital Clamp Meter User Manual
Safety Precautions
This product complies with the requirements of the following directives of the
European Union for CE conformity: 2014/30/EU (electromagnetic compatibility),
2014/35/EU (low voltage), 2011/65/EU (RoHS).
Overvoltage category III 600V; pollution degree 2.
CAT I: For signal level, telecommunication, electronic with small transient
over voltage
CAT II: For local level, appliances, main wall outlets, portable equipment
CAT III: Distribution level, fixed installation, with smaller transient over-
voltages than CAT IV.
CAT IV: Units and installations, which are supplied overhead lines, which are
stand in a risk of persuade of a lightning, i.e. main-switches on current
input, over-voltage-diverter, current use counter.
To ensure safe operation of the equipment and eliminate the danger of serious
injury due to short-circuits (arcing), the following safety precautions must
be observed.
Damages resulting from failure to observe these safety precautions are exempt
from any legal claims whatever.
- Do not use this instrument for high-energy industrial installation measurement
- Do not exceed the maximum permissible input ratings (danger of serious injury and/or destruction of the equipment).
- Comply with the warning labels and other info on the equipment.
- To avoid electric shock, do not operate this product in wet or damp conditions. Conduct measuring works only in dry clothing and rubber shoes, i. e. on isolating mats.
- Always start with the highest measuring range when measuring unknown values.
- Do not subject the equipment to direct sunlight or extreme temperatures, humidity or dampness.
- Do not subject the equipment to shocks or strong vibrations.
- Do not operate the equipment near strong magnetic fields (motors, transformers etc.).
- Keep hot soldering irons or guns away from the equipment.
- Allow the equipment to stabilize at room temperature before taking up measurement (important for exact measurements).
- Do not input values over the maximum range of each measurement to avoid damages of the meter.
- Replace the battery as soon as the battery indicator “BAT” appears. With a low battery, the meter might produce false reading that can lead to electric shock and personal injury.
- Fetch out the battery when the meter will not be used for long period of time.
- Periodically wipe the cabinet with a damp cloth and mid detergent. Do not use abrasives or solvents.
- The meter is suitable for indoor use only
- Do not operate the meter before the cabinet has been closed and screwed safely as terminal can carry voltage.
- Do not store the meter in a place of explosive, inflammable substances.
- Do not modify the equipment in any way
- Opening the equipment and service – and repair work must only be performed by qualified service personnel
- Do not operate the equipment unattended.
Cleaning the cabinet
Clean only with a damp, soft cloth and a commercially available mild household cleanser. Ensure, that no water gets inside the equipment to prevent possible shorts and damage to the equipment.
Safety symbols
Double insulation, protection class II
Attention! Refer to the manual
Input limits
Function | Input limits |
---|---|
ACA | 80A |
DCA | ±80A |
Introduction
Unpacking and inspection
Unpon removing your new Clamp Meter from it´s packing, you should have the following items:
- Clamp meter
- Carrying case
- Instruction manual
Specifications
General Specifications
Display: 3 2/3-digit LC-Display, max. reading 2400
Polarity: automatic Polarity indication
Auto power off: after approx. 7 minutes
Overrange: “OL” or “-OL” is displayed indication
Measuring rate: 2 x per second, nominal
Type of sensing: Hall-effect-sensing for AC and DC
Low battery: “BAT” is displayed when battery voltage drops
indication: below the operating voltage
Max. Altitude: 3000 m
Installation: IEC 61010-1; CAT III 600 V, UL 1244 category
Operating temp: -10°C…+50°C (+14°F…+122°F)
Storage temp: -30°C…+60°C (-14°F…+140°F)
Power Supply: 2 x 1,5 V AAA
Max. Conductor: 18 mm size
Dimensions: 65 x 164 x 32 mm
Weight: 180 g
Accessories: Battery Carrying case Instruction manual
Electrical Data
Accuracy is + (% reading + number of digits) at 23 + 5°C and a humidity of < 90%.
Function | Range | Resolution | Accuracy |
---|---|---|---|
DCA | 0 … 2 A | 1mA | ± (2,8% + 8 dgt.) |
2 … 80 A | 100mA | ||
ACA | 0 … 2 A | 1mA | ± (3,0% + 8 dgt.) |
2 … 80 A | 100mA | ||
Frequency range | 50/60 Hz |
Non-contact voltage
detect
| 100 … 600 V AC|
Auto Power Off
The Meter will automatically shut itself off after approx. 7 minutes after power on.
Data Hold
To freeze the LCD meter reading, press the Data-Hold button. While data hold
is active, the HOLD display icon appears on the LCD.
Press the Data-Hold button again to return to normal operation.
Note:
The HOLD feature will activate when the backlight is turned on.
Press HOLD key again to exit HOLD.
Backlight
The Backlight function illuminates the display and is used, when the ambient
light is too low to permit viewing on the display readings.
Press the HOLD button for < 2 seconds to turn the backlight on and press
button again to turn the backlight off.
Zero button
For DCA Zero & Offset adjustment.
Voltage detector
Intended to check for the presence of AC mains voltage, signalling the user with a flashing red LED.
Flash light
- Press the red button on the upper side of the meter, a white flash will come out from the lighter near the clamp. It can be used for illumination.
- Release the button, the light will off.
Front panel
- Current clamp
- Flash light button
- Rotary function switch
- Data Hold and backlight button
- LCD-Display
- Clamp trigger
- Zero button
Display
(1)| AC DC| AC
DC
---|---|---
(2)| –| Minus-sign
(3)| HOLD| DATA-Hold
(4)| BAT| Low battery indication
Operation
AC Current measurement
- Set the function switch to the measuring range 2 A or 80 A AC
- Press the trigger to open the transformer jaws and clamp one conductor only, make sure, that the jaw is firstly closed around the conductor, then read the reading from digital display.
DC Current measurement
- Set the function switch to the measuring range 2 A or 80 A DC
- Full compensate the residual magnetism by pressing Zero-key.
- Press the trigger to open the transformer jaws and clamp one conductor only, make sure, that the jaw is firstly closed around the conductor, then read the reading from digital display.
Battery replacement
Use the following procedure to replace the battery:
- Turn the instrument power off.
- Place the instrument face-down and remove the screw of battery compartment.
- Remove the battery cover and remove the batteries.
- Install new batteries and refit battery cover.
Notification about the Battery Regulation
The delivery of many devices includes batteries, which for example serve to
operate the remote control. There also could be batteries or accumulators
built into the device itself. In connection with the sale of these batteries
or accumulators, we are obliged under the Battery Regulations to notify our
customers of the following:
Please dispose of old batteries at a council collection point or return them
to a local shop at no cost. The disposal in domestic refuse is strictly
forbidden according to the Battery Regulations. You can return used batteries
obtained from us at no charge at the address on the last side in this manual
or by posting with sufficient stamps.
Contaminated batteries shall be marked with a symbol consisting of a crossed-
out refuse bin and the chemical symbol (Cd, Hg or Pb) of the heavy metal which
is responsible for the classification as pollutant:
- “Cd” means cadmium.
- “Hg” means mercury.
- “Pb” stands for lead.
You can obtain further information about the Battery Regulations from the Bundesministerium für Umwelt, Naturschutz und Reaktorsicherheit (Federal Ministry of Environment, Nature Conservation and Reactor Safety).
All rights, also for translation, reprinting and copy of this manual or parts are reserved. Reproductions of all kinds (photocopy, microfilm or other) only by written permission of the publisher.
This manual is according the latest technical knowing. Technical alterations reserved.
We herewith confirm that the units are calibrated by the factory according to the specifications as per the technical specifications.
We recommend to calibrate the unit again, after 1 year.
© PeakTech® 01/2022 JTh/Ehr/Lie
PeakTech Prüf- und Messtechnik GmbH
– Gerstenstieg 4 – DE-22926 Ahrensburg / Germany
+49-(0) 4102-97398-80 +49-(0) 4102-97398-99
info@peaktech.de
www.peaktech.de