CDC-41552-JX1A Pressure Injectable Arrowg+ard Blue Advance Two-Lumen JACC Instructions

September 3, 2022
Arrow

CDC-41552-JX1A Pressure Injectable Arrowg+ard Blue Advance Two-Lumen JACC

Contents:

  • Two-Lumen TaperFree® Catheter with Arrowg+ard Blue Advance®
  • Antimicrobial/Antithrombogenic Protection1: 5.5 Fr. (1.86 mm OD) x 15 cm, Pressure Injectable, Blue FlexTip®
  • GlideThru™ Peel-Away Sheath: 5.5 Fr. x 2-3/4″ (7 cm) Radiopaque over 5.5 Fr. Dilator
  •  Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – Straight Stiff Tip on Other) with Arrow Advancer
  •  Catheter: 20 Ga. x 1-3/4″ (4.50 cm) over 22 Ga. Safety Introducer Needle
  •  Injection Needle: Eclipse™2 25 Ga. x 1-1/2″ (3.81 cm) RW
  • Safety Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
  •  Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
  •  Syringe: 5 mL Luer-Lock
  •  Syringe: 5 mL Luer-Slip
  •  Skin Protectant Prep
  •  5 mL 1% Lidocaine HCl Solution and Alcohol Prep
  •  3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™ Tint
  • Dust Cap: Non-Vented
  •  SecondSite™ Adjustable Hub: Fastener
  •  SecondSite™ Adjustable Hub: Catheter Clamp
  •  SharpsAway® Disposal Cup
  •  SharpsAway® II Locking Disposal Cup
  •  Towel: 24″ x 36″ (61 cm x 91 cm)
  • Maximal Barrier Drape™ with 4″ fenestration Towel
  • Safety Scalpel: #11
  • Checklist/CLIP Sheet
  • Sterile Procedure Sign
  •  Patient Information Booklet
  •  Medication Label: 1% Lidocaine
  •  Paper Tape Measure
  •  Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
  •  Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
  •  Dressing: Tegaderm®4 15.5 cm x 10 cm
  •  Surgical Apparel: Impervious Gown
  •  Dressing: BIOPATCH®5
  •  Dressing: STATLOCK®6 CV Plus Catheter Stabilization Device
  • Surgical Apparel: Mask with Eye Shield
  • Surgical Apparel: Bouffant Cap
  • Surgical Apparel: Mask
  • Transducer Cover: 5″ x 48″ (13 cm x 122 cm) with Sterile Gel
  •  HemoHopper® Fluid Receptacle
  • Licensed under US Patent No. 7,329,412.
  • 2A trademark of Becton, Dickinson and Company.
  • 3A registered trademark of CareFusion or one of its subsidiaries.
  • 4A registered trademark of 3M Company.
  • 5A registered trademark of Johnson & Johnson Corporation.6A registered trademark of C. R. Bard, Inc.

Not made with natural rubber latex
Store between 20 – 25°C (68 – 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.

Contraindications:
The Arrowg+ard Blue Advance antimicrobial/anti-thrombogenic catheter is contraindicated for patients with known hypersensitivity to chlorhexidine.

  • Distal (18 Ga.)
  • Proximal (18 Ga.)

 Priming volumes are approximate and are done without accessories

  •  Flow rate values are approximate and are determined using deionized water at 100 cm head height.
  • Pump flow rates are determined at a maximum pump pressure of 10 psig and represent approximate flow capabilities.
  • Pressure injection flow rates are determined using media of 11.8 centipoises (cP) viscosity, with 152 cm administration set tubing.

Read User Manual Online (PDF format)