CDC-41552-JX1A Pressure Injectable Arrowg+ard Blue Advance Two-Lumen JACC Instructions

June 4, 2024
Arrow

CDC-41552-JX1A Pressure Injectable Arrowg+ard Blue Advance Two-Lumen

JACCCDC-41552-JX1A-Pressure-Injectable-Arrowg-ard-Blue-Advance-Two-Lumen-
JACC-product

Contents:

  • Two-Lumen TaperFree® Catheter with Arrowg+ard Blue Advance®
  • Antimicrobial/Antithrombogenic Protection1: 5.5 Fr. (1.86 mm OD) x 15 cm, Pressure Injectable, Blue FlexTip®
  • GlideThru™ Peel-Away Sheath: 5.5 Fr. x 2-3/4″ (7 cm) Radiopaque over 5.5 Fr. Dilator
  •  Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – Straight Stiff Tip on Other) with Arrow Advancer
  •  Catheter: 20 Ga. x 1-3/4″ (4.50 cm) over 22 Ga. Safety Introducer Needle
  •  Injection Needle: Eclipse™2 25 Ga. x 1-1/2″ (3.81 cm) RW
  • Safety Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
  •  Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
  •  Syringe: 5 mL Luer-Lock
  •  Syringe: 5 mL Luer-Slip
  •  Skin Protectant Prep
  •  5 mL 1% Lidocaine HCl Solution and Alcohol Prep
  •  3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™ Tint
  • Dust Cap: Non-Vented
  •  SecondSite™ Adjustable Hub: Fastener
  •  SecondSite™ Adjustable Hub: Catheter Clamp
  •  SharpsAway® Disposal Cup
  •  SharpsAway® II Locking Disposal Cup
  •  Towel: 24″ x 36″ (61 cm x 91 cm)
  • Maximal Barrier Drape™ with 4″ fenestration Towel
  • Safety Scalpel: #11
  • Checklist/CLIP Sheet
  • Sterile Procedure Sign
  •  Patient Information Booklet
  •  Medication Label: 1% Lidocaine
  •  Paper Tape Measure
  •  Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
  •  Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
  •  Dressing: Tegaderm®4 15.5 cm x 10 cm
  •  Surgical Apparel: Impervious Gown
  •  Dressing: BIOPATCH®5
  •  Dressing: STATLOCK®6 CV Plus Catheter Stabilization Device
  • Surgical Apparel: Mask with Eye Shield
  • Surgical Apparel: Bouffant Cap
  • Surgical Apparel: Mask
  • Transducer Cover: 5″ x 48″ (13 cm x 122 cm) with Sterile Gel
  •  HemoHopper® Fluid Receptacle
  • Licensed under US Patent No. 7,329,412.
  • 2A trademark of Becton, Dickinson and Company.
  • 3A registered trademark of CareFusion or one of its subsidiaries.
  • 4A registered trademark of 3M Company.
  • 5A registered trademark of Johnson & Johnson Corporation.6A registered trademark of C. R. Bard, Inc.

Not made with natural rubber latex
Store between 20 – 25°C (68 – 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.

Contraindications:
The Arrowg+ard Blue Advance antimicrobial/anti-thrombogenic catheter is contraindicated for patients with known hypersensitivity to chlorhexidine.

  • Distal (18 Ga.)
  • Proximal (18 Ga.)

 Priming volumes are approximate and are done without accessories

  •  Flow rate values are approximate and are determined using deionized water at 100 cm head height.
  • Pump flow rates are determined at a maximum pump pressure of 10 psig and represent approximate flow capabilities.
  • Pressure injection flow rates are determined using media of 11.8 centipoises (cP) viscosity, with 152 cm administration set tubing.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Arrow User Manuals

Related Manuals