Danfoss CS Pressure Switch Installation Guide

October 27, 2023
Danfoss

Danfoss CS Pressure Switch

Danfoss-CS-Pressure-Switch-Installati

Mounting orientation (Fig. 1-3)
The pressure switch is connected to the pressure vessel. The pressure switches will operate regardless of their orientation, but to meet the enclosure requirements of IP43 and IP55, they must be mounted vertically with a connection downwards. The connection is self-supporting.

Main connection (Fig. 4)
Three-pole load

Main connection (Fig. 5)
Single-pole AC load

Main connection (Fig. 6)
Single-pole DC load

Contact load (Fig. 7)
3 contacts connected in series

Setting (Fig. 8)

  1.  Cut-off pressure screw (P)

  2.  Differential pressure screw (ΔP) Cut-off pressure graphs (Fig. 9)A – Turns of Pe screw
    Example
    A compressor is to be controlled by a CS pressure switch. The cut-in pressure is 3.5 bar and the cut-off pressure is 5 bar. The choice should be a CS with a range of 2–6 bars.

  3.  Turn the cut-off pressure screw (1) about 12 times, see cut-off pressure graphs.

  4.  Turn the differential screw (2) about 4.5 times, see CS 2–6 nomogram. Take a straight line from 5 bar cut-out pressure on the nomogram to the differential, 1.5 bar, and read off the number of turns, i.e. 4.5.

Differential pressure nomograms (Fig. 10)
A – No. of turns of Δp screw
NOTE! The system cannot be started if the differential setting is greater than the cut-off pressure. Check and if necessary set the differential at a smaller value (turn the Δp screw counterclockwise).

Drain hole (Fig. 11)
If because of large temperature variations there is a risk of condensate forming in the pressure switch, a screwdriver can be used to make a drain hole in the enclosure.
Fig. 12

  1.  Slide ring
  2.  Combi-screw
  3.  Screw
  4.  Cover
  5.  Spindle
  6.  Toggle arm
  7.  Snap spring
  8.  Snap arm
  9.  Switch housing assy
  10. Self-tapping screw
  11. Manual switch
  12. Base
  13. Grubscrew
  14.  Screw
  15. Pressure pad
  16.  Spring retainer
  17. Compression spring
  18.  Pressure shoe
  19. Diaphragm
  20.  Flange, G 1/4, G 1/2, 1/4-18 NPT
  21.  Cap
  22. Differential arm
  23.  Tension spring
  24.  Tension screw
  25.  Bracket
  26. Pressure gauge connection G 1/4 (Tightening torque: max. 16 Nm)