invt LSW-3 Stick Logger User Manual

June 3, 2024
invt

invt LSW-3 Stick Logger

invt-LSW-3-Stick-Logger-PRODUCT

Stick logger installation

  1. Step1: Assemble logger to the inverter communication interface as shown in the diagram.
  2. Step2: Install/Removeinvt-LSW-3-Stick-Logger- \(2\)

Operations and notices for Reset button

Operations and key-press descriptions for Reset button

invt-LSW-3-Stick-Logger- \(3\)

Notices for Reset button

Notice: Do not remove waterproof plug.

Set WiFi connection on PC

Notice: The setting hereinafter is operated with Windows XP for reference only. If other operating systems are used, please follow the corresponding procedures.

  1. Prepare a computer or device with WiFi, e.g. tablet PC and smartphone with WiFi function.
  2. Obtain an IP address automatically.
  3. Set WiFi connection to the logger.

Open wireless network connection and click View
Wireless Networks:invt-LSW-3-Stick-Logger- \(5\)

Select wireless network of the logger. The network name consists of AP and the serial number of the product. Input the password shown on the logger. Then click Connect.invt-LSW-3-Stick-Logger- \(6\)

Notice: If AP_(serial number of product) is not available in the wireless network list, there may be problems in the connection or setting of logger. Please wait several minutes to refresh the list or plug in the logger again.

Set parameters of logger

Open a web browser, and enter 10.10.100.254, then fill in username and password, both of which are admin as default.

Recommended browsers: Internet Explorer 8+, Google Chrome 15+, Firefox 10 +invt-LSW-3-Stick-Logger- \(7\)

In the Status page, you can view general information of the logger.invt-
LSW-3-Stick-Logger- \(8\)

Follow the setup wizard to start quick setting.

  • (a) Click Wizard to start. Select the wireless network you need to connect, then click Next.invt-LSW-3-Stick-Logger- \(9\)
    Notice: If the signal strength (RSSI) of the selected network is <15%, which means unstable connection, please adjust the antenna of the router, or use a repeater to enhance the signal. The SSID of your selected router network should be less than 30 characters, in which blank space should not be included.

  • (b) Enter the password for the selected network, select Enable to obtain an IP address automatically, then click Next.invt-LSW-3-Stick-Logger- \(10\)
    Notice: Router password cannot be recognized if it contains any character such as‘&’,‘#’,‘%’, and blank space. The password is being verified, please wait for a while. If you have entered an invalid password or encryption method, an error notice will pop up.

  • (c) Enhance security settings of the WiFi logger by selecting any options as listed, then click Next.invt-LSW-3-Stick-Logger- \(11\)

  • (d) If setting is successful, the following page will display. Click OK to restart.invt-LSW-3-Stick-Logger- \(12\)

  • (e) If restart is successful, the following page will display. If this page does not display automatically,please refresh your browser.invt-LSW-3-Stick-Logger- \(13\)

  • (f) Re-log in this setting page to Status page after the Web server restart, and check the network connection status of the logger.invt-LSW-3-Stick-Logger- \(14\)

Notice: After network setting is complete, the Wireless AP mode should be enabled and relative information of your router will display on the interface automatically. Besides the Remote server A should be connected.
If you meet any problems and need support, please provide the screenshot of the status page as shown below.invt-LSW-3-Stick-Logger-
\(15\)

Logger Status

Check Indicator light

invt-LSW-3-Stick-Logger- \(16\)

Normal operation status of the stick logger is as follows, when router connected to the network normally:

  1. Connection to server is successful: NET light keeps on after the logger powered on.
  2. Logger is running normally: READY light flashes.
  3. Connection to inverter is successful: COM light keeps on.

Troubleshooting

If the data on platform is abnormal when the stick logger is running, please check the status of indicator lights according to the table below for simple troubleshooting. If problems still cannot be solved or indicator lights status is different from the table below, please contact Customer Support.
( Note: Please wait for at leat 2 minutes after logger is powered on)

invt-LSW-3-Stick-Logger- \(17\)invt-LSW-3-Stick-
Logger- \(18\)

Warning: Please make sure the stick logger is working properly before you leave the site. If there is anything abnormal, please do not leave the site and contact customer service at the first time.

If you have any technical queries about our products, please contact us and provide the following information:

  1. Product model and serial number of stick logger.
  2. Product model and serial number of connected inverter.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals