invt GD800-91 Goodrive Series Active Rectifier Component Instruction Manual
- June 1, 2024
- invt
Table of Contents
- invt GD800-91 Goodrive Series Active Rectifier Component
- Product Information
- Product Usage Instructions
- Preface
- Product specifications
- Product nameplate
- Product model
- Product ratings
- Configuration list
- Electrical principle and wiring
- Product dimensions
- Contact Information
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
invt GD800-91 Goodrive Series Active Rectifier Component
Product Information
Specifications
- Function description: THDI < 5% (at the rated current), THDU < 5%
- Overload capacity: Light overload with 110% current lasting 1 minute every 5 minutes, heavy overload with 150% current lasting 1 minute every 5 minutes
- Working efficiency: 97%
- Power factor: > 0.99 (of the rated current)
- Relative humidity: Below 1000m altitude (Derating required above 1000m)
- Anti-vibration performance: Compliant with 3 M4 vibration level in GB/T4798.3
- IP rating: For the module: IP00
- Safety performance: Compliant with EN 61800-5-1
- Cooling method: Forced air cooling
- Protection function: Short circuit, overcurrent, overload, overvoltage, undervoltage, overtemperature, phase loss
Product Usage Instructions
-
Installation
Ensure installation is below 1000m altitude. Derate by 1% for every increase of 100m above this altitude. -
Power Connection
Connect AC input of 3PH 380V~480V 94A and output Vin*1.5~720Vdc as per the product nameplate. -
Operation
Operate within the specified overload capacities and efficiency to ensure optimal performance. -
Maintenance
Regularly check for any signs of short circuits, overcurrents, or other protection function alerts. Keep the unit clean and ensure proper ventilation for cooling.
Frequently Asked Questions (FAQ)
-
Q: What should I do if the unit overheats?
A: Ensure proper ventilation around the unit and check for any obstructions blocking airflow. If the issue persists, contact customer support for further assistance. -
Q: Can I operate the unit above 1000m altitude without derating?
A: It is not recommended to operate the unit above 1000m altitude without derating as it may affect the performance and efficiency of the product.
No. | Change description | Version | Release date |
---|---|---|---|
1 | First release. | V1.0 | October 2023 |
Preface
Thank you for choosing the INVT Goodrive880 series engineering variable- frequency drive (VFD). GD800-91 series are Goodrive880 series active rectifier products, which mainly consist of rectifier units, LCL filtering components, buffer components, lightning protection components, EMI components and voltage detection modules. You can purchase the components for system integration by yourselves.
This manual is the Goodrive880 series active rectifier component hardware manual, presenting safety precautions, product overview, configuration list, electrical principle and wiring, and product dimensions. Read through this manual carefully before installation to ensure the product is installed and operated properly to give full play to its excellent performance and powerful functions. If you have any questions about the function and performance of the product, please consult our technical support.
Product specifications
Table 1-1 Product specifications
Function description | Specifications |
---|
Basic performance
| AC input voltage| 400V, 3PH 380–440V AC±10% (-15% < 1min)
Input frequency| 50Hz or 60Hz; Allowed range: 47–63Hz
Unbalance| Less than ±3% of the rated interphase voltage
THE| THDI< 5% (at the rated current) THDU< 5%
Overload capacity
| Light overload: Overload with a current of 110% can last for 1 minute every 5 minutes, and overload with a current of 150% can last for 10 seconds every 5 minutes
Heavy overload: Overload with a current of 150% can last for 1 minute every 5 minutes, and overload with a current of 180% can
last for 10 seconds every 5 minutes
Working
efficiency
| ≥97%
Power factor| ≥ 0.99 (of the rated current)
Environment condition
| Working
temperature
| -10°C – +50°C; Derating is required when the ambient temperature
exceeds 40°C.
Relative humidity| 5%–95%, no condensation
Installation altitude| Below 1000m (Derating is required when the altitude
exceeds 1000m. Derate by 1% for every increase of 100m.)
Mechanical data
| Anti-vibration
performance
| Compliant with 3 M4 vibration level in GB/T4798.3
IP rating| For the module: IP00
Safety performance| Compliant with EN 61800-5-1
Cooling method| Forced air cooling
Protection function| Protection function| Including functions of protection
against short circuits, overcurrent, overload, overvoltage, undervoltage,
overtemperature, and phase loss
Product nameplate
Figure 1-1 Product nameplate
Note:
- Figure 1-1 is a product nameplate example. The specification markings are subject to the machine nameplate.
- The model designation code contains basic product information such as rated current and rated voltage.
Product model
The model designation code contains product information. You can find the model designation code on the product nameplate.
Product ratings
Table 1-2 Product ratings
Model
|
Rated value
| Light overload application| Heavy overload application|
Outline dimensions
|
Heat dissipation (kW)
|
Air volume (m 3 /h)
---|---|---|---|---|---|---
I N| I N| I max| S N| P N| I
LD| P LD| I HD| P HD
A (AC)| A (DC)| A (DC)| kVA| kW (DC)|
A (DC)| kW (DC)| A (DC)| kW (DC)
GD880-91-0094-4| 94| 107| 140| 65| 64| 103| 62| 81| 48| A3| 1.92| 179
GD880-91-0116-4| 116| 132| 172| 80| 78| 127| 76| 99| 59| A4| 2.34| 255
GD880-91-0149-4| 149| 170| 221| 103| 102| 164| 98| 128| 77| A4| 3.06| 255
GD880-91-0183-4| 183| 209| 272| 127| 126| 201| 120| 157| 94| A4| 3.78| 255
GD880-91-0220-4| 220| 251| 326| 153| 151| 241| 145| 188| 113| A6| 4.53| 1000
Model
|
Rated value
| Light overload application| Heavy overload application|
Outline dimensions
|
Heat dissipation (kW)
|
Air volume (m 3 /h)
---|---|---|---|---|---|---
I N| I N| I max| S N| P N| I
LD| P LD| I HD| P HD
A (AC)| A (DC)| A (DC)| kVA| kW (DC)|
A (DC)| kW (DC)| A (DC)| kW (DC)
GD880-91-0260-4| 260| 296| 385| 179| 178| 284| 171| 222| 133| A6| 5.34| 1000
GD880-91-0312-4| 312| 355| 462| 216| 214| 341| 205| 266| 161| A7| 6.42| 1000
GD880-91-0395-4| 395| 452| 587| 274| 271| 433| 260| 339| 203| A7| 8.13| 1000
GD880-91-0516-4| 516| 590| 767| 357| 354| 565| 339| 442| 265| A7| 10.62| 1000
Unit outline dimensions and weight
Outline
dimensions
| Height (mm)| Width (mm)| Depth (mm)| Net
weight (kg)
---|---|---|---|---
A3| 440| 100| 435| 8.7
A4| 440| 200| 435| 19.5
A6| 850| 200| 415| 45
A7| 980| 200| 415| 55
Configuration list
The configuration list of GD800-91 active rectifier products of different power is as follows:
Rated/heavy- load
power
| No.| Name| Model| Order No.| Qty
---|---|---|---|---|---
64kW/48kW
| 1| Rectifier unit| GD880-91-0094-4| –| 1
2| LCL filtering component| LCL-0116-0.4SA-4149-RO| –| 1
3| Buffer
component
| HC-0110-4-Z| 19005–00360| 1
4
| Lightning protection
component
|
RV-380V
|
12029-00014
|
1
5| EMI component| GD800-LB| 90001–03990| 1
6
| Optical fiber expansion
module
|
EC-TX821
|
11023–00157
|
1
7
| AC voltage detection
module
|
IVDM-10
|
11023–00162
|
1
8| 1m optical fiber| HFBR-1M| –| 1
78kW/59kW
| 1| Rectifier unit| GD880-91-0116-4| –| 1
2| LCL filtering component| LCL-0116-0.4SA-4149-RO| –| 1
3| Buffer
component
| HC-0110-4-Z| 19005–00360| 1
4
| Lightning protection
component
|
RV-380V
|
12029–00014
|
1
5| EMI component| GD800-LB| 90001–03990| 1
6
| Optical fiber expansion
module
|
EC-TX821
|
11023–00157
|
1
7
| AC voltage detection
module
|
IVDM-10
|
11023-00162
|
1
8| 1m optical fiber| HFBR-1M| –| 1
102kW/77kW
| 1| Rectifier unit| GD880-91-0149-4| –| 1
2| LCL filtering component| LCL-0180-0.4SA-4149-RO| 91012–02219| 1
3| Buffer
component
| HC-0110-4-Z| 19005-00360| 1
4
| Lightning protection
component
|
RV-380V
|
12029-00014
|
1
5| EMI component| GD800-LB| 90001–03990| 1
|
6
| Optical fiber expansion
module
|
EC-TX821
|
11023–00157
|
1
---|---|---|---|---|---
7
| AC voltage detection
module
|
IVDM-10
|
11023–00162
|
1
8| 1m optical fiber| HFBR-1M| –| 1
126kW/94kW
| 1| Rectifier unit| GD880-91-0183-4| –| 1
2| LCL filtering
component
| LCL-0180-0.4SA-4149-RO| 91012–02219| 1
3| Buffer
component
| HC-0110-4-Z| 19005–00360| 1
4
| Lightning protection
component
|
RV-380V
|
12029–00014
|
1
5| EMI component| GD800-LB| 90001–03990| 1
6
| Optical fiber expansion
module
|
EC-TX821
|
11023–00157
|
1
7
| AC voltage detection
module
|
IVDM-10
|
11023-00162
|
1
8| 1m optical fiber| HFBR-1M| –| 1
151kW/113kW
| 1| Rectifier unit| GD880-91-0220-4| –| 1
2| LCL filtering
component
| LCL-0220-0.4SA-4149-RO| 91012–00885| 1
3| Buffer
component
| HC-0110-4-Z| 19005–00360| 1
4
| Lightning protection
component
|
RV-380V
|
12029–00014
|
1
5| EMI component| GD800-LB| 90001–03990| 1
6
| Optical fiber expansion
module
|
EC-TX821
|
11023–00157
|
1
7
| AC voltage detection
module
|
IVDM-10
|
11023–00162
|
1
8| 1m optical fiber| HFBR-1M| –| 1
9| LCD control
panel
| SOP-880| –| 1
178kW/133kW
| 1| Rectifier unit| GD880-91-0260-4| –| 1
2| LCL filtering
component
| LCL-0335-0.4SA-4149-RO| 91012–02222| 1
3| Buffer
component
| HC-200-4| 19005–00361| 1
|
4
| Lightning protection
component
|
RV-380V
|
12029–00014
|
1
---|---|---|---|---|---
5| EMI component| GD800-LB| 90001–03990| 1
6
| Optical fiber expansion
module
|
EC-TX821
|
11023–00157
|
1
7
| AC voltage detection
module
|
IVDM-10
|
11023–00162
|
1
8| 1m optical fiber| HFBR-1M| –| 1
9| LCD control
panel
| SOP-880| –| 1
214kW/161kW
| 1| Rectifier unit| GD880-91-0312-4| –| 1
2| LCL filtering
component
| LCL-0335-0.4SA-4149-RO| 91012–02222| 1
3| Buffer
component
| HC-200-4| 19005–00361| 1
4
| Lightning protection
component
|
RV-380V
|
12029–00014
|
1
5| EMI component| GD800-LB| 90001–03990| 1
6
| Optical fiber expansion
module
|
EC-TX821
|
11023–00157
|
1
7
| AC voltage detection
module
|
IVDM-10
|
11023–00162
|
1
8| 1m optical fiber| HFBR-1M| –| 1
9| LCD control
panel
| SOP-880| –| 1
271kW/203kW
| 1| Rectifier unit| GD880-91-0395-4| 90001–02885| 1
2| LCL filtering
component
| LCL-380A-00214-2| 91012–02082| 1
3| CBU-C65-6-D| 11029–00093| 1
4| Buffer
component
| HC-200-4| 19005–00361| 1
5
| Lightning protection
component
|
RV-380V
|
12029–00014
|
1
6| EMI component| GD800-LB| 90001–03990| 1
7
| Optical fiber expansion
module
|
EC-TX821
|
11023–00157
|
1
8
| AC voltage detection
module
|
IVDM-10
|
11023–00162
|
1
9| 1m optical fiber| HFBR-1M| –| 1
| 10| LCD control
panel
| SOP-880| –| 1
---|---|---|---|---|---
354kW/265kW
| 1| Rectifier unit| GD880-91-0516-4| 90001–02885| 1
2| LCL filtering component| LCL-380A-00214-2| 91012–02082| 1
3| CBU-C65-6-D| 11029–00093| 1
4| Buffer
component
| HC-200-4| 19005–00361| 1
5
| Lightning protection
component
|
RV-380V
|
12029–00014
|
1
6| EMI component| GD800-LB| 90001–03990| 1
7
| Optical fiber expansion
module
|
EC-TX821
|
11023–00157
|
1
8
| AC voltage detection
module
|
IVDM-10
|
11023–00162
|
1
9| 1m optical fiber| HFBR-1M| –| 1
10| LCD control panel| SOP-880| –| 1
Electrical principle and wiring
The electrical principle and wiring diagram of GD880-91 active rectifier products are as follows:
Note:
Except for the components in the 2 Configuration list, other components in the
above figure need to be purchased separately.
Product dimensions
Rectifier unit dimensions
LCL filtering component dimensions
LCL model| Outline dimension (mm)| Installation
dimension (mm)| Net weight (kg)| Heat
dissipation (kW)
---|---|---|---|---
W| H| D| W1| D1| d1| d2
LCL-0116-0.4SA-4149-RO| 325| 560| 285| 243 ± 1| 149 ± 2| 4-M12| Ø11|
75| 0.43
LCL-0180-0.4SA-4149-RO| 390| 590| 330| 260 ± 1| 174 ± 2| 4-M15| Ø13|
136| 0.51
LCL-0220-0.4SA-4149-RO| 630| 390| 340| 260 ± 1| 184 ± 2| 4-M15| Ø13|
146| 0.67
LCL-0335-0.4SA-4149-RO| 430| 725| 350| 350 ± 1| 196 ± 2| 4-M15| Ø13|
180| 1.45
Model of reactor with double L
| Outline
dimension (mm)
|
Installation dimension (mm)
| Net weight (kg)| Heat dissipation (kW)
---|---|---|---|---
W| H| D| W1| D1| d1| d2
LCL-380A-00214-2| 390| 630| 340| 260±2| 184±3| 4-M15| Ø13| 190| 1.62
LCL-516A-01504-2| 390| 665| 350| 260±1| 240±2| 4-M15| 2* Ø12| 220| 1.1
Buffer component dimensions
Lightning protection component dimensions
EMI component dimensions
Voltage detection module
Installation of the control panel
Contact Information
Shenzhen INVT Electric Co., Ltd.
- Address:
INVT Guangming Technology Building, Songbai Road, Matian, Guangming District, Shenzhen, China
INVT Power Electronics (Suzhou) Co., Ltd.
- Address: No. 1 Kunlun Mountain Road, Science & Technology Town, Gaoxin District, Suzhou, Jiangsu, China
- Website: www.invt.com.
Copyright© INVT. Manual information may be subject to change without prior notice.
Read User Manual Online (PDF format)