About the GFX4 Digital Humidistat
In Automatic Mode the GFX4 will adjust the humidity in your home based on
the outdoor temperature, lowering the humidity in cold weather to reduce
condensation. The GFX4 can operate in Manual Mode to control humidity to a
specific relative Humidity. In most homes, Automatic operation is preferred to
reduce condensation on windows and within the structure. Manual mode is
necessary where the outdoor temperature sensor cannot be installed. Manual
mode may be desirable where valuable artwork, instruments or woodwork demand
constant humidity. The GFX4 has a dry contact for fan control (FAN1, FAN2
terminals). The LCD Display is backlit and easy to read. Operation and
Installation are simple. The GFX4 can be mounted on an interior wall or on the
return duct of the HVAC System.
WARNING
This Humidistat must be installed by a Qualified Technician. Always TURN
OFF POWER TO THE HVAC SYSTEM PRIOR TO INSTALLING OR SERVICING the Humidifier
or Humidistat. Improper operation can result in over or under humidification.
Over humidification can result in condensation, structural damage or mold.
Condensation within a building’s structure can cause a loss of structural
strength. Condensation can also enable mold and mildew growth resulting in
personal injury and damage to building structure and contents. Older and
poorly insulated structures cannot withstand the same humidity levels as newer
well-insulated buildings. Read these instructions carefully. This humidistat
requires a 24 volt, AC power supply. Improper voltage can cause malfunction or
damage to the control. Do not run outdoor sensor wires on or near line voltage
wires. The technical specifications for this product and the contents of the
user manual are subject to change without notice.
Specifications
GFX4 Locations
Outdoor Sensor Location
YES
North Wall East Wall Over Snow Line Inlet of Air Intake Less than 200’ from
humidistat.
NO
South Wall West Wall Below Snow Deep in Intake More than 200’ from
humidistat.
- Wall Installation
- Duct Installation
Wiring
Testing the System
- Re-assemble system and check all connections.
- Restore power to the HVAC system.
- Start HVAC System by raising the thermostat setting.
- Check to see that GFX4 display is on.
- Set to TEST MODE by pressing “Drop” and
- “thermo” together for 5 seconds. The relay will close and the “+” will flash for 2 minutes or press a key to set to OFF MODE.
- Set to OFF mode to verify humidifier operation ceases.
- The GFX4 will stay in OFF Mode unless set to Manual or Automatic mode. See “Operation”.
Operating Modes
Press any button to light the display. Press the “DROP” button to select
the Operating Mode, Off, Manual or Auto.
OFF Mode
The Humidifier is turned off.
MANUAL Mode
The GFX4 will work to maintain the single humidity selected. You can set
your desired “UP” humidity level by pressing “UP” or “DOWN”.The humidifier
will turn ON or OFF according to your manual setting. The humidifier will
operate when the measured relative humidity falls more than 1% below the set
point until the measured relative humidity is 1% above the set point. When the
humidifier is operating, the “+” will display. Humidity may have to be lowered
when the weather is colder or if condensation is suspected. The settings table
to the right or a similar table may be used to compensate for cold outside
temperatures.
AUTO Mode
The GFX4 will automatically raise the humidity as the outdoor temperature
increases. This provides the highest possible humidity. The GFX4 will
automatically lower the humidity as temperatures drop. This minimizes the risk
of condensation on cold surfaces like windows.The Auto Humidity Index Set
Point may be changed from 0 (low) to 10 (high) by pressing “UP” or “DOWN”. The
Humidity Index is based on the outdoor temperature and indoor humidity. The
humidifier will switch ON/OFF according to the calculated auto humidity index
set point. When the humidifier is operating, the “+” will display. Lower Index
settings are for older homes with less insulation and poor vapor barriers.
Higher Index settings are for newer homes with complete vapor barriers, triple
pane windows and high R value insulation.
- 1-2 Older than 1950, no vapor barrier, little insulation.
- 3-4 Built 1950-1965, no vapor barrier, R6 insulation.
- 5-6 Built 1965-1975, craft vapor barrier, R11 insulation.
- 7-8 Built 1980-1990, craft vapor barrier, R19, double pane windows.
- 9-10 Built after 1990, poly vapor barrier, R38 insulation, foam exterior cladding,triple pane windows.If condensation is seen or suspected, reduce index by 2 until condensation stops. The level bars indicate the humidity index; one bar for two index points.
AUTO Mode Target Humidity
OFFSET Mode
To change the calibration of the GFX4, an offset may be entered to the
Humidity, Indoor Temperature or Outdoor Temperature displays. Press both “UP”
and “DOWN” buttons together to enter OFFSET mode. The word “OFFSET” and “RH”
will display. Press “UP” or “DOWN” to change the humidistat’s Humidity
calibration. Press both “UP” and “DOWN” buttons together again to change the
Indoor Temperature offset. Press both “UP” and “DOWN” buttons together again
to change the Outdoor Temperature offset.
Display a Temperature
Press the “THERMOMETER” button to move between displaying indoor and
outdoor temperatures. “Tree” will be displayed when showing outdoor
temperature. “House” will be displayed when showing indoor temperature. To
change between °F and °C units, press the “ °F/°C ” button.
Trouble Shooting
“HOUSE” Flashing The indoor temperature sensor has failed. “TREE” Flashing The
outdoor temperature sensor has failed. Humidifier Turns On and Off Repeatedly
Check that input voltage is between 18 and 30 volts, AC and not intermittent.
Check that humidistat is NOT mounted: 1. on supply duct. 2. downstream of
humidifier. 3. closer to humidifier than 12 inches.
Make sure that Outdoor Sensor wiring is not close to line voltage wires.
Humidifier Runs Continuously
If humidifier operates while HVAC system is off, check that power to the
humidifier is switched with the HVAC operation. If the humidifier operates
every time HVAC System runs, compare humidity to set point. If humidity is
lower than set point, humidistat will call for operation.
Humidifier Does Not Run
Check wiring to/from GFX4 control. Verify 18-30 volts. Use “TEST MODE” .
Humidifier Runs When Air Conditioning Is On
If this is undesirable, change wiring to be powered only in heating
periods. Humidity not high enough Fault with Humidifier. Check humidifier,
water supply, electrical connections. HVAC operating time too short. Check
humidifier troubleshooting. Humidifier undersized. Review humidity load and
humidifier capacity.
Humidity Too High
Wiring fault. Set GFX4 to “OFF” mode and check that operation ceases. The
outdoor sensor is being kept warm. Check that sensor is not buried in snow, on
south side of house being warmed by sun or is too far inside of air intake.
Limited Warranty
This humidistat is warranted to the consumer against defects in materials and
workmanship for a period of one year from the date of installation. Defective
parts will be repaired without charge except for removal, reinstallation and
transportation costs. To obtain repair service under this limited warranty,
the consumer must send the defective part to the manufacturer. There are no
express warranties covering this humidistat other than set forth above. The
implied warranties of merchantability and fitness for a particular purpose are
limited in duration to one year. The manufacturer assumes no liability in
connection with the installation or use of this product, except as stated in
this limited warranty. The manufacturer will in no event be liable for
incidental or consequential damages.
Any questions pertaining to this limited warranty should be addressed to the
manufacturer. USA: The manufacturer has elected not to make available the
informal dispute settlement mechanism which is specified in the Magnuson-M oss
Warranty Act.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>