RENISHAW SFM-E2 Surface Finish Probe Module Installation Guide

June 4, 2024
RENISHAW

SFM-E2
Surface finish probe module

Typical applications
Automatic transmission valve bodies,
minimum feature access (mm):
Ø9 × 122 (max. depth).

Enhanced access and inspection capability for integrated surface finish measurement
The SFP2 system consists of a probe and a range of SFM modules that have been designed to suit the demands of specific parts and features encountered in a precision manufacturing environment. The probe and modules can be automatically interchanged with all other REVO® probe options,
providing the flexibility to easily select the optimum tool to inspect a wide range of features. Each SFM module is its own miniature measuring device, incorporating Renishaw’s proprietary encoder system to transduce the motion of the stylus tip.

Features

The E-series of modules use dual skids with a central stylus. This makes them ideal for short scans on small to medium-sized bores which may be deep within the workpiece.
Due to the extreme length of this module, Renishaw recommends that the CMM’s capability to use the SFM-E2 should be verified before full implementation.

NOTES: Not compatible with SFH-2.
Scan speeds may need to be reduced for finer finishes.

Specification

Diamond tip radius (pm) 5
Surface finish measurement range (pm) 6.3 to 0.10 Ra
Typical surface finish accuracy (of nominal Ra) ‘ ±(20% + 60 nm)
Skid / stylus arrangement Stylus central to dual skids
Skid material DLC coated stainless steel
Nominal stylus tip protrusion beyond skid (mm) 0.6
Minimum feature access (mm) 09 x 122 (maximum depth)
Skid length / radius (mm) 4/6/40
Skid width / radius (mm) 5.0 (total) / n/a
Skid contact force (N) 0.15
Stylus contact force (N) 0.01
SFM / SFH knuckle adjustment range ±90°
Weight (g) 13
Resolution (nm) 1
Measurement speed (mm/s) Up to 0.5
Stylus holder compatibility SFH-1 only
Lateral scanning capability No
  • Accuracy values are dependent upon a number of system variables. These include the machine size and configuration, scan orientation, condition of the stylus tip, part fixturing system, and environmental noise.

All dimensions in mm.

RENISHAW SFM-E2 Surface Finish Probe Module - fig1

+44 (0) 1453 524524
uk@renishaw.com

© 2018–2021 Renishaw plc. All rights reserved. RENISHAW® and the probe symbol are registered trademarks of Renishaw plc.
Renishaw product names, designations and the mark ‘apply innovation’ are trademarks of Renishaw plc or its subsidiaries. Other brands, products or company names are trademarks of their respective owners.
Renishaw plc. Registered in England and Wales. Company no: 1106260. Registered office: New Mills, Wotton-under-Edge, Glos, GL12 8JR, UK.
WHILE CONSIDERABLE EFFORT WAS MADE TO VERIFY THE ACCURACY OF THIS DOCUMENT AT PUBLICATION, ALL WARRANTIES, CONDITIONS, REPRESENTATIONS, AND LIABILITY, HOWSOEVER ARISING, ARE EXCLUDED TO THE EXTENT PERMITTED BY LAW.

Part no.: H-1000-2311-04-A
Issued: 10.2021