multiLane V93000 CTH ATE Twinning Frame Site Preparation User Guide
- June 3, 2024
- multiLane
Table of Contents
- multiLane V93000 CTH ATE Twinning Frame Site Preparation
- Air Supply – Site Utility Requirement
- Smartest Software
- Twinning Frame
- Ethernet Port
- MultiLane Power Supply – Supplied by V93000
- MultiLane Utility Box Interconnects
- Manipulator and Test head Upgrades – Contact Advantest
- Advantest Site Planning Information – Contact Advantest
- Notices
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
multiLane V93000 CTH ATE Twinning Frame Site Preparation
Overview
This document is used to prepare the customer site for the MultiLane High Speed I/O option used with either an Advantest V93000 CTH or STH. The only additional site resource required is the Site Utility Air Supply. All other resources and connections are made between the MultiLane option and the existing V93000 tester cell.
Figure 1: MultiLane System Connection Overview Figure 2: MultiLane Utility Box Location (Service Positions taken from Advantest TDC)
Air Supply – Site Utility Requirement
MultiLane instruments are air cooled and require in customer site utility air supply
Specification | Value | Comments |
---|---|---|
CFM1 | 3 CFM min, continuous 6 CFM, max, continuous | Need continuous CFM while |
ML instruments are powered on
PSI| 60 PSI max| 4 bar equivalent
NPT “A” style coupler| Recommended
PUSH-TYPE: Sleeve release
| Feeds air cable from utility air supply to ML Utility Box
Distance from Site Utility Air supply to Utility Box| 3 meters (10 ft) max|
Utility Box is assumed to be next to V93000 workstation
Figure 3: Site Air Supply Coupler Type
Smartest Software
The following software must be installed before installing MultiLane Smartest API’s:
Specification | Value | Comments |
---|---|---|
RedHat | Rev 7.4 | |
V93000 Smartest | 7.5 or higher | Must be a Smartest “7.x” |
version
Site must support fixed IP address assignments| Contact MultiLane for instrument pre-assigned values| For MultiLane instruments
Twinning Frame
Additional information available on the Advantest TDC website:
Twinning guide – Advantest Technical Documentation Center 5.3.0 BETA
A storage area at the customer site is recommended when twinning frame is not
in use
Specification | Value | Comments |
---|---|---|
Dimensions | 0.52 x 1.71 x 1.25 | Height (Ft) x Width x Depth |
Dimensions | 0.16 x 0.52 x 0.38 | Height (m) x Width x Depth |
Weight | 40 kg | Doesn’t include customer DIB kg |
Storage Container | Not Provided | Shipping Box only |
ESD | ESD sensitive devices | |
Docking personnel | Recommend 2 people | Docking to CTH or STH |
Figure 4: Operator Holding MultiLane Card Cage (also called “Twinning Frame”)
Ethernet Port
Specification | Value | Comments |
---|---|---|
Ethernet Port drop, customer site to V93000 workstation | 1 drop | Nothing extra |
from standard V93000 ethernet drop
Bridge Network, V93000 workstation to MultiLane| 192.168.0.X| Not a site
prep requirement.
Shown here for completeness
Figure 5: Ethernet Connections
MultiLane Power Supply – Supplied by V93000
MultiLane power is supplied by the Advantest V93000. It is not supplied directly from the customer site. V93000 power outlets are provided for both the CTH and STH cases. The MultiLane Power supply takes an AC voltage in (see table below) and creates 12 V out for the MultiLane instruments Connecting the mains cable and powering up – Advantest Technical Documentation Center 5.3.0 BETA
Figure 6: V93000 STH power switched outlets Figure 7: V93000 CTH power switched outlet
MultiLane Utility Box Interconnects
Figure 8: Multi Lane Utility Box Dimensions (mm) Figure 9: MultiLane System Detailed Utility Box Interconnects
Manipulator and Test head Upgrades – Contact Advantest
Consult with Advantest to make sure the manipulator can support the additional twinning frame weight. Consult with Advantest to make sure the onsite V93000 test head has all the upgrades required to hard dock with the MultiLane twinning frame
Advantest Site Planning Information – Contact Advantest
Additional site planning information can be found in the Advantest CTH and STH site planning documentation. For example,
- Facility environmental conditions: (Advantest TDC topic 128630)
- ESD prevention: (Advantest TDC topic 128733)
Notices
Copyright © MultiLane Inc. All rights reserved. Licensed software products are
owned by MultiLane Inc. or its suppliers and are protected by United States
copyright laws and international treaty provisions.
Use, duplication, or disclosure by the Government is subject to restrictions
as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and
Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) an d
(2) of the Commercial Computer Software — Restricted Rights clause at FAR
52.227-19, as applicable.
MultiLane Inc. products are covered by U.S. and foreign patents, issued and
pending. Information in this publication supersedes that in all previously
published material. Specifications and price change privileges re served.
General Safety Summary
Re view the following safety precautions to avoid injury an d prevent damage
to this product or any products connected to it. To avoid potential hazards,
use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system.
Read the General Safety Summary in other system manuals for warnings and
cautions related to operating the system.
To Avoid Fire or Personal Injury
Use Proper Power Cord. Only use the power cord specified for this product
and certified for the country of use.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all
ratings and markings on the product. Consult the product manual for further
ratings information before making connections to the product.
Do not apply a potential to any terminal, including the common terminal that
exceeds the maximum rating of that terminal.
Do Not Operate Without Covers.
Do not operate this product with covers or panels removed.
Avoid Exposed Circuitry. Do not touch exposed connections and components
when power is present.
Do Not Operate with Suspected Failures.
If you suspect there is damage to this product, have it inspected by qualified
service personnel.
Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive
Atmosphere. Keep Product Surfaces Clean and Dry
Caution statements identify conditions or practices that could result in
damage to this product or other property.
North America
48521 Warm Springs Blvd.
Suite 310
Fremont, CA 94539, USA
+1 510 573 6388
Worlwide
Houmal Technology Park
Askarieh Main Road
Houmal, Lebanon
+961 81 794 455
Asia
14F-5/ Rm.5, 14F., No 295
Sec.2, Guangfu Rd. East Dist.,
Hsinchu City 300, Taiwan (R.O.C)
+886 3 5744 591
UAE
Building 4WA, Office 420
Dubai Airport Freezone Authority,
UAE
Dubai,
+9714 5487 547
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>