multiLane ATE HSIO CARD CAGE for Use with Advantest V93000 CTH and STH Testers Installation Guide

June 10, 2024
multiLane

multiLane ATE HSIO CARD CAGE top

ATE HSIO CARD CAGE ­- SITE INSTALL

FOR USE WITH ADVANTEST V93000 CTH AND STH TESTERS

Revision Date: 11/23/2021

Innovation for the next generation

Overview

This document is used to install the Multilane (ML) High Speed I/O option at the customer site. The only additional site resource required by ML is the Site Utility Air Supply. All other resources and connections are made between the Multilane option and the existing V93000 tester cell.

This installation manual assumes the Multilane software and customer test programs are properly installed on the V93000 workstation. You are only installing the hardware with the help of this manual.

Applicable Multilane Documents
  1. Site Preparation manual
  2. Utility Box manual
  3. System manual
  4. Diagnostics manual

multiLane ATE HSIO CARD CAGE figure 1Figure 1: Multilane System Connection Overview

  1. Site Resources
  2. V93000 Tester Cell
  3. This cable bundle is disconnected from the ML Card Cage when undocking and storing the ML Card Cage. All other cables in this diagram remain connected and stay with the V93000 tester cell
  4. ML Card Cage
  5. Cable Bundle: Air, Power, Ethernet
  6. ML Utility Box
  7. Power from CTH Outlets
  8. Power from STH Outlets
  9. V93000 System Controller
  10. Ethernet Cable
  11. Air Cable
  12. Site Utility Air

multiLane ATE HSIO CARD CAGE figure 2a

multiLane ATE HSIO CARD CAGE for Use ZA1.
Figure 2: Multilane System with cables between Utility Box and Testhead

Making System Connections
  1. Connect “air input” air cable assembly
    a. Connect air cable between site utility air supply and Utility box
    b. Site Utility Air Air Input in Figure 3: Utility Box Inputs/Outputs.

  2. Connect “V93000 power” cable
    a. Connect power cable between STH/CTH location and Utility box power input
    b. If V93000 is STH, then refer to Figure 9: V93000 STH power switched outlets.
    c. If V93000 is CTH, then refer to Figure 8: V93000 CTH power switched outlet.
    d. STH/CTH Power Power Input in Figure 3: Utility Box Inputs/Outputs.

  3. Connect “Workstation Ethernet” cable
    a. Connect Ethernet cable between V93000 workstation and Utility box LAN input
    b. Refer to V93000 manual for ethernet cable connection
    c. V93000 Ethernet LAN input in Figure 3: Utility Box Inputs/Outputs.

  4. Connect “air output” air cable assembly
    a. Open Air door of utility box. Feed air tube into air regulator output and out of top of utility box
    b. Air Cable from utility box Air Supply Input in Figure 7: Twinning Frame Faceplate.

  5. Connect “LAN outputs”
    a. Connect 2 Ethernet cables between the utility box and the twinning frame
    b. Each ethernet cable can plug into either LAN connection
    c. Utility Box LAN outputs LAN Connections in Figure 7: Twinning Frame Faceplate.

  6. Connect “Power output”
    a. Connect power cable between the utility box and the twinning frame
    b. Utility Box Power outputs +12V Power Input in Figure 7: Twinning Frame Faceplate

  7. Tie wrap the cables going between the utility box and twinning frame
    a. Air supply, power cable, ethernet cables

multiLane ATE HSIO CARD CAGE figure 3Figure 3: Utility Box Inputs/Outputs

  1. Air Input
  2. Power Input
  3. LAN Input
  4. Air Output
  5. Power Output
  6. LAN Output (Optional)
  7. LAN Output
Checking System Connections
  1. Check system air
    a. Turn on utility box air. See ballcock valve in Figure 7: Twinning Frame Faceplate.
    b. Using air regulator inside utility box, set CFM to be 3 CFM¹
    c. Listen for air exiting into Multilane twinning frame

  2. Check system power
    a. Turn on V93000 power →Note utility box power input LED is ON
    b. Manually turn on twinning frame power via toggle switch located on utility box Note utility box +12V power LED is ON
    c. Power toggle switch and power on LED are shown in Figure 4: Utility Box Buttons and LED Indicators

  3. Check LAN connection
    a. Note ethernet IP addresses of each Multilane instrument inside the card cage
    b. For each IP address, PING the IP address and verify a PING response is returned

  4. Run Multilane loopback diagnostics

multiLane ATE HSIO CARD CAGE figure 4Figure 4: Utility Box Buttons and LED Indicators

  1. Power ON from Power Outlet to Utility Box
  2. +12V Power ON to Twinning Frame

¹ Check with Multilane for CFM requirements for customized instruments

multiLane ATE HSIO CARD CAGE figure 5

multiLane ATE HSIO CARD CAGE figure 6Figure 5: Multilane System Detailed Utility Box Interconnects

multiLane ATE HSIO CARD CAGE figure 7Figure 6: Multilane Card Cage (aka “Twinning Frame”)

multiLane ATE HSIO CARD CAGE figure 8Figure 7: Twinning Frame Faceplate

multiLane ATE HSIO CARD CAGE figure 9Figure 8: V93000 CTH power switched outlet

  1. Cooling water out
  2. High speed optical link
  3. Handler/prober interface
  4. Mains power in
  5. Cooling water in
  6. Compressed air in
  7. CIF cable to cooling unit
  8. Serial diagnostic link
  9. ON/OFF Unit cable
  10. Nitrogen in
  11. Pressure governors
  12. Pressure gauges
  13. Main breaker
  14. Mains power out

multiLane ATE HSIO CARD CAGE figure 10Figure 9: V93000 STH power switched outlets

  1. Mains power switched outlets
Multilane Recommended Utility Box Site Location

multiLane ATE HSIO CARD CAGE figure 11 Figure 10: Multilane Utility Box Location

multiLane ATE HSIO CARD CAGE figure 12Figure 11: Multilane Utility Box Dimensions (mm)

MultiLane Regional Locations

North America
48521 Warm Springs Blvd.
Suite 310
Fremont, CA 94539, USA
+1 510 573 6388

Worlwide
Houmal Technology Park
Askarieh Main Road
Houmal, Lebanon
+961 81 794 455

Asia
7th Floor-2, No. 156
Sec. 2, Dongda Road, North District,
Hsinchu City 300, Taiwan (R.O.C.)
+886 3 5744 591

UAE
Building 4WA, Office 420
Dubai Airport Freezone Authority,
Dubai, UAE
+971 4 548 7 547

References