CyberPower P205UCPDQ Desktop Power Charger User Manual
- June 3, 2024
- CyberPower
Table of Contents
YOUR ULTIMATE ALLY IN POWER
Desktop Power Charger
with 20W PD, Qi Wireless,
and Surge Protection
P205UCPDQ
USER MANUAL
FEATURES
-
Standard Grounded Outlets (2)
-
Wireless Charging Pad
-
Qi Charging LED Indicator
Illuminated when it is charging a device. -
Protected LED Indicator
Illuminated when the surge protection feature is working properly. -
USB-A Charging Port (1)
-
USB-C Charging Port (1)
SPECIFICATIONS
Model Number: | P205UCPDQ |
---|---|
Outlets: | Standard Grounded Outlets (2), USB Charging Ports (2) |
Electrical Rating: | 125 V/13 A/1625 W |
Surge Protection: | 1,500 Joules |
USB-A Charging Output: | 5 V/2.4 A Max |
USB-C Charging Output: | 5 V/3 A Max, 9 V/2.22 A Max |
USB Total Output: | 20 W |
Wireless Charging Output: | 10 W |
UL Clamping Voltage: | UL 1449 4th/600 V (L-N, L-G, N-G) |
Maximum Peak Current: | 45,000 A |
3 AC Lines Protected: | L-N: 15,000 A; L-G: 15,000 A; |
N-G: 15,000 A
Response Time:| Less than 1 nanosecond
Power Cord Length:| 5 ft
Plug Type:| Low Profile
WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene (ABS), which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK:
Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOT “daisy chain” surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is not at least 10 meters (30 feet) of
wire between the electrical outlet and electrical service panel.
DO NOT use for medical or life support equipment. This device features an
internal protection that will disconnect the surge protective component at the
end of its useful life, but it will maintain unprotected power to the load.
TROUBLESHOOTING
Protected indicator does not light
– The surge protector’s AC lines are no longer protected from surge. The surge
protector may have received a power surge or spike beyond its specified limits
that has overloaded the protection circuitry and rendered it inactive. The
surge protector has protected your connected equipment as designed, but it
will not protect against future surges and spikes. It should be replaced. Qi
charging LED is flashing
– Make sure that your device is Qi-enabled.
– Make sure that your device is on the center of the charging pad with the
screen facing up.
– Make sure that there are no other objects on the charging pad.
– Remove the case of your device. It may be blocking the wireless signal.
FOR MORE INFORMATION
Visit CyberPowerSystems.com for more
information regarding:
- Product information and certifications
- Product warranty
- Connected equipment guarantee
TECHNICAL SUPPORT
Visit: CyberPowerSystems.com/support
Toll-Free: 1-877-297-6937
© 2022 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.
CONFORMANCE APPROVALS
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Part 18 of the FCC Rules.
- The interference potential of the device or system.
- Maintenance of the system.
- Simple measures that can be taken by the user to correct interference.
- For RF lighting devices, provide an advisory statement, either on the product packaging or with other user documentation, similar to the following:
This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority tooperate the equipment.
K01-1101100-01
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com
References
- CyberPower UPS Systems, Battery Backup, PDUs, USB Surge Protectors
- Support | CyberPower
- P65Warnings.ca.gov
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>