PRAXISDIENST Star 5000 Fetal Monitor Owner’s Manual
- September 27, 2024
- PRAXISDIENST
Table of Contents
- Star 5000 Fetal Monitor
- Product Information
- Specifications
- Front View
- Monitor Model
- Right View
- Rear View
- On-screen Display
- Product Usage Instructions
- Installation
- Operation Guide
- Maintenance
- Frequently Asked Questions (FAQ)
- Q: Can I use this monitor without connecting it to a power
- Q: How do I reset alarms on the monitor?
Star 5000 Fetal Monitor
“`html
Product Information
Specifications
- Screen: 5.6-inch tiltable and foldable
- Display: Waveforms, menus, alarms, parameters, and data
- Controls: Keys and control knob
Front View
-
Alarm indicator: emits light of different colors for different
alarm levels -
Logo: COMEN
-
Keys: Alarm reset, Freeze/unfreeze, Record/stop, TOCO reset,
Main menu, Power on/off -
Paper compartment: for printing paper
Monitor Model
-
Screen: 5.6-inch tiltable and foldable screen
-
Indicator: AC indicator, Battery indicator, Battery charging
indicator -
Knob: For menu selection and value changes
-
Paper compartment lock: Locks/unlocks the compartment door
Right View
-
Interfaces: FHR socket 1, FHR socket 2, Fetal movement marker
sensor socket, TOCO socket -
Loudspeaker: For fetal heartbeat
Rear View
- Supporting shaft: To support the display
- USB port
- Network port: For network connection
- Handle: For moving the monitor
- Power socket: For power supply connection
- Equipotential terminal: Connects with equipotential
connector
On-screen Display
-
Network Connection Icon
-
Patient information area
-
Technical alarm message area
-
Physiological alarm message area
-
Timed monitoring information area
-
Icons area: Printer icon, FHR volume icon, Alarm volume icon,
Battery icon -
System time
-
Waveform area
-
Parameter area
The monitor features a 5.6-inch display and can be operated
using keys and a control knob.
Product Usage Instructions
Installation
-
Read the product instruction manual carefully before
installing. -
Ensure all components are included and in good condition.
-
Connect the power supply to the monitor.
-
If connecting to a network, use the appropriate port at the
rear of the monitor.
Operation Guide
-
Press the Power on/off key to switch on/off the monitor.
-
Use the Keys and Knob to navigate menus, adjust values, and
initiate functions. -
Monitor various parameters and data on the screen.
-
If using the printer function, ensure paper is loaded in the
paper compartment.
Maintenance
-
Clean the screen and external surfaces regularly with a soft,
dry cloth. -
Avoid exposing the monitor to extreme temperatures or
moisture. -
Keep the paper compartment clean and free from debris.
Frequently Asked Questions (FAQ)
Q: Can I use this monitor without connecting it to a power
supply?
A: Yes, the monitor can be powered by a battery when not
connected to an AC power source. Ensure the battery is charged for
uninterrupted use.
Q: How do I reset alarms on the monitor?
A: Use the Alarm reset key to clear alarms on the monitor. Refer
to the instruction manual for specific alarm reset procedures.
“`
Copyright
p VersionA p No.046-001670-00 p Add.Floor 10, Floor 11 and Section C of Floor
12 of Building 1A & Floor 1 to Floor 5 of Building 2,
FIYTA Timepiece Building, Nanhuan Avenue, Matian Sub-district, Guangming
District, Shenzhen, Guangdong, 518106, P.R. China
Note
p Quick operation guide serves as a convinient way for you to master the basic
functional operation of this product. Please refer to the product instruction
manual for detailed instructions.
p Please carefully read and understand the contents of the product instruction
manual before installing and using this product to ensure the correct use of
this product and to ensure the safety of patients and operators.
p All illustrations provided herein are for reference only. The menus,
options, values and functions shown in the illustrations may be not exactly
identical to what you see on the monitor. If you have any doubtplease contact
our company.
p The content of this quick operation guide is subject to changes without
prior notice. All rights reserved by Shenzhen Comen Medical Instruments
CO.,Ltd.
Product Introduction
Front View
Alarm indicator: emitting light of different colors according to different alarm levels. Logo: COMEN. Keys: nAlarm reset key nFreeze/unfreeze key nRecord/stop key: press this key to start a real-time recording. nTOCO Reset key nMain menu key Power on/off key: press this key to switch on/off the monitor.
Paper compartment: printing paper is put here.
Monitor model
Screen:5.6-inch tiltable and foldable screen to display waveforms,
menus, alarms and various parameters and data.
Indicator
nAC indicator
Onthe monitor is powered by AC supply
n
Off: the monitor is not connected to AC power.
nbattery indicator Onthe monitor is powered by the battery
n
Off the monitor is not powered by the battery
nbattery charging indicator Onthe battery is being charged
n
Off: The battery is fully charged.
Knob: turn this knob to select menu items or change values.
Paper compartment lock: lock/unlock the compartment door.
1
Product Introduction
Right View
1. Interfaces: including four sockets with the same definition, used as Fetal
Heart Rate (FHR) socket 1, FHR socket 2, socket of fetal movement marker
sensor and TOCO socket.
2. Loudspeaker: loudspeaker for fetal heartbeat.
2
Rear View
1. Supporting shaft: to support the display. 2. USB port 3. Network port: for
connection to the network. 4. Handle: you can hold the handle to move the
monitor. 5. Power socket: to connect with the power supply 6. Equipotential
terminal: to connect with
equipotential connector.
12
3
1
8
8
On-screen Display
4
5
6
7
-
3. 4.
9 5. 6.
7. 8. 9.
Network Connection Icon, Select the network connection icon to directly access [NETWORK SET] menu. Patient information area, select here to directly access [PATIENT INFO] menu. Technical alarm message area Physiological alarm message area, select here to directly access [ALARM RECALL] window. Timed monitoring information area, Click here to directly access [TIMER] menu. Icons area, Printer icon, FHR volume icon, Alarm volume icon, Battery icon. System time Waveform area Parameter area
It features a 5.6 inches display and can be operated with both keys and control knob.
Main screen
3
Basic Operations
Using the Main Menu
Select the
on-screen key to access [MAIN MENU]
and perform operations and settings.
Setting the system time 1. Select the system time area to enter the [Date time
Setup] menu; 2. Or access [Main Menu] [Monitor Setup][Time Setup];
Set the system time according to your local time.
Changing System Language 1. Access [Main Menu] [Maintain] and enter the
password; 2. Select [Language] to select the required system language.
Setting the Minimum Alarm Volume 1. Enter [Main Menu] [Maintain] (Maintenance)
and input
the password; 2. Enter [Alarm Setup] [Min. Alm Volume] to set the
minimum alarm volume (range: 0-5).
Setting Alarm Volume 1. Enter [Main Menu] [Option Setup] [Alm Vol] (Alarm
Volume) to set the alarm volume (range: X-6, where X is the minimum alarm
volume). 2. Select the alarm volume icon to set the alarm volume (range: X-6,
where X is the minimum alarm volume).
FHR Volume Setup 1. Enter [Main Menu] [Option Setup] [FHR Vol] (FHR volume)
to set up FHR volume; 2. Select FHR volume in the pop-up list (options: 0, 1,
2, 3, 4, 5, 6).
When it is set to 0, the FHR volume icon changes to .
Key Volume Setup 1. Enter [Main Menu] [Option Setup]; 2. Select [Key Vol] (Key
Volume) to adjust it (options: 0, 1, 2, 3, 4, 5,
6).
Print setup
1. Enter [Main Menu] [Monitor Setup] [Print Setup];
2. Or select print icon
on icon area.
4
Basic Operations
Alarm Limit You can set up the alarm limits for all alarm levels with the same
method. Here FHR1 is taken as an example: 1. Select the FHR1 parameter area;
2. Select [FHR1 Alarm Setup] in the pop-up [FHR1 Setup] window to enter the
FHR1 alarm setup menu
Alarm Delay 1. Enter [Main Menu] [Maintain] and input the password; 2. Enter
[Alarm Setup]; 3. Select [Alarm Delay Time] and select an appropriate delay
time on the pop-up menu.
Patient Management 1. Select patient information area or select [Patient
Management] on-screen key. 2. In the pop-up menu, go to admit the patient,
modify the
patient information and discharge the patient . Changing screens 1. Select
[Screens] on-screen key; 2. Or access [Main Menu] and select [Screens] How to
save user default settings: 1. Access [Main Menu], select [Maintain] and enter
the
password;
1. Select [Save Current As User Config] to save current settings.
How to use factory adult/pediatric/neonate default settings:
1.Access [Main Menu][Monitor Setup] [Restore Default Configuration]; 2.Select
[Adopt Factory Default Adu Config], [Adopt Factory Default Ped Config] or
[Adopt Factory Default Neo Config], the alarm limit will restore to the
factory default settings.
How to start timed monitoring
1. Select the timed monitoring information area on the screen
,such as
.
2. Or select [Timed Monitor] on-screen key;
3. Enter the [Timed Monitor] menu to set the related
parameters.
How to select score:
1.Enter [Main Menu] [Monitor Setup] [Print Setup]; 2.Or select print icon on
icon area. 3.Select [Score Select] to show the scores on the case report.
4.Select [Score Criterion] to select scoring criterion you use (options:
[KREBS], [Fischer], [Advanced Fischer], [NST]).
5
Changing record paper:
Record paper Paper roller
6
Printing
Thermal print head
Paper compartment lock 1. Unlock the paper compartment with your right hand
and open the compartment door outwards; 2. Put new record paper into paper
slot with the grid side facing up and top of the paper (210) toward the left
of the monitor; 3. Pull the paper through top of the paper roller until it
reaches out of the opening, and put the paper upright; 4. Press down the door.
Make sure the door is properly locked.
Printing
Real-time Printing Real-time printing means the printing triggered by pressing
the print key on the front panel during real-time monitoring.
How to print fetal waveform during real-time monitoring: 1.During real-time
monitoring, press the print key on the front panel and enter the [Patient Info
& Fischer Grade] window; 2.Confirm the patient information and score results
and select [Confirm]. The monitor starts to print the fetal waveform according
to the speed set in [Real Speed] and the time set in [Real Time]. 3.To stop
printing during printing process, just press the print key on the front panel
or select the [Print] on-screen key. If [Report] is set to [ON], the monitor
will output the score report immediately and then stop printing; if [Report]
is set to [OFF], the monitor will stop printing immediately.
How to print the fetal waveform under frozen waveform status: 1. Under frozen
waveform status, press the print key on the front panel and enter the [Patient
Info & Fischer Grade] window; 2. Confirm the patient information and score
results and select [Confirm]. The monitor will start to print the frozen fetal
waveform from the very left waveform on current screen according to the time
length set in [Freeze Time]. 3. If the [Report] is set to [ON], the score
report will be printed after frozen fetal waveform.
Stored Patient Case Printing: Stored patient case printing means the printing
triggered by pressing the print key on the front panel and enter patient case
review interface.
How to print stored patient case: 1. Access [Case List] window; select a
certain patient case and enter [Patient Review] window; 2. Select [Load] and
enter the patient case review window; 3. Press the print key on the front
panel or select the [Print] on-screen key and enter the [Patient Info &
Fischer Grade] window; 4. Confirm the patient information and score results
and select [Confirm]. The monitor will start to print the fetal waveform from
the very left waveform on current screen according to the time length set in
[Freeze Time].
7
Battery
The monitor is equipped with a built-in rechargeable battery. When an AC power supply is connected, the battery is charged automatically until it is fully charged. In the event of unexpected power outage, the system automatically uses the battery to supply power, thus to avoid interruption of device operation. After grid power supply is cut off, the battery indicator turns on.
To understand the battery icon:
·
indicating the battery is fully charged.
·
indicating moderate battery power.
·
indicating low battery power.
·
indicating critically low battery power, please charge the battery immediately.
·
indicating no battery installed or damaged battery.
8