AURORALIGHT UDW110244 TAOS 6 Inch Underwater Light Installation Guide
- September 27, 2024
- auroralight
Table of Contents
UDW110244 TAOS 6 Inch Underwater Light
Product Information
Specifications:
- Model: UDW110244
- Fixture Type: Outdoor Luminaire
- Power Supply: 20AWG wires
- Required Tools: 3/32 Allen Key, Wire Cutter/Stripper
Product Usage Instructions:
-
Disconnect transformer from the electrical supply and ensure
power supply is off. -
Fixtures should be installed by a licensed electrician for
safety. -
Place the fixture with CAM-LOC W/SPOOL KIT in the desired wet
or dry location. -
Neatly wrap any excess cable around the base of the spool kit,
leaving enough slack for rotation. -
Connect the 20AWG wires to the main supply cable using UL
listed connectors suitable for underground and wet locations. -
Use appropriate UL listed underground feeder (UF) cable for
connections. -
For light aiming, loosen the wing nut, rotate the fixture, and
tighten the wing nut back.
Important Notes:
Do not unscrew any pre-assembled caps or cord seal to prevent
leakage and failure. Follow local codes and NEC for installation to
avoid injury or damage.
Contact Information:
Phone: 760.931.2910
Email: techsupport@auroralight.com
Address: 2742 Loker Ave. W Carlsbad CA 92010
Website: www.auroralight.com
FAQ:
Q: Can I install the fixture myself without a licensed
electrician?
A: For safety reasons, it is recommended to have a licensed
electrician install the fixture.
Q: What should I do if I encounter a problem with the fixture
after installation?
A: Contact our technical support team at the provided phone
number or email for assistance.
TAOS INSTALL GUIDE
UDW110244
INSTRUCTIONS: 1. To prevent electrical shock, disconnect transformer from
electrical supply and make sure power supply is completely off before
installation. Fixtures should always be installed by a licensed electrician.
2. Place the fixture with CAM-LOC W/SPOOL KIT in the desired wet or dry
location.
3. Run the 2x 20AWG cable to a dry location nearby. Separate the 2 internal
conductors by stripping the large outer insulation first, then strip about ¼”
off the end of each individual conductor (see figure).
4. Neatly wrap any excess cable around the base of the spool kit. Leave
enough slack at the fixture to allow it to still rotate (see figure).
5. Connect the 20AWG wires to the main supply cable using UL listed
connectors suitable for underground and wet location as well as the
appropriate UL listed underground feeder (UF) cable (see figure).
6. For light aiming, loosen the wing nut and rotate the fixture in the
desired direction. Tighten the wing nut down when finished (see figure).
REQUIRED TOOLS:
3/32″ Allen Key (Included) Wire Cutter / Stripper
MAKE WIRE CONNECTION IN UNDERGROUND OR DRY LOCATION
UL LISTED WIRE CONNECTOR
FIXTURE
WING NUT
CAM-LOC STAND W/ SPOOL KIT
MAIN SUPPLY CABLE 2X 20AWG CABLE
P. 760.931.2910 E. techsupport@auroralight.com O. 2742 Loker Ave. W Carlsbad CA 92010 W. www.auroralight.com
Important! This fixture is assembled and sealed at the factory, do not unscrew any of the pre-assembled caps or the cord seal. Doing so could result in leakage and failure.
WARNING: Luminaire must be
installed in accordance with local
codes and the National Electrical
Code (NEC). Failure to do so may result in serious injury and or damage to the
luminaire.
WARNING: Risk of electric
shock. Install per NEC Code 680.22(B (6), if listed low voltage luminaires are
to be
located near a pool, spa or fountain.