TIS 5A-6CH-V Power Relay 6 Channels 5 Amps Installation Guide

June 3, 2024
TIS

INSTALLATION MANUAL

TIS POWER RELAY

6 Channels 5 Amps

Model: VLC-6CH-5A

PRODUCT INFORMATION

This product is a power relay switch with electromagnet for lights’ turn ON/OFF or motors’ Open/Close function. It enables smart control over lights, sprinklers, gates, shutters and curtains, fan speed, valves, etc. and is ideal for residential and industrial applications.

PRODUCT SPECIFICATIONS

Output| Number of channels| 6
Nominal voltage| 0 – 230 V AC 50/60 Hz
Nominal current per channel|
Low current| 5 A
Lighting incandescent lamp| 4 A
Motors / Air condition| 3 A
LED and CFL lamp| 1 A
Output switching current| Max switching current| 5A
Max Continues current| 4A
TIS Bus| Number of devices on 1 line| Max. 64
Bus voltage| 12-32 V DC
Current consumption (Normal)| <20 mA / 24 V DC
Current consumption (operation)| <100 mA / 24 V DC
Protection| Reverse polarity protection
Operation| Programming button/LED| For assignment of the physical address
1-6 buttons| Manual ON/OFF & programming
By TIS bus| TIS protocol messages & commands
Programming| Manual & via software
Functions| Lighting control ON/OFF| 6 separately controllable channels
Motor setting| Can set 3 groups of curtains (open/close)
Fan speed control| Can set 2 groups of fans (low, med, high)
Dimensions| Width × Length × Height| 76mm × 73mm × 90mm
Housing| Materials| Fireproof ABS
Casing color| Black
Button color| Silver
IP rating| IP 20

TIS 5A-6CH-V - cirti1

Read Instructions

We recommend that you read this Instruction Manual before installation.

Safety instructions

Electrical equipment should only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and other hazards.
These instructions are an integral part of the product and must remain with the end customer.

Programming

This device can be tested and programmed manually. Advanced programming requires TIS Device Search software. Advanced software programming knowledge should be obtained in the advanced training courses.

Simple Installation

DIN Rail mount facilitates installation. Fixing points are provided for installation without the use of DIN rail.

Mounting Location

Install in a dry, well-ventilated location. Controllers may emit some mechanical noise. Take this into account when deciding on a mounting location.

Data Cable

Use screened stranded RS485 data cable with four twisted pairs. Configure devices in a “Daisy Chain.”
Do not cut or terminate live data cables.

Electrical Wires

The installer should adequately consider the total current consumption when selecting the wires.
Recommended wire size for load (light channels) and input wires is 2.5 -4 mm.

Warranty

We provide a warranty as required by law. A hologram warranty seal and product serial number are provided on each device. Please send the description of the defect with Product S/N to our dealer network.

INSTALLATION STEPS

1 Turn off the main electrical source before installation.

WARNING! HIGH VOLTAGE

2 Mount the device on a DIN rail inside an approved enclosure. The device can also be installed without the use of DIN rail by two mounting screw holes.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A06

3 Connect RS485 data cable to the TIS-BUS port as per the connection diagram. No need to loop the TIS-BUS cable if 2 DIN Rail modules are connected together from the side bus train terminal.

  1. To the TIS BUS Network

4 Complete the load connection, light, shutter, and FCU as per the following steps:

****LIGHTS / APPLIANCES / FLOORHEATING CONNECTION

Connect the load electrical wires to outputs 1-6. Each channel can control a maximum of 5A loads. The installer should make sure not to overload the channels.
Load neutral wire should be linked to the neutral connection in DB enclosure.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A08

  1. To the TIS BUS Network
  2. Connect To L
  3. Connect To N
  4. 2.5 mm Electric Cable
  5. 1.5 mm Electric Cable
  6. 1.5 mm Electric Cable
  7. Cat5e connection
    a  GND(white-orange)&(white-brown)
    b  D-(white-green)&(white-blue)
    c  D+(blue-green)
    d  +24V(brown-orange)

![TIS 5A-6CH-V - B13](https://manuals.plus/wp-content/uploads/2022/11

/TIS-5A-6CH-V-B13.png)SHUTTER/CURTAIN CONNECTION

Once you combine any 2 channels as shutter/curtain, then connect the shutter- open wire to the first channel and the shutter-close wire to the second channel. The shutter neutral wire should be linked to the neutral connection in DB enclosure.

WARNING: Do not connect curtain motor wires before combining (interlocking) 2 relay channels together as curtain mode to avoid causing damage to motors. Please read about how to manually program shutter/curtain pairing in this manual.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A09

  1. To the TIS BUS Network
  2. Connect To L
  3. Connect To N
  4. 110 ~ 220 Volt
****FCU Connection

Once you combine any 3 channels as FCU, then connect the FCU (Low, Medium, High) wires to the first, second, and third channels, consecutively. The FCU neutral wire should be linked to the neutral connection of the same section.

WARNING: Do not connect FCU wires before combining (interlocking) 3 relay channels together as FCU mode to avoid causing damage to FCU. Please read about how to manually program FCU pairing in this manual.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A10

  1. To the TIS BUS Network
  2. Connect To L
  3. FCU
  4. LOW
  5. MEDIUM
  6. HIGH

5 Connect the live (supply) wire to inputs. All inputs must have an appropriate voltage source and an MCB to protect that load circuit.

  1. To the TIS BUS Network
  2. Connect To L

6 Turn on the power source, and then test the loads by short pressing on the device’s local override buttons 1-6.

TIS 5A-6CH-V - B16 PAIRING (MANUAL PROGRAMMING)

****LIGHTS/APPLIANCES PROGRAMMING

All channels by default are used for lights/appliances control.
You can pair device light channels to any wall panels by doing the following:

1 Long press on any buttons 1-6 for 6 seconds. The LED indicator for the pressed button will start blinking.

2 Short press on any wall lights buttons on the Luna, Mars, Terre or other panels.

3 Test the button on the panel by short pressing it for ON/OFF.

FLOOR HEATING PROGRAMMING

1 Long press on any buttons 1-6 for 6 seconds. The LED indicator for the pressed button will start blinking.

2 Go to floor heater page on any wall panel with the floor heating function, and press ON button to turn on the floor heating.

3 Test the floor heating by changing the temperature and turning it OFF/ON.

![TIS 5A-6CH-V - B13](https://manuals.plus/wp-content/uploads/2022/11

/TIS-5A-6CH-V-B13.png)SHUTTER COMBINATION PROGRAMMING

You can change any 2 channels in sequence like CH1 and CH2, Ch3 and CH4, Ch5 and CH6 to be combined (interlocked) together to work as shutter/curtain control.
To combine these 2 channels, complete the following steps manually:

1 Press the PRG button for 3 seconds until the LED starts blinking rapidly.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A19

2 Short press on the first button and then the second button that you want to combine as curtain control; for example, CH3 and CH4.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A20

3 Wait for few seconds until the PRG LED stops blinking.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A21

4 Test by turning the first button ON and then the second button. Both buttons should not turn ON together. If you see that the first button is turning the other button off, that means that your buttons are successfully combined as shutter/curtain mode.

5 To program the curtain to any wall panel, press and hold the CH (Shutter-Open) button for 6 seconds. The LED indicator of the pressed button will start blinking,

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A23

6 Short press on any button on the Luna, Mars, Terre or others wall panels.

7 Test the button on the panel by short pressing for open/stop. Do the same to program the Close channel with another button.

  1. Open
  2. Close

8 To cancel the curtain interlock and return to lighting mode, repeat steps 1-3 above.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A26

FCU COMBINATION PROGRAMMING

You can change any 3 channels in sequence like CH1-3 and CH4-6, to be combined (interlocked) together to work as FCU (Low, Medium, High).
To combine these 3 channels complete the following steps manually:

1 Press the PRG button for 3 seconds until the LED starts blinking rapidly.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A27

2 Short press on first button then second button then third button that you want to combine as FCU, as example CH4-6.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A28

3 Wait for a few seconds until the PRG LED stops blinking.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A29

4 Test by turning the first button ON, then the second button, and then the third button. The buttons should not turn ON together. If you see that any button you turned ON is turning the other 2 buttons OFF, that means your buttons are successfully combined as FCU mode.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A30

5 To program the FCU to any wall thermostat panel, press and hold the first Channel L (LOW) button for 6 seconds. The LED indicator of the pressed button will start blinking,

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A31

6 Go to the air conditioning page in your Luna TFT, Mars AC, Terre AC , or other thermostat panel, and turn the AC ON.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A32

7 Test your air conditioning by changing the fan speed from low to medium to high. Your relay should respond accordingly.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A33

8 To cancel the FCU interlock and return back to lighting mode, repeat steps 1-3 above.

TIS 5A-6CH-V Power Relay 6 Channels 5 Amps A34

TROUBLESHOOTING

PRG Button Blinks Red Color Rapidly| Reason: The module’s address conflicts with another device in the TIS network. You need to press and hold the PRG button for 6 seconds so the module can get a new address.
---|---
Device PRG LED is not Blinking; Device not Powered| Reason: Device is not powered on; no TIS-BUS 24V supply connected to the device.
Device Button LED ON but lights not ON| Reason1: Lights’ neutral wire not connected.
Reason2: Channel protection delay time is enabled in software.
Wall Panels can’t Pair with the Device| Reason1: TIS-BUS connection has a problem; check the wires and make sure there’s not a short in the connection.
Reason2: Manual programming function disabled in the device (default is enabled).
Wall Panels can’t Control the Device Channels| Reason 1: TIS-BUS connection has a problem; check the wires and make sure there’s not a short in the connection.
Reason 2: Programming address is wrong.
Channel is turning off by itself after few seconds| Reason: It is programmed as shutter/curtain combination, and running time is enabled in the software.

Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.

TIS CONTROL PTY LIMITED
SA , AUSTRALIA

TIS CONTROL LIMITED
Wanchai, Hong Kong

[www.tiscontrol.com](http://www.tiscontrol.com)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals