AURA LIGHT G4 600 Opti T8 Long Life Light Installation Guide

September 25, 2024
AURA LIGHT

AURA LIGHT G4 600 Opti T8 Long Life Light Installation Guide

WARNING

Parts list: LED T8 CCG Compatible Tube, Installation Instructions, LED Starter.

Please read the installation instruction carefully and follow instructions to ensure safety.

The LED tube is only suitable for 50/60 Hz operation as described at the pictogram.

Only to apply in dry indoor usage and environments, outdoor applications requires an IP rated fixtures.

LED lamp must be installed by a professional electrician.

Once it is installed, do not change any components or structure of LED lamp.

This lamp is designed for general lightning service (excluding e.g. explosive atmospheres).

Ambient Temperature (TA) -20 °Ct o 50 °C (-4 °F to 122 °F).

This lamp may not suitable for use in all applications wehere a traditional fluorescent lamp has been used. The temperature range of this lamp is more restricted. In case of doubt regarding the suitabillty of the application the manufacturer of this lamp should be consulted.

No modifications of the luminarie which the LED lamp is to be used with are to be made.

This lamp is designed to replace:
– 600mm: T8 G13 18W
– 1200mm: T8 G13 36W
– 1500mm: T8 G13 58W

Specification

Lenght (mm)| Bas| Power (w)| Voltage (V)| Input Current (mA)| Colour temperatur (K)
---|---|---|---|---|---
600| G13| 6,7| 220-240| 32| 3000 / 4000 / 5000
1200| G13| 12,9| 220-240| 61| 3000 / 4000 / 5000 / 6500
1200| G13| 15,3| 220-240| 70| 3000 / 4000 / 5000
1500| G13| 18,8| 220-240| 87| 3000 / 4000 / 5000 / 6500
1500| G13| 24,1| 220-240| 108| 3000 / 4000 / 5000

Series connected lamps require AC direct rewiring (Typically in 600mm installations).

Switch off the electricity.

Rotate the lamp 90°.

Remove the conventional lamp.

Remove the starter.

Click the LED replacement starter into the starter holder.

Insert the LED lamp into the lampholder.

Secure the position by turning the lamp by 90°.

Switch on electricity.

Check that the light switches on.

Aura Light AB, Sweden
Phone customer service +46 (0)20 32 30 30
info@auralight.com, www.auralight.com