Specifications
- Reference Impedance: 600ohms
- Insertion Loss @ 1 kHz: Less than 0.5 dB
- Insertion loss:
- 1KHz: Less than 0.25dB
- 120KHz ~ 170KHz: Less than 3dB
- 170KHz ~ 20MHz: Less than 1.5dB
- 36MHz ~ 212MHz: Greater than 55dB
- DC Voltage: 0V~105V
- Return Loss:
- 300Hz~500Hz: Greater than 14 dB
- 500Hz~2000Hz: Greater than 18 dB
- 2000Hz~3400Hz: Greater than 14 dB
- Isolation:
- 30KHz: Greater than 65dB
- 138KHz ~ 150KHz: Greater than 55dB
- 150KHz ~ 1.1MHz: Greater than 65dB
- 1.1MHz ~ 212MHz: Greater than 55dB
- DC Loop Current: Less than 100mA
- Longitudinal Conversion Loss:
- 3.4KHz ~ 30KHz: Greater than 40dB
- 30KHz ~ 1104KHz: Greater than 55dB
- 1104KHz ~ 12MHz: Greater than 50dB
- 12MHz ~ 212MHz: Greater than 40dB
- DC Resistance: Less than 25
- Isolation Resistance: Greater than 5M
- Delay Distortion: Less than 50uS
Product Usage Instructions
Installation
This G.Fast / G.hn Master Filter/Splitter is designed for easywithout the need
for tools. Follow these steps:
- Identify the location where you want to install the filter/splitter.
- Connect the filter/splitter to the appropriate wall socket or telephone line.
- Ensure the connections are secure and the device is properly grounded.
- You can now connect your ADSL, VDSL, or other compatible devices to the filter/splitter for optimized performance.
Frequently Asked Questions (FAQ)
Q: Is this filter/splitter compatible with all types of DSL connections?
A: Yes, this filter/splitter is compatible with ADSL, ADSL2, ADSL2+, VDSL, and
VDSL2 connections.
Fast /G.hn Master Filter/Splitter, 30u”
- RoHS Compliant
- Toolless easy installation
- Compact enclosure
- High quality low pass filter
- Optimum performance
- Removes radio interference on the line
- ADSL, ADSL2, ADSL2+, VDSL, VDSL2 Compatible
Specifications
- Reference Impedance 600ohms
- Insertion Loss @ 1 kHz
- Less than 0.5 dB
Insertion loss
- 1KHz < 0.25dB
- 120KHz ~ 170KHz < 3dB
- 170KHz ~ 20MHz < 1.5dB
- 36MHz ~ 212MHz > 55dB
- DC Voltage 0V~105V
Return Loss
- 300Hz~500Hz > 14 dB
- 500Hz~2000Hz> 18 dB
- 2000Hz~3400Hz> 14 dB
Isolation
- 30KHz > 65dB
- 138KHz ~ 150KHz > 55dB
- 150KHz ~ 1.1MHz > 65dB
- 1.1MHz ~ 212MHz > 55dB
- DC Loop Current
- < 100mA
Longitudinal Conversion Loss
- 3.4KHz ~ 30KHz > 40dB
- 30KHz ~ 1104KHz > 55dB
- 1104KHz ~ 12MHz > 50dB
- 12MHz ~ 212MHz > 40dB
DC Resistance
< 25 Ω
Isolation Resistance
5MΩ
Delay Distortion
< 50uS