TELRAN 560756 Standalone Access Control User Manual

June 4, 2024
TELRAN

TELRAN-560756-Standalone-Access-Control-LOGO

TELRAN 560756 Standalone Access Control

TELRAN-560756-Standalone-Access-Control-PRODUCT-IMAGE

Standalone Access Control

Please read the user manual carefully before installation.

INTRODUCTION

This product is a contactless EM proximity card standalone access control. It adopts zinc-alloy case, anti-vandal and anti-explosion, 2,000 user capacity and supporting access by card, card + PIN, card or Plink. It can be installed on 86x86mm mount box.

Features and Benefits

  • Zinc-alloy housing, anti-vandal, anti-explosion
  • Waterproof, conforms to IP54
  • User capacity::
  • Length of PIN: 4-8 digits
  • Wide voltage input: DC 10-24V
  • Supporting block enrollment with cards sequentially numbered
  • Pulse Mode, Toggle Mode
  • Can be installed on 86mmx86mm box, very easy to install
  • Admin can add/delete admin cards, making add/delete cards rapidly.

Specifications

Operating Voltage 10-24V DC
Working Current ≤ 80mA
Weatherproof IP54
Read Range ≤ 6cm
User Capacity 2000
Card type EM Card
Card Frequency 125KHz
Lock Output Load ≤ 2A
Operating Temperature -40°C~+70°C,(-40°F~158°F)
Operating Humidity 10%~98%RH
Dimensions L110xW76xH22mm(Wide)
Unit Weight 436g
Shipping Weight 500g

TELRAN-560756-Standalone-Access-Control-01

INSTALLATION

  • Remove the back cover from the unit with screw.

  • Drill hole on the wall according to the back size of the machine and fix the back cover to the wall.
    (or fix the back cover firmly to the 86cm×86cm box)

  • Thread the cable through cable hole, connect related cable.

  • For the un-used cable please separate with insulating tape.

  • After wiring, install front casing to the back casing and fix well.TELRAN-560756-Standalone-Access-Control-02

Wiring

Wire Color Function Notes
Green NC Relay NC
Brown COM Relay COM
White NO Relay NO
Black GND Negative Pole
Red DC+ 10-24V DC Power Input
Yellow OPEN Connect to Exit button and the Exit button is connected to GND

Sound and Light Indication

Operation Status Light Buzzer
Stand by Red light bright
Enter programming mode Red light shines
In the programming mode Orange light bright
Open lock Green light bright One beep
Operation failed 3 beeps

Factory  Default testing sanddab discards
Power off, press exit button, power on, release it until hear two beeps. Swiping two cards, the first card is “Admin Add Card”, the second card is “Admin Delete Card”, then the device will be in standby mode. Resets to factory default setting and adding admin cards are successful. If you don’t need to add admin cards: Power off, press exit button, power on, release it until hear two beeps, and the orange LED turn on. Waiting for ten seconds, there is a beep and it will be in standby mode. Resets to factory default setting is successful. Reset to factory default, the users’ information won’t be deleted.

STANDA LONEMODE

Connection Diagram
Special Power Supply for access control systemTELRAN-560756-Standalone-
Access-Control-03

Common power supply
Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is included in the packing).TELRAN-560756-Standalone-Access-Control-04

Add/Delete Users by Admin Card

Using Admin Cards to add delete card users

Add users| Step 1: Read Admin Add Card Step 2: Read user cards (Repeat step 2 for additional user cards) Step 3: Read Admin Add Card again to end
Delete users| Step 1: Read Admin Delete Card)
Step 2: Read user cards (Repeat step 2 for additional user cards) Step 3: Read Admin Delete Card again to end
Quick S ta r t a nd Operation

Quick Settings
** Enter the Programming Mode| *** T – Admin C ode – # e hen you can do the
programming (Factory default is 777777)
** Change the Admin Code| 0 – N ew C ode – # – Repeat the N ew C ode –

** (New Code: any 6 digits)

Add Card User| 1 – Read Card – # (Cards can be added in continuously)
Add PIN User| 1 – User I D – # – P IN- # (ID number:1-2000)
Delete User| 2 – Read Card – # (for Card User)
2 – User I D-# (for PIN User)
Exit from the Programming Mode| ***
How to released he door**
Open door by card| (Read Card)
Open door by User PIN| (Users PIN) #
Open door by user card + PIN| (Read Card) (Users PIN) #

Enter and Exit Program mode

Programming Step Key stroke Combination
Enter Program Mode * (Admin Code) # (Factory default is 777777)
Exit Program Mode *

For safety, the Admin must change the Admin code.

Modify Admin Code

Programming Step Key stroke Combination L E D
Enter Program Mode * (Admin Code) # Red shines
Update Admin Code 0 (New Admin Code) # (Repeat New Admin Code) # (Admin Code
is any 6 digits) Orange bright
Exit Program Mode * Red bright

The length of the admin code is 6 digits, the admin should keep it in mind

Add Users by Keypad ( ID N umber: 1-2000)

Programming Step Keystroke Combination L E D
Enter Program Mode * (Admin Code) # Red shines

Add Card User
Add Card: by Card
O R Add Card: by ID number
O R Add proximity cards sequentially numbered| 1 (Read Card) #
1 (Input ID number) # (Read Card) #
8 (ID number) # (8/10 digits card number) # (The number of cards)#| Orange bright
Add PIN users| 1 (ID Number) # (4-8 digits PIN)| Orange bright
Exit Program Mode| *| Red bright

NOTE

  1. When swiping cards to add users, the user ID will be added in automatically, and ID number will be from small to big, ranged from 1 – 2000.

  2. When adding card users, an attached PIN 1234 will be added in This pin cannot used to open door.
    If you want to open door by card + PIN, you should first change the old PIN 1234, method referring to Change PIN.

  3. Before add the proximity cards sequentially numbered, the ID number should be sequential and

Delete Users by Keypad

Programming Step Keystroke Combination L E D
Enter Program Mode * (Admin Code) # Red shines

Delete Card User-Common
Delete Card – By Card
O R Delete Card –
By ID number| 2 (Read Card) #
2 (Input ID number) #| Orange bright
Delete All User| 2 0000 #| Orange bright
Exit Program Mode| *| Red bright

Pulse Mode and Toggle Mode Setting

Programming Step Keystroke Combination L E D
Enter Program Mode * (Admin Code) # Red shines
Pulse Mode 3 (1-99) # Orange bright
Toggle Mode 3 0 #
Exit Program Mode * Red bright

Note: 1. Factory default is Pulse Mode and the access time is 5 seconds. When set the access time to “0”, the device will be in Toggle Mode.

  1. Pulse Mode: The door will be closed automatically after opening the door for a
  2. Toggle Mode: Under this mode, after opening the door, the door won’t be closed automatically until next valid user That is to say, whether open or close the door, you must swipe valid card or input valid PIN.

Access Mode Setting

Programming Step Keystroke Combination L E D
Enter Program Mode * (Admin Code) # Red shines
Open door by card 4 0 #

O R
Open door by card + PIN| 4 1 #| Orange bright
O R| |
Open door by card or PIN| 4 2 # (Factory default)|
Exit Program Mode| *| Red bright

Alarm Output Time Setting

Programming Step Keystroke Combination L E D
Enter Program Mode * (Admin Code) # Red shines
Set alarm time 6(1-3) # Orange bright
Exit Program Mode * Red bright

Note:

  1. Factory default is 1 minute.
  2. Alarm output time includes: the alarm time of anti-vandal, safe mode and closing
  3. Swipe valid card or Input valid PIN can remove the alarm

Set Safe Mode

Programming Step Keystroke Combination L E D
Enter Program Mode * (Admin Code) # Red shines
Normal Mode 7 0 # (Factory default)
OR Lockout Mode 7 1 # Orange bright
O R
Alarm output Mode 7 2 #
Exit Program Mode * Red bright

Note:

  • Lock out Mode : If swipe card/input PIN with invalid users for 10 times in 1 minute, the device will be lockout for 10 minutes. When the device repowered, the lockout will be canceled.
  • Alarm Output Mode : If swipe card/input PIN with invalid users for 10 times in 1 minute, the buzzer built-in will be activated.

Users Setting

Change PIN

Programming Step Keystroke Combination
Change PIN which attached to card users * (Read Card) (old PIN) # (New PIN) #

(Repeat New PIN) #
Change independent PIN| * (ID number) # (old PIN) # (New PIN) #
(Repeat New PIN) #

Note: The PIN can be changed to any one 4-8 digits, but cannot  be ‘1234’, and the PIN attached to the card is only used for card + PIN access mode.

How to released he door

Open door by card (Read Card)
Open door by User PIN (Users PIN) #
Open door by user card + PIN (Read Card) (Users PIN) #

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals