TELRAN 560918 Easy Keypad with Outdoor Doorbell User Manual
- June 4, 2024
- TELRAN
Table of Contents
TELRAN 560918 Easy Keypad with Outdoor Doorbell
Easy Keypad with Doorbell (Outdoor)
INTRODUCTION
The device is a single door multifunction standalone access control. It uses Atmel MCU assuring stable performance. The operation is very user-fiiendly, and low-power circuit makes it long service life. The device supports 1,000 users (990 common users+ 10 visitor users). It supports multi access modes in card access, PIN access, card+ PIN access, or multi cards/PINs access. The device with ‘remote control’ function is optional (Remote control to open the door remotely).
Features
- Waterproof, conforms to IP66
- Metal case, anti-vandal
- One relay, 1,000 users (990 common + 10 visitor)
- PIN length: 4-6 digits
- Card Type: 125Khz EM Card/13.56Mhz Milare Card (optional)
- Card block enrollment
- Tri-<:elor LED status display
- Pulse mode, Toggle mode
- Built-in light dependent resistor (LDR) for anti tamper
- Backlit keypad, can set automatic OFF after 20 seconds
Specifications
User Capacity
Common User
Visitor User
| 1000
990
10
---|---
Operating Voltage
Working Current Idle Current
| 12-18VDC
-.1oomA
-.somA
Proximity Card Reader
Radio Technology Read Range
| EM orMifare 125KHz 113.56MHz
2-Scm
PIN Length| 4-6digits
Wiring Connections| Relay Output, Exit Button
Operating Temperature Operating Humidity| -40’C – so·c (-40°F -14o•F)
0%RH-98%RH
---|---
Physical Colour Dimensions
Unit Weight Shipping Weight
| Zinc-Alloy
Silver
L117.5xW66x H19 (mm)–Wide
L145xW52xH21 (mm)–Slim
420g — Wide, 430g — Slim 500g — Wide, 510g–Slim
Carton Inventory
INSTALLATION
- Remove the back cover from the unit
- Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
- Knock the supplied rubber bungs to the screw holes(A,C)
- Fix the back cover finnly on the wall with 4 flat head screws
- Thread the cable through the cable hole(B)
- Attach the unit to the back cover
Basic Configure
Enter and Exit Program Mode
Enter Program Mode| * (MasterCode)#
(Factory default is 123456)
---|---
Exit Program Mode| *
Set Master Code
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | * (MasterCode)# |
2. Update Master Code
| 0 (New Master Code)# (Repeat New Mastar Code)#
(Mastercode is any6 digits)
3. Exit Program Mode| *
Connection Diagram
Common Power Supply
Attention: Install a 1 N4004 or equivalent diode is needed when use a common power supply, or the keypad might be damaged. (1 N4004 is included in the packing)
Access Control Power Supply
Programming
Programming will be varied depending on access configuration. Follow the instructions according to your access configuration.
Notes:
- User ID number: Assign a user ID to the access card/ PIN in order to track it.
The Common User ID:
PIN/Card user ID: 0-989
Visitor User ID: 990 – 999
IMPORTANT : User IDs do not have to proceed with any leading zeros. Recording of the User ID is critical. Modifications to the user require the User ID be available.
- Proximity card: 125KHz EM card or 13.56MHz Mifare card
- PIN: Can be any 4-6 digits except 8888 which is reserved.
Add Common Users
PIN/ Card user ID: 0-989; PIN length: 4-6 digits except 8888
Tips for PIN Security (Only valid for 6 digits PIN):
For higher security we allow you to hide your correct PIN with other numbers
up to a max of 10 digits.
Example PIN: 123434
You could use *(123434) •• or•• (123434) (“‘· can be any numbers from 0-9)
Add Visitor Users
(User ID number is 990-999; PIN length: 4-6 digits except 8888) There are 10
groups Visitor PIN/card available, the users can be specified up to
10timesofusage, after a certain number of times, i.e. 5times, the PIN/card
become invalid automatically.
Programming Slap | Keystroke Combination |
---|---|
1. Enter Program Mode | • (Master Code)# |
2.Add Card
OR
2.Add PIN
| 1 (User ID)# (0-9) # (Raad Card)/ (Input 8/10/17 DlgHs Card Number)#
1 (User ID)# (0-9) #(PIN)#
(0-9means times of usage, 0=10 times)
3.Exit| *
Change PIN Users (PIN length: 4-6 digits except 8888)
Programming Slap | Keystroke Combination |
---|
Note: Below is done outside programming mode, users can undertake this themselV88
Change PIN
| * (User ID)# (Old PIN)# (New PIN)# (Repeat New PIN)#
Change PIN of Card+ PIN access
mode (There will auto allocate PIN (8888) to cards when adding)
| • (Raad Card) (Old PIN)# (New PIN)# (Repeat New PIN)#
Delete Users
Programming Slap | Keystroke Combination |
---|---|
1. Entar Program Mode | * (MasterCode)# |
2. Delete User- By Card/ PIN
OR
2. Delete User- By ID number
OR
2. Delete User- By Gard number
OR
2. Delete ALLUsers
| 2 (Read Card)/(lnput PIN)#
The users can be deleted continuously.
2(UserlD)#
2 (Input 8/10/17 Digits Card Number)# 2(MasterCode)#
3.Exit| *
Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.
• (Master Code)#
|
---|---
2. Pulse Mode
OR
2. Toggle Mode
| 3 (1-99) #(factory default) The relay time is 1-99 seconds. (Default is 5 seconds)
30#
Sets the relay to ON/OFF Toggle mode
3.Exit| *
Set Access Mode
For Multi-user access mode, the interval time of reading can not exceed 5
seconds, or else, the device will exit to standby automatically.
|
---|---
1. Entar Program Mode| • (Master Code)#
2 Card Access| 40#
OR|
2 PIN Access| 41#
OR|
2 Card+ PINAccess| 42#
OR|
2 Card orPINAccess| 4 3 # (factory default)
OR|
2 Multi User Access| 43 (2-9)#
(Only after 2-9 valid users, the door
| can be opened)
3.Exit| *
Optional Access Mode: Remota Control
(Only valid for the device with ‘Remota Control’ function)
Step 1: Add the remote control:
Enter Program Mode — Press 4 5 #, the device will give one beep– Press the
Open Key on the remote control once —- Press* to exit
Step 2: Open 1he door by remote control:
Simply press the Open Key on the remote control
Note:
- The device with ‘Remote Control’ function can add 4pcs of remote controls maximum.
- There is an extra signalreceipt antenna on the device, no need to connect.
- The Close Key on the remote control is useless.
Set Strike-out Alarm
The strike-out alarm will engage after 10 failed entry attempts (Factory is
OFF). It can be set to deny access for 10 minutes after engaging or disengage
only after entering a valid card/PIN or Master code/ card.
Programming Slap | Keystroke Combination |
---|---|
1. Enter Program Mode | * (l\llasterCode)# |
2. Strike-Out OFF
OR
2. Strike-Out ON
OR
2. Strike-Out ON (Alarm)
Set Alarm Time
| 8 0 # (factory default)
81 # Access will be denied for1Ominutes
(Exit button is still workable)
62#
5 (0 -3) # (factory defaullis 1 minute)
Enter Master Code# or Master Card or valid user card/PIN tosilence
3.Exit| *
Master Card Usage
Using Master Card to add and delete users
Add Gard I PIN Users
| 1. Input (Master Card)
2 . Input (Card) or (PIN)
Repeat step 2 for addition
3. Input (Master Card)
Delete Card I PIN Users
| 1 . Input (Master Card within 5s)
2 . Input (Card) or (PIN
Repeat step 2 to add
3. Input (Master Card)
Users Operation & Reset to Factory Default
- Open the door: Read valid user card or input valid user PIN#
- Remove Alarm: Enter Master Code# or Master Card or valid user card/PIN#
- To reset to factory default &Add Master Card: Power off, press the Exit Button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card/ 13.56 MHz Milare card, the LED will tum into red, means reset to factory default successfully. Of the card reading, it is the Master Card.
Remarks:
CD If no Master Card added, must press the Exit Button for at least 5 seconds before release.(this will make the previous registered Master Card invalid) Reset to factory default, the user’s information is still retained.
Phone: 03-5575110
office@telran.co.il
Documents / Resources
|
TELRAN 560918 Easy Keypad with Outdoor
Doorbell
[pdf] User Manual
560918 Easy Keypad with Outdoor Doorbell, 560918 Easy Keypad, Easy Keypad with
Outdoor Doorbell
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>