Xiamen EVM002 Series Electric Vehicle AC Charger User Manual
- September 16, 2024
- Xiamen
Table of Contents
EVM002 Series Electric Vehicle AC Charger
“`html
Specifications
-
POWER
- Input Rating: 208~240V AC
- Output Current & Power: 11.5 kW (48A), 19.2 kW (80A)
- Power Wiring: L1 / L2 / GND
- Input Cord: Hard-wire
- Mains frequency: 50 / 60 Hz
- Connector Type: SAE J1772 Type1
- Ground Fault Detection: CCID 20
-
Protection
- UVP, OVP, RCD (CCID 20), SPD, Ground Fault Protection, OCP,
OTP, Control Pilot Fault Protection
- UVP, OVP, RCD (CCID 20), SPD, Ground Fault Protection, OCP,
-
User Interface
- Status Indication: LED indication
- Screen: 4.3′ touch screen (UI upgradable)
- Language: English / Spanish / French
- User Interface Connectivity: Compatible with multiple CPOs,
Bluetooth5.2, Wi-Fi (2.4G / 5G), Ethernet, 4G (optional)
-
Communication Protocols
-
OCPP2.0.1 / OCPP 1.6Js self-adaptation
-
Pile Group Management: ISO15118-2/3
-
User Authentication: RFID Card, OCPP RFID, ISO14443A,
ISO14443B, 13.56MHz -
Software Update: OTA
-
-
CERTIFICATION & STANDARDS
-
Safety & Compliance Certification: UL991, UL1998, UL2231,
UL2594, ISO15118 (P&C) -
Warranty: ETL / FCC / Energy Star 36 months
-
-
GENERAL
-
Button: Emergency Button
-
Enclosure Rating: NEMA 4 (IP65), IK08
-
Operating Altitude, Temperature, Humidity: as per
specifications -
Mounting: Wall-Mounted
-
Product Dimensions: as per specifications
-
Product Usage Instructions
1. Verify Contents
Ensure you have the installation guide and the following
parts:
-
Electric Vehicle AC Charger EVM002 Series (NA) – User
Manual -
Holster Bracket
2. Gather Tools
Tools required before installing the Wall-Mounted charger:
-
Wire stripper
-
Adjustable Wrench
-
Voltmeter or digital multi-meter (for measuring AC voltage at
the installation site) -
Level
-
Pencil or marker
-
Drill
-
Phillips screwdriver
3. Plan The Mounting
WARNING: In areas with frequent thunderstorms,
add surge protection at the service panel for all circuits. Ensure
all power and ground connections, especially those at the breaker
and bus bar, are clean and tight.
CAUTION: Not recommended to be installed in
coastal environments with high humidity or high dust.
Frequently Asked Questions (FAQ)
Q: What should I do if the LED status indication is not
working?
A: If the LED status indication is not functioning properly,
check the power supply connection and ensure that the charger is
receiving adequate power.
Q: Can I use the charger in extreme weather conditions?
A: It is not recommended to use the charger in extreme weather
conditions such as heavy rain or snow. Ensure the charger is
installed in a sheltered location.
Q: How often should I perform maintenance on the charger?
A: Daily maintenance is recommended to ensure optimal
performance of the charger. Check for any visible damage or loose
connections regularly.
Q: How can I update the software of the charger?
A: Software updates can be performed using Over-The-Air (OTA)
methods. Refer to the user manual for detailed instructions on
software updates.
“`
Electric Vehicle AC Charger
EVM002 Series (NA) – User Manual
1. 142 x 210 mm
70g
108g
6.B
7.mm
2024.07.12
EVM002 Series (NA)
1:1
Electric Vehicle AC Charger
EVM002 Series (NA) – User Manual
Version 1
USER MANUAL
USER MANUAL
TABLE OF CONTENTS
1. IMPORTANT SAFETY INSTRUCTIONS …………………………….. 1 2. PRODUCT
INTRODUCTIONS…………………………………………… 5 3. VERIFY CONTENTS………………………………………………………… 8 4.
GATHER TOOLS …………………………………………………………….. 9 5. PLAN THE MOUNTING
………………………………………………….. 10 6. WALL MOUNTING…………………………………………………………. 11 7. WIRE
THE CIRCUIT AND INSTALL 4G CARD………………….. 14 8. LIGHT CODES
………………………………………………………………. 18 9. FCC DECLARATION ……………………………………………………… 20 10.
WARRANTY AND MAINTENANCE………………………………… 21
USER MANUAL WARNING & CAUTION
1. Important Safety Instructions
1.1 Overall Warnings & Cautions
WARNING: To avoid fire, injury or death, carefully read and follow the
instructions during installation, operation and maintenance. – DO NOT put
fingers into the electric vehicle connector. – DO NOT use this product if the
flexible power cord or EV cable is frayed, insulation-broken, or any other
signs of damage. – DO NOT use this product if the enclosure or the EV
connector is broken, cracked, open, or shows any other indication of damage. –
DO NOT remove cover or attempt to open the enclosure because of risk of
electric shock. WARNING: This device should be supervised when used around
children. WARNING: This device must be grounded. WARNING: To avoid a risk of
fire or electric shock, do not use this device with an extension cord.
WARNING: The suitability of the use of flexible cord in accordance with CE
code, part I, rule 4-012, is to be determined by the local inspection
authority. WARNING: To reduce the risk of fire, connect only to a circuit
provided branch circuit over-current protection in accordance with the CSA
C22.115 Canadian Electrical Code, Part 1 (Canada) or NOM-001-SEDE Electrical
installations (utility) (Mexico) or ANSI / NFPA 70 National Electrical Code
(USA).
Circuit Breaker Options table
Output Amperage (A)
16A
32A
40A
48A
Circuit Breaker Options (A)
20A
40A
50A
60A
70A
80A
90A
100A
1
WARNING & CAUTION
USER MANUAL
1.2 Installation Requirements
WARNING: Disconnect electrical power prior to installing the charging station.
WARNING: Be sure to preview the user manual and ensure local building and
electrical codes are reviewed before installing the AC charger. WARNING: The
AC charger should be installed by a qualified technician according to the user
manual and local safety regulations. CAUTION: Use appropriate protection when
connecting to the main power distribution cable. CAUTION: Type B, C or D
breaker with the rating current for table should be installed in the upstream
AC distribution box. CAUTION: The device shall be mounted at height between 2
feet and 4 feet from ground. CAUTION: Please keep the charger in a clean area
with low humidity. Not recommended to be installed in coastal environments
with high humidity or high dust.
1.3 Daily Maintenance
CAUTION: Avoid moisture or water in the charger. If there is water or moisture
ingress in the charger, it is necessary to immediately power off to avoid
immediate danger, and notify the professionals to carry out maintenance before
next use. CAUTION: Please use the charger properly. Do not hit or press hard
on the enclosure. If it is damaged, please contact a professional technician.
CAUTION: Avoid placing the charger near hot objects and at high temperature
locations and away from dangerous substances such as flammable gases and
corrosive materials. CAUTION: Do not put heavy objects on the charger to avoid
danger.
2
USER MANUAL WARNING & CAUTION
Consignes De Sécurité Importantes
1.1 Avertissement & Mise En Garde Généraux
AVERTISSEMENT : Pour éviter les risques d’incendie, de blessure ou de mort, il
faut lire et suivre soigneusement les instructions pendant l’installation,
l’utilisation et l’entretien. – Ne mettez pas les doigts dans le connecteur du
véhicule électrique. – N’utilisez pas ce produit si le cordon d’alimentation
flexible ou le câble EV est effiloché, isolé ou présentant tout autre signe de
dommage. – N’utilisez pas ce produit si le boîtier ou le connecteur EV est
cassé, fissuré, ouvert ou montre toute autre indication de dommage. Ne retirez
pas le couvercle et n’essayez pas d’ouvrir le boîtier en raison du risque de
choc électrique. AVERTISSEMENT : Cet appareil doit être surveillé lorsqu’il
est utilisé à proximité d’enfants. AVERTISSEMENT : Cet appareil doit être mis
à la terre. AVERTISSEMENT : Pour éviter tout risque d’incendie ou de choc
électrique, n’utilisez pas cet appareil avec une rallonge électrique.
AVERTISSEMENT : L’adéquation de l’utilisation du cordon flexible conformément
au code ce, partie i, règle 4-012, doit être déterminée par l’autorité
d’inspection locale compétente. AVERTISSEMENT : Pour réduire les risques
d’incendie, ne connecter qu’à un circuit protection contre les surintensités
des circuits de dérivation conformément à la norme canadienne CSA C22.1-15
Code électrique, partie 1 (Canada) ou NOM-001-SEDE Installations électriqu
(Mexique) ou ANSI / NFPA 70 National Electrical Code (États-Unis).
Circuit Breaker Options table
Output Amperage (A)
16A
32A
40A
48A
Circuit Breaker Options (A)
20A
40A
50A
60A
70A
80A
90A
100A
3
WARNING & CAUTION
USER MANUAL
1.2 Exigence Avant L’installation
AVERTISSEMENT : Assurez-vous de consulter le manuel d’utilisation et assurez-
vousque les codes locaux du bâtiment et de l’électricité sont passés en revue
avant d’installer le chargeur. AVERTISSEMENT : Débranchez l’alimentation
électrique avant d’installer la station decharge. AVERTISSEMENT : Le chargeur
CA doit être installé par un technicien qualifié conformément au manuel
d’utilisation et aux réglementations de sécurité locales. MISE EN GARDE :
Utilisez une protection appropriée lors de la connexion au câble de
distribution d’alimentation principal. MISE EN GARDE : Un disjoncteur de type
B, C ou D avec le courant nominal indiqué dans le tableau doit être installé
dans le boîtier de distribution CA en amont. MISE EN GARDE : Cet appareil doit
être monté à une hauteur entre 2 feet and 4 feet du sol. MISE EN GARDE :
Veuillez conserver le chargeur dans un endroit propre et peu humide. Il n’est
pas recommandé de l’installer dans des environnements côtiers à forte humidité
ou à forte poussière.
1.3 Entretien Quotidien
MISE EN GARDE : Évitez l’humidité ou l’eau dans le chargeur. En cas
d’infiltration d’eau ou d’humidité dans le chargeur, il est nécessaire de
l’éteindre immédiatement pour éviter tout danger immédiat et d’avertir le
personnel professionnel d’effectuer l’entretien avant la prochaine
utilisation. MISE EN GARDE : Veuillez utiliser le chargeur correctement. Ne
frappez pas ou n’appuyez pas trop fort sur le boîtier. Si le boîtier est
endommagé, veuillez contacter un technicien professionnel. MISE EN GARDE :
Évitez de placer le chargeur à proximité d’objets chauds et à des endroits à
haute température et loin de substances dangereuses telles que des gaz
inflammables et des matériaux corrosifs. MISE EN GARDE : Ne placez pas
d’objets lourds sur le chargeur pour éviter tout danger
4
USER MANUAL
2. Product Introductions
CAUTION: Avoid placing the charger near hot objects and at high temperature
locations and away from dangerous substances such as flammable gases and
corrosive materials.
2.1 Basic Interface
LED Light Indication
RFID Swipe Area
Emergency Button
2.2 Basic Dimensions
9.61″ 15.83″
Rear Notch
Charging Cable Inlet LAN Cable Inlet
SAE J1772 AC Charging Connector
Rear AC Power Inlet AC Power Inlet
2.83″ 4.8″
5
USER MANUAL
4.64″
6
USER MANUAL
2.3 Specifications
POWER
Input Rating Output Current&Power Power Wiring Input Cord Mains frequency
Connector Type Ground Fault Detection
Protection
Meter Accuracy USER INTERFACE Status Indication Screen Language User Interface
Connectivity
Communication Protocols
Pile Group Management User Authentication Card Reader Software Update
CERTIFICATION & STANDARDS Safety & Compliance Certification Warranty GENERAL
Button Enclosure Rating Operating Altitude Operating Temperature Storage
Temperature Operating Humidity Mounting Product Dimensions
EVM002
208~240V AC
11.5 kW (48A)
19.2 kW (80A)
L1 / L2 / GND
Hard-wire
50 / 60 Hz
SAE J1772 Type1 18ft / SAE J3400 NACS 18ft (Optional)
CCID 20
UVP, OVP, RCD (CCID 20), SPD, Ground Fault Protection, OCP, OTP, Control Pilot Fault Protection
±1% (CTEP qualified)
LED indication 4.3′ touch screen (UI upgradable)
English / Spanish / French Compatible with multiple CPOs Bluetooth5.2, Wi-Fi
(2.4G / 5G), Ethernet, 4G (optional) OCPP2.0.1 / OCPP 1.6Js self-adaptation
ISO15118-2/3 Dynamic Load Balancing Plug&Charge(Free)aPlug&Charge(PnC)aRFID
CardaOCPP RFID, ISO14443AaISO14443B, 13.56MHz
OTA
UL991, UL1998, UL2231, UL2594, ISO15118 (P&C) ETL / FCC / Energy Star 36 months
Emergency Button NEMA 4 (IP65), IK08
6561ft (2000m) -40°F ~ +131°F (-40°C ~ +55°C) -40°F ~ +185°F (-40°C ~ +85°C)
5 ~ 95% Wall mount / Pedestal (optional) 15.83″×9.61″×4.64″ (402×244×118mm)
7
3. Verify Contents
Ensure you have this installation guide and these parts:
Electric Vehicle AC Charger EVM002 Series (NA) -User Manual
USER MANUAL
AC Charger ×1
User Manual ×1
Wall-Mounted Bracket ×1
M4 Anti-Theft Round Head Screws ×1
M6 Hexagonal Expansion Screws ×4
Allen Wrench ×1
Holster Bracket
Mounting Template ×1
RFID Card ×2
Cable Ramp ×1
ST3.5*16 Screws ×2
AD34.5 Conduit Fitting ×1
AD21.2 Conduit Fitting ×1
M32 Conduit Fitting ×1
8
USER MANUAL
4. Gather Tools
Tools required before installing the Wall-Mounted charger, gather the
following tools: 1. Wire stripper 2. Adjustable Wrench 3. Voltmeter or digital
multi-meter (for measuring AC voltage at the installation site) 4. Level 5.
Pencil or marker 6. Drill 7. Phillips screwdriver
1
2
3
USER MANUAL
5. Plan The Mounting
WARNING: In areas with frequent thunderstorms, add surge protection at the
service panel for all circuits. Ensure all power and ground connections,
especially those at the breaker and bus bar, are clean and tight. CAUTION: Not
recommended to be installed in coastal environments with high humidity or high
dust.
Select the appropriate mounting location with electri calcapacity: I. Ensure
the owner has chosen a mounting location that allows the charging cable to
reach the car’s charging port while still providing slack. II. The device must
be anchored into mounting such as 3.14″ x 5.11″ stud or a solid wall.
4
5
6
7
Note: The above tools are very important, please gather them all.
9
10
USER MANUAL
6. Wall mounting
STEP 1 Make sure the installation wall is vertical, and use the Mounting
template to drill four screw holes with a diameter of 0.33″ (8.5mm) and a
depth of 2.17″~2.36″ (55mm~60mm) at a height of 47.24″~51.18″(1200-1300mm)
from the ground according to the hole positions.
USER MANUAL
STEP 3 Use 4 Hexagonal Expansion Screws to secure the wall-mounted bracket on
the wall, Use an wrench to tighten the screw nuts on the expansion screws.
Wall-Mounted Bracket
47.24″~51.18″ (1200-1300mm)
STEP 2
Ground
Push the bracket down to remove the wall hanger.
STEP 4
Align the rear notch of charger with the wall-mounted bracket and alignment
the screw holes at the bottom, and secure it using M4 Anti-Theft Round Head
Screws.
11
12
USER MANUAL
STEP 5 Overall outlook picture after installation:
Wall-mounted cable winding
Plug holder (optional)
Pedestal (optional)
USER MANUAL
7. Wire The Circuit And Install 4G Card
WARNING: This device must be grounded. Disconnect electrical power prior to
installing the charging station.
WARNING: Improper connection of the equipment-grounding conductor would result
in a risk of electric shock. Check with a qualified electrician or serviceman
if you are not sure whether the product is properly grounded. Do not modify
the plug provided with the product if it doesn’t fit the outlet, have a
proper outlet installed by a qualified electrician.
CAUTION: Use appropriate protection when connecting to the main power
distribution cable.
This step is only to Hard-wire wiring and requires user-supplied AC input cables. For safe use of electricity, please set circuit breaker protection in the input part of EV Charger.
Circuit Breaker Options table
Output Amperage (A)
16A
32A
40A
48A
Circuit Breaker Options (A) 20A
40A
50A
60A
70A
80A
90A
100A
13
14
USER MANUAL
STEP 1
Use a allen wrench to loosen the two screws located at the bottom of the
charging station. Open the buckle on both sides and lift up the front cover to
remove it from the charging station.
STEP 2 Remove the cover from the charger using the appropriate tools. such as coin
STEP 3 Remove the waterproof plug from the charger cable inletConnect and Lock
the M32 Conduit Fitting Part1 ( 1 ) and Part2 ( 2 ) (including the washer) to
the Inlet as shown below. Note: 1.You need to bring your own AC input cable.
2.Select the AD34.5 or M32 Conduit Fitting based on the AC input cable typeIf
you use AD34.5 Conduit Fitting, perform the same steps as above.
15
COCN
L1 L2 GND
1
1
2
3
2
L1 L2 GND
USER MANUAL
STEP 4
Take out the AC input cable and strip the TPU cover by 5.52″ (140mm), and then
strip individual wires by 0.47″ (12mm). use ferrules on stranded wires and
press it by wire crimper. Note: You need to bring your own ferrules.
(ferrules)
5.52″(140mm)
0.47″(12mm)
STEP 5
First, pass the AC input cable through the M32 Conduit Fitting Part 3 ( 3 ),
then continue through Part 1 and Part 2. Connect the wires (L1, L2, GND) and
tighten each connector screw to 2 N.m (17.7 in.lbs).
L1 L2 GND
L1 L2 GND
3
16
USER MANUAL
STEP 6 Lock the M32 Conduit Fitting Part 3 ( 3 ), Press the AC input cable
with cable ramp and secure it with two screws (3.5*16).
L1 L2 GND
L1 L2 GND
3
STEP 7
Remove the waterproof plug from the
charger cable inlet. Connect and lock the
AD21.2 conduit fitting Part1 ( 1 ) and Part2
( 2 ) to the inlet. Then, insert the Ethernet
cable with the RJ45 plug into the bellows,
1
through the AD21.2 conduit fitting, and plug
2
the cable into the RJ45 port (RS232/RS485
operate in the same mode). Note:You need to bring your own bellows
L1 L2 GND
L1 L2 GND
1
2
17
STEP 8 Align the cover with its position on the charging station.Secure the
cover in place using the appropriate tools(such as coin).
STEP 9 Insert the SIM (MICRO SIM) card according to the picture’s instruction
(for 4G version, Optational).
STEP 10 Align the magnetic positions of the cover plate and the middle frame,
Fasten both clips and fix the two screws at the bottom.
8. Light Codes
8.1 After Start UP
Device Status
Power On Standby Plug The Charging Connector Swipe Card Charging In Progress
Finished / Stopped Charging
OTA Fault
USER MANUAL
COCN
Light Codes
Blue, green and red run clockwise Solid Blue Solid Green
Green Blinking Green Breathing
Solid Green Yellow Breathing
Red
18
USER MANUAL
8.2 Error and Warning Messages
No. Fault Status
Red Light
Remark
1 Emergency Fault
Solid Red
Reset Recover
2
Meter Fault
1 flash followed by 3 sec pause
Auto Recover
3
CP Fault
2 flashes followed by 3 sec pause Unplug the Connector to Recover
4
UVP
3 flashes followed by 3 sec pause
Auto Recover
5
OVP
4 flashes followed by 3 sec pause
Auto Recover
6
OTP
5 flashes followed by 3 sec pause
Auto Recover
7
OCP
6 flashes followed by 3 sec pause Unplug the Connector to Recover
8
Ground Fault
7 flashes followed by 3 sec pause Unplug the Connector to Recover
9
Relay Fault
8 flashes followed by 3 sec pause Unplug the Connector to Recover
10
RCD Abnormal
9 flashes followed by 3 sec pause Unplug the Connector to Recover
11 RCD Self-Test Fault 10 flashes followed by 3 sec pause
Reboot to Recover
12 Relay Self-Test Fault 11 flashes followed by 3 sec pause
Reboot to Recover
USER MANUAL
9. FCC Declaration
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: This device may not
cause harmful interference, and this device must accept any interference
received, including interference that may cause undesired operation.
Caution: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment.
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
WIFI module: Containing FCC ID: XMR2023FCS960K LTE module: Containing FCC ID:
XMR202008EC25AFXD
To satisfy FCC RF exposure requirements, a separation distance of 20cm or more
should be maintained between the antenna of this device and persons during
device operation. To ensure compliance, operations at closer than this
distance is not recommended.
19
20
USER MANUAL
10. Warranty and Maintenance
· The warranty period for this charger is three years. · During the warranty
period for any malfunction under normal use according to the User Manual (to
be determined by certified maintenance technicians of sellers), the product
shall be repaired free of charge. Except for the following situations, the
charger shall be subject to the above warranty terms: 1. The warranty
certificate cannot be provided or the contents of the warranty certificate are
modified or inconsistent with the label indication of the repaired product. 2.
Those who are unable to provide valid proof of purchase. 3. Those who exceed
the manufacturer’s specified warranty period. 4. Those who damage the product
due to not following the product service instruction for use, maintenance and
storage. 5. Damage or malfunction caused by external object entering. 6.
Unauthorized repair, disassembly or modification. 7. Damage caused by force
majeure (such as lightning, excessive voltage, earthquake, fire, flood, etc.).
8. Malfunction and damage caused by other unavoidable external factors.
Malfunction and damage caused by improper use of equipment, such as water or
other solutions entering into the equipment. 9. Malfunction and damage caused
by the grid power supply and voltage which is not specified for use with the
charger equipment.
The above guarantees shall be made solely, and no other express or implied
warranties shall be made (including the implied warranties of merchant
ability, particular and applicable reasonableness and adaptability, etc.)
whether in the contract, civil negligence, or other aspects, the Company shall
not be responsible for any special, incidental or consequential damages.
21