EAE UD106 Universal Dimmer Actuator Instructions

September 18, 2024
EAE

EAE UD106 Universal Dimmer Actuator

EAE UD106 Universal Dimmer Actuator

Device Description

EAE KNX Universal Dimmer Actuator has dimming functions which can be used by phase dimming only. The device can be operated manually via push button over enclosure. Each channel can be programmed via ETS5. UD 106 has 6 independent channels and 3 channel grouping features. Channel features of dimming actuator;

  • Staircase lighting
  • Forced Operation
  • Channel Grouping (merging outputs for high power lamps)
  • Scene Function
  • Electrical Measurements (Voltage)
  • Error Detection (Load Error, Short-Circuit, Over-current, Over-voltage, Under-voltage, Over-heating)

All features can be used individually or together.
Device Description

Technical Data

Protection Type IP 20 EN 60 529
Safety class II EN 61 140
KNX Power supply Voltage 21V… 30V DC, SELV
Current consumption < 10 mA
Mains Supply Min…Max 185… 300V AC
Screw terminals 0,5…3,31 mm² solid and stranded wire 0,5…3,31 mm² stranded

wire with ferrule 0.5 Nm
Connections| Max. tightening torque KNX| 0.5 Nm Bus connection terminal
Switching & Dimming| 6 outputs,
Trailing and Leading-Edge Dimming
Cable length| Max. 200 meters
Max. switching power| 300 VA per channel
300 W halogen, incandescent lamps per channel 300 W Inductive transformers per channel
Output| | 250 W Phase-cut dimmable LED lamps per channel 120 W constant voltage drivers Multiplying the output power by parallel connection of channels.
Min switching power| 9 W
Mechanical Life| Lifetime
Type of contact| Electronically controlled
Installation| 35mm mounting rail| EN 60 715
Operating elements| LED (red) and button On/Off Button| For physical address programming For Switching/Dimming lights
Temperature range| Ambient| -5° C + 45° C
Storage| -25° C + 55° C
Humidity| Max. air humidity| 85 % no moisture condensation
Dimensions| L x W x H Width in units (18 mm module| 66 x 180 x 90 mm 10 modules
Box| Plastic, polycarbonate, colour grey
CE| In accordance with the EMC guideline and LV directives
Electrical Installations| EN 60 669-2-1
EMC requirements| EN 63 044-5-2

Operation and Display

-Programming Led (3)
Red led lights up after the programming button is pressed.

-Status Leds
Blinks when error occurred, Stays when switched ON.

Connection Example

Connection Example

Scale Drawings

Scale Drawings

Commissioning

Determination of the physical address and setting of parameters are actualized with Engineering Tool Software (ETS5 or higher). “.knxprod” file must be imported to the ETS. Please check website for latest “.knxprod” file.
www.eaetechnology.com

Icon A detailed information about parameter configuration can be found in Product Manual of device.

Icon Installation and commissioning of device may only be implemented by trained electricians. The relevant standards, directives, regulations and instructions must be observed when planning and implementing the electrical installation.

  • When connecting the device make sure that the device is isolated!
  • Protect the device against moisture, dirt and damage during transport, storage and operation!
  • Do not operate the device out of the specified technical data which is stated.
  • The device may only be operated in closed enclosures (Distribution boards etc.)

Cleaning

If device becomes dirty, only a dry cloth can be used for cleaning. It is not suitable to use wet cloths, caustics and solvents.

Customer Support

© EAE Technology
Ikitelli Org. San. Bolg. Ziya Gokalp Mah. Eski Turgut Özal Cad.
No: 20, Zip Code: 34490 Başakşehir/Istanbul Tel: +90 212 549 97 13
www.eaetechnology.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>