NEUATION iFUGE M08 Micro Centrifuge Manufacturers User Manual
- June 3, 2024
- NEUATION
Table of Contents
iFUGE M08 Micro Centrifuge Manufacturers
NEUATION
TECHNOLOGIES
iFUGE M08
PRODUCT USER MANUAL
1. INTRODUCTION
This Micro Centrifuge offers versatility, simplicity, safety, and ease of usage in a single package. This product has been designed after studying centrifuges and its usage in numerous scenarios of the lab environment.
This Micro centrifuge is specially suitable for microfiltration, cell separations, centrifugal tube sedimentation, and spin down applications. Please read this manual thoroughly before operating the centrifuge.
2. INTENDED USE
This is used in various laboratories to separate particles from suspension or even macromolecules from solutions according to their density. The different biological substances that are usually separated by centrifugation are microbial cells, organelles, proteins, DNA, and RNA.
Note: This user guide is intended to assist with the operation and care of the unit only and not for its repoir. The customer should not attempt to service or repair the unit. lf repairs are required, please contact the supplier.
3. FEATURES
• 8 position micro centrifuge tube rotor
• Electronic safety brake on lid opening for user safety
• Magnetic rotorforeasy tool free changing of rotor
• Starts and stops in seconds
• Lid safety interlock
• Smooth and silent, discreet running
• Small footprint can be fit in hoods & small work places
• Interchangeable magnetic rotors (MCT rotor& PCR rotor)
• Low voltage power consuming device
4. STANDARD ACCESSORIES
1.5/2ml closed rotor, PCR strip rotor
Individual adaptor for 0.5 ml tubes, pack of 8
Individual adaptor for0.1/ 0.2 ml tubes, packof8
Power Adaptor: Input voltage – 100 – 240VAC 50/60Hz
Output voltage: 24V:-:-: 1.SA
Product User Manual, Warranty Card and Declaration Conformity
5. TECHNICAL SPECIFICATIONS
Motor Type
|
DC Motor
---|---
Rotor Capacity
|
8 x 1.5 /2.0 ml Tube Rotor & 2 Place PCR Strip Rotor
Speed
|
6000 RPM
2000 x g (MAX RCF)
Speed Accuracy
|
± 300 RPM
Time
|
NO
Size 0N X D X H)
|
162 x 157 x 116 mm
Weight
|
1.1 kg
Input Voltage
|
24V :-:-: 0.4A
Power Consumption
|
10W
6. SAFETY PRECAUTIONS
-
The personal micro centrifuge is designed to be safe under the following
conditions when operated with necessary precautions mentioned below : -
Indoor use only.
-
Ambient temperature of 4°C to 45°C.
-
Main supply voltage fluctuations not to exceed +/- 10% of the nominal voltage.
-
Position at least 20 cm from walls, 20 cm from ceiling and 20 cm between
other products. -
Make sure to always install the centrifuge on stable flat surfaces only & place
it near the electrical outlet. -
Always load the rotor symmetrically. Each tube should be counterbalanced
by another tube. -
Make sure to always use only specified micro centrifuge tubes made from
plastic and designed to withstand centrifugal forces of at least 2000 g. -
Do not operate the centrifuge without the rotor being properly attached to
the shaft. Re-check by trying to pull it up manually, especially after the rotor
has been changed or re-assembled. -
Do not move the centrifuge while it’s under operation.
-
Do not fill the tubes while they are in the rotor. Liquid spillage may harm the
unit. -
Do not put hands in the rotor chamber unless the rotor has completely
stopped. -
Do not centrifuge flammable, explosive or corrosive materials.
-
Do not use solvents or flammable media near this or other electrical
equipment. -
In case the unit is dropped from the table, please check the casing for any
cracks/damage. -
The centrifuge and its components are non auto cleavable.
-
Do not use the centrifuge in any manner not specified in these instructions.
7. INSTALLATION
POWER SOCKET
This micro centrifuge is supplied in a packaging box. Open the box, then gently remove the centrifuge from the box and plug in the power adaptor pin before connecting to the main power source. The instruction manual and the accessories should be kept with the centrifuge. Please keep all packaging in safe storage for at least 2 years for warranty purposes.
Make sure the rotor is tight to avoid any accident. Load the rotor with the
micro
tubes for centrifugation. Place the ON/OFF switch to “o” front and close the
lid
to start centrifugation.
For more clarification refer to the RCF chart below:-
RCF CHART (FIXED)
RPM| ROUND ROTOR| PCR STRIP
| 0.2ml| 0.5ml| 1.5 ml| 2 ml| 0.2ml
3000| 319| 424| 468| 488| 467
4500| 718| 953| 1053| 1098| 1050
6000| 1276| 1695| 1872| 1952| 1868
8. ROTOR BALANCING
1. Always balance the rotor before centrifugation. The following are
symmetrical loadings of centrifuge tubes to the rotor.
2. Ensure that the samples in the tubes are of equal volume.
3. Symmetrical loading of tubes in the rotor is necessary, otherwise
vibration can
occur which can cause serious damage to the centrifuge.
4. The following are the incorrect methods of loading tubes in the centrifuge
the
rotor.
5. The following are the incorrect methods of loading tubes in the centrifuge
the
rotor.
9. INTERCHANGEABLE ROTOR
10. CHANGING THE ROTOR
This centrifuge feature magnetic rotors. Thus changing the rotors can be done
without any tool. The rotors fit on the central shaft of the motor through
magnet situated at the both
the rotors (M CT & PC R rotor). The rotor fits through snap to the central
shafts through gentle guidance.
11. OPERATION
To operate the micro centrifuge, the below steps should be followed:
1. Connect the power adaptor & Switch ‘On’ from the front side.
2. Load the rotor symmetrically to avoid accidents and damage to the centrifuge.
3. Close the lid & flip ON the front switch to start centrifugation.
4. Once the centrifugation is completed, turn the front switch to “Off” to
gradually stop the rotor.
5. After the rotor has stopped, press the lid release button and open the lid
with
your thumb in front and fingers an the top – simply lift the lid back an the
hinge.
6. If you want to stop the centrifuge quickly, push the lid release button
and the
rotor will stop within a few seconds.
In the following pages the routine centrifuge operation procedures are
explained in brief.
12. WARRANTYSTATEMENT
This product is warranted to be free from defects in material and workmanship
for a period of two (2) years from date of purchase. Your product will be duly
repaired upon prompt notification in compliance with the following conditions
:
This warranty is valid only if the product is used for its intended purpose
and
within the guidelines specified in this instruction manual. This warranty does
not
cover damage caused by accident, neglect, misuse, improper service, natural
forces or other causes not arising from defects in original material or
workmanship. This warranty does not cover any incidental or consequential
damages, commercial lass or any other damages from the use of this product.
The warranty is invalidated by any non-factory modification, which will
immediately terminate all liabilities an us for the products or damages caused
by
its use. The customer shall be responsible for the product or use of products
as
well as any supervision required for safety. If requested the products must be
returned to the distributor in well packed and insured manner and all shipping
charges must be paid.
Note: Same states do not follow limitation on the length of implied warranties
or
the exclusion or limitation of incidental or consequential damages. This
warranty
gives you specific legal rights. This warranty is given expressly in /ieu of
all other
warranties, expressed or implied.
The purchaser agrees that there is no warranty of merchantability or of
fitness for
any intended purpose and that there are no other remedies or warranties,
expressed or implied, which extend beyond the description an the face of the
agreement. This warranty is only applicable to the original purchaser.
Products received without proper authorization will not be processed for
warranty or service. All items returned for service should be sent with
postage
prepaid in the original packaging or other suitable packaging, padded to avoid
damage. We will not be responsible for damage incurred by improper
packaging.
Note: This warranty is valid only if the warranty is registered with the
supplier
within 30 days from the date of purchase.
For your reference, make a note of the serial number, date of purchase and supplier here.
Serial No. Purchase Date
Supplier
13. PRODUCT DISPOSAL
In case the product is to be disposed of, the relevant legal regulations are
to be
observed.
Information an the disposal of electrical and electronic devices in the
European
Community
The disposal of electrical devices is regulated within the European Community
by national regulations based an EU Directive 2012/19/EU an waste electrical
and electronic equipment (WEEE). According to these regulations, any devices
supplied after 13.06.05 in the business to business sphere, to which this
product
is assigned, may no longer be disposed off in municipal or domestic waste.
They
are marked with the following symbol to indicate this.
As disposal regulations within the EU may vary from country to country, please
contact your supplier if necessary.
Neuation Technologies Pvt. Ltd.
Plot No. 15, GIDC Electronic Park SEZ Kolavada Raad, Gandhinagar – 382026,
Gujarat, lndia
Website: www.neuation.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>