General Technical Specifications

RF Analyzer

RF Analyzer

RF Analyzer – Signal Trigger

RF Analyzer – Signal Trigger

1 Excludes image rejection

RF Generator

RF Generator A

RF Generator B

RF Generator C

Port Isolation

Port Isolation

Timebase

Timebase

Wireless LAN 802.11a/b/g/n/p/j/ah/af, 802.11ac (Wi-Fi 5), 802.11ax1 (Wi-

Fi 6) Measurement Specifications

Wireless LAN B

Wireless LAN A

1 802.11ax IEEE draft 1.2 support with firmware v1.7 or higher

2 Based on calibration ver 1.2.11, FW ver 1.9.1 or higher

Wireless LAN C

Wireless LAN D

802.11ax (Wi-Fi 6) Waveform Generation

Wi-Fi 6

MIMO System Performance

The additional specifications in the table below apply to the complete IQxel- M16W MIMO system.

MIMO

Bluetooth® (1.0, 2.0, 2.1, 3.0) Measurement Specifications

Bluetooth 1-3

Bluetooth 1-3 A

1 IQxel-M16W supports testing sensitivity with Dirty Packets

Bluetooth 4-4.2

1 NOC and EOC tests are the same except for the operating conditions which do not impact the test equipment requirements

2 External signal source required for these measurements (not LitePoint supplied)

3 IQxel-M16W provides the wanted signal only. No interfering signal is available

Bluetooth 5 Measurement Specifications

Bluetooth 5 introduced a couple of new test requirements:

Data Rate: New requirements for testing with 2 Mbps, 1 Mbps, 500 kbps, 125 kbps signal

Stable Modulation: Optional requirement for device to support smaller variation in the frequency deviation during modulation (modulation index between 0.495-0.505). This enhancement gives device stable and better range coverage and thus competitive advantage

IQxel-MW is capable of testing for these new requirements

Bluetooth 5

ZigBee (802.15.4), Z-wave (ITU-T G.9959), Wi-SUN (MR-FSK IEEE 802.15.4g)

ZigBee

DECT (ETSI EN 300 176-1)

DECT

Navigation

1 Navigation is a standard feature included with general purpose RF function

2 Require external attenuation for the power levels below -95 dBm

Port Descriptions

Front Panel

Front Panel

Front Panel Description

Rear Panel

Rear Panel

General I/O

General IO

General and Environmental

General and Environmental

1 Specifications valid over temperature range after invoking temperature compensation function.

For highest accuracy, recommend to enable temperature compensation if ambient temperature changes by more than 2°C.

Order Codes

Order Codes

IQxel-M16W Multi-DUT Connectivity Test System Specifications Manual – Optimized PDF
IQxel-M16W Multi-DUT Connectivity Test System Specifications Manual – Original PDF

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals