Posey 2631 Soft Limb Holder User Guide
- September 13, 2024
- Posey
Table of Contents
Posey 2631 Soft Limb Holder
DESCRIPTION OF PRODUCT:
Padded limb holder. For bed and stretcher use only.
INTENDED USE
- To protect patients assessed to be at risk of disrupting life-saving treatments (e.g., chronic tube pulling) or in danger of injury to themselves or to others by limiting limb movement in a bed or stretcher.
- Follow your hospital’s restraint policies and procedures that are compliant with USA CMS guidelines and state laws, or other governing agencies outside the USA.
CONTRAINDICATIONS:
- None.
TO PREPARE LIMB HOLDERS:
- Feed the strap at the narrow end of the triangular cuff through the horizontal slot in the wide end of the cuff. Continue threading the strap through the loop located on the outside of the device (Fig. 1).
- Thread the strap from the wide end of the cuff through the loop in the opposite direction (Fig. 2).
APPLICATION INSTRUCTIONS
The order of applying/ removing the cuff to the patient and the straps to the bed is to be determined by the clinician. Use method a. or b. below to attach straps to frame (repeat steps 1–3 on each side). Posey quick-release tie instructions on reverse side
- Triangulation process to restrict patient’s range of motion: Separate the straps and attach at different points along the frame that moves with the patient (Fig. 3), out of the patient’s reach, using quick-release ties (do not attach to side rail or head/footboard) (Fig. 4).
- To increase patient’s range of motion: Place the straps together and attach to a single point along a part of the frame that moves with the patient, out of the patient’s reach, using quick-release ties (do not attach to side rail or head/footboard) (Fig. 4).
- Bring the ends of the strap down through the inside of the side rails so they do not interfere when the side rails are raised. Make sure that the straps are attached to the frame that moves with the patient (do not attach to side rail or head/footboard) (Fig. 3), out of the patient’s reach.
- Thread the end of the strap over the top, and around the frame, at least once, and attach with a quick-release tie.
APPLYING THE CUFFS: (Repeat steps 1–3 for each side)
- Position the patient’s wrist/ankle into the prepared limb holder. Secure the hook-and-loop fastener.
- Pull the strap on the narrow end of the triangle until snug (Fig. 5). Secure the hook-and-loop fastener.
- Slide ONE finger (flat) between the cuff and the inside of the patient’s wrist/ankle to ensure proper fit. The strap must be snug, but not restrict circulation (Fig. 6).
ADJUSTING STRAP LENGTH:
Adjust the connecting strap(s) length from the frame to allow desired freedom
of movement without compromising patient or caregiver safety (Fig. 7). Ensure
the remaining strap end(s) are secured and out of the patient’s reach.
TO REMOVE:
Release the cuff from the patient. Release the anchor strap(s) from the bed
frame.
POSEY LIMB HOLDER
Cotton Flannel Hook & Loop (double strap with tie end)
TO LIMIT LOWER LIMB RANGE OF MOTION FOR LEGS (Fig. 8):
The clinician applying the strap’s criss-cross application method can
determine which is applied first (cuff or strap) and which end of the
restraint is criss-crossed.
- Attach the cuff secured to the bottom right side of the frame that moves with the patient, out of the patient’s reach, to the left ankle.
- Criss-cross the straps and attach the cuff secured to the bottom left side of the frame that moves with the patient, out of the patient’s reach, to the right ankle.
- Adjust connecting straps as necessary.
PRECAUTIONS:
-
A clinical assessment and decision are required when used with monitoring lines or if the patient has a wound or dislocated/fractured limb.
-
Check the patient regularly to ensure that circulation is not impaired. Serious injury may occur if the cuff restricts circulation when the limb holder is applied.
WARNING : Additional or different body or limb restraints may be needed (visit tidiproducts.com) -
Some patients may require additional interventions in conjunction with a restraint in order to prevent injury to self or others:
- If the patient pulls violently against the bed straps.
- To reduce the risk of the patient getting access to the line/wound/tube site.
- To prevent the patient from flailing or bucking up and down, causing self-injury.
-
It is a clinical decision to decide when a restraint is no longer deemed safe
BED SAFETY : Refer to the Food and Drug Administration (FDA), or other governing agencies outside the USA, for the most recent Hospital Bed Safety Guidelines and the bed manufacturer’s instructions for use
For RX PRODUCTS ONLY. Federal law (USA) restricts RX devices to sale by or on order of a physician. For use in a licensed healthcare facility only.
STAFF TRAINING:
TIDI offers in-service training aids at no charge. Contact TIDI online at
www.tidiproducts.com or call toll-free at 1.800.521.1314.
BEFORE APPLYING ANY RESTRAINT:
Follow your hospital’s restraint policies and procedures that are compliant
with USA CMS guidelines and state laws or other governing agencies outside the
USA.
ADDITIONAL WARNINGS:
- ALWAYS monitor patient per facility policy. Improper application or use of any restraint may result in serious injury or death. Be aware that constant monitoring may be required for:
- Aggressive or agitated patients; and
- Patients in a supine position; ensure that being in this position would not cause any complications for those who are at risk of vomiting while being restrained.
- NEVER alter or repair this product. ALWAYS Inspect before each use: Check for broken stitches or parts; torn, cut or frayed material; or locks, buckles, or hook-and-loop fasteners that do not hold securely. DO NOT use soiled or damaged products. Doing so may result in serious injury or death. Dispose of damaged products per facility policy for BIOHAZARDOUS material.
- ALWAYS secure straps to a part of the frame that moves with the patient (not foot/head board or siderails), out of the patients reach, using quick-release ties (see drawing below) or buckles. These allow easy release in the event of an accident or fire. Test to make sure straps cannot tighten, loosen, or slip and create excess slack. If this occurs, the patient may slide off the chair or bed, increasing the risk of serious injury or suffocation. Restraint release is an important part of facility fire and disaster drills. Straps can be cut with scissors in an emergency.
- NEVER secure restraint strap to side rail or head/foot board.
- NEVER use Posey products on toilets, or on any chair or furniture that does not allow proper application as directed in the Application Instructions. DO NOT use at home.
- NEVER expose this product to open flame, fire, smoking materials, or high heat sources. Some products may melt or ignite and burn. The facility smoking/no smoking policy should be strictly enforced.
- NEVER use a Posey product as a seat belt in a moving vehicle. Posey products are not designed to withstand the force of a crash or sudden stop.
- Test Zippers or hook-and-loop fasteners before each use. DISCARD device if it does not fasten securely.
LAUNDERING INSTRUCTIONS (if applicable):
- Fasten all buckles and locks to reduce risk of damage during wash and dry cycles. DO NOT put buckles or locks through extractors. For maximum life, launder in a laundry bag.
- Stainless Steel Locks: Posey recommends that locks be treated with a dryfilm lubricant (silicone) after each cleaning. For best results, spray a small amount into the lock. Work the action of the lock with a key several times to ensure that all the surfaces are well lubricated.
- Before laundering, zip up and turn the product inside out to protect zipper.
- Hook-and-loop fasteners may collect lint after repeated use or laundering, reducing grip strength. Fasten the “hook” to the “loop” before laundering to help prevent lint buildup. As needed, use a stiff-bristle brush to remove lint from the “hook” side.
- These products, other than foam products, can be machine washed under CDC guidelines for material soiled with blood or bodily fluid.
- For non-contaminated material, use lower temperature wash and dry cycles to extend product life.
- For foam products
- Make sure products are completely dry before use.
STORAGE AND HANDLING
- This device is designed for use in normal indoor environments.
- This device may be stored in ambient warehouse temperatures at normal humidity levels. Avoid excess moisture or high humidity that may damage product materials
HOW TO TIE THE POSEY QUICK-RELEASE TIE
- Wrap strap once around the frame that moves with the patient (do not attach to side rail or head/footboard), leaving at least an 8” (20 cm) tail. Fold the loose end in half to create a loop and cross it over the other end.
- Insert the folded strap where the straps cross over each other, as if tying a shoelace. Pull on the loop to tighten.
- Fold the loose end in half to create a second loop.
- Insert the second loop into the first loop.
- Pull on the loop to tighten. Test to make sure strap is secure and will not slide in any direction.
- Repeat on other side. Practice quick-release ties to ensure the knot releases with one pull on the loose end of the strap.
Report any serious incident related to device use to TIDI Products and the Member State Competent Authority. | Translations of this document in French, Spanish, Dutch, German, Italian, and Portuguese are located at www.tidiproducts.com/IFU.
DISPOSAL :
Dispose of product according to local or facility guidelines if product is
worn or damaged.
TIDI Products, LLC
570 Enterprise Drive, Neenah, WI 54956 USA
Phone: 1.800.521.1314
International: +1.920.751.4036
www.tidiproducts.com
MDSS GmbH Schiffgraben 41 30175 Hannover, Germany
UK Responsible Person Emergo Consulting (UK) Limited c/o Cr360 – UL
International Compass House, Vision Park Histon Cambridge CB249BZ United
Kingdom
© 2023 TIDI Products, LLC. All rights reserved. Posey is a registered
trademark of TIDI Products, LLC.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>