Milesight VS125 AI Stereo Vision People Counter User Guide
- September 11, 2024
- Milesight
Table of Contents
Milesight VS125 AI Stereo Vision People Counter
Product Specifications
- Model: VS125
- Components: VS125 Device, Ceiling Mounting Kits, Multi-interface Cable
- Accessories (Optional): Quick Start Guide, Warranty Card
- Cellular Version Accessories: PoE Version Ethernet Port(PoE), DC Power Interface, Nano SIM Card Slot
- Power Source: DC Power Adapter (12V, 2A) or PoE Switch (802.3af standard)
- Mounting: Ceiling/Lintel Mount with Optional VB01 Multifunctional Bracket
Product Usage Instructions
Turning On/Off Wi-Fi
- To turn on Wi-Fi: Press and hold the power button until the blue light is on.
- To turn off Wi-Fi: Press and hold the power button until the green light is on.
Resetting to Factory Default
To reset to factory default: Press and hold the power button for more than
10 seconds. The green light will blink until the reset process is completed.
Ceiling Mount Installation
- Step 1: Ensure ceiling thickness is greater than 30mm. Remove blocking rubber if wires need to be protruded.
- Step 2: If hiding power cord into the ceiling, drill another wire hole.
- Step 3: Connect Multi-interface if alarm I/O is to be used.
- Step 4: Mount the device on the ceiling/lintel.
- Step 5: For more accurate detection, tilt the device slightly within 10 degrees.
FAQ (Frequently Asked Questions)
-
Q: Where can I download software and files for the VS125?
A: All software & files can be downloaded from Milesight Download Center. -
Q: What are the FCC Rules compliance conditions for the VS125?
A: The device must not cause harmful interference and must accept any interference received. Users should follow FCC
guidelines for proper operation. -
Q: What is the recommended distance between the radiator and the body when operating the VS125?
A: The device should be operated with a minimum distance of 20cm between the radiator and the body to comply with FCC radiation exposure limits.
AI STEREO VISION PEOPLE COUNTER
Packing List
Cellular Version Only Accessories
PoE Version Only Accessories
Hardware Overview
PoE Version:
Hardware Overview
SIM Card Installation (Cellular Version Only)
Power Supply
- Powered by DC Power Adapter (12V, 2A)
- Powered by PoE Switch (PoE version only, 802.3af standard)
- Note: Ensure the length of the Ethernet Cable crystal head is less than 40mm.
Installation
Ceiling Mount
Installation Conditions: ceiling thickness > 30mm
Step1:
Note: Remove the blocking rubber if the wires need to be protruded from the side of the device
Step2:
Note: If you need to hide the power cord into the ceiling, drill another wire hole.
Step3:
Note: if the alarm I/O is going to be used, please connect the Multi-interface to the device
Step4:
All software & files can be downloaded from
https://www.milesight.com/iot/resources/download-center/#documents
Milesight IoT Co., Ltd.
www.milesight.com
Step5:
Ceiling/Lintel Mount (with Optional VB01 Multifunctional Bracket)
Ceiling Mount
Lintel Mount
Installation Note:
- Make sure there are no obstacles within the live view of device.
- When the device is installed on the door frame or door, it is recommended to use VB01 or other bracket to make the device is above 30cm from the door with enough time to capture the target.
- When the device is installed at the door of the fan switch, the equipment needs to be installed on the opposite side of the door
- Make sure there are no obstacles within the live view of device.
- When the device is installed on the door frame or door, it is recommended to use VB01 or other bracket to make the device is above 30cm from the door with enough time to capture the target.
- When the device is installed at the door of the fan switch, the equipment needs to be installed on the opposite side of the door
When using Multi-device stitching, devices should be installed next to each other and ensure the detection areas are tangent or overlapping
Access the Web GUI
- VS125 provides user-friendly web GUI for configuration access via Wi-Fi or Ethernet port.
- Users need to customize the password when using the device for the first time. The default settings are as below:
- Wi-Fi SSID: People Counter_xxxxxx (can be found on the device label)
- Wi-Fi IP: 192.168.1.1
- Ethernet IP: 192.168.5.220 (PoE Version Only)
- Here are 2 ways of accessing the web GUI:
- Wireless Method: Enable the Wireless Network Connection on your computer, search for corresponding Wi-Fi SSID to connect it, then type 192.168.1.1 to access the web GUI.
- Wired Method: Connect the device to computer via Ethernet port, assign the IP address of computer to 192.168.5.xxx manually, then type 192.168.5.220 to access the web GUI.
FCC Statement
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and.
- This device must accept any interference received, including interference that may cause undesired operation
Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator& your body. This transmitter must
not be co-located or operating in conjunction with any other antenna or
transmitter.