ESL VISION ESL-ISS-MSEN-01 IntelliSense Panel Sensors Owner’s Manual
- September 7, 2024
- ESL VISION
Table of Contents
- ESL-ISS-MSEN-01 IntelliSense Panel Sensors
- Product Specifications:
- Installation Instructions:
- Remote Programming Instructions:
- Memory Mode (Commissioning):
- Continuous Adjustment or Daylight Harvesting Mode:
- Q: How do I reset the sensor to default settings?
- Q: What is the standby time for the sensor?
ESL-ISS-MSEN-01 IntelliSense Panel Sensors
“`html
Product Specifications:
- Output Voltage: 10 VDC
- Output Current: 10mA Max
- Output Power: 0.1W
- Compliance: UL8750
- Warranty: 5 Years
Installation Instructions:
- Remove the sensor plate from the fixture’s rim.
- Remove the flat cable from the back of the plate.
- Insert the cable terminals into the approved sensor.
- Snap the sensor into the fixture securely.
Remote Programming Instructions:
Memory Mode (Commissioning):
Set settings to a program profile A to F and send settings to
sensor.
Continuous Adjustment or Daylight Harvesting Mode:
-
Trim-High=100%, Sensitivity=low, T1=30min, Standby Dim=50%,
T2=15min, Photocell=CAL -
Trim-High=100%, Sensitivity=low, T1=30min, Standby Dim=50%,
T2=15min, Photocell=OFF -
Trim-Low=50%, Sensitivity=low, T1=30min, Standby Dim=50%,
T2=30min, Photocell=CAL -
Manual Mode, Trim-High=100%
-
Daylight Harvesting, Trim-Low=50%, Sensitivity=low,
T1=15min
FAQ:
Q: How do I reset the sensor to default settings?
A: To reset to default settings, follow the RESET MODE
instructions provided in the manual.
Q: What is the standby time for the sensor?
A: The sensor has a standby time of 5 minutes with no motion,
and the fixture dims to 30%. After 60 minutes with no motion, the
fixture turns off.
“`
INTELLISENSETM PANEL SENSORS
SoloSenseTM PIR Occupancy & Daylight Harvesting ESL-ISS-SSEN-01
Overview:
The ESL Vision ESL-ISS-SSEN-01 is a standalone PIR occupancy and daylight
harvesting sensor designed for quick installation into our IntelliSenseTM
quick connect lighting fixtures. With this sensor installed, the fixture
becomes remote programmable, allowing for single fixture control.
Project: Catalog #: Notes:
Key Features & Benefits:
· PIR Occupancy Sensing · Daylight Harvesting · High & Low Trim Capable ·
Single Fixture Control · Simple Remote Programming · Simple Lighting Control
Product Specifications:
INPUT Input Voltage: 12 VDC Input Current: 9mA Max Input Power: 0.1W Dimming:
Class 2, 010 VDC, 10mA Max Sinking Current: 10mA Max
OUTPUT Output Voltage: 10 VDC Output Current: 10mA Max Output Power: 0.1W
ENVIRONMENT Housing Material: UL 94-5VA Plastic Location of Use: Indoor
Detection Range: 32 Feet Max Mounting Height: 15 Feet Max Operating
Temperature: -22°F to 149°F (-30°C to 65°C) Storage Temperature: -22°F to
185°F (-30°C to 85°C) IP Rating: IP20
CERTIFICATIONS Compliance: UL8750 Warranty: 5 Years
Ordering Guide:
ESL ESL
–
FAMILY
–
TYPE
–
ISS
–
SSEN
(ISS) IntelliSenseTM Series
(SSEN) SoloSenseTM
–
MODEL
–
01
(01) Highbay Sensor
Catalog Data:
ITEM # ESL-ISS-MSEN-01 ESL-ISS-SSEN-01
DESCRIPTION MultiSenseTM Plug and Play 3 Wire networked PIR occupancy and daylight harvesting sensor SoloSenseTM Plug and Play 3 Wire PIR occupancy and daylight harvesting sensor
Date:
Page 1 of 3
Not All Part Numbers DLC Qualified. For a Complete Listing Please Consult the DLC Qualified Products List (QPL).
Copyright © 2024 ESL Vision, LLC. All rights reserved. Rev: 08/01/24
INTELLISENSETM PANEL SENSORS
SoloSenseTM PIR Occupancy & Daylight Harvesting ESL-ISS-SSEN-01
Installation:
Page 2 of 3
Fig. 1
1Remove the sensor plate from fixtures rim.
Coverage:
0′
5′
10′
Fig. 2
2Remove the flat cable from the back of the plate.
16′ 8′ 0′ 8′
Fig. 3
3Insert the cable terminals into the approved sensor.
32 ft
15′ 16′
8′
0′
8′
16′
Side View Coverage
Wiring Diagram:
LIVE (Black)
Neutral (White)
LED Driver
LOAD
Dim+ (Purple/22AWG) 12V+ (Yellow/22AWG) Dim-/12V- (Pink/22AWG)
16′
16′
8′
0′
8′
16′
Top View Coverage
Reset LED
Fig. 4
4Snap the sensor into the fixture securely.
Dimensions:
IntelliSenseTM Panel Sensors ESL-ISS-MSEN-01 & ESL-ISS-SSEN-01
0.98″
2.44″
0.82″ 0.51″
Not All Part Numbers DLC Qualified. For a Complete Listing Please Consult the DLC Qualified Products List (QPL).
Copyright © 2024 ESL Vision, LLC. All rights reserved. Rev: 08/01/24
INTELLISENSETM PANEL SENSORS
SoloSenseTM PIR Occupancy & Daylight Harvesting ESL-ISS-SSEN-01
Page 3 of 3
Remote Programming Instructions: Memory Mode (Commissioning)
1. Select either A, B, C, or D. 2. Indicator lights on the remote will flash
to indicate the current saved settings. 3. Settings can be configured by
pressing appropriate buttons in the highlighted gray section of the remote
buttons. (TRIM-LEVEL, SENSITIVITY, HOLD TIME, STANDBY DIM, STANDBY TIME, and
PHOTOCELL). Review selected settings and make changes as necessary. 4. Point
IR remote to desired luminaire for configuration and press “SEND”. 5. If
configuration is successful, luminaire will flash twice to confirm settings
are saved. Any parameter change to the current saved settings on A to F will
override previous settings and will be automatically saved on the remote. If
configuring multiple luminaires, select the configured memory mode A to E then
follow steps 4 and 5. E Mode allows visual adjustment to choose the desired
dimming level.
Remote Programming Instructions: Continuous Adjustment or Daylight Harvesting
Mode
1. Point IR remote to desired luminaire. 2. Press “ON” then press DIM+ or
DIM- to adjust dimming level. 3. Press “F”, indicator lights on the remote
will indicate current saved settings. Note: only TRIM-LEVEL, SENSITIVITY, and
HOLD TIME can be selected for Daylight Harvesting settings. 4. Review selected
settings and make changes as necessary. Press “SEND”. 5. If configuration is
successful, luminaire will flash twice to confirm setting saved. If
configuring multiple luminaires, select the configured DAYLIGHT HARVESTING
settings then follow steps 4 and 5.
RESET MODE
Motion: 100% No Motion: 5 minutes and fixture dims to 30% No Motion: 60
minutes and fixture turns off
BUTTON OPERATION ON OFF TEST RESET DIM +/TRIM LEVEL SENSITIVITY HOLD TIME F MODE DAYLIGHT HARVESTING STANDBY DIM
Turns on luminaire
Turns off luminaire
Test mode will last 5 mins then return to previous setting, test mode will
hold 2 seconds SDL 50% and standbytime for 2 seconds TrimHigh=100%,
Sensitivity=High, T1=5 min, Standby Dim=30%, T2=60min, Photocell=OFF Remote
will manually dim luminaire up or down by increments of 0.5V. Must be smooth
dimming if holding dimming button.
Set Maximum threshold values of 50%75%100%
Off (PIR OFF enter Photocell ON/OFF function)/ LOW (50%) or HIGH (100%)
30sec5min15min30min (time of no occupancy after which fixture goes to
standby) (Enable/Disable) Measure and set feature to allow the fixture to
maintain a light level, if turned on. Select any standby dim level:
0%10%30%50%
STANDBY TIME PHOTOCELL MODE SEND DEFAULT MODE A DEFAULT MODE B DEFAULT MODE C DEFAULT MODE D DEFAULT MODE E DEFAULT MODE F
Standby time 10sec5min15min30min1hr, “” means the fixture is effectively
controlled by the daylight sensor LOW (1fc)HIGH (50fc)CAL Collecting the
current Lux Level OFF
Set settings to a program profile A to F
Send settings to sensor
Trim-High=100%, Sensitivity=low, T1=30min, Standby Dim=50%, T2=00,
Photocell=CAL
Trim-High=100%, Sensitivity=low, T1=30min, Standby Dim=50%, T2=15min,
Photocell=CAL Trim-High=100%, Sensitivity=low, T1=30min, Standby Dim=50%,
T2=15min, Photocell=OFF Tri m-Low=50%, Sensitivity= low, T1 =30min, Stand by
Dim =50%, T2=30min, Photocell=CAL
Manual Mode, Trim-High=100%
Daylight Harvesting, Trim-Low=50%, Sensitivity=low, T1=15min
Not All Part Numbers DLC Qualified. For a Complete Listing Please Consult the DLC Qualified Products List (QPL).
Copyright © 2024 ESL Vision, LLC. All rights reserved. Rev: 08/01/24