| 2 % 2 m max
---|---
2 % 200 kg max
A- SAFETY INSTRUCTIONS
WARNING: Important safety instructions. It is essential to follow these
instructions for reasons of & wrsonal safety. Keep these instructions in a
safe place.
WARNING: Important safety instructions. Follow all instructions carefully
as improper installation may resultin serious injury.
This product is only designed for the automation of a swing gate for
«residential» use.
The power supply installation must comply with current standards in the
country where the product is installed (NF C 15-100 for France) and be carried
out by qualified staff. A means of disconnecting all the poles of the supply
network must be provided. This device must be connected directly to the supply
terminals and have a contact separation distance on all poles to ensure
complete disconnection in accordance with the installation rules. The mains
supply must be protected against overload by a suitable trip switch and an
earth leakage circuit breaker.
CAUTION: The motorised system must be disconnected from its power source
during installation, cleaning, maintenance and parts replacement.
Installation requires qualified staff with mechanical and electrical skills.
-
Make sure that the temperature range indicated on the motorised device is suitable for the installation’s location.
-
Only original parts should be used to replace or repair the motorised system.
-
Before installing the motorised device, check that the driven part is in good mechanical condition, properly balanced and opens and closes correctly.
-
The motorised device cannot be used with a driven part incorporating a side gate.
-
Ensure that crushing caused by the opening movement of the driven part is avoided between the driven part and the surrounding fixed parts.
-
After installation, ensure that the mechanism is properly adjusted and that the protection system and any manual disconnection devices function properly.
-
Activation of the manual disconnection device may cause uncontrolled movement of the driven part due to mechanical failure or loss of balance.
-
Frequently examine the installation for imbalance where applicable and signs of wear or damage to cables, springs and mounting. Do not use if repair or adjustment is necessary.
-
This appliance may be used by children at least 8 years old and by people with reduced physical, sensory or mental capabilities or without experience or knowledge, if they are properly supervised or instructed in the safe use of the appliance, and if the risks involved have been understood. Children should not play with the appliance.
The user’s cleaning and maintenance must not be carried out by unsupervised children. -
Do not allow children to play with the unit or its controls, including remote controls.
-
Permanently attach the label for the manual disconnection device to the operating element of this device.
Only use the remote control when you have a complete view of the gate.
If in any doubt, do not operate the system, as it could be damaged.
SCS SENTINEL certifies that its swing gate operators for residential use comply with the European standards and safety regulations for swing gate operators (EN 60335-2-103). The use of this product outside the specified conditions or the use of components or accessories not recommended by SCS SENTINEL may compromise the safetyn! Prupen and persons, and is therefore prohibited. SCS SENTINEL accepts no liability for any damage resulting from failure to comply with the instructions provided in this manual.
Potential risks
There are 4 potential risks 3 zones identified opposite: Risk 1: Shock and crushing
Prevention :
- Obstacle detection by motor.
- Use of photocells.
Risk 2 : Hand crushing
Prevention : 1
- Leave a minimum distance of 10 cm between the leaf and the pillar/wall.
- Notch the corner without pillar weakening it.
Risk 3 : Imprisonment and crushing
Prevention :
- Obstacle detection by the motor.
- Leave a minimum distance of 50 cm between the motor arm and the wall (or other fixed part).
Risk 4 : Crushing of the feet
Prevention :
- To avoid a danger zone for feet, leave a minimum distance of 12 cm or a maximum of 5 mm between the bottom of the leaves and the floor.
B- DESCRIPTION
B1- Content
B2- Dimensions
C- WIRING / INSTALLING
C1- Standard installation
C2- Dimension chart
Comply with the measures shown on the chart for proper installation. Adjust
the gate structure to fit it for best automation, if necessary.
Before proceeding with the installation, be sure that gate moves freely and
that:
- Hinges are properly positioned and greased.
- No obstacles in the moving area.
- No frictions between two gate leafs or with the ground while moving
inside opening – installation with closed gate
Outside opening – installing with open gate (max 90°)
Warning ! With outside opening,it is imperative to install a blinker on
pillar for security reasons.
For an external opening, it will be necessary to manufacture a metal part in
order to offset the motors, it is then IMPERATIVE to respect the
dimensions of installation indicated in the table.
C3- Emergency release
In case of power failure or to program your automatic gate, you can manually
unlock the engines:
Under the gate. Insert the hex wrench for unlocking and then turn anti-
clockwise 180 degrees. You can now open the gate by hand.
To lock again the engine, insert the hex wrench for locking and then turn
clockwise 180 degrees. Permanently attach the label for
the manual disconnection device to the operating element of this device.
C4- Motor fixing
Before placing the arm on the gate, unlock the arm (C3) and take out the tub
from the cylinder.
Then, retract the tube by 3 cm (this ensures that the gate is locked when
closed).
Tip
If you have problems unlocking your motor, you can use a battery.
Simply connect the white and yellow motor wires, one way or the other
following the polarity to operate the motors.
- Fix the first bracket to the pillar. Position the automation in the bracket, then place the screw and nut.
- Assemble the second bracket with the other side of the automation and screw the bracket to the closed gate.Make sure arms are fixed in horizontal position especially in those positions:
- Gate in « CLOSE » position 2) Gate in « OPEN » position 3) Gate at « 45°
angle » position
Prior to weld the bracket on the gate leaf (if necessary), cover the gate opener to prevent damages from sparks.
C5 Wiring diagram
C6- Installing
Prepare allthe wires of the accessories beforehand and connectthe wires to the gear motors and accessories on the PCB as shown in Figure 1. All of the wiring connections of the accessories are not requested to distinguish the positive (+) and the negative (-) polarity.
Control box
BEFORE INSTALLATION
Decide the installation position of control box first, it is suggested to be
installed near the gate and should be protected from possible damage.
Be aware of the motor cable length before deciding the installation position
of the control box.
PRE-INSTALLATION
- Remove the cover by unscrewing the four screws on the cover. See Figure 1(1).
- Use a screwdriver to puncture the holes beneath the bottom of the control box. See Figure 1(2).
- Fix and secure your electronic box on the wall.
- Connect the wires of the various devices to be connected to the PCB board (devices described on the following pages)
- Seal the holes of cables entries
- Close the box by tightening the 4 screws. (See Figure 1(3))
Motor
MOTOR – WIRE CONNECTION
Avoid tension in the cable during
open and close phase.
For gates opened outward:
M1 Motor : Connect the motor wire (Yellow -) to the terminals Mo1 + and (White
+) to the terminals Mo1-. (motor opening in first)
M2 Motor : Connect the motor wire (Yellow -) to the terminals Mo2 + and (White
+) to the terminals Mo2 -.
M1 MOTOR CONNECTION (first opening motor)
M2 MOTOR CONNECTION
(second opening motor) Electric Lock
(option)
Connect the two wires from the electric lock (24V) to the terminal Lo + and
Lo- on the PCB.
Wiring to 230V power supply
Photocells
The photocells are safety devices for control automatic gates. Consist of one
transmitter and one receiver based in waterproof covers; it is triggered while
breaking the path of the beams. If an obstacle is detected, the gate stops and
opens again slightly allowing the obstacle to be released safely. Blinker
Remove any packaging before connecting.
D- SETTING/USING
D1- Single/double gate setting (dip switch 1) Switch settings: «on right
position, «offy left position.
DIP SWITCH 1 D/S set:
ON = double gate operation
OFF = single gate operation (connection on 11 and 12)
D2- Power setting (dip switch 2 et 3)
DIP SWITCH (OVER C1) | DIP SWITCH (OVER C2) | CURRENT (AMP) |
---|---|---|
DIP switch 2 OFF | Dip switch 3 OFF | 5A |
DIP switch 2 OFF | Dip switch 3 ON | 4A |
DIP switch 2 ON | Dip switch 3 OFF | 3A |
DIP switch 2 ON | Dip switch 3 ON | 2A |
D3- Gate auto-close adjustment (dip switch 4)
DIP SWITCH 4
«ON »: Active automatic closing in 30 seconds. Simultaneously pressing the two
remotes top keys (opened or closed gate) will turn OFF the automatic mode (the
blinker will flash 3 times as confirmation).
Repeat the operation to turn ON the automatic mode (the blinker willflash 3
times as confirmation).
Note in case of automatic closing, photocells are required.
«OFF » : Automatic closing OFF (caution it will still be possible to turn ON
with the remote)
D4- Photocell adjustment (dip switch 5)
DIP SWITCHS:
ON : Photocells ON. When the photocells detect an obstacle while the gate is
closing, the gate stops and opens during 2 seconds.
If the gate auto-close is adjusted, and the photocells detect an obstacle when
the gate is totally opened, then the closing time will be reseted.
OFF : No detection by the photocells, the photocells will not control the
opening of the gate.
D5- Dephasing of the leaves (dip switch 6)
DIP SWITCH 6:
ON:: Dephasing in closing / opening of 8 seconds.
OFF : Dephasing in closing / opening of 3 seconds.
D6- Decelaration speed
The speed is 70% output of the full speed (no adjustment possible).
D7- LED indication LED 1 RF indicator : radio frequency
LED1 will be on when remote controls are activated.
LED 2 System learning:
LED 2 blinks twice per second during normal operation and once per second
during learning. Static LED2 means incorrect programming.
LED 3 Photocells:
LED 3 will be on when photocells are not aligned.
bLED 4 will be on if the switch of the transmitter, key selector, or the push
button is activated.
D8- Remote controls learning process
Press “RF-learn” button for 2 seconds, and the LED1 will be on; then press the
transmitter top left button.
The LED1 will blink twice and stay on for 10 seconds then be off. And the
remote memorize has completed.
D9- System learning process for double leaf gate
The remote control memory storing operation must be over before starting the
final system learning process.
Let your gate totally opened then lock them (part C3)
Press «SYS-learn» (until the LED2 light begins to flash once every second,
instead of twice every second as it normally would), then press the upper-left
key for a double gate.
The system learning process will be as follows, step by step:
After step 6, the system
learning process is complete. You can use it with the remote control:
double gate full opening pedestrian opening (single gate)
The LED2 light will remain ON until the system learning process is not over.
Check the wiring connection and repeat the step.
D10- System learning process for single leaf gate
Switch 1 OFF.
Open the leaf totally.
Press «SYS-learn» (until the LED2 light begins to flash once every second,
instead of twice every second as it normally would), then press the upper-
right key for a single gate.
The system learning process will be as follows, step by step:
E- TECHNICAL FEATURE
Motor
Motor | 24V DC motor with manual release |
---|---|
Gear type | Worm gear |
Stroke length | 435mm |
Power supply | 24V DC |
Maximum gate weight / Maximum gate length | 150 kg / 1,6 m per leaf |
Operating Temperature | -20°C~+50°C |
Dimension | 710 mm x 98 mm x 192 mm |
Blinker
Antenna included | YES (coaxial cable not supplied) |
---|---|
Bulb | LED E14 24V 1W (supplied) |
Power cable | 2x 1 mm2 (not supplied) |
Bulb connection | Unpolarized at the electronic card connection. |
Screws | included |
Do not supply 230V | |
Operating temperature | -20°C~+50°C |
Dimensions | 74 x 167 x 59 mm |
Remote controls
Channels | 4 |
---|---|
Frequency – Maximum transmitted power | 433.92 MHz – power < 10mW |
Power supply | 1 battery lithium CR2032 included |
Security | rolling code technology |
Photocells
Detection Method | Infrared Beam |
---|---|
Sensing Range | MAX~10m |
Input Voltage | 12~24V AC/DC |
Response Time | <100ms |
Operation Indicator | RX: Red LED On (beam broken) / Off (beam aligned) TX : |
Red LED On
Dimensions| 63 x 63 x 30 mm
Output Method| Relay Output
F- MAINTENANCE
F1- Motor
Conduct the following operations at least every 6 months. If in high intensity
of use, shorten the period in between.
Disconnect the power supply:
- Clean and lubricate the screws, the pins, and the hinge with grease.
- Check the fastening points are properly tightened.
- Make the wire connection are in good condition.
Connect the power supply:
- Check the power adjustments.
- Check the function of the manual release.
- Check the function of photocells or other safety device.
F2- Remote control
G- TECHNICAL ASSISTANCE
G1- Troubleshooting
Problem | Solutions |
---|---|
Overheated Back-up Batteries | Check the wiring connection of the batteries. |
The gate doesn‘t move when pressing the button of the transmitter | 1. Check |
if LED1is “ON” once press the transmitter.
2. Check if the voltage of the batteries is above 25V.
3. Check if LED2 is “ON” and blinks accordingly.
4. Make sure all the wiring connections are firmly connected to the terminals
on the PCB.
5. Make sure the fuse is workable. on the panel and power socket.
The transmitting distance is too short| Make sure the connecting terminals of
the Antenna is firm.
Check the battery on the trasmitter.
The Flashing light does not work| Unscrew and screw in the bulb
Check if the wiring connection of the flashing light is correct.
The leaves suddenly stop during moving
The leaves does not move or only move toward one direction| 1. Check if the
gate can be moved freely and no obstacles in between.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the safety beam are operating properly if installed.
4. Cut off the power of the engine. Release the motor and make sure the gate
can move freely.
The master gate closes to the end first and the slave gate stops, which the
opening or closing sequence is not being operated properly| 1. Check if the
gate can be moved freely and no obstacles in between.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the fuse is workable.
4. Make sure the safety beam are operating properly if installed.
5. Cut off the power of the engine. Release the motor and make sure the gate
can move freely.
The gear motors does not run and the relay is noisy when operating the gate
opening and closing| Check the condition fuse.
No remote control connection| 1. Check LED1 is blinking when pressing the
remote control key.
2.Check RF1 receiver is ok.
3.To check that the remote control is associated when the remote control is
pressed, LED 1and LED 4 must light up.
4. If the LED flashes for 1 second when the remote control is pressed, the
battery must be changed.
5. Remove and replace the plug-in receiver
4 steps instead of 6 when teaching| Reverse polarity on all motors
https://www.youtube.com/playlist?list=PLhdc503NdLNZL_lPdBdLh34hrlYLYmiNj
G3- Online chat
Any question ?
For anindividual answer, use our online chat on our website www.scs-
sentinel.com
H- WARRANTY
SCS Sentinel grants to this product a longer warranty period, beyond the legal
time, as a sign of quality and reliability.
The ice will be required as proof of purchase date. Please keep it during the
warranty period.
Carefully keep the barcode and the proof of purchase, that will be necessary
to claim warranty.
Are never covered by our warranty:
- Damage resulting from the consequences of a bad installation (bad wiring, reverse polarity ..).
- Damage resulting from improper use of the device (use in contradiction with the manual) or its modification.
- Damage resulting from the consequences of the use of components not from SCS SENTINEL.
- Damage due to lack of maintenance, physical shock.
- Damage due to weather: hail, lightning, strong wind etc..
- Returns made without a copy of the invoice or receipt.
I- WARNINGS
Don’t throw batteries or out of order products with the household waste
(garbage). The dangerous substances that they are likely to include may harm
health or the environment. Make your retailer take back these products or use
the selective collect of garbage proposed by your city.
Do notingest battery, Chemical Burn Hazard. This product contains a button
cell battery. If the button cell battery is swallowed, it can cause severe
internal burns in just 2 hours and can lead to death. Keep new and used
batteries away from children. If the battery compartment does not close
securely, stop using the product and keep it away from children. If you think
batteries might have been swallowed or placed inside any part of the body,
seek immediate medical attention. Do not clean the remote control with
abrasive or corrosive substances. Use a simple cloth. Do not allow children to
play with the product or packaging.
When replacing the battery, use a battery with the same characteristics as the
one supplied with the product. Remove the batteries from the equipment if it
is not to be used for a prolonged period, except in emergency situations.
Batteries must not be exposed to excessive heat or thrown into a fire.
J – DECLARATION OF CONFORMITY
SCS Sentinel hereby declares that this product s in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU and Directive 2006/42/EC. The Declaration of Conformity can be found at: www .scs-sentinel.com/downloads
All the information on:
www.scs-
sentinel.comhttps://www.youtube.com/c/Scs-
laboutique
110, rue Pierre-Gilles de Gennes
49300 Cholet – France
Documents / Resources
| scs
sentinel MVE0100 Automation Kit For Swing
Gate
[pdf] User Manual
MVE0100, MVE0100 Automation Kit For Swing Gate, Automation Kit For Swing Gate,
Swing Gate, Gate
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>