Product Specifications

  • Product: Universal Overflow Regulator
  • Product Code: 8520-OF
  • Gas Type: LPG
  • Capacity: 1.5kg/h
  • Overflow limiter: Yes
  • Leak and level indicator: Yes
  • Inlet Pressure: 1~16 bar
  • Operating Pressure: 50 mbar

FAQ

  • Where can I find warranty information?
    • You can contact Dometic Mobile Cooking Netherlands B.V. or Dometic Mobile Cooking UK Ltd. for warranty details or visit your local dealer’s website at www.cadacinternational.com/support.

Symbol

Explanation of Symbols

  • Recycling packaging material. Place the packaging material in the appropriate recycling waste bins wherever possible.

CAUTION

  • Ensure adequate ventilation. Use this device only outdoors.

IMPORTANT

  • Read these instructions carefully to become familiar with the device before connecting it to the gas cylinder.
  • Keep these instructions for future reference.

Safety instructions

  • This household regulator is designed to supply gas to gas-consuming appliances at the pressure and capacity indicated on the identification label.
  • It can be mounted on any cylinder equipped with a cylinder valve with a manually operated closure.
  • This regulator is equipped with a manual flow limiter.
  • The following mounting, operation, and usage instructions must be followed.
  • Check that the gasket on the cylinder valve is in place and in good condition.
  • Before mounting the regulator, ensure that the rubber gasket in the bottle valve or in the pressure regulator is in good condition.
  • If the gasket or the gas valve is not in good condition, ask your gas supplier to replace it with another gasket.
  • Ensure that the gas hose is in good condition and not older than 5 years.
  • When installing the regulator, ensure that the cylinder valve and gas appliances are turned off.
  • Under normal usage conditions, to ensure safe operation of the installation, it is necessary to replace the regulator every 10 years from the production date.
  • For outdoor use. The device should be placed or protected against direct exposure to water and rain.
  • Use gas cylinders in an upright position only.
  • Never remove the regulator in the Gas ON position.
  • Do not move the cylinder while it is in use.
  • Do not fit or exchange gas cylinders in the presence of an open flame.
  • Do not use tools to mount the pressure regulator on the gas bottle. Hand-tightening the nut is sufficient.
Gas type LPG
Capacity 1.5kg/h
Overflow limiter Yes
Leak and level indicator Yes
Inlet pressure (bar) 1~16
Operating pressure 50 mbar

Installation Instructions

Installation steps:

  • Perform a visual inspection of the regulator. Remove dirt or loose metal shavings.
  • Connect the hose to the outlet nozzle (fig 1) of the regulator (apply water to the hose to facilitate easier insertion).
  • Remove the seal or cap from the gas cylinder valve. Ensure there is no open combustion or flame in the immediate vicinity.
  • Hand-tighten the regulator nut onto the gas bottle valve. (Note: this is a left-hand thread!)
  • Open the valve of the gas bottle.
  • Press the pressure relief valve button on the regulator outlet to fill the hose with gas (Fig 1).
  • Conduct a leak test using the pressure gauge (See section 4). If gas-tight, the gas appliance can be started.
  • When replacing the gas bottle, close the valve of the gas bottle first before unscrewing the regulator.

Leak Test:

  • Ensure the regulator is connected to the gas appliance via the gas hose.
  • The gas valve of the appliance must be in the closed position.
  • Confirm the regulator is securely attached to the gas bottle valve.
  • Slowly open the gas bottle valve. The regulator and gas hose will fill with gas. Close the gas valve again.
  • Check if the pointer of the manometer is in the green indicator zone. Wait for 2 minutes. If the pointer remains in the same position, the installation is gas-tight. (See section 4)
  • If the gauge pointer is in the yellow or blue area, there may be a gas leak. (See section 4)
  • Visually inspect the gas installation using a leak detection spray or soapy water to identify any leaks.
  • Do not operate the gas appliance if there is a gas leak.

Leaks

  • Do not use any device that leaks, is damaged, or does not function properly (defective).
  • If you suspect a gas leak, apply soapy water to the connection points (the regulator should not be fully submerged in soapy water as it may compromise its safe operation). If there is a leak, you will see bubbles coming from the leakage point.

The function of the overflow limiter

  • This regulator is equipped with a manual flow limiter
  • It activates when:
    • The gas appliance uses more gas than 110% of the nominal capacity of the regulator.
    • The gas hose becomes disconnected.
    • The gas hose becomes damaged or is accidentally cut.
  • The flow limiter will shut off the gas supply.
  • To reset, connect a hose to the regulator outlet and press the button to fill the gas hose with gas. Then, relight the gas appliance.

Manometer

Manometer – low level indicator

The gas level can be observed while gas is flowing between the gas cylinder and the appliance.

  • BLUE
    • The gas cylinder is empty and needs to be refilled. Gas pressure is lower than 0,3 bar
  • YELLOW
    • Gas cylinder is almost empty with 1-2 hours of use remaining. Will need refilling soon. Gas pressure is between 0,3 en 1 bar.
  • GREEN
    • Gas level is sufficient and ready for use. Gas pressure is between 1 en 12 bar

Warranty

  • The statutory warranty period applies. If the product is defective, please contact your retailer or the manufacturer’s branch in your country (see www.cadacinternational.com/support).
  • For repair and warranty processing, please include the following documents when you send in the product:
    • A copy of the receipt with purchasing date,
    • A reason for the claim or description of the fault.
  • Note that self-repair or non-professional repair can have safety consequences and might void the warranty.

CONTACTS

DOMETIC MOBILE COOKING NETHERLANDS B.V.

DOMETIC MOBILE COOKING UK LTD.

  • 114 Deanfield Court, Link59 Business Park Clitheroe, Lancashire, BB7 1QS United Kingdom
  • Tel: +44 (0) 333 2000363
  • Email: info@cadacuk.com

YOUR LOCAL DEALER:

NOTE! PRODUCT MAY VARY FROM ILLUSTRATIONS

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals