EPEVER LS-LPLI Series Charge Controller & LED Driver User Manual

October 27, 2023
EPEVER

EPEVER LS-LPLI Series Charge Controller & LED Driver

Overview

The LS LPLI series controller combines the solar charge controller and LED constant current driver in one unit. It is ideal for solar LED lighting, especially for the LED lamp application, which requires dimmer function. The advanced pulse width modulation charging methods enables system charging and discharging management to obtain the most radical optimization. Make the system cost reduce and increase system flexibility.

Features:

  • Apply to lead-acid battery and lithium battery
  • Lithium battery self-activating function
  • Lithium battery low-temperature protection function
  • Intelligent power mode with 365-day lighting control technology
  • Load power reduction automatically
  • Load power limitation function
  • Maximum output efficiency of 96%
  • Digital precision constant current control and the control accuracy are less than±2%
  • Discharging power calculation and real-time energy statistics recording function
  • Configurable multiple load control modes, LED rated current, and the current percentage
  • Load test function for detecting the system
  • Extensive electronic protections
  • Without any button, parameter setting via RC-10 and FC-01 with IR function.
  • Fully encapsulated PCB, IP68 protection
  • Aluminum housing for better cooling

Product Features

  1. Charging Status LED indicator
  2. Battery Status LED indicato
  3. Temperature Sensor ※
  4. PV Positive and Negative Wires
  5. Battery Positive and Negative Wires
  6. Load Positive and Negative Wires
  7. Infrared Receiver Module
  8. Infrared LED

If the temperature sensor connection is short-circuited or open-circuit, the controller charges or discharges the battery at 25℃ and no temperature compensation.

Wiring

Reference for Serial connection of LED

Connection Order

  1. Connect components to the charge controller in the sequence, as shown in Figure 2 Wiring, and pay much attention to the “+” and “-.” Please don’t insert the fuse or turn on the breaker during the installation. When disconnecting the system, reverse the order.
  2. After powering on the controller, check the controller’s battery LED indicator; it usually is green. Otherwise, please refer to chapter 8.
  3. Connect a fuse in series through battery positive (+) in the circuit. The battery circuit fuse must be 1.25 to 2 times the rated current. The installed distance is within 150mm.

Load self-test function
The load is ON when the controller power on for 10 seconds. After 10 seconds, it restores the working mode setting.

EPEVER-LS-LPLI-Series-Charge-Controller-amp-LED-
Driver-2

LED Indicators

Indicator Color Status Instruction
**** **** Green **** On Solid PV connection normal but low

voltage(irradiance) from PV, no charging
Green| Slowly Flashing(1Hz)| In charging
Green| Fast Flashing(4Hz)| PV reverse polarity
Green| OFF| No PV voltage(night time) or PV connection problem
****| Green| On Solid| Normal
Green| Slowly Flashing(1Hz)| Full
Green| Fast Flashing(4Hz)| Over voltage
Orange| On Solid| Under voltage
Red| On Solid| Over discharged
Red| Slowly Flashing(1Hz)| Battery Overheating
All indicators| Green and orange| Flashing two times| Set parameters successfully

Load Working Mode

  1. Manual Mode

  2. Light ON/OFF(default)

    • Turn-On voltage (Adjustable): 5V(12Vsystem), delay10min.
    • Turn-Off voltage (Adjustable): 6V(12Vsystem), delay10min.
  3. Light ON + Timer
    Light ON + Timer1

    Light ON + Timer2

    Light ON + Timer3
    EPEVER-LS-LPLI-Series-Charge-Controller-amp-LED-
Driver-8
    ** Item| Default | Range
    ---|---|---
    Mode1| Mode2/3
    | | 0-2.6A(LS101240LPLI)
    LED Rated Current|
    0.35A| 0-2.0A(LS102460LPLI)
    | | 0-4.0A(LS101260/2024120LPLI)
    Timer1|
    2H| 1H| 00:00—23:59H
    LED Rated Current Percentage|
    100%| 100%| 0—100%
    Timer2|
    2H| 1H| 00:00—23:59H
    LED Rated Current Percentage|
    80%| 50%| 0—100%
    | | |
    ---|---|---|---
    Timer3 LED Rated Current Percentage|
    2H**

50%

| 0H

0%

| 00:00—23:59H

0—100%

Timer4/5 LED Rated Current Percentage| 0H

0%

| 0H

0%

| 00:00—23:59H

0—100%

Timer6 LED Rated Current Percentage| 0H

0%

| 2H

100%

| 00:00—23:59H

0—100%

  1. Time Control
    Control the load on/off time by setting the real-time clock.

  2. Intelligent Power Mode
    When the battery voltage goes lower than the “Reduce Power Start Voltage (adjustable),” the intelligent power reduction mode is enabled. The LED output current is automatically reduced in linear with the battery’s voltage drop. When the battery voltage goes lower than the “Reduce Power End Voltage (adjustable),” the LED output current is 2% of the rated load current. The minimum percentage can be set to 1%). Also, when the battery voltage is higher than “Reduce Power Start Voltage,” the controller exits the intelligent power reduction mode.

Setting Operation

There are two methods to check and set the controller’s parameters:

  1. IR Remote Controller—RC-10
  2. Super Parameter Programmer—FC-01

This method can realize one-key setting operation which is suitable for bulk quantity products setting or applied in the projects.
NOTE: Please refer to the user manual of handheld device.

Protection

Protection Conditions Status
PV Reverse Polarity When the battery is correctly connecting,

the PV can be reversed.

| **** The controller is no damage
**** Battery Reverse Polarity| When the PV is not connected, or the connection is reversed, the battery can be reversed.

WARNING: Controller is damaged when the PV connection is correct, and the

battery connection is reversed!

Battery Over Voltage| The battery voltage reaches the OVD| Stop charging
Battery Over Discharge| The battery voltage reaches the LVD| Stop discharging
Battery Overheating| The temperature sensor is higher than 65℃| Output is OFF
The temperature sensor is less than 55℃| Output is ON
Li-battery Low Temperature | The temperature sensor is less than the low-temperature value| Stop charging or discharge
The temperature sensor is higher than the low-temperature value| Begin charging or discharge
**** Load Short Circuit| Load current ≥2.5 times rated current

In one short circuit, the output is OFF 5s; Two short circuits, the output is OFF 10s; Three short circuits, the output is OFF 15s; Four short circuits, the output is OFF 20s; Five short circuits, the output is OFF 25s; Six short circuits, the output is OFF

| Output is OFF Clear the fault: Restart the controller or wait for one night-day cycle (night time>3

hours).

Load Open Circuit(Load over voltage)| Max. load voltage≥68V One open circuit, the output is OFF 5s; Two open circuits, the output is OFF 10s; Three open circuits, the output is OFF 15s; Four open circuits, the output is OFF 20s; Five open circuits, the output is OFF 25s; Six open circuits, the output is OFF 5s; Seven open circuits, the output is OFF 5s| Output is OFF (Cycle to perform)

If selecting a lithium battery, set the low-temperature value(LTV) according to the specification; otherwise, the lithium battery is damaged.

Troubleshooting

Faults Possible reasons Troubleshooting

Charging LED indicator off during daytime when sunshine falls on PV

modules properly

| PV array disconnection| Confirm that PV and battery wire connections are correct and tight
**** No LED indicator| Min.9V can start up the controller.| Measure the battery voltage with a

multi-meter. Min.9V can start up the controller.

Battery LED indicator green Fast Flashing| **** Battery over voltage| ①Disconnect the solar array and measure the battery voltage; ②

Change the controller; ③ Change the battery

Battery LED indicator red| ①Battery over discharged| When the battery voltage is restored

to or above setpoint (low voltage reconnect voltage), the load work

Battery Status LED red indicator flashing| **** Battery Overheating| The controller automatically stops

working. When the temperature is below 50 ºC, the controller resumes

All the LED indicator flashing(battery red| System voltage error| Check whether the battery voltage matches the controller’s working
indicator flashing)| | voltage. Please change to a suitable battery or reset the working voltage
---|---|---
**** Powering on normally, the load is off| ①The connecting wires are error or virtual connection

②Load mode is wrong

③The controller does not match with the LED light.

④Output short circuit

| ①Check the connecting cables

②Check the load mode and parameter

③The voltage of the LED light source is not in the output voltage range of the controller

④Check the connecting cables and

LED light source

**** The dimming function is invalid| The controller does not match with the LED light source. This product is a step-up current control; if the input voltage is lower than the rated voltage,

it is not working.

| ① Relace the LED light

②Reduce system rated voltage grade, and replace the product model For example, switch the 24V system to the 12V system, and replace the corresponding controller.

① When the battery is over discharged, the battery indicator will be red. The load will be off all the time before the voltage is more than the Low Voltage Reconnect Voltage (LVRV). To judge the system is normal or not, firstly measuring the battery voltage, whether it is more than LVRV; if not, restarting the controller to detect the load.

Technical Specifications

Models

Item

| LS101240LPLI| LS101260LPLI| LS102460LPLI| LS2024120LPLI
---|---|---|---|---
Nominal system voltage| 12VDC| 12/24VDC
Rated charge current| 10A| 10A| 10A| 20A
Max. PV open circuit voltage| 30V| 50V
Battery input voltage range| 9~16V| 9~32V
Max. output power| 40W/12V| 60W/12V| 30W/12V

60W/24V

| 60W/12V

120W/24V

Max. output Current| 2.6A| 4.0A| 2.0A| 4.0A
Output voltage range| (Max. Battery Voltage +2V)~60V
Load open circuit voltage| 60V
Maximum output efficiency| 96%
Output current control accuracy| ≤2%
Battery Type| Lead-acid battery: Sealed(default)/Gel/Flooded/User
Lithium battery: LiFePO4/Li-NiCoMn/User
Lead-acid battery| Equalization Voltage▼| Sealed:14.6V; Flooded:14.8V;User:9-17V
Boost Voltage▼| Sealed:14.4V;Gel:14.2V;Flooded:14.6V;User:9-17V
Float Voltage▼| Sealed/Gel/Flooded:13.8V; User:9-17V
Reduce Power Start

Voltage ▼

| Sealed/Gel/Flooded:12.2V; User:9-17V
Reduce Power End Voltage ▼| Sealed/Gel/Flooded:12.0V; User:9-17V
Low Voltage

Reconnect Voltage▼

| Sealed/Gel/Flooded:12.6V; User:9-17V
Low Voltage Disconnect Voltage▼| Sealed/Gel/Flooded:11.1V; User:9-17V
Lithium battery| Boost Voltage▼| LiFePO4(4s):14.5V/Li- NiCoMn(3s):12.5V/User:9-17V
Reduce Power Start Voltage ▼| LiFePO4(4s):12.8V/Li-NiCoMn(3s):12.2V/User:9-17V
Reduce Power End Voltage ▼| LiFePO4(4s):12.0V/Li-NiCoMn(3s):10.5V/User:9-17V
Low Voltage Reconnect Voltage▼| LiFePO4(4s):12.8V/Li- NiCoMn(3s):10.5V/User:9-17V
Low Voltage Disconnect Voltage▼| LiFePO4(4s):11.1V/Li- NiCoMn(3s):9.3V/User:9-17V
Self-consumption| ≤18mA(12V);≤23mA(24V)
Charge Circuit Voltage Drop| ≤0.14V
Com. way| IR
Com. distance of IR| <6m
Working environment temperature| -40℃~+55℃
Enclosure| IP68(1.5m,72h)
Overall dimension(mm)| 87x60x22.8| 87x63x24.8| 87x63x24.8| 108.5x88x25.6
Mounting dimension(mm)| 80| 80| 80| 100.5
Mounting hole size(mm)| Φ4| Φ4| Φ4| Φ5
Power cable| PV/BAT:14AWG/2.5mm2 LOAD: 18AWG/1.0mm2| PV/BAT: 12AWG/4.0mm2 LOAD: 18AWG/1.0mm2
Net weight| 0.18kg| 0.21kg| 0.21kg| 0.40kg

  • When selecting a lithium battery, the controller cannot automatically recognize the nominal system voltage and has no temperature compensation.
  • The parameters are the 12V system at 25 ºC, double the values in the 24V system.

Disclaimer

This warranty does not apply under the following conditions:

  • Damage from improper use or use in an unsuitable environment.
  • PV or load current, voltage, or power is exceeding the rated value of the controller.
  • The controller’s working temperature exceeds the limit working temperature.
  • User disassembly or attempted to repair the controller without permission.
  • The controller is damaged due to natural elements such as lighting.
  • The controller is damaged during transportation and shipment.

Tel: +86-10-82894896/82894112/+86-752-3889706