Safety Precautions
Caution
- During construction, please install in strict accordance with the Use Instructions.
- Improper installation will cause accidents such as falling, electric shock and fire.
- This lamp is an indoor appliance, and is only suitable for installing on the ceiling. Please do not install it in the place shown on the right.
- Avoid causing accidents such as falling, electric shock and fire.
- Do not modify the lamp to avoid accidents such as falling, electric shock and fire.
- The power supply applied shall not exceed the specified values (input voltage 220V-240V ~, frequency 50/60Hz).
- Avoid causing accidents such as electric shock and fire.
- Do not apply impact force to the lens, otherwise it may cause the lens to fall.
- Do not use lenses with notch or crack, otherwise the lenses may fall.
- Please do not modify the lamp and replace the components. Otherwise, it may cause accidents such as electric shock and fire.
- When the lamp gets exceptional, disconnect the power supply quickly. And contact the sales company or construction company. Avoid causing accidents such as electric shock and fire.
- The external flexible cable or cord of the lamp cannot be replaced, if it is damaged, the lamp should be discarded
Cautions
-
The temperature under the lamp is very high. Please keep the distance between the lamp and the irradiated surface more than 1m. Otherwise, it may cause fire.
-
Please use this lamp at room temperature.
-
The LED light source has color differences, and even for the products of the same model, there are differences in light color and brightness.
-
The lamps are waterproof for indoor use (IP grade is IP65). If you need to use them in humid environment, please purchase waterproof connector with IP grade above IP65.
-
Please avoid direct sunlight and do not use it in high temperature, acidic or alkaline environment.
-
Please inspect it once a year by yourself according to the “Construction Record”, and entrust experts from the installation company to carry out regular inspection once every 3 years.
-
If regular inspection is not carried out, there will be a very low probability of accidents such as falling, electric shock, fire, etc.
-
The light source inside this lamp should be replaced by the manufacturer or its service agent or a person with similar qualifications.
Warning, Risk of Electric Shock
Installation Method of Components
Components Make sure to cut off the power supply before installation to prevent electric shock.
Preparation and confirmation before installation
- Make sure to remove the packaging accessories before installation.
- Before installation, make sure that all packaging accessories and adhesive tapes have been removed from the lamp to prevent fire.
- Please confirm that the ceiling has enough strength to bear the weight of the lamp.
- Avoid causing accidents such as lamp falling etc.
- Please choose suitable installation parts: patio hanging ring, hanging chain and hook (as shown in the above figure).
Install the lamp
-
Install the hook
- Secure the patio hanging ring and chain to the ceiling bracket, and then install the hook to the hanging chain.
- Ensure that the ceiling for installing the patio hanging ring is stable to avoid falling and damage of the lamp.
-
Install the hanging ring of the lamp
- Install the lamp ring to the lamp by turning it clockwise.
- Rotate the self-lock screw clockwise with screwdriver to secure the lamp hanging ring.
- Ensure that the self-locking screw completely fixes the lamp lifting ring to prevent the lamp from falling or damaging.
-
Install the lamp
- First, clip the hanging ring into the hook.
- Pass the safety rope on the lamp through the hook.
Connect the power cord
- In order to ensure safety, please cut off the power supply before connecting the external power cord.
- Fix the power cord with hanging chain by cable tie Protect the power cord from damage due to contact with the lamp body.
- It is recommended to use IP65 waterproof connector as shown in the following figure for wiring.
Please connect the external power cord to the waterproof connector correctly according to the wiring sign on the waterproof connector.
- After connection, the brown, blue, yellow/green wires shall not expose out of the casing of the waterproof connector.
- Do not place the waterproof connector on the lamp.
- N and L have installation direction, be sure to connect correctly.
- In order to ensure safety, please connect the ground wire first.
Improper connection will easily lead to fire, electric shock and other accidents.
Specification of lamp power cord:
Wire diameter 3 x 1.0mm2
L: brown wire
N: blue wire
Ground wire: yellow/green wire
Repair•Maintenance
- In order to use this product safely and efficiently, please clean and inspect it regularly (once every 6 months).
- Long-term use without inspection may lead to fire, electric shock, lamp falling and other accidents.
- When the lamp needs to be cleaned, please wipe it with soft cloth and neutral detergent and then wipe it with dry cloth.
- Please do not use detergents or organic solvents other than neutral detergents to wipe the lamp.
- Avoid causing discoloration, deterioration and strength reduction of or damage to the lighting fixture.
- Please do not spray insecticide on the lamp, otherwise it will cause discoloration of or damage to the lamp.
Construction Record
Installation Date| Light Source Model| Inspection Date| Inspection Items|
Remarks
---|---|---|---|---
Model No.| Rated Voltage /Frequency| Rated Current| PowerAngle| Beam| Power
Factor
---|---|---|---|---|---
NYV20100BE2A NYV20150BE2A| 220V-240V-| | | 60°|
NYV201106E2A| 50/60Hz| 0.35A| 75W (174 x 0.4W/LED module)| | 0.95
NYV201058E2A NYV20155BE2A| 220V-240V-| 0.35A| 75W (174 x 0.4W/LED module)|
90°| 0.95
NYV201158E2A| 50/60Hz| | | |
NYV201608E2A NYV201646E2A| 220V-240V-| 0.48A| 100W (232 x 0.4W/LED module)|
60°| 0.95
NYV20168BE2A| 50/60Hz| | | |
NYV20162BE2A NYV20166BE2A| 220V-240V-| 0.48A| 100W (232 x 0.4W/LED module)|
90°| 0.95
NYV20120BE2A| 50/60Hz| | | |
NYV201016E2A NYV201516E2A| 220V-240V-| 0.53A| 110W (232 x 0.44W/LED module)|
60°| 0.95
NYV20111BE2A| 50/60Hz| | | |
NYV201068E2A NYV201568E2A| 220V-240V-| | | |
NYV201168E2A| 50/60Hz| 0.53A| 110W (232 x 0.44W/LED module)| 90°| 0.95
NYV201028E2A NYV201528E2A NYV201128E2A| 220V-240V50/60Hz| 0.67A| 140W (290 x
0.45W/LED module)| 60°| 0.95
NYV20107BE2A NYV20157BE2A| 220V-240V-| | | |
NYV201176E2A| 50/60Hz| 0.67A| 140W (290 x 0.45W/LED module)| 90°| 0.95
NYV20161BE2A NYV20165BE2A| 220V-240V-| | | |
NYV201696E2A| 50/60Hz| 0.72A| 150W (290 x 0.48W/LED module)| 60°| 0.95
NYV20163BE2A NYV20167BE2A| 220V-240V-| | | 90°| 0.95
NYV20170BE2A| 50/60Hz| 0.72A| 150W (290 x 0.48W/LED module)| |
NYV201038E2A NYV201538E2A| 220V-240V-| 0.83A| 175W (348 x 0.47W/LED module)|
60°| 0.95
NYV20113BE2A| 50/60Hz| | | |
NYV20108BE2A NYV20158BE2A| 220V-240V-| | | |
NYV20118BE2A| 50/60Hz| 0.83A| 175W (348 x 0.47W/LED module)| 90°| 0.95
NYV20104BE2A NYV20154BE2A| 220V-240V-| 0.95A| 200W (406 x 0.46W/LED module)|
60°| 0.95
NYV20114BE2A| 50/60Hz| | | |
NYV201098E2A NYV201598E2A| 220V-240V-| 0.95A| 200W (406 x 0.46W/LED module)|
90°| 0.95
NYV20119BE2A| 50/60Hz| 0.95A| 200W (406 x 0.46W/LED module)| 90°| 0.95
- The style and color of lamps are subject to real products.
- Change is made without prior notice.
Panasonic Manufacturing (Beijing) Co., Ltd.
Origin : China
Address : No. 1, North Tongji Rd., Beijing
Economic-Technological Development Area, Beijing
Postal Code : 100176 Tel: (010) 67882438
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>