EMPIRE DVP36FP3 Direct Vent Zero Clearance Gas Fireplace Heater Owner’s Manual
- August 26, 2024
- Empire
Table of Contents
- DVP36FP3 Direct Vent Zero Clearance Gas Fireplace Heater
- IMPORTANT SAFETY INFORMATION
- SAFETY INFORMATION FOR USERS OF LP GAS
- REQUIREMENTS FOR MASSACHUSETTS
- INTRODUCTION
- SPECIFICATIONS
- VENT SYSTEM IDENTIFICATION
- SPECIAL VENT SYSTEMS
- FIREPLACE DIMENSIONS
- CLEARANCES
- LOCATING FIREPLACE
- GAS SUPPLY
- INSTALLATION
- VENTING FIREPLACE – TOP
- EXAMPLES – TOP VENT RUN
- VENTING FIREPLACE – REAR (NAT GAS MODELS ONLY)
- EXAMPLES – REAR VENT RUN
- REAR VENT CONVERSION
- VENT CLEARANCES
- 6 5/8” FRAMING AND FINISHING
- TERMINATION CLEARANCES
- HORIZONTAL TERMINATION
- VERTICAL TERMINATION
- DVVK-4F FLEX VENT INSTRUCTIONS
- DVVK-4FV DIRECT VENT TERMINATION KIT
- DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS
- PROPANE/LP GAS CONVERSION
- LOG PLACEMENT (4 LOG SET)
- MILLIVOLT SYSTEM OPERATING INSTRUCTIONS
- MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM
- MILLIVOLT SYSTEM STANDING PILOT LIGHTING INSTRUCTIONS
- MILLIVOLT SYSTEM STANDING PILOT TROUBLESHOOTING
- DIRECT IGNITION LIGHTING INSTRUCTIONS
- DIRECT IGNITION WIRING DIAGRAM
- OPTIONAL REMOTE CONTROL
- INITIAL START UP GAS LINE PURGE
- DIRECT IGNITION TROUBLESHOOTING
- DIRECT IGNITION PROPANE/LP GAS CONVERSION
- IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS
- IPI ELECTRONIC SYSTEM WIRING DIAGRAM
- INTERMITTENT PILOT LIGHTING INSTRUCTIONS
- INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING
- RF OPERATING INSTRUCTIONS
- RF MAINTENANCE INSTRUCTIONS
- RF WIRING DIAGRAM
- RF STANDING PILOT LIGHTING INSTRUCTIONS
- MAINTENANCE AND SERVICE
- PARTS LIST
- PARTS VIEW
- MASTER PARTS DISTRIBUTOR LIST
- HOW TO ORDER REPAIR PARTS
- FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION
- JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
- OPTIONAL BRICK LINER INSTALLATION INSTRUCTIONS
- ACCESSORIES
- WARRANTY
- APPLIANCE SERVICE HISTORY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
This Owner’s Manual is provided and hosted by Appliance Factory
Parts.
Appliance Factory Parts
Experts in BBQ, Humidifier, & Appliance Parts
1-800-955-7075
White Mountain Hearth
DVP36FP9
Owner’s Manual
Shop genuine replacement parts for White Mountain Hearth
DVP36FP9
DVP36FP3 Direct Vent Zero Clearance Gas Fireplace Heater
Find Your White Mountain Hearth Fireplace Parts – Select From 539
Models
——– Manual continues below ——–
INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vi-cinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is
provided with this appliance and shall be installed for the protection of
children and other at-risk individuals.
NOTE: Barrier required, but may be sold separately.
DIRECT VENT ZERO CLEARANCE GAS FIREPLACE HEATER MILLIVOLT STANDING PILOT
DVP36FP3(0,1,2,3)(N,P)-5
INTERMITTENT PILOT
DVP36FP7(0,1,2,3)(N,P)-6
DIRECT IGNITION
DVP36FP5(0,1,2,3)N-1
REMOTE RF
DVP36FP9(1,3)(N,P)-6
WARNING
If not installed, operated and maintained in accordance with the
manufacturer’s instructions, this product could expose you to substances in
fuel or from fuel combustion which can cause death or serious illness.
This appliance may be installed in an aftermarket, permanently located,
manufactured home (USA only) or mobile home, where not prohibited by state or
local codes.
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a
certified kit is used.
We suggest that our gas hearth products be installed and serviced by profes- sionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as NFt Gas Specialists.
IMPORTANT SAFETY INFORMATION
Before enclosing the vent pipe assembly, operate the appliance to ensure it is
venting properly.
DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED
DANGER: Indicates a hazardous situation which, if not avoided, will result
in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE: Addresses practices not related to personal injury.
-
If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
The base referred to above does not mean the fireproof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile. -
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
-
Young children should be carefully supervised when they are in the same room as the appliance.
-
Clothing or other flammable material should not be placed on or near the appliance.
-
Adequate accessibility clearances for servicing and proper operation.
-
This appliance must not share or be connected to a flue serving a separate solid-fuel burning appliance.
-
Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapor and liquids.
-
Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this appliance.
-
The flow of combustion and ventilation air must not be obstructed in any way.
-
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children, and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house.
To restrict access to a fireplace or stove, install an adjust-able safety gate to keep toddlers young children, and other at-risk individuals out of the room and away from hot surfaces. -
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. Barrier required, but may be sold separately.
-
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
-
Any safety screen, guard, or barrier removed for servicing an appliance must be replaced prior to operating the appliance.
-
Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies.
-
The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance. Work should be done by a qualified service person.
-
Keep burner and control compartment clean.
-
Vent cap is hot while fireplace is in operation.
-
Installation and repair should be done by a QUALIFIED SERVICE PERSON. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
-
DO NOT put anything around the fireplace that will obstruct the flow of ventilation air.
-
Clearance in accordance with local installation codes and the requirements of the gas supplier.
-
DO keep the appliance area clear and free from combustible material, gasoline and other flammable vapors and liquids.
-
DO examine venting system periodically and replace damaged parts.
-
DO make a periodic visual check of pilot and burners. Clean and replace damaged parts.
-
CAUTION: The glass used in your fireplace is tempered glass. If the glass is cracked or damaged in any way, it should be replaced only with a complete glass frame assembly from Empire. See parts list on Pages 64 and 65 for ordering.
-
DO NOT use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.
-
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
SAFETY INFORMATION FOR USERS OF LP GAS
Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In
its natural state, propane is odorless and colorless. You may not know all the
following safety precautions which can protect both you and your family from
an accident.
Read them carefully now, then review them point by point with the members of
your household. Someday when there may not be a minute to lose, everyone’s
safety will depend on knowing exactly what to do. If, after reading the
following information, you
feel you still need more information, please contact your gas supplier.
LP-GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas because of the
odorant put in the LP-Gas.
That’s your signal to go into immediate action!
-
Do not operate electric switches, light matches, use your phone.
Do not do anything that could ignite the gas. -
Get everyone out of the building, vehicle, trailer, or area. Do that IMMEDIATELY.
-
Close all gas tank or cylinder supply valves.
-
LP-Gas is heavier than air and may settle in low areas such as basements. When you have reason to suspect a gas leak, keep out of basements and other low areas. Stay out until firefighters declare them to be safe.
-
Use your neighbor’s phone and call a trained LP-Gas service person and the fire department. Even though you may not continue to smell gas, do not turn on the gas again. Do not re-enter the building, vehicle, trailer, or area.
-
Finally, let the service man and firefighters check for escaped gas. Have them air out the area before you return. Properly trained LP-Gas service people should repair the leak, then check and relight the gas appliance for you.
NO ODOR DETECTED – ODOR FADE
Some people cannot smell well. Some people cannot smell the odor of the
chemical put into the gas. You must find out if you can smell the odorant in
propane. Smoking can decrease your ability to smell. Being around an odor for
a time can affect your sensitivity or ability to detect that odor. Sometimes
other odors in the area mask the gas odor. People may not smell the gas odor
or their minds are on something else. Thinking about smelling a gas odor can
make it easier to smell.
The odorant in LP-Gas is colorless, and it can fade under some circumstances.
For example, if there is an underground leak, the movement of the gas through
soil can filter the odorant.
Odorants in LP-Gas also are subject to oxidation. This fading can occur if
there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into walls, masonry
and other materials and fabrics in a room. That will take some of the odorant
out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could vary at
different levels. Since it is heavier than air, there may be more odor at
lower levels. Always be sensitive to the slightest gas odor. If you detect any
odor, treat it as a serious leak. Immediately
go into action as instructed earlier.
SOME POINTS TO REMEMBER
- Learn to recognize the odor of LP-Gas. Your local LP-Gas Dealer can give you a “Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP-Gas has a weak or abnormal odor, call your LP-Gas Dealer.
- If you are not qualified, do not light pilot lights, perform service, or make adjustments to appliances on the LP-Gas system. If you are qualified, consciously think about the odor of LP-Gas prior to and while lighting pilot lights or performing service or making adjustments.
- Sometimes a basement or a closed-up house has a musty smell that can cover up the LP-Gas odor. Do not try to light pilot lights, perform service, or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP-Gas.
- Odor fade, due to oxidation by rust or adsorption on walls of new cylinders and tanks, is possible. Therefore, people should be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in new tanks, or reinstalled old tanks, if they are filled and allowed to set too long before refilling. Cylinders and tanks which have been out of service for a time may develop internal rust which will cause odor fade. If such conditions are suspected to exist, a periodic sniff test of the gas is advisable. If you have any question about the gas odor, call your LP-Gas dealer. A periodic sniff test of the LP-Gas is a good safety measure under any condition.
- If, at any time, you do not smell the LP-Gas odorant and you think you should, assume you have a leak. Then take the same immediate action recommended above for the occasion when you do detect the odorized LP-Gas.
- If you experience a complete “gas out,” (the container is under no vapor pressure), turn the tank valve off immediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices. If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank. Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty.
REQUIREMENTS FOR MASSACHUSETTS
For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
-
INSTALLATION OF CARBON MONOXIDE DETECTORS.
At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty days to comply with the above requirements; provided, however, that during said thirty day period, a battery operated carbon monoxide detector with an alarm shall be installed. -
APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/ UL 2034 listed and IAS certified.
-
SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than 1/2 inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
-
INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a) 1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED.
When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instruction.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
INTRODUCTION
Instructions to Installer
- Installer must leave instruction manual with owner after installation.
- Installer must have owner fill out and mail warranty card supplied with the fireplace.
- Installer should show owner how to start and operate the fireplace.
This direct vent gas fireplace heater is designed to operate with all combustion air being siphoned from the outside of the building and all exhaust gases expelled to the outside of the building. The information contained in this manual pertains to all models and gas control systems unless otherwise noted.
WARNING: : This unit is not for use with solid fuels. Appliance
Certification
This fireplace is design certified in accordance with American National
Standard/CSA Standard ANSI Z21.88/CSA 2.33 and by Underwriters Laboratories as
a Direct Vent Gas Fireplace Heater and shall be installed according to these
instructions.
Consult your local building code agency, prior to installation, to ensure
compliance with local codes-including permits and inspections.
The fireplace, when installed, must be electrically grounded in accordance
with local codes or, in absence of local codes, with the National Electric
Code ANSI/NFPA 70 or Canadian Electric code, CSA C22.1, if an external
electrical source is utilized.
These models may be installed in a bedroom or bed-sitting room in the U.S.A.
and Canada.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or
accessories and repair and servicing of equipment shall be performed only by a
qualified agency. The term “qualified agency” means any individual, firm,
corporation or company which either in person or through a representative is
engaged in and is responsible for (a) the installation or replacement of gas
piping or (b) the connection, installation, repair or servicing of equipment,
who is experienced in such work, familiar with all precautions required and
has complied with all the requirements of the authority having jurisdiction.
Commonwealth of Massachusetts: The installation must be made by a licensed
plumber or gas fitter in the Commonwealth of Massachusetts.
The installation must conform with local codes or, in the absence of ocal
codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 Natural Gas and
Propane Installation Code, or CSA B149.1 in Canada. Available from the
American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y.
10036.
Any alteration of the original design, installed other than as shown in these
instructions or use with a type of gas not shown on the rating plate is the
responsibility of the person and company making the change.
Warning: ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS.
Improper installation or use of the fireplace can cause serious injury or
death from fire, burns, explosions, or carbon monoxide poisoning.
Important
All correspondence should refer to complete Model Number, Serial Number and
type of gas.
High Altitude
When installing this unit at an elevation above 2000 feet (in the United
States) it may be necessary to decrease the input rating by changing the
existing burner orifice to a smaller size. Generally, input should be reduced
4 percent for each 1000 feet above sea level. However, if the heating value of
the gas has been reduced, this general rule may not apply. Check with local
gas utility for proper orifice size identification.
Canadian High Altitude
Altitude: 0-4500 feet (0-1370 m)
When installing this unit at an elevation above 4500 feet (in Canada), check
with local authorities.
Consult your local gas utility for assistance in determining the proper
orifice for location.
Preparation
This direct vent gas fireplace and its components are tested and safe when
installed in accordance with this Installation Manual.
Report to your dealer any parts damaged in shipment, specifically check glass
condition. Do not install unit with damaged, incomplete, or substitute parts.
Read all instructions before starting installation and follow these
instructions carefully during installation to insure maximum benefit and
safety. Failure to follow them will void your warranty and may present a fire
hazard.
The warranty will be voided by, and the warranter disclaims any responsibility
for the following actions:
- Installation of any damaged fireplace or vent system component.
- Modification of the fireplace or direct vent system.
- Installation other than as instructed by Empire Comfort Systems, Inc.
- Improper positioning of the logs, glass door or decorative rock.
- Installation and/or use of any component part not manufactured or approved by manufacturer.
SPECIFICATIONS
DVP36 Nat Models
Input Btu/hr Maximum| 25,000
Btu/hr Minimum (millivolt only)| 18,000
KWH (Maximum)| 7.3
(Minimum)| 5.2
Orifice| #41 (P256)
Air Shutter Opening| 1/8″ (DVP36FP(3,7,9))
1/4″ (DVP36FP5)
DVP36 LP Models
Input Btu/hr Maximum| 27,000
Btu/hr Minimum (millivolt only)| 21,000
KWH (Maximum)| 7.9
(Minimum)| 5.2
Orifice| 1.55mm (P-258)
Air Shutter Opening| FULL OPEN
DVP36 Nat and LP Models
Height without standoff| 34 3/4″
Width| 39″
Depth| 19 7/8″
Gas Inlet Shutoff Valve (pipe)| 1/2″ NPT
NOTE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for optimum performance.
Venting Options | Description |
---|
DVVK-4TSP
(DVVK-4TS)| Top Vent Kit (Horizontal) – 4½” to 6″ wall thickness
DVVK-4TP
(DVVK-4T)| Top Vent Kit (Horizontal) – 8″ to 12″ wall thickness
DVVK-4RP
(DVVK-4R)| Rear Vent Kit (Horizontal) – 5″ to 7″ wall thickness
DVVK-4VP
(DVVK-4V)| Vertical Vent Kit
DVVK-4F| Horizontal Flex Vent Kit (4′ Flex)
DVVK-4RE| Horizontal Round Termination wall thickness (up to 11 7/16″)
DV822| Vinyl Siding Kit for DVVK-4RE
DVVK-4FV| Vertical Flex Vent Kit
DVEK-10| 10′ Vent Extension Kit
DVEK-25| 25′ Vent Extension Kit
NOTE: Rear vent installation can only be vented on natural gas.
Remote Control Options & Accessories | Description |
---|---|
FRBC | Millivolt/IP Battery Remote ON/OFF |
FRBTC | Millivolt/IP Battery Remote T-Stat |
TMW | Millivolt/IP Wireless Wall Thermostat |
TRW | Millivolt/IP Reed Switch Wall Thermostat |
FWS-1 | Direct Ignition/Millivolt/IP Wall Switch |
FREC | Electric Remote |
FIREPLACE BARRIER SCREENS
SCREEN MODEL| DESCRIPTION| FIREPLACE MODELS USED ON
DVFB36TBL| Fireplace Barrier Screen, Matte Black| DVP36FP
Note: A firescreen is required for operation of the appliance, but are sold separately. Follow the instructions that come with your firescreen for proper installation.
VENT SYSTEM IDENTIFICATION
Begin the vent system installation by selecting the type of venting to be
installed and the path that it will take. Verify that clearances are met
throughout the path of the venting system. Determine if the fireplace is to be
vented out the top or out the rear.
NOTICE: Some fireplaces cannot be vented out the rear of the fireplace.
Determine how the vent system will be terminated out the side of the house or
through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to the “Special
Vent Systems” section in this manual to determine what systems are acceptable.
Check all clearances and venting components. Identify if any problems existing
in the vent system.
Use Figure 22 on page 17 for top venting, or Figure 32 on page 21 for rear
venting to eliminate issues after installation. Check pipe diameter on vent
system and fireplace to verify the size is the same.
NOTICE: All outer connection joints must be sealed with aluminum tape,
screws or silicone sealant rated above 300°F/149°C. The inner flue joints do
not require any sealant. Special venting components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers
and pricing.
Special DV Vent Kits
Available from Empire Comfort Systems, Inc. Dealers”
DVVK-4VP
(DVVK-4V)| Direct-Vent Fireplace Vent Kit – Vertical, Includes 46DVA- VCH,
46DVA-F6 and 46DVA-SC
DVVK-4TP
(DVVK-4T)| Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to 11
inch wall thickness, Includes 46DVA-HC, 46DVA-E90, 46DVA-09, 46DVA-08A and
46DVA-WT
DVVK-4RP
(DVVK-4R)| Direct-Vent Fireplace Vent Kit for Rear Vent, 5 to 7 inch wall
thickness, (standard thru-the-wall venting) includes 46DVA- 06, 46DVA-HC and
46DVA-WT
DVVK-4RE| Direct-Vent Fireplace Vent Kit For Rear Vent, Thru-the-wall for 5 to
13 3/4 inch wall thickness.
DVVK-4TSP
(DVVK-RTS)| Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to 7
inch wall thickness, Includes 46DVA-HC, 46DVA-E90, 46DVA-06 and 46DVA-WT
DVVK-4FV| Vertical Flex Vent Kit 4″ x 7″
VIB6A| Vertical Inlet Baffle Kit For 6 5/8″ diameter.
VIB7A| Vertical Inlet Baffle Kit For 7″ diameter.
SPECIAL VENT SYSTEMS
The following vent systems are acceptable for use with the DVP36 series
fireplaces:
Simpson Duravent® GS 4″ – 6 ⅝”
American Metal Products 4″ – 6 ⅝”
Selkirk Direct-Temp® 4″ – 6 ⅝”
Security Secure Vent® 4″ – 6 ⅝”
Excel DV Venting 4” – 6 ⅝”
MetalFab SureSeal® 4” – 6⅝”
BDM Manufacturing
Empire Horizontal Round Termination Kits – DVVK-4RE, DVVK-4FRE, DVVK-4FREVS
,DVVK-4REVS
Empire Flexvent Kit DVVK-4F
Empire Flexvent Kit DVVK-4FV Vertical Flex Vent Kit
FIREPLACE DIMENSIONS
| DIMENSION
---|---
A| 39″ (990 mm)
B| 36″ (914 mm)
C| 25 1/16″ (637 mm)
D| 37 5/8″ (956 mm)
E| 34 3/4″ (857mm)
F| 19 7/8″ (505 mm)
G| 26 1/2″ (673 mm)
H| 7 1/8″ (181 mm)
I| 27″ (686 mm)
J| 13 1/2″(343 mm)
K| 12 3/4″ (324 mm)
CLEARANCES
Clearance to Combustibles
Back| 0″ (0 mm)
Side| 0″ (0 mm)
Floor| 0″ (0 mm)
Top Stand-off| 0″ (0 mm)
Top Framing Edge| 3″ (76 mm)
Note A: See Figure 5 for maximum mantel depth.
Note B: See Figure 5 for minimum height above unit.
Combustible Material
No greeting cards, stockings or ornamentation of any type should be placed on
or attached to the fireplace. The flow of heat can ignite combustibles.
Mantel Chart Clearances
Clearance from top of fireplace to ceiling is 36”
Clearance from side of fireplace to adjacent sidewall is 6”. See Figure 6.
LOCATING FIREPLACE
Note:** Island and Room Divider installation is possible as long as the
horizontal portion of the vent system does not exceed 20 feet with a minimum
vertical run of 8 feet. See details in Venting Section.
*When you install your Direct Vent Fireplace in Room divider or Flat on wall corner positions, a minimum of 6 inches clearance must be maintained from the perpendicular wall and the front edge of the appliance.
GAS SUPPLY
The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code.
Recommended Gas Pipe Diameter
Pipe Length| Schedule 40 Pipe Inside Diameter| Tubing, Type L
Outside Diameter
| Nat.| L.P.| Nat.| L.P.
0-10ft 0-3m| 1/2″
12.7mm| 3/8″
9.5mm| 1/2″
12.7mm| 3/8″
9.5mm
11-40ft
4-12m| 1/2″
12.7mm| 1/2″
12.7mm| 5/8″
15.9mm| 1/2″
12.7mm
41-100ft
13-30m| 1/2″
12.7mm| 1/2″
12.7mm| 3/4″
19mm| 1/2″
12.7mm
101-150ft
31-46m| 3/4″
19mm| 1/2″
12.7mm| 7/8″
22.2mm| 3/4″
1.9 mm
NOTE: Never use plastic pipe. Check to confirm whether your local codes
allow copper tubing or galvanized.
NOTE: Since some municipalities have additional local codes, it is always
best to consult your local authority and installation code.
The use of the following gas connectors is recommended:
— ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and Fittings.
— ANS Z21.45 Assembled Flexible Appliance Connectors of Other
Than All-Metal Construction
The above connectors may be used if acceptable by the authority having
jurisdiction. The state of Massachusetts requires that a flexible appliance
connector cannot exceed three feet in length.
FLEXIBLE GAS LINE CONNECTION
| Gas Supply Pressure (inches w.c.)
---|---
Minimum| Normal| Maximum
Natural Gas| 4.5″| 7.0″| 14.0″
LP (Propane)| 10.8″| 11.0″| 14.0″
| Manifold Pressure (inches w.c.)
Normal (HI)
Natural Gas| 3.5″
LP (Propane)| 10.0″
*Note: Remote “RF” Models – 10.5″ w.c. maximum
Installing a New Main Gas Cock
Each appliance should have its own manual gas cock.
A manual main gas cock should be located in the vicinity of the unit.
Where none exists, or where its size or location is not adequate, contact your
local authorized installer for installation or relocation.
Compounds used on threaded joints of gas piping shall be resistant to the
action of liquefied petroleum gases. The gas lines must be checked for leaks
by the installer. This should be done with a soap solution watching for
bubbles on all exposed connections, and if unexposed, a pressure test should
be made.
Never use an exposed flame to check for leaks. Appliance must be disconnected
from piping at inlet of control valve and pipe capped or plugged for pressure
test. Never pressure test with appliance connected; control valve will sustain
damage!
NOTE: The millivolt gas controls are equipped with a captured screw ype
pressure test point, therefore it is not necessary to provide a 1/8” test
point up stream of the control.
On direct ignition valves, hex plugs may be replaced with hose fittings for
pressure checks, then reinstalled before operating fireplace.
When using copper or flex connector use only approved fittings.
The appliance and it’s individual shut off valve must be disconnected from
supply piping system during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing
its individual manual shut off valve during any pressure testing of the gas
supply piping system at test pressures equal to or less than 1/2 psig
(3.5kPa).
CAUTION: If one of the procedures results in pressures in excess of 1/2
psig (14” w.c.) (3.5 kPa) on the fireplace gas valve, it will result in a
hazardous condition.
Checking Manifold Pressures
Both Propane and Natural gas valves have a built-in pressure regulator in the
gas valve. Natural gas models will have a manifold pressure of approximately
3.5” w.c. (.871kPa) at the valve outlet with the inlet pressure to the valve
from a minimum of 4.5” w.c.
(1.120kPa) for the purpose of input adjustment to a maximum of 14.0” w.c.
(3.484kPa). Propane gas models will have a manifold pressure approximately
10.0” w.c. (2.49kPa) at the valve outlet with the inlet pressure to the valve
from a minimum of 10.8” w.c.
(2.68kPa) for the purpose of input adjustment to a maximum of 14.0” w.c.
(3.484kPa).
INSTALLATION
Framing and Finishing
-
Choose unit location.
-
Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame. See Figure 10B.
-
Attach fireplace to frame using nailing flange. Preset depth to suit facing material (adjustable to 1/2”, 5/8” or 3/4” depths).
NOTICE: Fireplace must mount flush to facing material. If facing material requires more depth than 3/4”, mark and drill two 1/8” holes into fireplace side at appropriate depth. Bend standoff tabs as needed to move fireplace flush with facing material.
See Figure 10A. -
Use eight 1/2” hex-head screws supplied in hardware package, to screw through slotted holes in nailing flange and then screw into pre-drilled holes on fireplace side. Measure from face of fireplace to face of nailing flange to determine final depth.
Vent Pipe Clearance
Note: Maintain one inch of clearance around top vent pipe. See Figure 11.
For rear vent, maintain a minimum 1” clearance to the bottom and sides of the
vent, and 3” clearance to combustibles above the vent pipe. See Figure 12.
Flush Mount Mantel Installation
The fireplace must extend 3/4” beyond finished wall surface when using a flush
mount mantel. Refer to Figure 13 to locate nailing flanges on fireplace sides.
Mark and drill two 1/8” holes into fireplace side to mount each nailing
flange. Use eight 1/2” hex-head screws supplied in hardware package to attach
nailing flanges to fireplace sides.
Attention: When fireplace is installed in optional full cabinet mantel or
corner mantel the four nailing flanges shown in Figure 13 will not be
installed on the side of outer casing. The fireplace will be attached to the
full cabinet mantel or corner mantel with the two nailing flanges located on
the top of the outer casing assembly.
Framing
Fireplace framing can be built before or after the fireplace is set in place.
Framing should be positioned to accommodate wall covering and fireplace facing
material. The fireplace framing should be constructed of 2 x 4 lumber or
heavier. The framing headers may rest on the fireplace standoffs. Refer to
Figure 14 for minimum framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS ANDVERIFY FRAMING METHODS, AND WALL
COVERING DETAILS BEFORE FRAMING CONSTRUCTION BEGINS.
Framing dimension “A” includes a three inch clearance for standoffs on
firebox. After installing firebox into framing, the finished wall surface must
cover the three inch opening above the firebox.
Note: For finishing to top of fireplace, refer to Figure 15.
| DVP36
---|---
“A”| 37 3/4″ (962 mm)
“B”| 39 3/8” (1000 mm)
“C”| 19 7/8″ (505 mm)
Attention: Add 3-3/4” to “A” dimensions when using a flush mantel base.
WARNING: If a base or mantel is not used and the appliance is installed
directly on carpeting, tile or other combustible material other than wood
flooring, it shall be installed on a metal or wood panel extending the full
width and depth of the appliance. The vertical dimension in Figure 14 must be
adjusted when a metal or wood panel is placed beneath the appliance.
Finishing
Finish the walls with the material of your choice. Figure 5 on page 10 shows
the minimum vertical and corresponding maximum horizontal dimensions of
mantels or other combustible projections above the top front edge of the
fireplace.
Only non-combustible materials may be used to cover the black fireplace front.
WARNING: When finishing the fireplace never obstruct or modify the air
inlet/outlet louvers in any manner. Provide adequate clearances around air
openings into the combustion chamber.
CAUTION: If the joints between the finished wall and the fireplace
surround (top and sides) are sealed, a 300°F minimum sealant material must be
used. These joints are not required to be sealed. Only non-combustible
material (using 300°F minimum
adhesive if needed), can be applied as facing to the fireplace surround.
Flush Wall Installation Combustible Surround Installation
Attention: Cold climate installation recommendation: When installing this
unit against a non-insulated exterior wall, it is recommended that the outer
walls be insulated to conform toapplicable insulation codes.
Vent Runs
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned and
installed. These include the direct vent system, gas piping for the appliance
and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
- A flat, hard combustible (burnable) surface.
- A raised wooden platform.
- Four corner supports. (Example: Four concrete masonry blocks.) These supports must be positioned so they contact all four perimeter edges on the bottom of the unit (if allowed by local codes).
NOTICE: Discard insulation and retainer when venting from the top of the
fireplace. See page 23.
TOP, 90° ELBOW WITH HORIZONTAL TERMINATION REAR ONLY, STRAIGHT OUT THE
BACK
“A” | “B” |
---|---|
6″ | 5 1/8″ to 6 1/2″ |
9″ | 8 1/8″ to 9 1/2″ |
12″ | 11 1/8″ to 12 1/2″ |
TOP, 90° ELBOW TO HORIZONTAL OUT THE WALL
“A” | “B” | “C” |
---|---|---|
6″ | 11 1/4″ to 12 3/4″ | 4 3/4″ to 6 1/4″ |
9″ | 14 1/4″ to 15 3/4″ | 7 3/4″ to 9 1/4″ |
12″ | 17 1/4″ to 18 3/4″ | 10 3/4″ to 12 1/4″ |
CORNER INSTALLATION TOP, 90° ELBOW TO HORIZONTAL OUT THE WALL LP and Nat models
Dim. | DVP36 |
---|---|
A | 44 7/8″ (114 cm) |
B | 31 3/4″ (81 cm) |
C | 13 7/16″ (34 cm) |
D | 63 7/16″ (161 cm) |
CORNER INSTALLATION REAR, 45° ELBOW TO HORIZONTAL OUT THE WALL Nat models only
| DVP36
---|---
“A”| “B”
6″| 4″ to 5 1/2″
9″| 6″ to 7 1/2″
12″| 9″ to 10 1/2″
VENTING FIREPLACE – TOP
To Use the Vent Graph
-
Determine the height of the center of the horizontal vent pipe.
Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line. -
From the point of this intersection, draw a vertical line to the bottom of the graph.
-
Select the indicated dimension, and position the unit in accordance with same.
EXAMPLE A:
If the vertical dimension from the floor of the unit is 35 feet, the
horizontal run to the outer wall flange must not exceed 6.5 feet.
EXAMPLE B:
If the vertical dimension from the floor of the unit is 6.5 feet, the
horizontal run to the outer wall flange must not exceed 14.5 feet. SPECIAL
NOTE: For each 45 degree elbow installed in the horizontal run, the length of
the horizontal run MUST be reduced by 18″ (45cm). This does not apply if the
45 degree elbows are installed on the vertical part of the vent system. Reduce
3′ for every 90° elbow.
Example: According to the chart the maximum horizontal vent length is 20′ and
if two 45 degree elbows are required in the horizontal vent it must be reduced
to 17′.
The maximum number of 45 degree elbows permitted per side wall installation is
two. These elbows can be installed in either the vertical or horizontal run.
Note: On vertical venting the first elbow does not get counted.
Note: LP and Nat gas models can be top vented.
Venting Graph (Dimensions in Feet)
TOP EXIT – VERTICAL AND HORIZONTAL TERMINATION (DIMENSIONS IN FEET)
Below Grade Installation
When it is not possible to meet the required vent terminal clearances of 12”
(305mm) above grade level, a snorkel kit is recommended.
It allows installation depth down to 7” (178mm) below grade level.
The 7” (178mm) is measured from the center of the horizontal vent pipe as it
penetrates through the wall.
Ensure the sidewall venting clearances are observed. If venting system is
installed below ground, we recommend a window well with adequate and proper
drainage to be installed around the termination area. Examples of possible
venting systems using one 90° elbow. Eight feet is listed as minimum vertical
vent run with 20 feet of maximum horizontal vent run. Vertical dimensions are
based on centerline to centerline of pipe. Horizontal dimensions are based on
centerline of pipe to end of termination. Examples of possible venting systems
using two 90° elbows. V is listed as minimum vertical dimensions and H1 + H2
is listed as total of maximum horizontal dimensions. The maximum vertical and
horizontal distances for two 90° elbows as shown in Figure 20 is 20 feet.
Attention: Refer to Figure 22 for additional venting requirements. SEE GRAPH
FOR PERMISSIBLE “H” AND “V” DIMENSIONS
NOTE: H1 AND H2 MUST BE ADDED TOGETHER TO USE CHART. MINIMUM HOLE
LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90
DEGREE ELBOW OFF TOP OF FIREPLACE
FIREPLACE SERIES | HARD ELBOW DIMENSIONS |
---|---|
“A” | “B” |
DVP36FP | 43-1/2″ (1105mm) |
FIREPLACE SERIES | FLEX PIPE 90 DEGREE BEND |
--- | --- |
“A” | “B” |
DVP36FP | 45″ (1143mm) |
Positioning the Fireplace
Determine the exact position of the appliance so the direct vent termination
will be centered (if possible) between two studs. This will avoid any extra
framing. All vent kit pipes should be assembled on the unit after the unit is
moved into the final position.
Cutting the Hole
After the fireplace has been positioned in its permanent location, the hole
through the exterior wall of the house can be cut. This hole must be 11”
(280mm) high x 10” (254mm) wide with its center line determined by the amount
of vertical rise and horizontal run of the termination. See Figure 26. When
locating the hole it must be noted that the bottom of the cap must be 12”
(305mm) above the ground level, and top of the cap must be no less than 18”
(457mm) below a combustible projection, and no closer than 9” (229mm) to any
wall running parallel to vent termination. See Figure 27.
EXAMPLES – TOP VENT RUN
VENTING FIREPLACE – REAR (NAT GAS MODELS ONLY)
To Use the Vent Graph
- Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line.
- From the point of this intersection, draw a vertical line to the bottom of the graph.
- Select the indicated dimension, and position the unit in accordance with same.
EXAMPLE A:
If the vertical dimension from the floor of the unit is 12 feet, 4 inches the
horizontal run to the outer wall flange must not exceed 12 feet, 3 inches.
EXAMPLE B:
If the vertical dimension from the floor of the unit is 6 feet, 9 inches, the
horizontal run to the outer wall flange must not exceed 6 feet, 6 inches.
SPECIAL NOTE: For each 45 degree elbow installed in the horizontal run, the
length of the horizontal run MUST be reduced by 18″ (45cm). This does not
apply if the 45 degree elbows are installed on the vertical part of the vent
system. Reduce 3′ for every 90° elbow.
Example: According to the chart the maximum horizontal vent length is 20′
and if two 45 degree elbows are required in the horizontal vent it must be
reduced to 17′.
The maximum number of 45 degree elbows permitted per side wall installation is
two. These elbows can be installed in either the vertical or horizontal run.
Note: Only natural gas models can be rear vented.
Venting Graph (Dimensions in Feet)
EXAMPLES – REAR VENT RUN
REAR VENT CONVERSION
TOP VENTING (FROM FACTORY)
Converting flue take-off to rear venting
When switching out the flue and inlet vent collars to run horizontally off the
rear vent, the following steps must be taken.
- Remove the inlet vent collar (8 screws) and flue collar (4 screws) from the top of the fireplace, and set to the side.
- Remove the inlet cover plate and flue cover plate located on the back of the fireplace. These will be used to close the top flue and inlet openings.
- Insert the insulation retainer bracket and insulation into the top flue pipe before reinstalling the flue cover plate over the top flue with 4 screws.
- Reinstall the inlet cover plate over the top inlet opening with 4 screws. See illustration above..
- Install the flue collar assembly to the rear flue with 4 screws.
- Install the inlet vent collar to the rear of the fireplace with 8 screws.
- This completes the conversion for a rear vent application.
Note: for top vented installations, the insulation and retainer are to be removed from the flue pipe and discarded.
VENT CLEARANCES
| Canadian Installations1| US Installations2
---|---|---
A= Clearance above grade, veranda, porch, deck, or balcony| 12 in (30 cm)| 12
in (30cm)
B= Clearance to window or door that may be open| 6 in (15 cm) for appliances ≤
10,000 Btuh (3 kW), 12 in (30 cm) for appliances > 10,000 Btuh (3 kW) and ≤
100,000 Btuh (30 kW), 36 in (91 cm) for appliances
100,000 Btuh (30 kW)| 6 in (15 cm) for appliances ≤ 10,000 Btuh (3 kW), 9 in (23 cm) for appliances > 10,000 Btuh (3 kW) and ≤ 50,000
Btuh (15 kW), 12 in (30 cm) for appliances > 50,000
Btuh (15 kW)
C= Clearance to permanently closed window| 12 in (30 cm)| 12 in (30 cm)
D= Vertical clearance ventilated soffit located
above the terminal within a horizontal distance of
2 feet (61 cm) from the center line of the terminal| 24 in (61 cm)| 24 in (61 cm)
E= Clearance to unventilated| 12 in (30 cm)| 12 in (30 cm)
F= Clearance to outside corner| 6 in (15 cm)| 6 in (15 cm)
G= Clearance inside corner| 9 in (23 cm)| 9 in (23 cm)
H= Clearance to each side of center line extended
above meter/regulator assembly| 3 ft (91 cm) within a above the meter/regulator
assembly| 3 ft (91 cm)
ATTENTION: Vinyl Soffit, Vinyl Ceiling, Vinyl Overhang Disclaimer
Clearances are to heat resistant material (i.e. wood, metal). This does not
include vinyl. Empire Comfort Systems Inc. will not be heldresponsible for
heat damage caused from terminating under vinyl overhangs, vinyl ceilings or
vinyl ventilated/unventilated soffits.
| Canadian Installations1| US Installations2
---|---|---
I= Clearance to service| 3 ft (91 cm)| 6 ft
J= Clearance to nonmechanical air supply inlet to building or the combustion
air inlet to any other appliance| 6 in (15 cm) for appliances ≤ 10,000 Btuh (3
kW),
12 in (30 cm) for appliances > 10,000 Btuh (3 kW) and ≤ 100,000 Btuh (30 kW),
36 in (91 cm) for appliances > 100,000 Btuh (30 kW)| 6 in (15 cm) for
appliances ≤ 10,000 Btuh (3 kW), 9 in (23 cm) for appliances > 10,000 Btuh (3
kW) and ≤ 50,000 Btuh (15 kW), 12 in (30 cm) for appliances > 50,000 Btuh (15
kW)
K= Clearance to a mechanical air supply inlet| 6 ft (1.83 m)| 3 ft (91 cm)
above if within 10 ft (3 m) horizontally
L= Clearance above paved sidewalk or paved driveway located on public
property| 7 ft (2.13 m) †| 7 ft (2.13 m) †
M= Clearance under veranda, porch deck, or balcony| 12 in (30 cm) ‡| 12 in (30
cm) ‡
1| In accordance with the current CSA B149.1, Natural Gas and Propane Instal-
lation Code
2| In Accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
†| A vent shall not terminate directly above a sidewalk or paved driveway that
is located between two single family dwellings and serves both dwellings
‡| Permitted only if veranda,, porch, deck, or balcony is fully open on a
minimum of two sides beneath the floor.
*| For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, one of the following shall be indicated:
Clearance in accordance with local installation codes and the requirements of
the gas supplier.
6 5/8” FRAMING AND FINISHING
Installing Support Brackets
A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The
pipe supports should be placed around the pipe and nailed in place to framing
members. There MUST BE a 3 inch clearance to combustibles above 6 5/8 inch
diameter pipe and elbows and 1 inch clearance on both sides and bottom of 6
5/8 inch pipe to combustibles on all horizontal pipe sections and elbows.
Vertical runs of this vent systems must be supported every 4 feet above the
appliance flue outlet by wall brackets attached to the 6 5/8 inch vent pipe
and secured with nails or screws to structural framing members. Installing
Firestops
Firestops are required for safety whenever the vent system passes through an
interior wall, an exterior wall, or a ceiling. These firestops act as a
firebreak heat shield and as a means to insure that minimum clearances are
maintained to the vent system.
Horizontal runs in the vent system which pass through either interior or
exterior walls, require the use of wall firestops on both sides of the wall
through which the vent passes.
Position the firestops on both sides of the 10 inch x 11 inch hole, previously
cut. Secure with nails or screws. The heat shields of the firestops MUST BE
placed towards the top of the hole. Continue the vent run through the
firestops. See Figure 39. Vertical runs of this system which pass through
ceilings require the use of ONE ceiling firestop at the hole in each ceiling
through which the vent passes.
Position a plumb bob directly over the center of the vertical vent component
and mark the ceiling to establish the center point of the vent. Drill a hole
or drive a nail through this center point and check the floor above for any
obstructions such as wiring or plumbing runs. Reposition the appliance and
vent system, if necessary, to accommodate ceiling joists and/or obstructions.
Cut a 10 inch x 10 inch hole through the ceiling, using the center point
previously marked. Frame the hole with framing lumber the same size as the
ceiling joists. See Figure 40. If the area above the ceiling is NOT an attic,
position and secure the ceiling firestop on the ceiling side of the previously
cut and framed hole. See Figure 41. If the area above the ceiling is an attic,
position and secure the firestop on top of the previously framed hole. See
Figure 42.
NOTE: Remove insulation from the framed area in the attic before
installing the firestop and/or vent pipes. See Horizontal Termination Page 28
and Vertical Termination Pages 29-30.
TERMINATION CLEARANCES
Termination clearance for buildings with combustible and noncombustible
exteriors. Vertical Sidewall Installations
Important! Minimum clearance between vent pipes and combustible materials
is 3” (76mm) on top, and 1″ (25mm) on bottom and sides.
Important! When vent termination exits through foundation less than 20″
below siding outcrop, the vent pipe must extend outward so that the horizontal
vent terminal is located flush to, or beyond the outcrop siding.
Information on Various Venting Routes and Components
Important: It is always best to locate the fireplace in such a way that
minimizes the number of offsets and horizontal vent length.
Since it is very important that the venting system maintain its balance
between the combustion air intake and the flue gas exhaust, certain
limitations as to vent configurations apply and must be strictly adhered to.
The graph showing the relationship between vertical and horizontal side wall
venting will help to determine the various vent lengths allowable.
The horizontal vent run refers to the total length of vent pipe from the flue
collar of the fireplace to the face of the outer wall.
The maximum horizontal vent run is 20 feet (457 cm) when the vertical vent
rise is 8 feet (244 cm). See Figure 22, page 17.
Venting terminals shall not be recessed into wall or siding.
HORIZONTAL TERMINATION
NOTE: Termination cap should pass through the wall firestop from the
exterior of the building. Adjust the termination cap to its final exterior
position on the building.
WARNING: Termination cap must be positioned so that arrow is pointing up.
Attach the termination cap with the four wood screws provided.
Before attachment of the termination, run a bead of silicone sealant rated
above 250°F on its outside edge too, so as to make a seal to the exterior
wall.
NOTE: Wood screws can and should be replaced with appropriate fasteners
for use on stucco, brick, concrete or other types of siding.
CAUTION: If exterior walls are finished with vinyl siding (or materials
that could become discolored or warp), it is necessary to install a vinyl
siding standoff.
The vinyl siding standoff will be installed between the vent termination and
the exterior wall. See Figure 44. This horizontal vent termination bolts onto
the flat portion of the vinyl siding standoff, so an air space will exist
between the wall and the termination cap. For installations requiring a
vertical rise on the exterior of the building, 14-inch and 36-inch tall
Snorkel Terminations, as shown in Figure 45 are available. Follow the same
installation procedures as used for standard Horizontal Terminations. If the
Snorkel Termination must be installed below grade (i.e. basement applications,
proper drainage must be provided to prevent water from entering the Snorkel
Termination. See Figure 46. Do not attempt to enclose the Snorkel within the
wall or any other type of enclosure.
VERTICAL TERMINATION
Locate and mark the center point of the venting pipe. Using a nail on the
underside of the roof and drive this nail through this center point. Make the
outline of the roof hole around this center point.
NOTE: Size of the roof hole dimensions depend on the pitch of the roof. There
must be a 1 inch clearance (25mm) to the vertical pipe sections. This
clearance is to all combustible material.
Cover the opening of the vent pipe and cut and frame the roof hole.
Use framing lumber the same size as the roof rafters and install the frame
securely. Flashing anchored to frame must withstand high winds. The storm
collar is placed over this joint to make a water-tight seal. Non-hardening
sealant should be used to completely seal this flashing installation.
Determining Minimum Vent Height Above the Roof.
WARNING: Major U.S. building codes specify minimum chimney and/or vent
height above the roof top. These minimum heights are necessary in the interest
of safety. These specifications are summarized in Figure 47.
ROOF PITCH | H (Min.) |
---|---|
Flat to 6/12 | 12″ (305 mm) |
6/12 to 7/12 | 15″ (381 mm) |
Over 7/12 to 8/12 | 18″ (457 mm) |
Over 8/12 to 16/12 | 24″ (610 mm) |
Over 16/12 to 21/12 | 36″ (914 mm) |
Note that for steep roof pitches, the vent height must be increased. In high
wind conditions, nearby trees, adjoining roof lines, steep pitched roofs, and
other similar factors can result in poor draft, ordown-drafting. In these
cases, increasing the vent height may solve this problem. When terminating
the vent cap near an exterior wall or overhang, maintain minimum clearances as
shown in Figure 48.
General Maintenance
Conduct an inspection of the venting system semi-annually.
Recommended areas to inspect are as follows:
- Check areas of the venting system which are exposed to the elements for corrosion. These will appear as rust spots or streaks and, in extreme cases, holes. These components should immediately be replaced.
- Remove the cap and shine a flashlight down the vent. Remove any bird nests or other foreign material.
- Check for evidence of excessive condensate, such as water droplets forming in the inner liner and subsequently dripping out at joints. Condensate can cause corrosion of caps, pipe and fittings. It may be caused by having excessive lateral runs, too many elbows and exterior portions of the system being exposed to cold weather.
- Inspect joints to verify that no pipe sections or fittings have been disturbed and, consequently, loosened. Also, check mechanical supports, such as wall straps or plumbers’ tape for rigidity.
Venting terminal shall not be recessed into a wall or siding.
A removable panel or other means must be provided in the enclosure for visual
inspection of the flue connection.
NOTE: This also pertains to vertical vent systems installed on the
outside of the building.
Slide the vertical vent cap over the ends of the vent pipe and secure.
See Figure 49.
Installing the Vent System in a Chase
A chase is a vertical box-like structure built to enclose the gas appliance
and/or it’s vent system. Vertical vent runs on the outside of a building may
be, but are not required to be installed inside a chase. CAUTION:
Treatment of firestop spacers and construction of the chase may vary with the
type of building. These instructions are not substitutes for the requirements
of local building codes. Therefore, your local building codes must be checked
to determine the requirements for these steps.
NOTE: When installing this vent system in a chase, it is always good
building practice to insulate the chase as you would the outside walls of your
home. This is especially important for cold climate installations. Upon
completion of building your chase framing, install the vent system by
following the instructions in this manual.
Remember to build the chase large enough so that minimum clearance of
combustible materials (including insulation) to the vent system are
maintained.
Installation of Vertical Inlet Baffle
The vertical inlet baffle is to be used only in a completely vertical vent
installation. The vertical inlet baffle can be used when the vertical vent
rise is between 10 feet and 40 feet. To maintain the yellow flame in the main
burner, purchase Vertical Inlet baffle, VIB6A for use with 6 5/8″ diameter
vent systems, or the VIB7A for use with 7″ diameter vent systems. These are
available from your Empire Comfort Systems, Inc. distributor or dealer.
In a vertical vent rise the rear (yellow) flame on the main burner can be
reduced due to the drawing action from the flue exhaust pipe and the air inlet
pipe. A decrease in the height or the appearance of the yellow flame may occur
when the vertical vent rise is between 10 feet and 40 feet. To enhance the
yellow flame on the main burner, the vertical inlet baffle can be attached to
the direct vent high wind vertical top.
Please refer to the instructions included with the Air Inlet Baffle Kit for
proper installation.
Reassembly and Resealing Vent Pipe System
Attach vent pipe to inlet and outlet vent adaptor on fireplace in either the
vertical or horizontal position, replace horizontal and vertical pipe lengths,
elbows and horizontal or vertical termination kit.
All vent system components lock into place by sliding the concentric pipe
section with four equally spaced interior beads onto the appliance collar or
previously installed component end with four equally spaced indented sections.
When the internal beads of each starting outer pipe line up, rotate pipe
section clockwise 90° (approximately 3 inches). The vent pipe is now locked
together.
Continue replacing components per the vent system configuration.
Be certain that each succeeding vent component is securely fitted and locked
into the preceding component in the vent system.
Vertical Through the Roof Applications
Your Gas Fireplace has been approved for:
a) Vertical installations up to 40 feet in height.
b) Two sets of 45 degree elbow offsets within these vertical installations.
From 0 to a maximum of 8 ft. a vent pipe can be used between elbows.
c) Wall straps must be used to support offset pipe every 4′.
This application will require that you first determine the roof pitch and use
the appropriate venting components.
DVVK-4F FLEX VENT INSTRUCTIONS
The DVVK-4F FLEX VENT KIT includes the following components:
- Horizontal Termination Cap
- 4-foot section of Flex vent with spacers (4” flue/7” outer pipe)
- 4” diameter Flue adapter collar
- 7” diameter Outer Vent adapter collar
- Wall Firestop/Thimble Assembly
- Hardware pack that includes band clamps and screws
Flex venting can be installed either vertically or horizontally off of the
DVP36 Series fireplaces. When installing a horizontal vent run from top
connections, maintain at least ½” rise for every 12” of vent run. When venting
horizontal off the rear vent connections, allow a minimum rise of 2”. Refer to
Figure 57 when mounting termination near vinyl siding.
CAUTION: Always stretch and secure venting with wire or metal strapping to
ensure that the horizontal runs do not sag.
If space permits, it is generally easier to attach venting in the top vent
configuration.
Because of sharp edges, always use gloves when handling the flex vent
components.
Vent connections should overlap a minimum of 1” for proper sealing.
Always follow the general venting requirements for vent terminal location,
vent lengths, and clearance to combustible materials.
STEP-BY-STEP INSTALLATION
-
Unpack vent components and check that all items are included.
-
Check to see that the vent spacer springs are located around the flue vent at 8” and 12” intervals along its length. See Figure A. If not, stretch the spacer springs to about 15” long and wrap them around the flue, then interlock the ends of each spring about 2”. See Figure B. Maintain equal distance between spring spacers.
-
Remove the 6-⅝” diameter Vent collar from the fireplace.
Replace this collar with the 7” diameter Flex Vent adapter collar provided with the vent kit. -
Slide the Flex Vent flue pipe into the Outer Flex Vent pipe.
-
Install the Wall Firestop/Thimble assembly as required through the wall. Refer to the venting charts in the fireplace manual to determine the proper height and size of the vent opening. The minimum opening should be 9” wide by 11” high.
The minimum combustible clearance from the horizontal vent is 1” from sides and bottom, and 3” above the vent pipe. See Figure C. -
In most cases, after determining the length of the vent that is needed, it may be easier to install the flue and outer vent pipes to the Termination Cap first, then from the outside, feed the venting through the wall to the fireplace.
-
If the venting is to long, trim off any excess vent before attaching the vent end connectors.
CAUTION: Do not use force when installing the Horizontal Vent Termination into the flex venting. Always stretch venting out first, then cut off excessive vent material prior to sliding the vent termination into the flue and inlet venting. Forcing the termination cap into the flex venting will deform the flue venting, which will restrict the exhaust gases, and cause improper operation of the fireplace. -
Attach the Termination Cap to the outside of the house.
-
Prior to making the vent connections, apply high temperature sealant (1000 degree F min.) to the vent connections before securing with the band clamps provided.
NOTICE: the flue pipe end without the adapter is to be installed to the Termination Cap. -
Apply sealant to the outside of the flue pipe adapter and connect to the flex flue pipe. Then insert the adapter into the fireplace flue. Secure flue adapter to the fireplace flue with a minimum of two screws provided. See Figure D.
-
Attach the Outer Vent pipe to the 7” diameter Collar on the fireplace with a large band clamp provided. Sealant may also be used on the outer vent connections.
-
Check all vent connections for tightness. Make sure horizontal venting has the proper rise and combustible clearances required. Refer to venting charts in fireplace instruction manual.
DVVK-4FV DIRECT VENT TERMINATION KIT
This termination kit can only be used with Empire Comfort Systems direct vent
fireplaces listed for use with DVVK-4FV Vertical Flex Vent Kit. Please review
the instructions packaged with your fireplace and verify the fireplace model
number. Check that this
flex vent system is listed for use with your fireplace model prior to starting
the installation.
This vent kit may be installed as an OEM installation in a manufactured home
(USA only) or mobile home and must be installed in accordance with the
manufacturer’s instructions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240 MH.
CAUTION
All Fireplaces listed for use with the DVVK-4FV will operate safely when
installed in accordance with this instruction manual.
Read all instructions before starting installation, then follow these
instructions carefully to maximize fireplace performanceand safety.
Report damaged parts to your dealer.
WARNING
Any common venting of the gas appliance using the DV vent kit with other gas
appliances is not allowed. Do not connect this appliance to a chimney flue
servicing a separate solid fuelburning appliance.
WARNING
Failure to follow these instructions may create a possible fire hazard and
will void the warranty.
WARNING
Always maintain minimum clearances around vent systems.
The minimum clearance to combustibles for horizontal runs of vent pipe is 3
inches from the top, and 1 inch from the sides and bottom of the vent system.
Do not pack the open air spaces around the fireplace or flue with insulation
or other materials.
Any horizontal run must have a 1/4” rise for every one foot of run towards the
vent termination. The vent above the roof must terminate vertically.
WARNING
Contact your Local Building and Fire Officials about restrictions and
installation inspections in your area.
IMPORTANT SAFETY INFORMATION
- The vertical termination cap MUST be vented directly to the outside. The termination kit MUST NEVER be connected to a chimney flue(s) servicing a separate solid-fuel burning appliance or any other appliances.
- Vertical termination cap MUST NOT be mounted horizontally.
- The flexible vent pipe cannot be intermingled with any of the rigid vent pipe section(s). DO NOT connect two sections of flexible vent pipe together to achieve a longer length without the use of approved connectors.
- The installation must conform with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (in the United States) or with the current installation code CAN/CGA B149 (in Canada).
- Only Direct Vent fireplaces approved for use with Empire Comfort Systems, Inc. DVVK-4FV termination kit shall be used. See PARTS LIST/ILLUSTRATIONS section for vent component identification.
- Horizontal vent runs must be supported every 2 feet using wall straps. Vertical runs must be supported every 3 feet using wall straps. Slip wall straps loosely on to pipe. Attach installer provided straps to framing members using nails or screws.
- The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function.
- Please refer to the fireplace instructions for information on Termination Cap clearances.
DVVK-4FV DIRECT VENT TERMINATION KIT
PRE-INSTALLATION INFORMATION:
Items Required For Installation:
Tools | Building Supplies |
---|
Phillips Screwdriver Hammer Saw and/or saber saw Level Measuring Tape Electric
Drill and Bits Pliers
Square Tin Snips| Framing Materials Wall Finishing Materials
Caulking Material (Noncombustible) Support
Strap supplies
Before You Start:
Plan your installation. Read these instructions and the fireplace installation
manual before installing unit and vent system. Set unit in place and survey
how best to vent the unit. After the vent configuration has been decided,
stretch the flex pipe components out,
then trim off what will not be needed.
Refer to the fireplace installation manual for information on vertical venting
requirements. The maximum length of vent when using flex venting is 35 feet
total. Contact your dealer or distributor for information on flex vent
extension kits that may be added to the DVVK-4FV kit, in order to terminate up
to 35 feet. Available extension kits include the DVEK-10 (10’ Flex) or the
DVEK-25 (25’ Flex) extension kits. The extension kits include connection
hardware.
Installation of the Vertical Flex Termination Kit
WARNING
Ensure that the venting system exits the structure through the roof and does
not terminate less than 12 inches (305 mm) above the roof.
WARNING
Refer to your fireplace homeowner’s manual for the minimum and maximum venting
requirement of your fireplace prior to installation.
Failure to do so may cause a fire hazard.
WARNING
This flexible pipe termination kit is ONLY for vertical terminations.
WARNING
Any horizontal run section must have a 1/4” rise for every one foot of run
towards the vent termination. Never allow the vent pipe to run downward. This
could cause high temperatures and may present a fire hazard. This vertical kit
may incorporate two 90 degree bends, but must terminate vertically.
CAUTION
This flex vent kit can only be installed vertically off of the unit and must
terminate vertically.
WARNING
Because of sharp edges, always use gloves when handling the flex vent
components.
CAUTION
Vent connections should overlap a minimum of 1” for proper sealing.
CAUTION
Always stretch and secure venting with metal strapping secured with nails
(nails and strapping not supplied) to ensure that the flex vent runs remain
true.
Step-By-Step Installation
-
Unpack vent components and check all items for shipping damage.
-
For this venting system to operate as designed it is dependent on the use of all parts and procedures detailed in these instructions.
Failure to follow these instructions may potentially affect the performance of this vent system and the attached appliance. -
As per the fireplace manufacturer’s instructions, replace the existing 6 5/8” diameter fireplace vent adapter with the 7” diameter flex vent fireplace adapter included in the vent kit.
Install the adapter collar with the screws removed from the standard fireplace collar. Refer to the fireplace manual for additional information on the vent collar removal and installation. -
Once the fireplace location has been determined, mark the ceiling where the flex vent will pass through. Cut an opening for installation of the firestop thimble assembly. The opening must measure a minimum of 9-1/2” x 9-1/2” square. See Figure 51.
-
Next, determine the location for the cutout in the roof opening.This opening must be large enough to provide a minimum 1” air space clearance from the vertical vent pipe to any combustible framing.
-
Install the Firestop/Thimble assembly to the framed opening in the ceiling using common nails or screws.
Note: The thimble assembly is adjustable up or down as needed within the firestop. It is also designed with a pivoting firestop for use with 0 – 3/12 pitch cathedral ceilings. -
To begin vent system assembly, first layout all the vent components on the floor in the order in which they will be assembled.
-
Stretch the 4” diameter inner flex flue and 7” diameter outer flex vent to the maximum length of 6 feet.
-
Install the spring spacers provided around the 4” diameter flex flue at 1 foot intervals, then slide the flue pipe with spacers into the 7” diameter outer flex vent pipe. Make sure the springs are spaced evenly starting at 12 inches from the fireplace collar.
See Figure 52. -
With the flex vent assembly and the 48” long hard pipe components laid out on the floor, begin securing these parts together. First, apply a generous bead of silicone sealant to the inside of the 4” diameter flex flue (not the end with the pre-installed connector), then slide the flex flue over the 4” diameter hard pipe flue. Be sure to overlap at least 1-1/4”. Secure this connection with a 4” diameter band clamp provided. Be careful not to damage or tear the flex flue when tightening clamp.
-
Repeat the connection process for the outer 7” diameter flex vent to hard pipe connection. Use silicone sealant at this joint also, overlap at least 1-1/4”, then secure the joint with the 7” diameter band clamp provided. Be careful not to damage or tear the flex vent pipe when tightening the clamp.
-
While the venting is still on the floor, assemble the roof jack components as shown in Figure 53 and pre-install the roof jack assembly to the hard pipe approximately 18” from the top end of the hard pipe.
-
Now the pre-assembled vent system may be carried to the roof, then lowered through the roof cutout opening (see step 5). Feed the flex vent end down through the roof opening and firestop/thimble assembly installed in steps 4 through 6.
-
Secure the roof support assembly to the roof sheathing with at least four nails/screws through each support bracket. Check that the combustible clearances through the roof framing will maintain at least a 1” clearance from the vent pipe.
-
Determine how high the vent terminal should be located above the roof line based on the roof pitch information shown in Figure 54. Adjust the vent system height by loosening the pre-installed roof support pipe clamp and sliding the vent pipe up or down as pre-determined, then re-tighten the pipe clamp.
Install a couple of sheet metal screws through the pipe clamp into the outer hard vent pipe to lock in place. -
Check to make sure that the bottom end of the flex vent is long enough to reach the fireplace adapter collars. If too long, trim off the extra flex vent not needed.
ROOF PITCH| H (Min.)
---|---
Flat to 6/12| 12” (305 mm)
6/12 to 7/12| 15” (381 mm)
Over 7/12 to 8/12| 18” (457 mm)
Over 8/12 to 16/12| 24” (610 mm)
Over 16/12 to 21/12| 36” (914 mm) -
To attach the vent connections at the fireplace, be sure the 7” diameter adapter collar has been installed per step 3. Apply a bead of silicone sealant to the 4” diameter flex connector, then slide the flex pipe adapter collar into the fireplace flue collar and secure by installing a minimum of two screws through the flue collar and into the adapter. See Figure 55.
-
Apply sealant to the 7” diameter adapter collar, slide outer flex vent over the collar, then secure with a 7” diameter band clamp. See Figure 55.
-
Once the lower connections are made and the flex pipe is secured with support bands as required (3 feet minimum between supports) then the roof flashing canbe installed.
See Figure 56. -
Install the roof flashing, and seal using common constructions practices.
-
An additional storm collar band is provided in kit that may be used as an attic insulation shield. The collar can be installed around the flex pipe (or hard pipe) just above the firestop thimble. This collar will act as a shield to prevent blown insulation from entering the thimble.
-
To complete the vent installation, install the vent termination cap to the top of the hard vent pipe assembly. Mate up the flue and outer telescopes with the hard pipe assembly, then secure by installing a minimum of two sheet metal screws into the overlapped flanges of the cap and pipe.
-
Figure 56 shows a completed installation with components identified and other installation information such as heights and clearance to combustibles.
Vertical Flex Termination Kit
Item Number| Item Description| Repair Part No.| Quantity
Supplied
---|---|---|---
1| 4”/7” Vertical Termination Cap| MF100038| 1
2| Roof Support Kit| MF100503| 1
3| 2 Ply Alum Flex 4” Diameter by 6 ft.| MF04ALA2F006| 1
4| 2 Ply Alum Flex 7” Diameter by 6 ft.| MF07ALA2F006| 1
5| 4”/7” x 48” Rigid Pipe Assembly| MF100554| 1
6| Firestop Thimble Assembly| MF100124| 1
7| Roof Flashing (0/12 to 6/12)| MF100091| 1
8| 7” Flex Adapter Collar with Gasket| MF100524| 1
9| 7” Storm Collar| MF100147| 2
10| Spring Spacers| MF100548| 5
N/S| Clamp 4” Diameter| MF100330| 2
N/S| Clamp 7” Diameter| MF100534| 2
N/S| #8 x 1/2” Self Drilling Screws| N/A| 20
N/S| HT Silicone| N/A| 1
N/S| #8 x 5/8” Self Drilling Screws| N/A| 10
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS
CAUTION: Sharp edges, use protective gloves when installing.
Tools Needed for Installation: Sheet metal snips 5/16” nut driver
Phillips head screwdriver – #2
High temperature sealant or furnace cement rated for continuous use at 1,000 F
minimum Measuring tape
Parts Verification
See parts list on page 40 to verify components included in this vent kit prior
to installation.
NOTE: If installing onto wood, lap, or vinyl siding, the vinyl siding kit
should be used (sold separately, part number DV-822).
The vinyl siding vent kit, DV-822, is available from Empire Comfort Systems,
Inc. The depth is 3” (76 mm), which enables the vent cap to be extended away
from vinyl siding or projections. The wall depth plus the additional 3” (76
mm) depth of the vinyl siding vent cap extension should not exceed a total
depth of 13 3/4” (349 mm).
If wall depth exceeds 13 3/4” (349 mm), extend system using 6 5/8” (168 mm) x
4” (102 mm) rigid venting (see Fireplace Instructions for approved lengths).
See Figure 58. Installing Wall Thimble/Firestop Assembly
-
Fix fireplace to permanent location. If using rigid venting system, install up to the location where it will exit the building.
-
Cut hole in wall for wall thimble/firestop assembly into your combustible wall. See Figure 59. Note: On brick or block exterior wall a 7” (178 mm) diameter hole needs to be cut.
Measure the total wall thickness to determine whether or not the extension thimble is to be used. If the combustible wall depth is over 5 3/8” (137 mm), then the extension thimble should be used. See Figure 59. -
Install the wall thimble assembly through the framed opening so the firestop plate is on the interior wall. See Figure 59. Telescope section should extend all the way through the exterior wall. Attach with four 10 x 1” screws.
-
When placing the vent cap on an exterior wall covered with combustibles such as wood, lap, or vinyl siding, install the vinyl siding kit to the exterior wall sheathing. Cutting Vent Tubes
This is the most important part of the installation. With the fireplace (and the rigid venting system if used) fixed to its permanent location, the 6 5/8” (168 mm) diameter air inlet tube and the 4” (102 mm) diameter flue outlet tube are to be marked and cut using the following procedure. -
Attach the inlet tube to the outside mounting plate. Align tinnerman clips on the tabs of the air inlet tube to the holes on outside mounting plate, and fix with two #10 x 1/2” screws.
-
With the vinyl siding kit installed to wall (if necessary), insert the 6 5/8” (168 mm) diameter tube with outside mounting plate attached through hole in wall. Connect to collar on fireplace or rigid vent system. Measure between wall or vent cap extension and outside mounting plate. See Figures 60 and 61.
-
Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168 mm) diameter tube from the opposite end. Do not crimp or enlarge tube.
-
Attach the 4” (102 mm) diameter flue outlet tube onto the rigid venting system or directly to fireplace. Ensure the 4” (102 mm) diameter flue outlet tube is placed as far as possible onto the rigid venting system. Mark the 4” (102 mm) diameter flue outlet tube 2 1/2” (64 mm) beyond the vinyl siding kit or wall. See Figure 61. Remove the 4” (102 mm) diameter flue outlet tube from rigid venting system. When installing directly to fireplace, tape gasket needs to be used.
-
Mark or wrap tape completely around the tubes at the marked points to help in making a true cut. Do not crimp or enlarge tubes.
-
From outside: Push the 6 5/8” (168 mm) diameter inlet tube/ mounting plate onto end of rigid venting system to correct position. Fasten the outside mounting plate to the vinyl siding kit or wall with four 10 x 1 1/2” screws. (Ensure upward slope).
-
From inside: Attach the inlet tube to the collar on the back of the fireplace (or the rigid venting system) using three self tapping screws.
-
Seal the 4” (102 mm) diameter flue outlet tube. Follow instructions and diagram. See Figure 62. Note: Tape gasket to be applied prior to installing to fireplace flue outlet tube only. Tape gasket should not be used when mating the flue outlet tube to a rigid venting system.
-
Fasten 4” (102 mm) diameter flue outlet tube in place. Do not “twist” the flue outlet tube into the fireplace collar (or rigid venting system). Hold the tube by the seam and push in using a perpendicular “rocking” motion. This ensures the seam on the tube stay intact.
-
Fasten vent cap end using three 10 x 1/2” screws to mounting plate.
Follow correct option according to venting method.
Connecting Directly to Fireplace
If the air inlet and flue outlet tubes are to be connected directly to the
unit (no rigid venting system is being used), then the gasket provided must be
used to seal the 4” (102mm) flue outlet tube.
Peel the paper off the self-adhesive gasket and then wrap it around the end of
the tube (if tube was cut, it is recommended to use cut end) as shown in
Figure 62. Pull the gasket tight at all times while wrapping it around tube.
The gasket ends should align, to form complete seal. The overlapped section
should NOT come in contact with the seam in the tube. Apply high temperature
sealant to the opposite end of the tube (on the inside of the tube). The end
with the gasket will attach to the back of the unit.
Connecting to Rigid Vent System
If the air inlet and flue outlet tubes are to be connected to a rigid venting
system (and not directly to the back of the unit), then do not use the gasket
provided. High temperature sealant should be applied to the outside of the 4”
diameter (102mm) flue outlet tube (if tube was cut, it is recommended to use
cut end) and to the inside of the tube on the end that connects to the vent
cap.
PARTS LIST
INDEX NUMBER | PART NUMBER | DESCRIPTION |
---|---|---|
1 | DV769 | Vent Cap Assembly |
2 | 19193 | Outside Mounting Plate |
3 | 19194 | Air Inlet Tube |
4 | DV524 | Flue Outlet Tube |
5 | 19196 | Firestop/Thimble Assembly |
6 | 20527 | Gasket |
PROPANE/LP GAS CONVERSION
Model | AIR SHUTTER SETTINGS | BURNER ORIFICE |
---|---|---|
Opening “A” | Propane/LP Orifice | |
DVP36 | FULL OPEN | 1.55 mm |
Maxitrol Valve Conversion (Direct Ignition)
LOG PLACEMENT (4 LOG SET)
Before you begin: This fireplace is supplied with a set of four ceramic fiber
logs. Do not handle these logs with your bare hands. Always wear gloves to
prevent skin irritation from ceramic fibers.
After handling logs, wash your hands gently with soap and water to remove any
traces of fiber.
The positioning of logs is critical to safe and clean operation of this
fireplace. Sooting and other problems may result if the logs are not properly
and firmly positioned in the fireplace. Please refer to Figure 65, Figure 66,
and Figure 67 and corresponding WARNING, when completing the following log
placement steps.
-
Remove top louver, grasp louver, lift and pull forward.
-
Lower bottom louver, lift and hinge forward.
-
Release two glass frame spring clamps at bottom of firebox
-
Place rear (#1) log onto two pins on rear log support.
-
Place left, front (#2) log onto two left, front pins on burner pan.
-
Place right, front (#3) log onto two right, front pins on burner pan.
-
Place Branch (#4) onto one pin on rear log and one pin on front left log.
-
Place decorative rock in front of grates and sides of main burner.
ATTENTION: Do not place decorative rock on logs or on burner. The decorative rock should only be placed on the fireplace floor. -
After all logs are properly positioned, place small “dime” size pieces of Rockwool lightly across the front round “blue flame” ports. Place the ember material (Rockwool pieces) side by side.
Do not stack more than one layer of embers across the burner ports. See Figure -
Replace glass door onto firebox.
-
Secure the two glass frame spring clamps at bottom of firebox.
-
Align the tabs on top louver brackets with slots in front posts to secure top louver..
-
Close bottom louver. Lift slightly to engage the end tabs into the slots in fireplace sides to close louver panel.
WARNING
Failure to position the parts in accordance with this diagram or failure to
use only parts specifically approved with this appliance may result in
property damage or personal injury.
Attention: Do not use Figure 66 or Figure 67 to order logs. Refer to
parts view on page 66 and parts list on page 65 to order logs and/ or ember
material for your appropriate fireplace model.
Log Set Parts List
Index Number| Part Number| Description
1| R10349| Rear Log
2| R10350| Front Left Log
3| R10351| Front Right Log
4| R10352| Top Branch
WARNING
If flame lifts off burner and goes out, verify insulation and retainer were
removed. See page 15.
MILLIVOLT SYSTEM OPERATING INSTRUCTIONS
750 Millivolt System
The standing pilot (750 millivolt system) is a continuous burning pilot. The
pilot remains ON even when the main burner is OFF.
When you ignite the pilot, the thermopile produces millivolts (electrical
current) which energizes the magnet in the gas valve. After 30 seconds to one
minute time period you can release the gas control knob and the pilot will
stay ON. Allow your pilot flame to operate an additional one to two minutes
before you turn the gas control knob from the PILOT position to the ON
position. This time period allows the millivolts (electrical current) to
build-up to a sufficient level allowing the gas control to operate properly.
-
Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found in control compartment behind the door assembly.
CAUTION: During the initial purging and subsequent lightings, never allow the gas valve control knob to remain depressed in the “pilot” position without pushing the piezo ignitor button at least once every second. -
During the operating season, leave the control valve knob in the “ON” position. This will allow the pilot flame to remain lit. Turn the burner flame on or off with the fireplace REMOTE/OFF/ON switch, wall switch or remote controls.
NOTE: The gas control valve allows you to increase or decrease the height of the main burner flame. The control valve has a pressure regulator with a knob as shown in Figure 68. Rotate the knob clockwise to “HI” to increase the flame height and counterclockwise to “LO” to decrease the flame height. -
When the operating season is over, turn the REMOTE/OFF/ON switch to “OFF” and the control valve to “OFF”. The system, including the pilot light, will be shut down.
The OWNER should carefully read and follow these operating instructions at all
times. Lower the door assembly to view the gas controls for the fireplace.
Initial Lighting
Upon completing the gas line or turning the gas valve on after it has been in
the “OFF” position, a small amount of air will be in the lines.
When first lighting the fireplace, it will take a few minutes for the lines to
purge themselves of this air. Once the purging is complete, the fireplace will
light and operate satisfactorily.
Subsequent lightings of the appliance will not require such purging if the gas
valve is not turned to “OFF.”
Pilot Flame
The thermopile/thermocouple (standing pilot) tips should be covered with
flame.
MILLIVOLT SYSTEM OPERATING INSTRUCTIONS
STANDING PILOT OPERATING INSTRUCTIONS
REMOTE/OFF/ON Switch
The fireplace is equipped with a REMOTE/OFF/ON switch. A wire harness is
attached to the REMOTE/OFF/ON switch. The red, black and green (wires) female
push-ons attach to the REMOTE/OFF/ON switch. At the opposite end of the wire
harness, the black and green (wires) female push-ons attach to the gas valve.
An additional green wire and the red wire, which are stripped and bare, will
attach to one of the accessories that can be purchased for use with your
fireplace.
Operation of REMOTE/OFF/ON Switch with no Accessories To ignite main burner,
turn the control knob on the gas valve from the PILOT position to the ON
position. Turn the REMOTE/OFF/ON switch from the OFF position to the ON
position. The additional green wire and red wire, which are stripped and bare
are not used.
Wall Switch, FWS-1
Connect the green and red, stripped and bare, wires on the REMOTE/ OFF/ON
switch wire harness to the wall switch using wire nuts. Turn the REMOTE/OFF/ON
switch to the REMOTE position. Pivot the rocker switch on the FWS-1 to the ON
position.
Wall Thermostats (optional)
TRW – Wireless for Millivolt models
TMV – Reed switch for Millivolt models
Battery Operated Remote Controls, FRBC, FBRTC, and TRW
Connect the green and red, stripped and bare, wires on the REMOTE/OFF/ON
switch wire harness to the remote receiver that is a component in the remote
kit using wire nuts. Turn the REMOTE/ OFF/ON switch to the REMOTE position.
Follow instructions included with the remote to complete installation.
Note: If batteries fail in the remote, and immediate heat is desired,
turn the REMOTE/OFF/ON switch from the REMOTE position to the ON position.
Electric (120 volt) Operated Remote Control, FREC
Connect the green and red, stripped and bare, wires on the REMOTE/ OFF/ON
switch wire harness to the wires on remote receiver that is a component in the
FREC using wire nuts. Turn the REMOTE/ OFF/ON switch to the REMOTE position.
Follow instructions in the FREC to complete installation.
NOTE: If electric (120 volt) fails in FREC, and immediate heat is
desired, turn the REMOTE/OFF/ON switch from the REMOTE position to the ON
position.
Installation of Remote Receiver
Place remote receiver on the floor of fireplace behind the louver as far
forward as possible.
Attention: The Velcro loop and hook are not necessary in this
installation but can be used to secure remote receiver.
Refer to remote control installation and operating instructions for more
details on remote control.
Millivolt Control
The valve regulator controls the burner pressure which should be checked at
the pressure test point. Turn captured screw counter clockwise 2 or 3 turns
and then place tubing to pressure gauge over test point (Use test point “A”
closest to control knob). After taking pressure reading, be sure and turn
captured screw clockwise firmly to re-seal. Do not over torque. Check for gas
leaks.
Millivolt thermopile is self generating. Gas valve does not require 24 volts
or 110 volts.
Check System Operation
Millivolt system and all individual components may be checked with a millivolt
meter 0-1000 MV range.
It is important to use wire of a gauge proper for the length of the wire:
Recommended Wire Gauges
Maximum Length| Wire Gauge
1′ to 10′| 18
10′ to 25′| 16
25′ to 35′| 14
MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM
MILLIVOLT SYSTEM STANDING PILOT LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. Before lighting smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle
on the floor.
What To Do If You Smell Gas
-
Do not try to light any appliance.
-
Do not touch any electrical switch;
-
Do not use any phone in your building.
-
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions. -
If you cannot reach your gas supplier, call the fire depart-ment.
C. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or turn by hand, don’t try to repair it;
call a qualified service technician. Force or attempted repair may result in a
fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control which has been
under water.
LIGHTING INSTRUCTIONS
-
Stop! Read the safety information above.
-
Set REMOTE/OFF/ON switch to OFF.
-
Turn off all electric power to the appliance (if applicable).
-
Lower bottom louver assembly.
-
Push in gas control knob slightly and turn clockwise to “OFF.” Note: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.
-
Wait ten minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step.
-
Find pilot – Follow metal tube from gas control. The pilot is behind the burner on the right side.
-
Turn gas control knob counterclockwise to “PILOT.”
-
Push in control knob all the way and hold in. Repeatedly push the piezo ignitor button until the pilot is lit. Continue to hold the control knob in the for about one minute after the pilot is lit. Release knob, and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.
• If the control knob does not pop up when released, STOP and IMMEDIATELY call a qualified service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. -
Turn gas control knob counterclockwise to “ON.”
-
Close bottom louver assembly.
-
Turn on all electric power to the appliance (if applicable).
-
Set REMOTE/OFF/ON switch to desired setting.
TO TURN OFF GAS TO FIREPLACE
- Set REMOTE/OFF/ON switch to OFF.
- Turn off all electric power to the appliance if service is to be performed (if applicable).
- Lower bottom louver assembly.
- Push in gas control knob slightly and turn clockwise to “OFF.” Do not force.
- Close bottom louver assembly.
MILLIVOLT SYSTEM STANDING PILOT TROUBLESHOOTING
With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
-
Spark ignitor will not light pilot after repeated triggering of piezo ignitor button.
a. Defective ignitor (no spark electrode)
—Check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace ignitor.
b. No gas or low gas pressure.
—Check remote shut off valves from fireplace. Usually there is a valve near the main. There can be more than one valve between the fireplace and main.
—Low pressure can be caused by a variety of situations such as a bent line, too narrow diameter of pipe, or low line pressure. Consult with plumber or gas supplier.
c. No LP in tank.
—Check LP (propane) tank. Refill tank. -
Pilot will not stay lit after carefully following lighting instructions.
a. Defective thermocouple.
—Check that pilot flame impinges on thermocouple. Clean and/or adjust pilot for maximum flame impingement.
—Ensure the thermocouple connection at the gas valve is fully inserted and tight (hand tight plus 1/4 turn). Faulty thermocouple if reading is below specified minimum of 15 millivolts.
—Disconnect the thermocouple from the valve, place one millivolt meter lead wire on the end of the thermocouple and the other millivolt meter lead wire on the thermocouple copper wire. Start the pilot and hold the valve knob in. If the millivolt reading is less than 15 millivolt, replace the thermocouple.
b. Defective valve.
—If thermocouple is producing more than 15 millivolts, replace faulty valve. -
Pilot burning, no gas to burner, valve knob “ON”, REMOTE/
OFF/ON switch “ON.”
a. REMOTE/OFF/ON switch, wall switch, remote control or wires defective.
—Check REMOTE/OFF/ON switch and wires for proper connections. Place jumper wires across terminal at switch.
If burner comes on, replace defective switch. If OK, place jumper wires across switch wires at gas valve-if burner comes on, wires are faulty or connections are bad.
b. Thermopile may not be generating sufficient millivolts.
—If the pilot flame is not close enough physically to the thermopile, adjust the pilot flame.
—Be sure the wire connections from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket.
—Check the thermopile with a millivolt meter. Take the reading at TH-TP & TP terminals of the gas valve. The meter should read 350 millivolts minimum, while holding the valve knob depressed in the PILOT position, with the pilot lit, and the REMOTE/OFF/ON switch in the OFF position. Replace the faulty thermopile if the reading is below the specified minimum.
—With the pilot in the ON position, disconnect the thermopile leads from the valve. Take a reading at the thermopile leads.
The reading should be 350 millivolts minimum. Replace the thermopile if the reading is below the minimum.
c. Defective valve.
—Turn valve knob to ON. Place REMOTE/OFF/ON switch to ON. Check with millivolt meter at thermopile terminals.
Millivolt meter should read greater than 200 millivolts. If the reading is okay and the main burner does not ignite, replace the gas valve.
d. Plugged main burner orifice.
—Check main burner orifice for blockage and remove. -
Frequent pilot outage problem.
a. Pilot flame may be too high or too low, or blowing (high), causing pilot safety to drop out.
—Clean and adjust flame for maximum flame impingement on the thermocouple. Follow lighting instructions carefully. -
The pilot and main burner extinguish while in operation.
a. No LP (Propane) in tank.
Check LP (Propane) tank. Refill fuel tank.
b. Inner vent pipe leaking exhaust gases back into system
—Check for leaks.
c. Glass too loose, gasket leaks in corners after usage.
—Be certain glass assembly is installed correctly.
d. Horizontal vent improperly pitched.
—The horizontal vent cap should slope down only enough to prevent any water from entering the unit. The maximum downwards slope is 1/4 inch.
e. Bad thermopile or thermocouple.
—Replace if necessary.
f. Improper vent cap installation.
—Check for proper installation and freedom from debris or blockage. -
Glass soots.
a. Flame impingement on logs.
—Check and adjust log position. Contact Empire Comfort Systems, Inc.
b. Debris around throat of main burner.
—Inspect the opening at the base of the main burner. It is imperative that NO material be placed in this opening. -
Flame burns blue and lifts off main burner.
a. Insufficient oxygen being supplied.
—Check to make sure vent cap is installed properly and free of debris. Make sure that vent system joints are tight and have no leaks.
—Check to make sure that no material has been placed at the main burner base.
DIRECT IGNITION LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF
LIFE.
A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
- Do not touch any electrical switch
- Do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone.
- Follow the gas supplier’s instructions.
- If you can not reach your gas supplier, call the fire department.
B. Use only the wall switch or remote control switch to turn the gas control
on/off. Any attempted repairs or adjustments should be performed by a
qualified service technician. Applying force or attempted repair may result in
a fire or explosion.
C. Do not use this appliance if any part has been under water. Immediately
call a qualified service technician to inspect the appliance and to replace
any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
- STOP! Read the safety information above.
- Set the thermostat, if used, to the lowest setting.
- Turn off all electric power to the appliance.
- This appliance is equipped with an ignition device that auto- matically lights the burner. Do not try to light the burner by hand.
- Open bottom louver assembly.
- Turn gas line valve to “ON.”
- Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “A” in the safety information above. If you do not smell gas, go to the next step.
- Close bottom louver assembly.
- Turn on all electric power to the appliance.
- Set thermostat to desired setting (if available).
- If the appliance will not operate, follow the instructions “TO
TURN OFF GAS TO APPLIANCE,” and call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
- STOP! Read the safety information above.
- Turn off all electric power to the appliance.
- Open bottom louver assembly, or open the valve access door.
- Turn gas line valve to “OFF.”
- Close bottom louver assembly, or close valve access door.
DIRECT IGNITION WIRING DIAGRAM
LED CODES
Steady ON| Normal operation, power ON to control
2 Flashes| 3 unsuccessful ignition trials
3 Flashes| Main burner flame failed 4 times during a single heating cycle
4 Flashes| Interrupt power for 5 seconds to reset control
Steady Flash| Flame detected out of sequence
OPTIONAL REMOTE CONTROL
Electric (120 volt) Operated Remote Control (FREC)
- Disconnect 3-prong power cord from receptacle.
- Remove wire from 120 VAC hot terminal on control module.
- Connect female terminal from receiver onto 120 VAC hot terminal on control module.
- Connect remaining wire from remote control (male terminal) to (female terminal) on power cord removed from control module (step 2).
- Insert electric remote control power cord plug into the junction box on the right side of fireplace.
- Connect 3-prong plug into receptacle.
INITIAL START UP GAS LINE PURGE
NOTE: UNIT MUST BE PROPERLY GROUNDED FOR ELECTRONIC IGNITION TO FUNCTION.
On initial installation, or after extended periods where the fireplace has not
been used, gas lines may require purging.
The installer or qualified service person may use the following purge
procedures to prevent the delays that would be caused by waiting for the
lockout periods between tries for ignition.
PURGE PROCEDURE
- Remove glass door and place away from the fireplace.
- Turn on gas shut off valve. Follow ignition procedure.
- If burner does not light after spark sequence has ended, use an insulated jumper wire (see page 50) between terminal locations 12 and 13 for fast reset function.
- Interrupt power for 5 seconds. The green indicator light will blink 4 times repetitively. Then retry for ignition.
- Allow time for any raw gas to dissipate and repeat steps 3 and 4 until ignition is achieved.
- Turn burner off and install glass door frame assembly.
- Test ignition of burner with glass door in place.
DIRECT IGNITION TROUBLESHOOTING
With proper installation and maintenance, your new Direct Vent Gas Fireplace
will provide years of trouble-free service. If you do experience a problem,
refer to the troubleshooting guide below. This guide will assist a qualified
service person in the diagnosis of
problems and the corrective action to be taken.
SYMPTOM | CHECK | ACTION |
---|---|---|
No spark when system is turned to “ON” and reset cycle* has been completed |
Check for 120V between black “hot” line at control module and “white” return
at module| If 120V not present, check fuse or circuit breaker or repair wiring
leading to fireplace.
Main burner will light, but igniter continues to spark for several seconds and
then locks out (module will show two blinks on indicator light).| Disconnect
power to fireplace junction box and check that the “Hot-Black” wire is
connected to the gold receptacle screw side, and that the “Neutral – White”
wire is connected to the silver screw side. The green ground must also be
secured for proper operation.| Prior to rewiring the fireplace junction box,
check operation of the control system by running a grounded extension cord
from another standard wall receptacle outlet to the fireplace control system.
Follow purge reset procedure above in order to clear the light codes.
Spark for six seconds at ignitor, but no ignition of burner.| a. Check that
gas is turned on and system purged| Turn gas on and/or purge system
b. Check that tips of ignitor are directly above ports on main burner. Spark
is between electrodes and not from one electrode to burner.| Position
electrodes so tips are directly above burner port ports and about ¼” to 3/8″
above burner.
c. Check for 120V at each coil on the gas valve and listen for click,
indicating gas valve is opening.| If 120V present, but gas valve does not
click, replace gas valve.
Spark for six seconds, main burner lights, but goes out when spark stops.|
Check for clean ground path between electrode bracket and fireplace chassis.
Check wiring to wiring diagram label. Check for broken electrode on high-
tension lead attachment to module.| Clean, position according to wiring
diagram, and repair defective electric connections. If all electrical
connections are clean and correct, replace module.
Main burner lights normally and then goes out.| a. Check thermostat if
applicable.| Turn thermostat up to call for heat or replace
b. Check high-tension lead and connector for shorts.| Replace spark electrode
assembly
c. Refer to installation instructions troubleshooting guide for issues such as
venting.| Repair as required.
DIRECT IGNITION PROPANE/LP GAS CONVERSION
The conversion shall be carried out in accordance with the requirements of the
provincial authorities having jurisdiction and in accordance with the
requirements of the CSA B149.2 installation code (Canada) and with the
requirements of the National Fuel Gas Code Z223.1/NFPA 54 (United States).
WARNING: This conversion kit shall be installed by aqualified service
agency in accordance with the manufacturer’sinstructions and all applicable
codes and requirements of the authority having jurisdiction. If the
information in thisinstruction is not followed exactly, a fire, explosion,
orproduction of carbon monoxide may result causing property damage, personal
injury, or loss of life. The qualified service agency is responsible for the
proper installation of this kit. Theinstallation is not proper and complete
until the operation of the converted appliance is checked as specified in
themanufacturer’s instructions supplied with the kit.
Installer notice: Using an ink pen, fill out the required information on the
conversion label. Remove the backing from label and stick label in a visible
position on bottom of fireplace close to gas valve.
Installer notice: These instructions must be left with the appliance.
Instructions for converting your direct ignition fireplace from natural gas to
propane/LP gas.
All direct ignition fireplaces are shipped from the factory equipped to
operate on natural gas. To convert the direct ignition fireplace to operate on
propane/LP gas, follow the instructions on this page.
Please see the appropriate parts list for your model for parts includedwith
the direct ignition fireplace.
Check the items in the kit with the parts list. Notify the supplier of any
items that are missing before installing the conversion kit.
-
Turn off the gas supply.
-
Turn off the electrical supply to the appliance if so equipped.
-
Remove top louver and lower bottom louver.
-
Remove glass frame assembly.
-
Remove logs from burner assembly.
VALVE CONVERSION -
Remove plastic cap from regulator fitting. Unscrew fitting using a 11/16″ wrench. Turn fitting over so end of fitting marked “LPG”(red) screws into valve. Tighten fitting (snug only). Replace plastic cap.
-
Remove 1/4″ screw from air shutter.
-
Located to the right of electrodes is a burner hold-down tab. Using needle-nose pliers, bend burner hold-down tab off the main burner.
-
Remove main burner by pivoting main burner forward as you slide main burner from left to right. Be careful as you remove main burner in order to protect the electrodes from beingdamaged.
-
Remove air shutter from orifice fitting.
-
Remove natural gas main burner orifice from orifice fitting.
-
Install propane/LP main burner orifice marked 1.55 mm.
Important: Failure to install the correct orifice will result in unit over- firing that could overheat the appliance and result in a fire. -
Replace air shutter onto orifice fitting. Air shutter must be threaded and bottomed-out onto orifice fitting.
-
Replace main burner onto burner assembly. Place main burner beneath electrodes, slide main burner from right to left into burner location, and pivot main burner away from you and into air shutter.
-
Set air shutter opening at FULL OPEN.
-
Using needle-nose pliers, bend burner hold-down tab over main burner.
-
Refer to log placement, page 43 to place logs onto burner assembly.
-
Loosen screw and attach a manometer or pressure gauge to the outlet pressure tap of the control valve.
-
Turn on the gas supply. Turn on the electrical supply to the appliance. Check for gas leaks using soap and water solution or leak detection solution. Bubbles indicate a leak that MUST be corrected. Do not use an open flame to test for gas leaks.
-
Check the air shutter opening. See chart and illustration below.
-
Relight the main burners and verify proper burner ignition and operation.
-
With the main burner burning, read the pressure on the manometer or pressure gauge. The pressure on the gauge should read between 9.8″ and 10.2″ w.c.
-
Turn off the gas supply. Turn off the electrical supply to the appliance.
-
Remove the manometer or pressure gauge. Tighten the screw in the pressure tap.
-
Turn on the gas supply. Turn on the electrical supply to the appliance.
-
Immediately test all gas line connections and the control valve for gas leaks using a soap and water solution or other gas detection solution. Bubbles indicate a leak that MUST be corrected. Do not use an open flame to test for gas leaks.
-
Using a ball point pen, fill out the conversion label that is supplied with the conversion kit. Place the conversion label adjacent to the rating plate.
-
Replace glass frame assembly.
-
Reinstall top and bottom louvers.
-
Test operation of fireplace once again. Allow the fireplace to operate for at least 10 minutes and check flame coloration.
Flames on rear of burner should be yellow without any orange-colored tip. Minor adjustment of the air shutter may be necessary to “tune in” the proper flame color.
IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS
5.25 VDC ELECTRONIC CONTROL VALVE
The electronic control valve system includes the ability to switch the pilot
from a standing pilot mode to an intermittent pilot mode.
- IPI Mode – In the Intermittent Pilot mode, when the unit is turned ON, it will cause spark to the pilot, light the pilot, then allow the burner to light. When the unit is turned to OFF, both the burner and pilot will be OFF.
- CPI Mode – In the Continuess Pilot mode, the pilot remains ON continuously even when the burner is turned OFF.
Note: A small toggle switch is located on the front of the module tray
that is used to switch from IPI (left) to the CPI (right). See Figure 72.
When the unit is turned to ON, the electrical current will energize a spark to
the pilot igniter. Once the pilot sensor heats up (after a few seconds), the
valve will be energized, allowing gas to flow to the burner.
- Follow the SAFETY and LIGHTING INSTRUCTIONS for Intermittent Pilot controls found in this manual, and on labels found in the control compartment located in the lower cavity of the appliance.
- During the operating season (or in power outage periods), it is recommended that the pilot remain in the CPI (standing pilot mode) to reduce cold start issues, and/or conserve battery backup power during a power outage.
- The gas valve has inlet and outlet pressure taps as shown in Figure 72. Refer to page 12 for gas pressure requirements. Note: The gas control has a manual HI/LO flame adjustment knob (regulator) that allows you to increase or decrease the height of the burner flame. See Figure 72. Rotate the HI/LO knob counterclockwise to “HI” to increase the flame height, and clockwise to “LO” to decrease the flame height.
OPTIONAL REMOTE CONTROLS
Optional remote controls are available for use with this appliance. It is
recommended that the remote receiver be placed either in a wall outlet box
with extended wiring, on the fireplace hearth, behind the left side surround
panel, or in the control compartment
area as far forward in the insert as possible.
The placement options for the remote receiver are given to allow flexibility,
however battery life will be extended when the receiver is placed in cooler
areas. To connect the remote receiver to the appliance, first disconnect the
ON/OFF switch wires from the white and green wire connectors and connect the
wires from the remote receiver to the green and white wire connectors. See
Figure 72. Follow the instructions included with the remote control for
programming and other operational information.
IPI ELECTRONIC SYSTEM WIRING DIAGRAM
If any of the original wire as supplied with this unit must be replaced, it
must be replaced with equivalent gauge and temperature rated wire.
This appliance is only for use with the type of gas indicated on the rating
plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. This appliance
is not convertible for use with other gases, unless a certified kit is used.
CAUTION: Do not operate the appliance with liner(s) removed, cracked or
broken. Replacement of the liner(s) should be done by a licensed or qualified
service person.
WARNING: Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss of life.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
INTERMITTENT PILOT LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which can be lighted with the manual on/off
switch, a remote control, or by switching the receiver switch to the “ON”
position. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical switch. Do not
use any phone in your building. Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions. If you can not reach
your gas supplier, call the fire department.
C. Use only the remote control or manual remote receiver switch to operate the
gas valve. Never use tools. If valve does not operate, don’t try to repair it,
call a qualified service technician. Force or attempted repair may result in a
fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control which has been
under water.
LIGHTING INSTRUCTIONS
- STOP! Read the safety information above.
- Turn OFF electric power to the appliance.
- Remove front surround panel assembly or bottom louver if included.
- Turn gas cock counterclockwise to “On” position.
- Wait ten minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.
- Turn ON electric power to the appliance.
- Find pilot – Follow metal tube from gas control. The pilot is behind the burner on the right side.
- Turn main flame to on. If the pilot does not light within 60 seconds, stop and go to Step 5.
- Refer to remote control instructions for detailed information, control features, and operation. Note: There is a CPI/IPI switch that allows for a continuous standing pilot mode or an intermittent pilot mode. See appliance manual for location of this switch. If the pilot or burner does not stay lit (in the standing pilot mode), stop and immediately call a qualified service technician or gas supplier.
- If the burner or pilot does not operate properly after several tries, turn the gas cock clockwise to “OFF” and call your service technician or gas supplier.
- Replace the front surround assembly or close bottom louver assembly.
- Operation of the gas valve is controlled by a manual on/ off switch or a hand held remote control. Refer to remote instructions for detailed operation information.
TO TURN OFF GAS TO FIREPLACE
- Turn off all electric power to the appliance if service is to be performed (if applicable).
- Gain access to control compart. Remove surround panel assembly if necessary.
- Locate On/Off gas cock and turn clockwise to “OFF”. Do not force.
- Close bottom louver assembly, if included.
INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING
Brief Description of the Components
The gas valve is fitted with a manual HI/LO knob to allow for manual
modulation of the gas outlet pressure to the appliance burner. The controls
are designed to be used with either LPG or Natural Gas and can be converted by
use of an OEM supplied conversion kit.
The Digital Fireplace Control (DFC) is an automatic gas ignition system based
on a single microcontroller core. This control manages all functions related
to ignition, flame sensing and supervision for atmospheric applications.
The DFC can be set to provide continuous or intermittent ignition control
sequences and flame monitoring with safety shutdown in case of failure.
The DFC is set up as a stand alone (AC powered system with battery back up.
See Lighting Instructions on page 55 and Wiring Diagram on page 54.
Troubleshooting
Before proceeding with the procedures in the following troubleshooting table,
verify that the power supply (AC/DC adapter) is present and that the batteries
inside the receiver and/or optional battery pack are fresh and installed with
correct polarity.
Make sure all the connections between the wire harnesses and system components
are proper and positive.
Verify that the static inlet pressure meets the manufacturer’s recommended
inlet pressure. If necessary adjust the line pressure regulator.
If the recommended actions for the following troubleshooting chart do not help
to address the problem consider replacing wiring harnesses.
WARNING:
Any actions performed on the gas valve must be performed in accordance with
this instruction manual. Likewise, any actions performed on the DFC or other
system components must be done in accordance with the individual
componentinstructions.
Replacement of components must be performed in accordance with this
instructions manual.
RF OPERATING INSTRUCTIONS
RF VALVE OPERATION (AF-4040 Electronic Gas Valve system only)
Please refer to the separate instructions for detailed operation and
programming of the Multi-function Remote Control.
The AF-4040 Electronic Gas Control Valve features a Remote controlled High/Low
Variable – 6 Volt DC Motor Drive. This gas control uses a spark to pilot
burner assembly. For use with Propane or natural gas (pre-set at the factory).
This gas control system includes the items identified in Figure 73.
SPECIAL FEATURES ON THE CONTROL MODULE
The Control Module has two special pilot mode features built into the system.
CONTINUOUS PILOT FEATURE: This allows the user to change from a spark to pilot
system to a standing pilot system.
- There is a switch located on the right side of the Control Module (#4) that reads CONTINUOUS PILOT ON/OFF. This switch will allow the user to select the pilot mode of operation.
- When the continuous pilot switch is in the OFF position and the appliance turned ON, the pilot will spark and light, then the main burner will light as well. When the appliance is turned OFF, the pilot and main burner will shut OFF.
- When the continuous pilot switch is in the ON position and the appliance is turned ON, the pilot will spark and light. Then when the appliance is turned OFF the pilot will remain ON, but the main burner will shut OFF.
Note: The Continuous pilot mode setting is generally recommended on
Direct Vent appliances during cold climate seasons to help keep the firebox
warm.
REMOTE CONTROL FEATURE: The Control Module has a built in remote control
receiver which allows the user to program the hand held remote transmitter.
- There is a switch located on the right side of the Control Mod- ule that reads REMOTE/OFF.
- When the remote/off switch is in the OFF position the appli-ance will operate from an appliance mounted rocker switch (#3) or optional wall switch connected to the two BROWN wires on the Control Module.
- When the remote/off switch is in the REMOTE position the appliance will operate from the Remote Control transmitter.
The Control Module must be programmed to the Remote Control.
-
To program, located the learn button on the left side of the Control Module Note: Press and release the learn button.
There will be a beep sound from the Control Module, then press any key on the remote transmitter. Once the internal receiver accepts the transmitter code there will be a series of confirming beeps. -
To switch between the NG and LP step motor settings, press and hold the learn button for 20 seconds. The module should emit a short beep (less than 1 second) to indicate that the control was switched from NG (default setting) to LP. When switching back from LP to NG, the control should emit a long beep (3 seconds).
POWER SUPPLY SYSTEM
The Gas Control system is powered by a standard 110 volt AC through a 6.0 volt
DC adaptor. The AC adaptor is connected to the Control Module with two 1/4”
female terminals.
This control system also includes a Battery Back-up pack that al-lows the Gas
Control system only to operate in the event of a power outage.
NOTE: The Accent Light and/or Blower features will not operate during a
power outage.
NOTE: All Batteries should be replaced at least once each year,
preferably at the beginning of the heating season.
CAUTION: Fire or explosion hazard. Can cause property damage, sever injury or
death.
Do not attempt to take apart the gas control or to clean it. Improper assembly
and cleaning can cause unreliable operation.
Index No. | Part No. | Description |
---|---|---|
1 | R10418 | Battery Back-up |
2 | R10415 | AF Valve, RF |
3 | R2522 | Off/On Switch |
4 | R11007 | AF Control Module |
5 | R10416 | AF Extension Module |
6 | R10419 | AC Adapter |
7 | R10423 | Pilot Assembly – Nat |
R10424 | Pilot Assembly – LP | |
Not Shown | R11006 | Remote Control, RF |
RF MAINTENANCE INSTRUCTIONS
MAINTENANCE
Maintenance frequency must be determined individually for each application.
Some considerations are:
- Exposure to water, dirt, chemicals and heat can damage the gas control and shut down the control system.
- Cycling frequency. Appliances that may cycle 20,000 times annually should be checked monthly.
- Intermittent use. Appliances that are used seasonally should be checked before shutdown and again before the next use.
- Dusty, wet or corrosive environment. Because these environ- ments can cause the gas control to deteriorate more rapidly, the system should be checked more often.
- Any control should be replaced if it does not perform properly on checkout or service. In addition, replace any module if it is wet or looks like it has been wet.
SERVICE
Do not disassemble the gas control; it contains non-replaceable components.
Attempted disassembly or repair can damage the control.
Exactly follow the warnings and the lighting instructions.
-
Before lighting, smell around the appliance area for gas. If the appliance uses LP (bottled) gas, be sure to smell next to the floor because LP gas is heavier than air. If you smell gas, immediately shut off the manual valve in the gas piping to the appliance or on LP at the tank. Do not try to light any appliance.
Do not touch any electrical switch or use the phone. Leave the building and call your gas supplier.
If your gas supplier cannot be reached, call the fire department. -
The gas control must be replaced if it has been flooded with water. Call a qualified service technician.
-
The gas control is a safety device. It must be replaced in case of any physical damage such as bent terminals, missing parts, stripped threads, or evidence of exposure to excessive heat.
Follow the operating instructions provided by the manufacturer of your heating appliance.
TROUBLESHOOTING
IMPORTANT: All service and trouble-shooting procedures should be
performed by an experienced qualified service technician.
If the pilot will not stay lit:
- Confirm that the “S” wire and the “I” wire are properly con- nected to the Control Module “S” and “I” terminals.
- Confirm that the Spark to Pilot burner is properly grounded to the Gas Control Valve and the Control Module.
- Check the power source from the 6-volt power adaptor or the Battery Back-up pack connection and condition of batteries.
- Check the position of the CONTINUOUS PILOT switch on the Control Module. If main burner does not come ON when the manual switch and remote control is turned ON:
a. Confirm that the pilot sparks and lights.
b. Check the two pin plastic connectors that plug into the face of the Gas Control valve.
c. Confirm that the Gas Control valve is properly grounded to the Control Module.
OPTIONAL GAS CONVERSION KITS
Please contact your dealer or distributor for the proper Conversion kit for
these fireplace models. Conversion kits will include complete instructions,
minimum rate screw, plus the pilot and main burner orifice for the gas type
required. The AF-4040 Electronic
Gas Control Valve is convertible to use either natural or propane gas by
simply turning a small Rotary knob located at the front of the gas valve. This
rotary knob is located under a small rubber cap and should only be adjusted
when converting gas type.
CAUTION: The gas type has been pre-set at the factory and must not be
changed unless a complete conversion is made which includes changing of the
gas pilot injector, minimum rate screw and main burner orifice.
RF WIRING DIAGRAM
NOTE: For “RF” Fireplace models with Premium Multi-Function Remote Control, Refer to the separate instructions for operation of the remote control system.
RF STANDING PILOT LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF
LIFE.
A. This appliance has a pilot which must be lighted with the remote control.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell
next to the floor because some gas in heavier than air and will settle on the
floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch.
- Do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you can not reach your gas supplier, call the fire department.
C. Use only the remote control to operate the gas control knob. Never use
tools. If valve does not operate, don’t try to repair it, call a qualified
service technician. Force or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control which has been
under water.
LIGHTING INSTRUCTIONS
-
STOP! Read the safety information above.
-
Turn OFF electric power to the appliance.
-
Open bottom louver assembly.
-
Turn gas cock counterclockwise to “ON” position.
-
Wait ten minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you do not smell gas, go to the next step.
-
Turn ON electric power to the appliance.
-
Find pilot – Follow metal tube from gas control. The pilot is behind the burner on the right side.
-
Using the remote control, turn main flame to “ON.” If the pilot does not light within 60 seconds, stop and go to Step 5.
-
Refer to remote control instructions for detailed information, control features, and operation. Note: There is a switch on the side of the Electronic Control Module that allows for a continuous standing pilot mode or an intermittent pilot mode. See appliance manual for location of this switch.
If the pilot or burner does not stay lit (in the standing pilot mode), stop and immediately call a qualified service technician or gas supplier. -
If the burner or pilot does not operate properly after several tries, turn the gas control knob clockwise to “OFF” and call your service technician or gas supplier.
-
Close bottom louver assembly.
-
Operation of the gas valve, blower, and/or optional light must be controlled by using the hand held remote control.
Refer to remote instructions for detailed operation information.
TO TURN OFF GAS TO APPLIANCE
- Turn off all electric power to the appliance if service is to be performed (if applicable).
- Open bottom louver assembly.
- Locate On/Off gas cock and turn clockwise to “OFF.” Do not force.
- Close bottom louver assembly.
MAINTENANCE AND SERVICE
Please Note
It is normal for appliances fabricated of steel to give off some expansion
and/or contraction noise during the start up or cool down cycle. Similar
noises are found with your furnace heat exchanger or car engine.
It is not unusual for your gas fireplace to give off some odor the first time
it is burned. This is due to the curing of the paint and any undetected oil
from the manufacturing process.
Please ensure that your room is well ventilated – open all windows.
It is recommended that you burn your fireplace for at least six hours the
first time you use it. If optional fan kit has been installed, place fan in
the “OFF” position during this time.
IMPORTANT: Turn off gas before servicing appliance. It is recommended
that a qualified service person perform these checkups at the beginning of
each heating season.
- Clean Burner and Control Compartment Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
Cleaning Procedure
- Turn off pilot light at gas valve.
- Remove glass front. (See Glass Removal)
- Vacuum burner compartment.
- Reinstall glass front.
- Ignite pilot. (See Lighting Instructions)
- Operate the pilot burner. If it appears abnormal call a service person.
- Check Vent System
The appliance and venting system should be inspected before initial use and at
least annually by a qualified service person.
Inspect the external vent cap on a regular basis to make sure that no debris
is interfering with the air flow.
Reassembly and Resealing Gas Accumulation Relief System Glass Frame Assembly
and Combustion Chamber
Whenever the glass frame assembly is pivoted open by a delayed ignition in the
main burner, the glass frame assembly gaskets and combustion chamber must be
examined by a qualified service person for damage. All damaged gaskets on the
glass frame assembly and combustion chamber must be replaced by a qualified
service person.
If damage occurs to the combustion chamber, it must be replaced by a qualified
service person. Contact Empire Comfort Systems, Inc. for replacement parts.
Glass Cleaning
It will be necessary to clean the glass periodically. During start-up
condensation, which is normal, forms on the inside of the glass and causes
lint, dust and other airborne particles to cling to the glass surface. Also
initial paint curing may deposit a slight film on the glass. It is therefore
recommended that the glass be cleaned two or three times with a non-abrasive
household cleaner and warm water (we recommend gas fireplace glass cleaner).
After that the glass should be cleaned two or three times during each heating
season depending on the circumstances present.
General Glass Information
WARNING: Do not operate appliance with the glass front removed, cracked or
broken. Replacement of the glass should be done by a licensed or qualified
service person.
Only glass approved for use by the manufacturer in fireplace may be used for
replacement. The glass replacement should be done by a licensed or qualified
service person.
WARNING:
-
The use of substitute glass will void all product warranties.
-
Care must be taken to avoid breakage of the glass.
-
Under no circumstances should this appliance be operated without the glass front or with a broken glass front.
Replacement of the glass (with gasket) as supplied by the manufacturer should be done by a qualified service person. -
Do not abuse the glass by striking or hitting the glass.
WARNING: Do not use abrasive cleaners on glass. Do not attempt to clean
glass when glass is hot.
Glass Door Removal
- Remove the top louver by grasping the louver, then lift upward and pull forward.
- Remove the bottom louver by lifting up and pulling forward.
- Locate the bottom two glass frame spring clamps. Pull forward and down to release them from the Glass Door frame.
- Remove the Glass Door by pulling the bottom of the door outward several inches, then lift upwards to disengage it from the firebox upper flange.
Glass Door Installation
-
When installing the Glass Door assembly, make sure that the door top flange is hooked over the firebox top flange as illustrated in the “Correct” view in Figure 71.
Important: Do not allow the gasket across the top of the door to roll up on top of the firebox flange as shown in “Incorrect” view in Figure 71. -
To install correctly, the door should be held at an angle outward from the firebox as shown in the illustration, then carefully engage the upper flange of the door frame with the top flange of the firebox. Center the door left to right, then allow the bottom of the door to swing inward to seal against the firebox front.
-
Once the glass door is placed flat to the firebox front edges, engage the two spring latches to the bottom flange on the glass door frame to secure the door assembly.
-
Replace the top and bottom louvers.
Louver Removal and Installation
- Remove top louver, grasp louver and pull forward.
- Lower bottom louver.
- Align clips on top louver with slots on front posts. Replace top louver into fireplace.
- Close bottom louver.
PARTS LIST
INDEX NO. | PART NUMBER | DESCRIPTION |
---|---|---|
DVP36FP3 | DVP36FP5 | DVP36FP7 |
1 | R7654 | R7654 |
2 | 17425 | 17425 |
3 | R7566 | R7566 |
4 | R7573 | R7573 |
5 | 17155 | 17155 |
6 | M163 | M163 |
7 | 17142 | 17142 |
8 | R7575 | R7575 |
9 | 17141 | 17141 |
10 | R7574 | R7574 |
11 | 17149 | 17149 |
12 | 10554 | 10554 |
13 | 17162 | 17162 |
14 | R3492 | R3492 |
15 | 17357 | 17357 |
16 | 17445 | 17445 |
17 | 18806 | 18806 |
18 | 23343 | 23343 |
19 | 18807 | 18807 |
20 | 18809 | 18809 |
21 | 18808 | 18808 |
22 | R7611 | – |
22 | R7612 | – |
23 | R7617 | R7617 |
24 | 11269 | 11269 |
25 | R7649 | R7649 |
26 | P200 | P200 |
27 | P258 | P258 |
27 | P256 | P256 |
28 | R5676 | R5676 |
29 | 11499 | 11499 |
30 | 11377 | 11377 |
31 | 17370 | 17370 |
32 | 21533 | 26632 |
33 | 18801 | 17369 |
34 | R2423 | R2423 |
35 | – | – |
36 | R7578 | R7733 |
R10428 | Gas Valve (LPG) | |
36 | R7577 | R7733 |
R10430 | Gas Valve (Nat) | |
37 | 17161 | 20207 |
38 | 16223 | 16223 |
*NOTE: For fireplace with serial #1634000000 and earlier. Also order
26307 valve bracket.
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE
INJURY OR DEATH.
INDEX
NO.| PART NUMBER| DESCRIPTION
---|---|---
DVP36FP3| DVP36FP5| DVP36FP7| DVP36FP9
39| R10947| R8147| R11123| –| Wire Assembly
40| R2708| –| –| –| Piezo Ignitor
41| R3436| –| –| –| Remote/On/Off Switch
42| –| –| 29382| –| Tray Control Module
43| –| R7615| –| –| Cord Set
44| –| R8144| –| –| Wire Harness
45| –| –| R2667| –| Wire Harness
46| –| –| –| 18880| Blower Shield
47| –| –| –| 18858| Blower Base
48| FBB4| FBB4| FBB4| R7731| Blower Assembly
49| –| –| –| R7831| Blower Wire Assembly
50| R10352| R10352| R10352| R10352| Twig, Top Branch
51| R10350| R10350| R10350| R10350| Log, Front Left
52| R10351| R10351| R10351| R10351| Log, Front Right
53| R10349| R10349| R10349| R10349| Log, Rear
54| –| –| R11122| R10418| Battery Back-up
55| –| –| R11128| R10419| AC Adapter
56| –| –| –| R10416| 120V Extension Module
57| –| R7616| R11127| R11007| Control Module
58| –| –| –| R10499| Extension Wire Harness (5 pin)
59| –| –| –| R10497| Wire Harness (4 Pin )
60| –| –| –| R10498| Wire Harness (8 Pin)
61| | Not Used On DVP36FP(3,5,7,9) Models| | Insulation, Top Shield
62| | Not Used On DVP36FP(3,5,7,9) Models| | Heat Shield, (Flue)
63| | Not Used On DVP36FP(3,5,7,9) Models| | Mounting Brace
64| R8598| R8598| R8598| R8598| Optional Brick Panel, Side (Left)
65| R8602| R8602| R8602| R8602| Optional Brick Panel, Back
66| R8598| R8598| R8598| R8598| Optional Brick Panel, Side (Rt)
67| R8606| R8606| R8606| R8606| Optional Brick Panel, Top
68| –| R7613| –| –| Ignitor Wire
69| –| R7590| –| –| Spark Ignitor, PSE
70| –| R7589| –| –| Gasket, PSE Ignitor
71| –| 19545| –| –| Spark Ignitor Shield
72| –| –| R2522| –| On/Off Switch
73| –| –| 31500| 31500| Pilot Shield
74| –| –| R11034| –| Wire Adapter
N/S| –| –| –| R10428 (# 52)| Min. Rate Screw (LPG)
N/S| –| –| –| R10430 (# 37)| Min. Rate Screw (NAT)
N/S| R5668| | –| –| Ignitor Wire, Piezo
N/S| –| –| –| R11006| Remote Control, RF
N/S| 18704| 18704| 18704| 18704| Decorative Rock (1 lb)
N/S| 15999| 15999| 15999| 15999| Rockwool (0.1 oz)
N/S – Not Shown
See page 43 for log part numbers.
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE
INJURY OR DEATH.
PARTS VIEW
MASTER PARTS DISTRIBUTOR LIST
To Order Parts Under Warranty, please contact your local Empire dealer. See
the dealer locator at www.empirecomfort.com.
To provide warranty service, your dealer will need your name and address,
purchase date and serial number, and the nature of the problem with the unit.
To Order Parts After the Warranty Period, please contact your dealer or one of
the Master Parts Distributors listed below.
This list changes from time to time. For the current list, please click on the
Master Parts button at www.empirecomfort.com.
Please note: Master Parts Distributors are independent businesses that
stock the most commonly ordered Original Equipment repair parts for Heaters,
Grills, and Fireplaces manufactured by Empire Comfort Systems Inc.
Dey Distributing
1401 Willow Lake Boulevard
Vadnais Heights, MN 55101
Phone: 651-490-9191
Toll Free: 800-397-1339
Website: www.deydistributing.com
Parts: Heater, Hearth and Grills| F. W. Webb Company
200 Locust Street
Hartford, CT 06114
Phone: 860-722-2433
Toll Free: 800-243-9360
Fax: 860-293-0479
Toll Free Fax: 800-274-2004
Websites: www.fwwebb.com &
www.victormfg.com
Parts: Heater, Hearth and Grills| East Coast Energy Products
10 East Route 36
West Long Branch, NJ 07764
Phone: 732-870-8809
Toll Free: 800-755-8809
Fax: 732-870-8811
Website: www.eastcoastenergy.com
Parts: Heater, Hearth and Grills
---|---|---
HOW TO ORDER REPAIR PARTS
Parts Not Under Warranty
Parts can be ordered through your Service Person, Dealer, or a Master Parts
Distributor. See this page for the Master Parts Distribu-tors list. For best
results, the service person or dealer should order parts through the
distributor. Parts can be shipped directly to the service person/dealer.
Warranty Parts
Warranty parts will need a proof of purchase and can be ordered by your
Service Person or Dealer. Proof of purchase is required for warranty parts.
All parts listed in the Parts List have a Part Number. When ordering parts,
first obtain the Model Number and Serial Number from the name plate on your
equipment. Then determine the Part Number (not the Index Number) and the
Description of each part from the following illustration and part list. Be
sure to give all this information . . .
Appliance Model Number …………………..
Part Description…………………………
Appliance Serial Number……………….
Part Number…………………..
Type of Gas (Propane or Natural)………………..
Do not order bolts, screws, washers or nuts. They are standard hardware items
and can be purchased at any local hardware store.
Shipments contingent upon strikes, fires and all causes beyond our control.
FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION
Attention : Install blower assembly before connecting gas inlet supply
line
NOTE: Junction box on right side of fireplace must be pre-wired at time
of fireplace installation for use ith blower assembly. It is recommended that
an ON/OFF wall switch be installed that will activate the power supply to the
furnace by a qualified electrician.
-
If installed, turn OFF gas supply to fireplace.
-
If applicable, turn OFF electric supply to fireplace.
-
Lower bottom louver on fireplace.
-
Refer to page 70, “Junction Box Wiring Installation Instructions” to complete wiring of junction box.
Attention: If installed, do not damage gas inlet supply line when blower assembly is inserted into fireplace.If necessary, remove gas inlet supply line. -
Insert blower assembly into interior, bottom of fireplace.
Position blower assembly behind gas valve, align notch on back of blower assembly with center screw on fireplace back and push blower assembly against fireplace back. The magnets on the back and bottom of blower assembly will sufficiently hold blower assembly in place. -
Position speed control box to the right of gas valve.
Attach speed control box to bottom of fireplace. The magnets on bottom of speed control box will sufficiently hold speed control box in place. -
With base (flush face) of fan control switch facing upward, insert base of fan control switch under the mounting tabs on valve bracket. The base (flush face) of fan control switch must be in contact with bottom of firebox.
-
Insert power cord plug into junction box.
-
Close bottom louver on fireplace.
-
Installation of FBB4 optional variable speed blower assembly is completed.
Wiring
The appliance, when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized.
This appliance is equipped with a three-prong [grounding] plug for your
protection against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding prong from
this plug. For an ungrounded receptacle, an adapter, which has two prongs and
a wire for grounding, can be purchased, plugged into the ungrounded receptacle
and its wire connected to the receptacle mounting screw. With this wire
completing the ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.
Blower Motor
The blower motor does not have oiling holes. Do not attempt to oil the blower
motor.
Blower Wheels
The blower wheels will collect lint and could require periodic cleaning. If
the air output decreases or the noise level increases, it indicates a dirty
blower wheel. Remove fan and clean blower wheels.
WARNING: : Unplugging of blower accessory will not stop the heater from
cycling. To turn off gas to the heater (millivolt model): push in gas control
knob slightly and turn clockwise to “OFF.” Do not force. To turn off gas on
direct ignition model, turn gas line valve to *“OFF.” Note:** Refer to
Junction Box wiring instructions on page 70 for proper operation.
1 | R7731 | BLOWER MOTOR |
---|---|---|
2 | 31920 | SWITCH ASSEMBLY |
3 | R4192 | SPEED CONTROL KNOB |
4 | R4186 | SPEED CONTROL |
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE
IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE
ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE
APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH
LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL
CODE ANSI/NFPA 70 (LATEST EDITION).
A factory installed junction box is located on the lower right side of the
fireplace. Wiring must be fed to the junction box and attached to the
receptacle that is provided. Leave approximately 6″ of wire in the junction
box for connection.
Attach black wire to one side of the receptacle and white wire to opposite
side of receptacle. The ground wire should be attached to the green (ground)
screw.
Install the receptacle into the junction box. Attach cover plate.
Attention: A Junction box is located on the lower left side of the
fireplace for direct ignition connections on direct ignition fireplace models
only.
OPTIONAL BRICK LINER INSTALLATION INSTRUCTIONS
-
Using gloves, unpack liner components and check for damaged or missing components.
-
Lower bottom louver and remove upper louver on fireplace.
-
Remove glass frame assembly from fireplace.
-
Remove rear logs from burner assembly.
-
Place brick panel (rear) against rear wall in fireplace.
Note: The top edge will have a half-moon cutout relief to match up with the rear flue vent hole. -
While holding finished edge on brick panel (side), place brick panel (sides) against side walls in fireplace. Move side panels rearward until the back edge meets the rear brick panel. Slide side brick panels down so they rest on firebox bottom.
-
Align grout lines on top brick panel with the grout lines on the side brick panels. Place the top brick panel into brick panel holder. With needle-nose pliers, carefully bend hold-down tabs on brick panel holder over the edges of the top brick panel. The hold-down tabs will securely hold the top brick panel in place.
-
Replace rear logs onto burner assembly. Refer to log placement, page 43.
-
Attach glass frame assembly onto fireplace.
-
Raise bottom louver and replace top louver onto fireplace.
-
Installation of optional brick liner is complete.
ACCESSORIES
The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220-2623.
Accessory | Description | Model Number |
---|---|---|
This fan kit was designed to provide forced air flow. |
(Note: For use with Millivolt and intermittent pilot
models only. “RF” Fireplace models are equipped
with blower assembly.)| Variable Speed FBB4
| The simulated brick panels were designed to enhancethe appearance of your
fireplace, imitating the look
of authentic masonry.
HERRINGBONE| DVP36D2H
| The simulated brick panels were designed to enhance
the appearance of your fireplace, imitating the look
of authentic masonry.
AGED BRICK| DVP36D2A
DECORATIVE ACCESSORIES
Empire Comfort Systems
918 Freeburg Avenue
Belleville, Illinois 62220-2623
Web Site www.empirecomfort.com
The Tahoe Direct Vent Zero Clearance Gas Fireplace Heater
MILLIVOLT STANDING PILOT: DVP36FP3(0,1,2,3)-5 (NAT, LP)
DIRECT IGNITION: DVP36FP(5(0,1,2,3)-1 (NAT)
INTERMITTENT PILOT: DVP36FP7(0,1,2,3)-6 (NAT, LP)
REMOTE RF: DVP36FP9(1,3)-6 (NAT, LP)
Fireplace requires one of the following fronts:
Arched: DCF42B(FB,CM,HP), DCF42T(FB,CM,HP)
Rectangular: DCF42A(FB,CM,HP)
Fireplace requires one of the following ceramic liners:
DVP3DA, DVP3DH, DVP42DG
All Brick Liners are made from Ceramic Fiber for rich detail and lasting
beauty. Aged Brick Liners have brown bricks with charcoal mortar in running
bond courses, plus smoked accents.
Herringbone Liners have burnt umber bricks in a herringbone pattern with light
mortar, plus smoked accents. Stacked Limestone Liners have stones of varying
depth and color for a rustic cabin look.
CLEARANCES TO COMBUSTIBLES
Clearance to Combustibles
Back| 0″ (0 mm)
Side| 0″ (0 mm)
Floor| 0″ (0 mm)
Top Stand-off| 0″ (0 mm)
Top Framing Edge| 3″ (76 mm)
Empire Comfort Systems
918 Freeburg Avenue
Belleville, Illinois 62220-2623
Web Site www.empirecomfort.com
The Tahoe Direct Vent Zero Clearance Gas Fireplace Heater
MILLIVOLT STANDING PILOT: DVP36FP3(0,1,2,3)-5 (NAT, LP)
DIRECT IGNITION: DVP36FP(5(0,1,2,3)-1 (NAT)
INTERMITTENT PILOT: DVP36FP7(0,1,2,3)-6 (NAT, LP)
REMOTE RF: DVP36FP9(1,3)-6 (NAT, LP)
Fireplace requires one of the following fronts:
Arched: DCF42B(FB,CM,HP), DCF42T(FB,CM,HP)
Rectangular: DCF42A(FB,CM,HP)
Fireplace requires one of the following ceramic liners:
DVP3DA, DVP3DH, DVP42DG
All Brick Liners are made from Ceramic Fiber for rich detail and lasting
beauty. Aged Brick Liners have brown bricks with charcoal mortar in running
bond courses, plus smoked accents.
Herringbone Liners have burnt umber bricks in a herringbone pattern with light
mortar, plus smoked accents. Stacked Limestone Liners have stones of varying
depth and color for a rustic cabin look.
FIREBOX DIMENSIONS
A | DIMENSION |
---|---|
B | 39″ (99.1 cm) |
C | 36″ (91.4 cm) |
D | 25 1/16″ (63.7 cm) |
E | 37 5/8″ (96 cm) |
F | 34 3/4″ (88 cm) |
G | 19 7/8″ (50.5 cm) |
H | 26 1/2″ (66 cm) |
I | 7 1/8″ (18.1 cm) |
J | 27″ (68.6 cm) |
K | 13 1/2″ (34.6 cm) |
L | 12 3/4″ (32.4cm) |
FRAMING DIMENSION
| DVP36
---|---
“A”| 37 3/4″ (962 mm)
“B”| 39 3/8” (1000 mm)
“C”| 19 7/8″ (505 mm)
WARRANTY
Empire Comfort Systems Inc. warranties this hearth product to be free from
defects at the time of purchase and for the periods specified below. Hearth
products must be installed by a qualified technician and must be maintained
and operated safely, in accordance with the instructions in the owner’s
manual. This warranty applies to the original purchaser only and is not
transferable. All warranty repairs must be accomplished by a qualified gas
appliance technician.
Limited Lifetime Parts Warranty – Combustion Chamber, Heat Exchanger, and
Factory-Installed Glass
If the combustion chamber, heat exchanger (see parts list) or factory-
installed glass fails because of defective workmanship or material, Empire
will repair or replace at Empire’s option.
Limited Three-Year Parts Warranty – All Other Components
(Except Remote Controls, Thermostats, Accessories and Replacement Parts)
Should any part fail because of defective workmanship or material within three
years from the date of purchase, Empire will repair or replace at Empire’s
option..
Limited One-Year Parts Warranty – Remote Controls, Thermostats,
Accessories, and Parts
Should any remote control, thermostat, accessory, or other part fail because
of defective workmanship within one year from the date of purchase, Empire
will repair or replace at Empire’s option.
Duties Of The Owner
The appliance must be installed by a qualified installer and operated in
accordance with the instructions furnished with the appliance. A bill of sale,
cancelled check, or payment record should be kept to verify purchase date and
establish warranty period. Ready access to the appliance for service.
What Is Not Covered
Damages that might result from the use, misuse, or improper installation of
this appliance.
Travel, diagnostic costs and freight charges on warranted parts to and from
the factory.
Claims that do not involve defective workmanship or materials.
Unauthorized service or parts replacements.
Removal and reinstallation cost.
Inoperable due to improper or lack of maintenance.
How To Get Service
To make a claim under this warranty, please have your receipt available and
contact your installing dealer. Provide the dealer with the model number,
serial number, type of gas, and purchase verification. The installing dealer
is responsible for providing service and will contact the factory to initiate
any warranted parts replacements. Empire will make replacement parts available
at the factory. Shipping expenses are not covered.
If, after contacting your Empire dealer, service received has not been
satisfactory, contact: Consumer Relations Department, Empire Comfort Systems
Inc., PO Box 529, Belleville, Illinois 62222, or send an e-mail to
info@empirecomfort.com with “Consumer
Relations” in the subject line.
Your Rights Under State Law
This warranty gives your specific legal rights, and you may also have other
rights, which vary from state to state.
APPLIANCE SERVICE HISTORY
Date | Dealer Name | Service Technician Name | Service Performed/Notes |
---|---|---|---|
Empire Comfort Systems Inc.
Belleville, IL
If you have a general question
about our products, please e-mail
us at info@empirecomfort.com.
If you have a service or repair
question, please contact your dealer.
www.empirecomfort.com