PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual

May 15, 2024
PETSITE

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual

Note: All the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly different.
The actual shape shall prevail. They are subject to change without notice for future improvement.

Safety Precautions

Incorrect installation or operation by not following these instructions may cause harm or damage to people, properties, etc.
The seriousness is classified by the following indications:

⚠ WARNING
This symbol indicates the possibility of death or serious injury.

⚠ WARNING
This symbol indicates the possibility of injury or damage to properties.

⚠ WARNING
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
(Only for the AC with CE-MARKING)

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
(Except for the AC with CE-MARKING)

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - Safety
precautions

This product contains fluorinated greenhouse gases.
Refrigerant leakage contributes to climate change.
Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [2088]. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [2088] times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional .
The specification of the fuse are printed on the circuit board, such as: 3.15A/250V AC, etc.

WEEE Warning
Meaning of crossed out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact you local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - Safety
precautions PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - Safety
precautions

Notices for usage

The conditions of unit can’ t normally run

  • Within the temperature range provided in following table, the air conditioner may stop running and other anomalies may arise.

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - Notices
for usage

  • When the temperature is too high, the air conditioner may activate the automatic protection device, so that the air conditioner could be shut down.
  • When the temperature is too low, the heat exchanger of the air conditioner may freeze, leading to water leakage or other malfunction.
  • In long-term cooling or dehumidification with a relative humidity of above 80% (doors and windows are open), there may be water condenses or dripping near the air outlet.
  • T1 and T3 refer to ISO 5151.

Notes for heating

  • The fan of the indoor unit will not work immediately when the heating is started to avoid blowing out cool air.
  • When it is cold and wet outside, the outdoor unit will develop frost over the heat exchanger which will compromise the heating capacity. This is when the air conditioner will start defrost.
  • During defrost, the air conditioner will stop heating for about 5-12 minutes.
  • Vapor may come out from the outdoor unit during defrost. This is not a malfunction, but a result of fast defrost.
  • Heating will resume after defrost is complete.

Notes for turning off

  • When the air conditioner is turned off, the main controller will automatically decide whether to stop immediately or after running for dozens of seconds with lower frequency and lower air speed.

Emergency operation

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - Emergency
operation

  • If the remote controller is lost or broken, use force switch button to operate the air conditioner.
  • If this button is pushed with the unit OFF, the air conditioner will operate in Auto mode.
  • If this button is pushed with the unit ON, the air conditioner will stop running.

Airflow direction adjustment

  1. Use up-down swing and left-right swing buttons on the remote controller to adjust the airflow direction. Refer to the operation manual of the remote controller for detail.
  2. For models without left-right swing function, the air vent has to be moved manually.

Note: Move the air vents before the unit is in operation, or your finger might be injured.
Never place your hand into the air inlet or outlet when the air conditioner is in operation.

ATTENTION

If the equipment emissions cannot meet the technical requirement of IEC 61000-3-3, following attention should be
Attention: This appliance can be connected only to a supply with system impedance no more than Zmax. necessary, please consult your supply authority for system impedance information. _

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - This
appliance can be connected

Names of each art

Indoor unit

There are two kinds about Indoor unit, Fig A ,Fig B, the actual shape shall prevail.

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - Indoor
unit

Outdoor unit

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - Outdoor
unit

Note: All the illustrations in this manual are for explanation purpose only.
Your air conditioner may be slightly different. The actual shape shall prevail.
They are subject to change without notice for future improvement.
Plug, WIFI function, Negative-ion function, and Vertical and horizontal swing function both are optional, the actual unit shall prevail.

Clean and care

⚠ WARNING

  • Before the cleaning of the air conditioner, it must be shut down and the electricity must be cut off for more than 5 minutes, otherwise there might be the risk of electric shock.
  • Do not wet the air conditioner, which can cause an electric shock. Make sure not to rinse the air conditioner with water under any circumstances.
  • Volatile liquids such as thinner or gasoline will damage the air conditioner housing, therefore please clean the housing of air conditioner only with soft dry cloth and damp cloth moistened with neutral detergent.
  • In the course of the usage, pay attention to cleaning the filter regularly, to prevent the accumulation of dust which may affect the air conditioner performance. If the service environment of the air conditioner is dusty, correspondingly increase the number of times of cleaning. After removing the filter, do not touch the fin part of the indoor unit with the finger, so as to avoid scratching it.

Clean the panel

When the panel of the indoor unit is contaminated, clean it gently with a wrung towel using tepid water below and do not remove the panel while cleaning.

Clean the air filter

■ Remove the air filter

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - Clean the
air filter

Clean the air filter
■ Mount the Filter

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual - Mount the
Filter

Check before using

  1. Check whether all the air inlets and outlets of the units are unblocked.
  2. Check whether there is blocking in the water outlet of the drain pipe, and immediately clean it up if any.
  3. Check the ground wire is reliably grounded.
  4. Check whether the remote control batteries are installed, and whether the power is sufficient.
  5. Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our service.

Maintain after using

  1. Cut off the power source of the air conditioner, turn off the circuit breaker and remove the batteries from the remote control.
  2. Clean the filter and the unit body.
  3. Remove the dust and debris from the outdoor unit.
  4. Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our I service.

Troubleshooting

⚠ CAUTION

  • Do not repair the air conditioner by yourself as wrong maintenance may cause electric shock or fire, please contact the authorized service center and let the professionals conduct the maintenance, and check the following items prior to contacting for maintenance can save your time and money.

PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual -
Troubleshooting PETSITE 12000 BTU Mini Split Air Conditioner Instruction Manual -
Troubleshooting

⚠ Immediately stop all operations and cut off the power supply , contact our Service center in following situations.

⚠ Shrill sound is heard or Unpleasant odor is emitted during the operation .
⚠ There is an abnormal heat in power supply cord and power plug .
⚠  Accidentally pour impurities or water into the machine or the remote control.
⚠ Air switch or protection switch often breaks.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PETSITE User Manuals

Related Manuals