FRANKE Misc Maris Water Hub User Manual

August 22, 2024
Franke

FRANKE Misc Maris Water Hub

Product Information

Specifications:

  • System: 3-in-1 electronic boiling water system
  • Tap: Active boiling J-spout
  • Box: Hydraulic
  • Filter: Cartridge

Product Usage Instructions

Installation:
Follow the general starting points and installation steps provided in the manual for proper setup of the Maris Water Hub.

Operation:
For operating the boiler, follow the instructions detailed in the manual. The boiler can be decommissioned and taken out of service as needed.
To switch on the device for the first time, refer to the specific guidelines outlined in the manual. Tap operation instructions are also provided.
Utilize the mixer lever and electronic knob as instructed. The filling mode functionality is explained for your convenience.

Filter Operation and Replacement:
Learn how to operate the filter and replace it when necessary.
Make sure to select the appropriate neutral LED intensity setting.

Maintenance:
Regular maintenance is essential for optimal performance. Follow the general maintenance procedures provided in the manual. This includes replacing the filter and descaling the tap aerator.

FAQ (Frequently Asked Questions)

  1. Q: Can children operate the product?
    A: This product can be operated by children under 12 years old or persons with reduced capacities under supervision or after proper instructions.

  2. Q: What should I do if the power lead is damaged?
    A: If the power lead is damaged, it should be replaced by the manufacturer, customer service, or a qualified person to prevent electric shock.

Support and Warranty page

About this manual
This manual contains important information on the safe and proper installation and commissioning of the product.
FRANKE reserves the right to make modifications to the product without prior notice. All information correct at time of issuance.

  • Carefully read the user manual before using the device.
  • Keep the user manual.
  • Use the device described in this user manual only according to the intended use.

Safety information

General

  • Install the product as described in this manual and in accordance with the applicable installation, safety and local water supply regulations!
  • Do not use the product for purposes other than those for which it is intended as described in this manual.
  • The product must not be modified.
  • Only insert the plug into a grounded wall socket.
  • This tap may be operated by children under the age of 12 and by persons with reduced physical, sensory or mental capacities, or who lack the necessary experience or knowledge, only under supervision or after being instructed in the safe use of the product and when they are aware of the hazards that may arise from the use of the product and/or system.
  • Cleaning and maintenance by the user must not be performed by children or by persons with reduced physical, sensory or mental capacities, or who lack the necessary experience or knowledge, without supervision.
  • Prevent children from playing with the product and/or system.
  • This product and or system is intended for use in domestic and similar environments, such as:
    • Staff kitchens in stores, offices and other working environments;
    • By guests in hotels, motels and other similar residential environments;
    • Bed and breakfast accommodation and other similar residential environments.
  • Use in other environments in consultation with the manufacturer of the product and/or system.
  • If the power lead with plug is damaged, it must be replaced by the manufacturer, the manufacturer’s customer service or a qualified person in order to avoid electric shock.
  • If necessary, lubricate O-rings only with silicone grease.
  • In order to avoid freezing, the product may only be installed in frost-free rooms.
  • Safety instructions must be observed in order to avoid physical injury and/or damage to the product and/or system.
  • Maintenance instructions must be observed in order to avoid damage and excessive wear.
  • As a result of the ongoing improvement of our products and/or systems, illustrations in this document may differ from the appliance as delivered.
  • If available, you can download the latest version of the manual via our website: www.franke.com
  • Franke cannot be held responsible for costs, damage or personal injury if the product is not operated in accordance with the instructions given in this manual.
  • Tap and boiler model may differ from the model illustrated in the manual.

Tap

  • Avoid burns and scalding and pay attention when using hot water. The temperature of the hot water may be higher than 55°C.
  • Avoid burns and scalding and pay attention when using boiling water. The temperature of the water may be higher than 100°C.
  • Tiled and stone sinks will not withstand boiling water; the difference in temperature can cause these to crack. Always open the cold water tap when pouring out boiling water and preferably pour the boiling water directly into the drain.

Boiler

  • Before commissioning, ensure that the boiler is filled with water.
  • Never pick up or carry the boiler with the hoses or the mains lead.
  • The appliance must be connected always with the cold water supply.
  • Before installation of the boiler make sure the pressure relieve valve outlet is 8 cm above the connection of the waste pipe.
  • The drain hose must be connected with a continuous downwards gradient and a siphon must be made, therefore please note you may need to cut the drain hose.

Filter cartridge

  • The use of a Franke filter is mandatory to protect the product against lime scale deposits. It is mandatory to change the filter based on the water hardness table.
  • After storage at a temperature of 0°C, the filter must first be stored for 24 hours at room temperature before it is installed.
  • The filter cartridge must not be opened or damaged.
  • The filter cartridge and the system must be intensively flushed after a prolonged standstill period and/or during maintenance work (2 liters of flushing water after 1 week standstill; 10 liters of flushing water after 4 weeks’ standstill).
  • The filter cartridge must be replaced if, after commissioning, it has not been in operation for 3 months.

Warranty
Scan the QR code to reach the Warranty guidelines: 


Installation instructions

Caution: Never use serrated tools in order to avoid damage. Where necessary, always use the appropriate tools for tightening the coupling.

  • Minimum bending radius after installation.
  • Without bends after installation.
  • Without bend immediately after connection.
  • Without tension after installation.
  • Without torsion after installation.

Product information
System

  • Water supply pressure (min.) 100 kPa/14.5 psi/1 bar
  • Water supply pressure (max.) 500 kPa/72.5 psi/5 bar
  • Flow rate boiling water 2 – 4 l/min * 2.5 bar
  • Flow rate cold water 5 – 9 l/min *
  • Flow rate hot water 5 – 9 l/min *
    • The flow rate varies, depending on the water supply pressure and the type of tap.

Water quality requirements

  • pH value 7 – 9.5

Tap Active boiling 3-in-1 electronic J-spout
Check the details in the “Installation and user manual” part 2, page 5.

Hydraulic box
Check the details in the “Installation and user manual“ part 2, page 5.

Filter
Check the details in the “Installation and user manual“ part 2, page 5.

  • Filter type Franke Pro M
  • Diameter 95 mm
  • Height incl. Filter head 295 mm
  • Filter head Bayonet / Separate part

Filter disposal residual waste

  • Decarbonization Yes
  • Odors Yes
  • Chlorine Yes
  • Particle Yes
  • Microplastics Yes
  • The use of a Franke filter is mandatory to protect the product against lime scale deposits. It is mandatory to change the filter based on the water hardness table.
    Failure to replace your filter will invalidate your warranty.

Boiler
Check the details in the “Installation and user manual“ part 2, page 6.
Warning: Only vertical installation of the boiler is possible (on/off knob on the bottom).

Boiler 4 liters 7 litres
Dimensions [H x W] 340 x 229 mm 494 x 229 mm
Net weight 4.5 kg 5.5 kg
Contents 4 l 7 l
Voltage 230 VAC 230 VAC
Power 2100 W (+5%/-10%) 2100 W (+5%/-10%)
Load 9.2 A 9.2 A
Standby mode max. 14 W 14 W
IP classification IPX4 IPX4
Storage temperature <105°C <105°C
Heating time [ΔT 100 K] 15 min 24 min
Operating pressure (max.) 800 kPa / 116 psi / 8 bar 800 kPa / 116 psi / 8

bar
Operating temperature:| 0-40°C| 0-40°C
Power supply EU:| Type E+F CEE 7/7 Schuko| Type E+F CEE 7/7 Schuko
Power supply UK:| Type G/ BS 1363 British 3 Pins| Type G/ BS 1363 British 3 Pins
Declared load profile and typical usage| XXS| XXS
Water heating energy efficiency class| A| A
Water heating energy efficiency| 35.15 %| 35.50 %
Annual electricity consumption| 523 kWh| 520 kWh
Thermostat temperature setting| 103°C| 103°C

Installation

General starting points for installation
Perform the following steps before starting installation.

  1. Stop valves must already be installed.
  2. If the water pressure is above the 5 bar, use a pressure reducing valve (3 bar).
  3. Close the stop valves.
  4. In existing installations, remove the tap, hoses and boiler if still in place.
  5. Mark the existing cold and hot water connection.
  6. There must be two wall plug sockets available for connection.

Install the pressure relief valve as high as possible in the kitchen cabinet.

Installation steps
Check the details in the “Installation and user manual“ part 2, page 3-17.

  1. Installing 3-in-1 tap (see page 7)
  2. Installing filter (see page 8)
  3. Installing pressure relief valve (see page 8)
  4. Connecting drain hose (see page 9)
  5. Installing boiler (see page 9)
  6. Installing Hydraulic Box (see page 10)
  7. Connecting Hydraulic Box (see page 10)
  8. Connecting tap (see page 11)
  9. Activating Hydraulic Box (see page 12)
  10. Flushing boiler (see page 12)
  11. Activating boiler (see page 12)
  12. Installing with WWS (see pages 13 and 14)
  13. Installing with Bypass (see pages 15 and 16)
  14. Commissioning (see page 12)

Operation

Operation of boiler

  • Briefly pressing the ON/STANDBY button switches between the boiler modes ON and STANDBY.

ON:

  • The LED is continousily red.

OFF:

  • The LED is off.

When the boiler has been switched of for a week, we recommend that the following procedure is observed before use:

  • Switch on boiler. Wait until the boiler water is up to temperature.
  • Open the boiling water tap and flush the boiling water line until cold water comes out of the tap.

Caution: Ensure that the water does not atomise during flushing.

  • Heat the boiler water again.

Decommissioning boiler

  1. Remove the plug of the boiler from the wall plug socket.
  2. Start the water flow on the electronic knob.
  3. Wait until cold water runs out.
  4. Stop the water flow on the electronic knob.
  5. Close the stop valve.
  6. Start the water flow on the electronic knob.
  7. Wait until water no longer runs out.
  8. Stop the water flow on the electronic knob.
  9. Disconnect the hoses from the boiler.
  10. Remove the boiler.
  11. Allow the water from the hoses and the boiler to drain into the sink.

Taking boiler out of service
If you do not expect to need any boiling water for a prolonged period, such as during holidays, you can switch off the boiler (temporarily):

  • Use the boiler STANDBY mode, or remove the plug from the wall plug socket to prevent heating of the boiler.

Switching on for the first time

Ensure that the boiler is filled with water!

Boiler

  1. Operate the mixer tap and flush with warm water for 1 minute (fig. 1).

  2. Activate the electronic knob and select the boiling water (red LED) (fig. 2). Press the electronic knob 3 times. Repeat this step twice to ensure the boiler is flushed and full of water. The system will be flushed. It is normal that at the beginning of the flushing mode air comes out. When there is a smooth laminar flow out of the tap, the system is properly flushed.

  3. Switch on the boiler.

  4. Inspect the installation for leaks after commissioning.
    Water reaches boiling temperature after approximately 15 minutes.
    Warning: If during heating, no expansion water has escaped via safety group (black pressure valve) after 10 minutes switch off the power supply immediately and turn on the boiling water tap to relieve the water pressure.

    • The boiler is heated up when the ON/STANDBY button has a steady red light.
  5. To clean the tank activate the boiling water tap until cold water runs out.

Tap operation

Operation of mixer lever

  • Select hot water (fig. 3).

  • Select cold water (fig. 4).

  • Turn on mixer tap (fig. 5).

Operation of electronic knob

  • Activate tap: Press briefly 1x (fig. 6).

  • Press and turn backwards (to activate the boiling water selection (fig. 7).

  • For continuous boiling water: Hold selector knob pressed (fig. 8). Deactivate: Release the knob.

  • Filling mode short: Press briefly 2x (fig. 9). Stops automatically.
    Deactivate: Press briefly 1x.

  • Filling mode long: Press briefly 3x (fig. 10). Stops automatically.
    Deactivate: Press briefly 1x.

  • Hold the object to be filled close to the tap so that the object surrounds the delivery opening of the tap. This will prevent (hot) water from splashing.

  • For the optimum result when making coffee or tea, allow around 1 cup of water to run out before using the tap. In this way the air bubbles in the water disappear so that no foam forms on the surface of the tea.

Filling mode

  • Press 2x briefly for Pan filling.
    Pan filling: Boiling water (red) = 30 sec. flow

  • Press 3x briefly for Pan filling.
    Pan filling: Boiling water (red) = 60 sec. flow

Filter operation and replacement

  1. Press and hold the electronic knob (in the neutral positioning) for 10 seconds.
  2. Turn the electronic knob backwards to select the correct colour from the table on next page, based on the water hardness in your area. Press and hold the electronic knob for 2 seconds. The LED flash 3 times for confirmation and go back into the neutral position.

The LED in the neutral position reminds you 1 month in advance that the filter needs to be replaced. The LED in the neutral mode switch from white to orange.
If the filter reached the expire date the orange LED starts to pulsate until the filter has been replaced.
Slowly turn the used filter from the filterhead. During this process, the water supply line is hydraulically disconnected from the filter head and the system is depressurised; it may happen that pressure peaks, a small amount of pressure-relief water may escape from the filter head. Please note this and place an appropriate container underneath.
After the filter replacement, repeat step 1 and 2. If you registered your system you will get a reminder via email.
The use of a Franke filter is mandatory to protect the product against lime scale deposits. It is mandatory to change the filter based on the water hardness table.

Filter flushing

  • After 1 week stagnation 2 Litres

  • After 2 weeks stagnation 10 Litres

  • After 8 weeks stagnation The filter must be replaced.

    • default setting

Selection of neutral LED intensity
After 60 seconds of not using the tap it will switch automatically into the sleeping mode status, 50% LED intensity.
To change the sleeping mode setting you have to follow the below instruction.

  1. Activate the tap by pressing the electronic knob once.
  2. Press the electronic knob 5 times.
  3. The LED start flashing.
  4. Turn the knob to the preferred setting by turning the knob front or backwards:
  5. 50% intensity, default,
  6. 10% intensity,
  7. Switched off fully.
  8. After the selection press the electronic knob for 2 seconds to confirm. The tap flashes 3 times for confirmation.

Messages and malfunctions

Boiler messages

LED colour LED action Description
Blue Blinking Boiler does not have water.
Blue Steady Commissioning/system self-check.
Orange Blinking System failure; contact Franke service.
Red Blinking Boiler is heating up.
Red Steady Boiler is fully heated.

Tap messages

Troubleshooting

Electronic knob does not respond

Water leaks

Tap supplies no water

Tap supplies no boiling water

Tap supplies no warm water

The water from the tap is not boiling

The boiler causes a short-circuit

If you can‘t manage your malfunction or defect please contact the Franke service desk, installer or retailer.

Maintenance

General maintenance

  • Clean the tap only with Franke tap cleaner. Visit our Franke webshop.
  • Do not use cleaning agents containing a solvent or acid, such as lime scale removers, household vinegar or cleaning agents with acetic acid. These substances damage the surface. The tap will become matt and scratched.
  • Lime scale deposits can be prevented by drying the tap after use.
  • If lime scale deposits nevertheless occur, remove these using a citric acid-based cleaning agent.
  • Always use original Franke parts for maintenance or repair. This guarantees the safety and proper function of the product and safeguards any warranty claims.
  • Replacement or repair of parts may only be carried out by Franke Service.

Replacing the filter

  • Turn filter clock wise to remove from filter head.
  • Turn new filter anti clock wise to install. Reset the filter setting – see page 17 in the “Installation and user manual“ part 2 (filter installation).
  • The filter head has an integrated auto shut off water valve. No need to isolate water supply to change filter.

Descaling tap aerator

  • Always use a citric acid-based descaling agent. Other substances will damage the material!
  • Loosening and tightening can be made easier by wrapping an elastic band around the sleeve of the tap aerator. Take care that the sleeve of the tap aerator is not damaged by the use of tools.
  • Over the course of time, lime scale deposits will appear on and alongside the tap aerator.
  • Unscrew the sleeve of the tap aerarator.
  • Clean the tap aerator using a suitable descaling agent.
  • Place the tap aerator into the sleeve.
  • Place the gasket onto the tap aerator and screw on the sleeve finger-tight.

Check the details in the “Installation and user manual“ part 2, page 16.

Disposal

The symbol on the product or on the packaging indicates that the device must not be disposed of in the domestic waste. By disposing of the device in a proper way you help to avoid harmful consequences to environment and health.
Further information about recycling the device is available from the competent authority, the local refuse disposal service or the vendor of the device.
Dispose of the device, which is to be discarded, via a specialised waste collection point for electronic and electrical devices.
In accordance with the article of Legislative Decree no. 15 dated 25 July, Implementation of Directive 2002/96/EC regarding the reduction of the hazardous substances used in electrical and electronic appliances and in waste disposal. The barred dustbin symbol on the appliance indicates that at the end of its working life the product must not be disposed of as household waste.
Consequently, when the appliance has reached the end of its working life the user must take it to a suitable recycling centre for electronic and electrotechnical waste, or return it to the dealer when purchasing a new appliance of equivalent type.
Proper separate waste collection of the scrapped appliance for subsequent recycling, treatment and environmentally-friendly disposal helps prevent a potentially negative impact on the environment and health and facilitates recycling of the materials used in appliance construction.
Franke S.p.A.
Via Pignolini 2, 37019 Peschiera del Garda, ITALIA
Tel 045 6449311
www.franke.it

DECLARATION OF CONFORMITY

We, Franke spa addressed in Via Pignolini 2 37019 Peschiera del Garda ITALY, declare under our sole responsibility that the product:
FRANKE CODE:
119.0713.578
MODEL DESCRIPTION: Maris Boiler 7L Tank UK-Stecker
to which this declaration relates is in conformity with the following regulations and standards:
Regulations:

  • Electrical Equipment (Safety) Regulations 2016 – SI 2016 No. 1101
  • Electromagnetic Compatibility Regulations 2016 – SI 2016 No. 1091
  • Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 – SI 2012 No. 3032
  • Ecodesign for Energy-Related Products and Energy Information Regulations 2019
  • Pressure Equipment (Safety) Regulations 2016

Standards:

  • EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021
  • EN 60335-2-15:2016 + A11:2018 + A1:2021 + A2:2021 + A12:2021
  • EN 60529:1991 + A1:2000 + A2:2013 + AC:2019
  • EN IEC 61000-3-2:2019 + A1:2021
  • EN 61000-3-3:2013 + A1:2019 + A2:2021 + AC:2022
  • EN IEC 55014-1:2021
  • EN IEC 55014-2:2021
  • EN 50440:2015 + A1:2020
  • EN IEC 63000:2018

Place and date: Peschiera del Garda, 23/11/2023
Franke S.p.A.
VP R&D and Category Management Andrea Paiusco
R.E.A. VR091-5221/10047
C.F. e P.IVA 00209480235
P. IVA CEE IT00209480235
Franke S.p.A.
Via Pignolini 2, 37019 Peschiera del Garda, ITALIA
Tel 045 6449311
www.franke.it

EU DECLARATION OF CONFORMITY
We, Franke spa addressed in Via Pignolini 2 37019 Peschiera del Garda ITALY, declare under our sole responsibility that the product:

FRANKE CODE: 119.0713.575
MODEL DESCRIPTION: MARIS WATER HUB BOILER 7L EU |
to which this declaration relates is in conformity with the following directives and standards:
Directives:

  • 2014/35/EU “Low Voltage Directive”
  • 2014/30/EU “EMC Directive”
  • 2017/1369/EU “Framework for energy labelling”
  • 2011/65/EU “Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)”
  • 2015/863/EU “Amending Annex II to Directive 2011/65/EU”
  • 2014/68/EU “Pressure equipment”

Standards:

  • EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021
  • EN 60335-2-15:2016 + A11:2018 + A1:2021 + A2:2021 + A12:2021
  • EN 60529:1991 + A1:2000 + A2:2013 + AC:2019
  • EN IEC 61000-3-2:2019 + A1:2021
  • EN 61000-3-3:2013 + A1:2019 + A2:2021 + AC:2022
  • EN IEC 55014-1:2021
  • EN IEC 55014-2:2021
  • EN 50440:2015 + A1:2020
  • EN IEC 63000:2018

Place and date: Peschiera del Garda, 23/11/2023
Franke S.p.A.
VP R&D and Category Management Andrea Paiusco
R.E.A. VR091-5221/10047
C.F. e P.IVA 00209480235
P. IVA CEE IT00209480235
Franke S.p.A.
Via Pignolini 2, 37019 Peschiera del Garda, ITALIA Tel 045 6449311
www.franke.it

EU DECLARATION OF CONFORMITY
We, Franke spa addressed in Via Pignolini 2 37019 Peschiera del Garda ITALY, declare under our sole responsibility that the product:

FRANKE CODE: 119.0697.146
MODEL DESCRIPTION: Maris Water Hub Boiler 4L EU
to which this declaration relates is in conformity with the following directives and standards:
Directives:

  • 2014/35/EU “Low Voltage Directive”
  • 2014/30/EU “EMC Directive”
  • 2017/1369/EU “Framework for energy labelling”
  • 2011/65/EU “Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)”
  • 2015/863/EU “Amending Annex II to Directive 2011/65/EU”
  • 2014/68/EU “Pressure equipment”

Standards:

  • EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021
  • EN 60335-2-15:2016 + A11:2018 + A1:2021 + A2:2021 + A12:2021
  • EN 60529:1991 + A1:2000 + A2:2013 + AC:2019
  • EN IEC 61000-3-2:2019 + A1:2021
  • EN 61000-3-3:2013 + A1:2019 + A2:2021 + AC:2022
  • • EN IEC 55014-1:2021
  • EN IEC 55014-2:2021
  • EN 50440:2015 + A1:2020
  • EN IEC 63000:2018

Place and date: Peschiera del Garda, 31/07/2023
Franke S.p.A.
Chief Executive Officer
Barbara Borra
R.E.A. VR091-5221/10047
C.F. e P.IVA 00209480235
P.IVA CEE IT00209480235

Franke S.p.A.
Via Pignolini 2, 37019 Peschiera del Garda, ITALIA
Tel 045 6449311
www.franke.it

EU DECLARATION OF CONFORMITY
We, Franke spa addressed in Via Pignolini 2, 37019, Peschiera del Garda, ITALY, declare under our sole responsibility that the product:

FRANKE CODE: MODEL DESCRIPTION:
119.0698.122 Misc Maris Water Hub MFT elec J-canna SS
119.0698.123 Rub. Active Boiling 3in1 electr. J, MB
119.0698.124 Rub. Active Boiling 3in1 electr. J, CHR
119.0708.834 Active Boiling 3in1 electr. J-DS

to which this declaration relates is in conformity with the following directives and standards:
Directives:

  • 2014/30/EU “EMC Directive”
  • 2011/65/EU “Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)”
  • 2015/863/EU “Amending Annex II to Directive 2011/65/EU”

Standards:

  • EN IEC 61000-6-1:2019
  • EN IEC 61000-6-2:2019
  • EN IEC 61000-6-3:2021
  • EN IEC 61000-6-4:2019
  • EN IEC 55014-1:2021
  • EN IEC 55014-2:2021
  • EN IEC 63000:2018

Place and date: Peschiera del Garda, 31/07/2023
Franke S.p.A.
Chief Executive Officer
Barbara Borra
R.E.A. VR091-5221/10047
C.F. e P.IVA 00209480235
P.IVA CEE IT00209480235

EU DECLARATION OF CONFORMITY
Franke S.p.A.
Via Pignolini 2, 37019 Peschiera del Garda, ITALIA
Tel 045 6449311
www.franke.it
We, Franke spa addressed in Via Pignolini 2, 37019, Peschiera del Garda, ITALY, declare under our sole responsibility that the product:
FRANKE CODE:
133.0702.321
MODEL DESCRIPTION: RIC Maris Water Hub Hydraulic Box electr  to which this declaration relates is in conformity with the following directives and standards:

Directives:

  • 2014/35/EU “Low Voltage Directive”
  • 2014/30/EU “EMC Directive”
  • 2011/65/EU “Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)”
  • 2015/863/EU “Amending Annex II to Directive 2011/65/EU”
  • 2009/125/EG – Erp Directive (ÖkoDesign)

Standards:

  • EN IEC 62368-1:2020 + A11:2020
  • EN IEC 61000-3-2:2019 + A1:2021
  • EN 61000-3-3:2013 + A1:2019 +A2:2021 + A2:2021/AC:2022
  • EN 55032:2015 + AC:2016 + A11:2020 + A1:2020
  • EN 55035:2017 + A11:2020
  • EN IEC 61000-6-1:2019
  • EN IEC 61000-6-2:2019
  • EN 61000-6-3:2021
  • EN IEC 61000-6-4:2019
  • EN 55014-1:2021
  • EN 55014-2:2021
  • EN IEC 63000:2018

Place and date: Peschiera del Garda, 08/05/2023
Franke S.p.A.
Chief Executive Officer
Barbara Borra
R.E.A. VR091-5221/10047
C.F. e P.IVA 00209480235
P.IVA CEE IT00209480235
Franke S.p.A.
Via Pignolini 2, 37019 Peschiera del Garda, ITALIA
Tel 045 6449311
www.franke.it

DECLARATION OF CONFORMITY
We, Franke spa addressed in Via Pignolini 2 37019 Peschiera del Garda ITALY, declare under our sole responsibility that the product:
FRANKE CODE:
133.0702.240
MODEL DESCRIPTION: RIC Maris Water Hub Hydraulic Box elecUK
to which this declaration relates is in conformity with the following regulations and standards:

Regulations:

  • Electrical Equipment (Safety) Regulations 2016 – SI 2016 No. 1101
  • Electromagnetic Compatibility Regulations 2016 – SI 2016 No. 1091
  • Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 – SI 2012 No. 3032
  • Ecodesign for Energy-Related Products and Energy Information Regulations 2019

Standards:

  • EN IEC 62368-1:2020 + A11:2020
  • EN IEC 61000-3-2:2019 + A1:2021
  • EN IEC 61000-3-3:2013 + A1:2019 +A2:2021 + A2:2021/AC:2022
  • EN IEC 55032:2015 + AC:2016 + A11:2020 + A1:2020
  • EN IEC 55035:2017 + A11:2020
  • EN IEC 63000:2018
  • EN IEC 61000-6-1:2019
  • EN IEC 61000-6-2:2019
  • EN IEC 61000-6-3:2021
  • EN IEC 61000-6-4:2019
  • EN IEC 55014-1:2021
  • EN IEC 55014-2:2021

Place and date: Peschiera del Garda, 17/10/2023
Franke S.p.A.
Chief Executive Officer Barbara Borra
R.E.A. VR091-5221/10047
C.F.e P.IVA 00209480235
P.IVA CEE IT00209480235
Franke S.p.A.
Via Pignolini 2, 37019 Peschiera del Garda, ITALIA
Tel 045 6449311
www.franke.it

DECLARATION OF CONFORMITY
We, Franke spa addressed in Via Pignolini 2 37019 Peschiera del Garda ITALY, declare under our sole responsibility that the product:

FRANKE CODE: 119.0698.539
MODEL DESCRIPTION: Maris Boiler 4L Tank UK-Stecker
to which this declaration relates is in conformity with the following regulations and standards:

Regulations:

  • Electrical Equipment (Safety) Regulations 2016 – SI 2016 No. 1101
  • Electromagnetic Compatibility Regulations 2016 – SI 2016 No. 1091
  • Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 – SI 2012 No. 3032
  • Ecodesign for Energy-Related Products and Energy Information Regulations 2019
  • Pressure Equipment (Safety) Regulations 2016

Standards:

  • EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021
  • EN 60335-2-15:2016 + A11:2018 + A1:2021 + A2:2021 + A12:2021
  • EN 60529:1991 + A1:2000 + A2:2013 + AC:2019
  • EN IEC 61000-3-2:2019 + A1:2021
  • EN 61000-3-3:2013 + A1:2019 + A2:2021 + AC:2022
  • EN IEC 55014-1:2021
  • EN IEC 55014-2:2021
  • EN 50440:2015 + A1:2020
  • EN IEC 63000:2018

Place and date: Peschiera del Garda, 17/10/2023
Franke S.p.A.
Chief Executive Officer Barbara Borra
R.E.A. VR091-5221/10047
C.F. e P.IVA 00209480235
P. IVA CEE IT00209480235
© Franke Technology and Trademark Ltd., Switzerland | 2024-01-08 | V01 I ID: 20261414
franke.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>