BROAN E60 Series Range Hood Installation Guide
- August 20, 2024
- Broan
Table of Contents
BROAN E60 Series Range Hood
Product Information
Specifications:
- Models : E6030SSM, E6036SSM, E6042TSSM, E6048TSSM, E6430SSM, E6436SSM
- Manufacturer : Broan NuTone LLC
- Address : 926 West State Street, Hartford, Wisconsin, USA 53027
- Website : www.broan-nutone.com
- Contact : 800-558-1711
Product Usage Instructions
Lights Control:
The LED lighting is controlled by a rotary switch. Turn the rotary switch
clockwise until hearing a click for low-intensity lighting. Turn it again
clockwise for high intensity lighting. To decrease intensity or turn off, turn
the switch counterclockwise.
Ventilator Operation:
The ventilator has an ON/OFF switch to control its operation. Use the switch
to start and stop the ventilator.
HEAT SENTRYTM Thermostat:
Your unit is equipped with a HEAT SENTRYTM thermostat. It automatically turns
on the blower if excessive heat is detected above the cooking surface. If the
blower is off, it will turn on to the last selected speed. If the blower is
already on, the speed will remain the same.
WARNING: The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. To stop the blower in this case, set the main power switch (located behind the filters for E60 models or at the bottom of the hood for E64 models) to theOFF position or do so from the main electrical panel.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
- Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
- Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
- Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
- Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
- When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
- Ducted fans must always be vented to the outdoors.
- Do not use this unit with any separate solid-state speed control device.
- To reduce the risk of fire, use only metal ductwork.
- This unit must be grounded.
- When installing, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
- When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
- Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
- Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
- Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
- Use proper pan size. Always use cookware appropriate for the size of the surface element.
**TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:***
- SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
- NEVER PICK UP A FLAMING PAN – You may be burned.
- DO NOT USE WATER, including wet dishcloths or towels – violent steam explosion will result.
- Use an extinguisher ONLY if:
- You know you have a Class ABC extinguisher and you already know how to operate it.
- The fire is small and contained in the area where it started.
- The fire department is being called.
- You can fight the fire with your back to an exit.
Based on “Kitchen Fire Safety Tips” published by NFPA
CAUTION
- For indoor use only.
- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
- To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
- Your hood motor has a thermal overload which will automatically shut off the motor if it overheats. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.
- The minimum hood distance above cooktop must not be less than 24″ for an electrical range and 30” for a gas range. A maximum of 30” above cooktop is recommended for best capture of cooking impurities.
- Two installers are recommended because of the large size and weight of this unit.
- To reduce the risk of fire and to properly exhaust air on a ducted installation, be sure to duct air outside – Do not exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage.
- Because of the high exhausting capacity of this hood, make sure enough air is entering the house. Open a window close to or in the \kitchen.
- To reduce the risk of fire and electrical shock, the Broan E60-E64 Series models should only be installed with their own built-in blowers.
- Please read specification label on product for further information and requirements.
For complete warranty statement or to learn more about the instructions above, please type your model number in on our website.
Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville, Québec, Canada J2C
7W9 Broan-NuTone.ca 800-567-3855
Broan NuTone LLC, 926 West State Street, Hartford, Wisconsin, USA 53027
Broan-NuTone.com
800-558-1711
Operation
Lights:
The LED lighting is controlled by a rotary switch. Turn the rotary switch
clockwise until hearing a click – it is low-intensity lighting position, turn
again the rotary switch clockwise until hearing another click – it is high-
intensity lighting position. Turn the rotary switch counterclockwise to
decrease lighting intensity or to turn it off.
Blower:
- The blower is operated using two controls.
- Use the on/off rocker switch to start and stop the blower.
- Turn the rotary switch clockwise until hearing a click – speed 2 position, turn again the rotary switch clockwise until hearing another click – speed 3 position, and turn again the rotary switch clockwise until hearing another click – speed 4 position.
- Turn the rotary switch counterclockwise to decrease speed.
- When the rocker switch is turned on, the blower operates as per the current speed position.
HEAT SENTRY TM
Your unit is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn the blower on if it senses excessive heat above the
cooking surface.
- If blower is OFF – it turns blower ON to the last selected speed.
- If blower is already ON speed will remain the same.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF using the
rocker switch. If you must stop the blower, set the main power switch (located
behind the filters, on inner side of the unit faceplate – E60 models) or
(located at the bottom of the hood – E64 models) in OFF position (if it is
possible to do so safely). If not, do it from the main electrical panel.
Code Ready Technology® Activation
The Code Ready Technology option allows to change the blower output from the factory setting to a maximum of 400 CFM. Activating the CRT option will reduce the airflow so that the range hood will perform within the allowable limit of Make-Up Air (MUA) codes (to meet some building code requirements). Do not change the blower CFM setting unless this change is required by the code. This change will alter the performance of the product.
IMPORTANT NOTE:
For dual motor models, activating the switch will change the blower output to
a maximum of 600 CFM. A power outage will not deactivate the CRT.
- Remove grease filters
- Remove electrical compartment cover
- Set the CRT switch
- Locate the CRT sticker near the HVI Certification label inside range hood. Check the proper box (400 CFM). Reinstall the electrical compartment cover.
Maintenance
Grease Filters
The hybrid baffle filters should be cleaned frequently. Use a warm dishwashing
detergent solution. The hybrid baffle filters are dishwasher safe. Clean the
filters in the dishwasher using a non-phosphate detergent. Discoloration of
the filters may occur if using phosphate detergents, or as a result of local
water conditions – but this will not affect filters performance. This
discoloration is not covered by the warranty. To minimize or prevent
discoloration, hand wash filters using a mild detergent.
Grease Drip Rail
The grease drip rail should be cleaned frequently. Lift it out from the hood
and use a warm detergent solution. Allow grease drip rail to dry completely
before reinstalling it in the hood.
Hood Cleaning
Stainless Steel Cleaning:
Do:
- Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
- Always clean in the direction of original polish lines.
- Use clean rag or cloth soaked with clean water (2 or 3 times) after cleaning. Wipe dry completely.
- You may also use a specialized household stainless steel cleaner.
Don’t:
- Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
- Use any harsh or abrasive cleansers.
- Allow dirt to accumulate.
- Let plaster dust or any other construction residues reach the hood. During construction/renovation, cover the hood to make sure no dust sticks to stainless steel surface.
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be used close to a range.
Installation
Recommended Tools and Accessories
Box Content
Necessary hardware included in parts bag (parts left over are spare parts)
Accessories (sold separately)
- Model 427 (4-1/2″ x 18-1/2” to 10” round, 6” high – lateral)
- Model 423 (4-1/2″ x 18-1/2” to 10” round – vertical)
- HCK44 – Range hood Electrical Cord Connection Kit
- Some illustrations may slightly differ from your actual range hood.
- Dimensions are in inches unless otherwise specified
-
Select Installation Type
- Single blower/ Ventilateur simple
- Dual blower/ Ventilateur double
Use metal foil duct tape to seal duct joints and openings
-
Hood Specifications
-
Installation Preparation
-
A = Duct opening
-
B = Power cable opening
HOOD WIDTH / LARGEUR DE LA HOTTE / ANCHURA DE LA CAMPANA| C| D
---|---|---
E60| E64
30| 13| 10-7/8| 2-5/16
36| 16| 10-7/8| 2-5/16
42| 19| 10-7/8| 2-5/16
48| 22| 10-7/8| 2-5/16 -
Remove grease filters
-
Remove Grease Drip Rail
-
Remove electrical compartment cover
-
Remove dampers/adaptor from inside the hood.
-
Remove Proper Knockout A or B
-
Remove Power Cable Proper Knockout and Install Strain Relief
-
Horizontal Discharge Only – Remove Blower
-
Install Proper Damper/Adaptor
-
E60 Models Installation ONLY CAUTION
- Due to the weight of this hood, ensure that the wood strip is attached to all of the available studs (2 studs minimum for a 30″ width hood, more as hood width increases); not into the drywall alone.
- Install hood on wood mounting strip.
- Run power cable in the hood
-
E64 Models Installation ONLY
-
Wiring
-
Reinstall electrical compartment cover
-
Reinstall Grease Drip Rail
-
Horizontal Discharge Only – Reinstall Blower
Screw ground screw -
Reinstall grease filters
Screw ground screw
Replacement Parts
Replacement Parts and Repairs
In order to ensure your unit remains in good working condition, you must use
Broan-NuTone genuine replacement parts only. Broan-NuTone genuine replacement
parts are specially designed for each unit and are manufactured to comply with
all the applicable certification standards and maintain a high standard of
safety. Any third party replacement part used may cause serious damage and
drastically reduce the performance level of your unit, which will result in
premature failing. Broan-NuTone recommends to contact a certified service
depot for all replacement parts and repairs.
K ey N o .|
P art N o .
|
d escriPtioN
| Q ty ( hood width )
---|---|---|---
30”/ Po /
Pulg .
| 36”/ Po /
Pulg .
| 42”/ Po /
Pulg .
| 48”/ Po /
Pulg .
1| SV13296| Damper 3-1/4″ x 10″ / Volet 3-1/4 po x 10 po / Compuerta 3-1/4
pulg. x 10 pulg.| 1| 1| –| –
2| SV17797| aDaptor 4-1/2″ x 18-1/2″ / aDaptateur 4-1/2 po x 18-1/2 po /
aDaptaDor 4-1/2 pulg. x 18-1/2 pulg.| –| –| 1| 1
3| SV08543| Damper 8″ / Volet 8 po / Compuerta 8 pulg.| 1| 1| –| –
4| S99271693| leD moDule (Set of 2) / moDule Del (jeu De 2) / moDulo leD
(juego De 2)| 3| 3| 3| 3
5| S1111962| roCker SwitCh oN/off / iNterrupteur à baSCule marChe/arrÊt /
CoNmutaDor eNCeNDiDo/apagaDo| 1| 1| 1| 1
6| S1115852| rotary SwitCh (Set of 2) / iNterrupteur ( jeu De 2) / CoNmutaDor
(juego De 2)| 1| 1| 1| 1
7| SV03435| heat SeNtry thermoStat / thermoStat heat SeNtry / termoStato heat
SeNtry| 1| 1| 1| 1
8| S97021509| blower / VeNtilateur – VeNtilaDor| 1| 1| 2| 2
9| S99271379| CapaCitor 25 µf / CoNDeNSateur 25 µf / CoNDeNSaDor 25 µf| 1| 1|
2| 2
10
| SV17640| greaSe Drip rail 30″ / gouttière 30 po / CaNal reColeCtor De graSa
30 pulg.| 1| –| –| –
SV17641| greaSe Drip rail 36″ / gouttière 36 po / CaNal reColeCtor De graSa 36
pulg.| –| 1| –| –
SV17642| greaSe Drip rail 42″ / gouttière 42 po / CaNal reColeCtor De graSa 42
pulg.| –| –| 1| –
SV17643| greaSe Drip rail 48″ / gouttière 48 po / CaNal reColeCtor De graSa 48
pulg.| –| –| –| 1
11
| SV17606| hybriD baffle filter e60 (8.84″ x 15.125″) / filtre à ChiCaNeS
hybriDe e60 (8,84 po x 15,125 po) / filtro DefleCtor híbriDo e60 (8,84 pulg. x
15,125 pulg.)| 2| –| 2| –
SV17609| hybriD baffle filter e60 (11.84″ x 15.125″) / filtre à ChiCaNeS
hybriDe e60 (11,84 po x 15,125 po) / filtro DefleCtor híbriDo e60 (11,84 pulg.
x 15,125 pulg.)| 1| 3| 2| 4
SV17600| hybriD baffle filter e64 (8.84″ x 9.80″) / filtre à ChiCaNeS hybriDe
e64 (8,84 po x 9,80 po) / filtro DefleCtor híbriDo e64 (8,84 pulg. x 9,80
pulg.)| 2| –| –| –
SV17603| hybriD baffle filter e64 (11.84″ x 9.80″) / filtre à ChiCaNeS hybriDe
e64 (11,84 po x 9,80 po) / filtro DefleCtor híbriDo e64 (11,84 pulg. x 9,80
pulg.)| 1| 3| –| –
12| SV08578| buttoNS (Set of 2) / boutoNS (jeu De 2) / botoNeS (juego De 2)|
1| 1| 1| 1
13| SV08093| iNDiCator light / lampe témoiN / luz iNDiCaDora| 1| 1| 1| 1
| S1114464| maiN harNeSS / harNaiS priNCipal / arNéS priNCipal| 1| 1| 1| 1
| S1114629| DupliCatioN harNeSS / harNaiS De DéDoublemeNt / arNéS De DupliCaCióN| –| –| 1| 1
*| SV08352| partS bag / SaC De pièCeS / bolSa De piezaS| 1| 1| 1| 1
Wiring Diagram
FAQ
Q: What should I do in case of a range top grease fire?
A: Follow these steps to reduce the risk of injury and handle the fire
effectively:
- Smother flames with a lid, cookie sheet, or metal tray, then turn off the burner.
- Do not pick up a flaming pan to avoid burns.
- Avoid using water as it can cause a steam explosion.
- Use an extinguisher only if you are trained to use it and meet certain conditions.
Q: How do I adjust the lighting intensity?
A: Turn the rotary switch clockwise for high-intensity lighting and
counterclockwise to decrease intensity or turn it off
Q: What is the function of the HEAT SENTRY thermostat?
A: The HEAT SENTRY thermostat turns on the blower if excessive heat is
detected above the cooking surface to revent overheating.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>