HERSCHEL GH-300-W Inspire Wall and Ceiling Mounted Infrared Heaters Instruction Manual
- June 4, 2024
- HERSCHEL
Table of Contents
HERSCHEL GH-300-W Inspire Wall and Ceiling Mounted Infrared Heaters
IMPORTANT SAFETY PRECAUTIONS
READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE. Failure to observe these instructions will invalidate the warranty. Do not disassemble. No user-serviceable parts inside.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
- This appliance must be disconnected from its power source during installation or service activities and when replacing.
- The INSPIRE is not equipped with an integrated device to control the room temperature. If intended for use in an enclosed space for the purposes of room heating, Herschel iQ controls must be used. If you do not fit a room temperature controller, DO NOT use for room heating when rooms are occupied by people incapable of leaving the room on their own, unless constant supervision is provided. Herschel is not responsible for any breach of EcoDesign or Safety legislation where the heaters are used in an enclosed space without use of a Herschel iQ controller.
- In order to avoid overheating and potential fire hazard, DO NOT cover the heater with insulating material or similar material under any circumstances. DO NOT locate the heater within 0.3m of any flammable materials (eg. Furniture, curtains).
- DO NOT touch the heater when in use. Herschel panel heaters have a surface temperature of around 95°C / 248°F and prolonged contact with the heater will cause burns and injury.
- DO NOT operate the heater if the cord or plug is damaged or after the heater malfunctions, or if it has been dropped or damaged in any manner. Check each heater for damage before installation. Make sure that the heater itself, the plug and the cable are free of any visible signs of damage. The supply cord cannot be replaced. If the cord is damaged the appliance must be scrapped in accordance with the local Waste Electrical Equipment regulations.
- GLASS & MIRROR PANEL MODELS. Handle carefully and avoid stressing the glass mechanically. Do not use the heater if the glass panels are damaged. Disconnect the heater and do not put it into operation again. Dismount the heater immediately to reduce the danger of direct impact from falling pieces and dispose of the unit in accordance with the local Waste Electrical Equipment regulations.
- This heater must only be used for the heating of people or buildings. The heater is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge. Children should be kept away and should not be left unsupervised around the unit.
- All operators should only switch on/off the appliance provided that it has been placed or installed in its intended operating position in accordance with these instructions. Children must not plug in, switch on or regulate the appliance or perform user maintenance including cleaning.
- IMPORTANT: Herschel panels are designed for use with an AC voltage between 220-240 volts, 50 Hz AC. If your supply voltage exceeds 240 Volts do not use the heater and refer to your local dealer.
- IMPORTANT: The heater must be mounted on a non-flammable surface.
SAVE THESE INSTRUCTIONS.
WATER INGRESS PROTECTION
Herschel Inspire panels are rated to a standard (minimum IP54) enabling them to be located within zone 2 in a bathroom. This means they can be placed above a sink and outside other splash zones, or the white panels can be installed on the ceiling. They cannot be installed in zones 0 or 1. Installation in potentially wet or humid rooms such as bathrooms must be carried out by a suitably qualified installer and comply with local electrical safety requirements. Installation must be such that:
- the heater must not be able to become detached from the fittings and fall into a bathtub, shower, swimming pool or other water container;
- Switches and other controls cannot be touched by a person in the bath or shower.
If in doubt, do not install. Herschel Infrared Ltd shall not be liable for any loss, damage or injury caused or resulting from inadequate fitting or incorrect placement of heaters close to water sources.
POSITIONING
This is an infrared panel heater. It heats objects by transferring energy
directly from the heater into the object. Therefore, consider placing the
heater where it will not be immediately obstructed by objects like furniture
or where it cannot effectively radiate out, such as at the edge or in the
corners of a room. Objects placed in front of the heater will heat up and can
prevent effective heat dispersion into the room. Avoid placing it opposite
windows or open doorways. Only White Panels are designed for ceiling mounting,
please check with your local dealer before mounting to the ceiling. To ensure
a firm mounting point is obtained for ceiling installations, locate a ceiling
joist (which may be behind plasterboard) to install the mounting brackets
onto. If mounting in a ceiling grid do not place insulation material directly
onto the rear of the panel. Herschel Glass panels consist of ESG (security
glass). This is a special mechanically stabilized glass, which will break in
small, edgeless pieces. The mounting location should be chosen in such a way
that the glass cannot be accidentally broken and people will not be in danger
from a possible break in the glass. The minimum distance from the back side of
the panel must be 25 mm to the mounting surface. This will always be the case
if the mounting hardware provided is used. Objects in front of the panel must
be at least 400mm away and 200 mm away from the sides. The distance from the
sides of the heater must also be respected if it is intended to recess the
heater into the wall or ceiling. Failure to do so will cause excess heat to
build up behind the heater and will void the warranty. The distance between
the sides of the heater and the sides of any adjacent heater must be a minimum
of 800mm. Failure to do so could cause excess heat to build up behind the
heaters and will void the warranty.
INSTALLATION
WARNING
Installation should only be carried out by trained and approved engineers or competent persons. If the heating panel is being hard wired, the electrical installation should only be carried out by suitably qualified personnel. Wiring to this appliance must be connected in accordance with the relevant national electrical safety standards. It is a Class 1 appliance and must be earthed.When placed in public areas, installation must comply with relevant local electrical standards. For certain public buildings like schools and care homes the heaters must be installed according to the specific legislation for these types of buildings. The electrical supply to the unit should be provided by connecting to a circuit protected by a fuse or residual current device (RCD) or Ground Fault circuit interrupter (GFCI ) suitable for the electrical rating of the appliance. Temperature control must be effected by a Thermostat. Colour coding used in the supplied mains cable: BROWN wire is to be connected to LIVE (‘L’), the BLUE wire to NEUTRAL (‘N’) and the GREEN/YELLOW wire to EARTH (‘E’).
CAUTION
- Ensure mains power is OFF before commencing an installation involving fixed wiring.
- Any fixed wiring outside the heater coming into contact or close proximity to the heater must be protected by sleeving with a temperature rating of at least 90°c.
- All cabling behind the appliance must take the shortest route to the edge of the heater.
- Ensure that the power cable is not coiled. Shorten the power cable if possible and do not place excess cable on the rear of the heater.
- Electrical connections must not be made behind the heater regardless of wall or ceiling-mounting position.
- The heater is not to be located immediately below a socket outlet in either wall or ceiling-mounted positions.
- DO NOT drill through the heater as this will cause irreparable damage and is also dangerous.
- DO NOT connect a heater that is damaged in any manner to the power network.
When ceiling mounting use the narrower slide-in channel in the brackets supplied. When wall or ceiling mounting ensure that the adjustable spacing feet in the corners are screwed out until a slight pressure is established between the panel and the mounting surface. For mounting the Herschel panel use the supplied mounting hardware only and install in accordance with the installation guide. Herschel Infrared Ltd cannot accept responsibility for damage, loss or injury caused by, or resulting from incorrectly installed heaters. Herschel Infrared Ltd will not assume liability for consequential loss however caused.
MAINTENANCE AND REPAIR
The Herschel panel must be installed, uninstalled, cleaned or transported only when cold.
CLEANING
Before attempting to clean the panel, unplug the heater, isolate the unit
from the electrical supply and allow it to completely cool down. DO NOT
immerse the Herschel panel heater in water or splash water onto it. Clean the
heater with a damp cloth . For glass models glass cleaner can be used. Never
use a wet cloth. When clean, dry the surfaces with a dry cloth. DO NOT apply
abrasive materials, solvents or solvent wipes to the surface as this can cause
irreparable damage. Wait until the unit is completely dry before use.
REPAIR
DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. Repairs must only be carried out by an authorised Herschel service partner.
DISPOSAL
The heater is an electrical product and at the end of its working life it
should be disposed of in accordance with local regulations.
OPERATION
If operated as a fixed space heater, Herschel Inspire must be controlled by a
Herschel iQ thermostat. European regulations from January 2018 require all
fixed electric space heaters to use a controller incorporating a minimum of a
7 day programme and temperature control plus at least one of the following:
- Window open detection (available on all iQ controls)
- Remote controller or remote application (optional with purchase of iQ Hub)
- An “adaptive start” function to optimize energy used to start each programmed period (Optional with Purchase of T1 Thermostat).
The Herschel IQ control systems were created specifically for Infrared heating with this legislation in mind and therefore satisfy the requirements. See Appendix 1 for full details. For other controls, you will have to consult with your dealer. If used as a portable heater using Inspire Feet, the Herschel Inspire is only suitable for well-insulated spaces or occasional use and must use room temperature control. On first use, the Inspire picture panels may emit a slight odor. This is normal and represents the colors in the picture curing. The colors will be unaffected and the smell will disappear in a short time. Please note it is possible the heater may discolor with use – this is caused by air-born pollution and is not a fault. Clicking noises caused by thermal expansion are also common and will not affect the heating function. The heater is designed to last many years and incorporates several safety functions, but if the heater has not been used or installed in adherence to these instructions, emits any noise, smells or reaches high temperatures in excess of 100°C, discontinue using the heater and refer to your local Herschel dealer.
WARRANTY
Register your product here: https://www.herschel-infrared.co.uk/customer- service/warranty-registration/ Within ten years from date of purchase Herschel will repair or replace the heater where the fault is due to defects in materials or workmanship. In the event of a warranty claim please consult your local dealer and return the heater together with proof of purchase. A prerequisite for validity of the warranty is use at the specified supply voltage of the heater and use in accordance with the conditions specified in this manual. Any further warranty or claims are excluded.The warranty covers the repair or replacement of the defective product only and Herschel shall have no liability for installation costs or consequential loses however incurred. Removing the serial number will void the warranty. The warranty will also be void if the heater has been tampered with or opened in any way. The product power label must be left on the panels where they can be accessed after installation if necessary.Herschel Infrared Ltd will assume no responsibility for scratches on surface or frames after first use. Herschel Infrared Ltd cannot accept responsibility for damage, loss or injury caused by ingress of water or moisture, accidental damage, mishandling, external impact, adjustment by unauthorised personnel or failure to follow the correct maintenance and safety precautions as stated in the manual. Refer to Herschel Infrared Ltd’s warranty policy for full details. See https://www.herschel- infrared.co.uk. Note your serial number for future reference:
PANELS COVERED BY THESE INSTRUCTIONS
Standard White Panels:
- CL-200
- CL-300
- CL-400
- CL-500
- CL-750
- CL-750L
- CL-900
- CL-1200
- CL-1200L
Mirror Panels:
- SH-200
- SH-300
- SH-400
- SH-500
- SH-750
- SH-900
- SH-1200L
Picture Panels:
- BH-200
- BH-300
- BH-400
- BH-500
- BH-750
- BH-900
- BH-1200
Coloured Glass Panels:
- GH-300
- GH-500
- GH-750
- GH-900
Blackboard Panels:
- HB-750
- HB-900
- HB-1150
Installation Guide for Herschel Inspire Units
Assembly Kit
Please check the enclosed assembly kit consists of: 2x fixings brackets, 8x
screws, 8x rawlplugs
Step 1
The distance between the two mounting points of each panel is half the length
of the panel. (e.g. 750W panel is 90cm long, so mounting points are 45cm
apart). Mark these two points on the wall where you want the heater to be
mounted and using the supplied mounting plates, mark the eight drilling holes
onto the intended installation site.
Step 2
Drill holes into the installation site in the marked places and then place the
wall plugs into the drilling holes.
Step 3
To fix the included fixing brackets to the installation site turn the screws
in as far as possible through the grooves of the fixing brackets into the wall
plugs. Step 4
Before placing your Herschel far infrared heater panel onto the fixing
brackets please check that the four distance pieces on the rear of the far
infrared heater panel are screwed in as far as possible.
Step 5
Now fit the far infrared heater panel onto the two wall holders. If ceiling
mounting please use the narrower slide-in channel. Step 6
Unscrew the four distance pieces on the rear of the far infrared heater panel
so that the panel is fixed securely to the wall or ceiling and cannot be
removed.
APPENDIX 1 – COMPLIANCE WITH ECODESIGN DIRECTIVE 2009/125/EC:
All Herschel Inspire heaters must be used with Herschel iQ controllers to
comply with ErP Regulation 2015/1188 & Supplement 2016/2282 of the EcoDesign
directive 2009/125.
Herschel is not responsible for any breach of the legislation where Inspire is
used without the appropriate iQ controller.
When installed as fixed Electric Space Heaters
- Seasonal space heating energy efficiency pre Lot 20 = 30%
- Efficiency Under EC/2009/125 = 38 – 40% (depending on combination of controls
Applies to ALL models covered by these instructions
Model Identifier: Herschel Inspire Series (all)
Item| Symbol| Value| Unit| | Item| Unit
Heat Output| | Type of heat input for electric storage local space
heaters only (select one)
Nominal Heat output| P nom| Heater Rated
Wattage
| kW| | Manual heat charge control with integrated thermostat| Not applicable
Minimum heat output
(indicative)
| P min| N/A| kW| | Manual heat charge control with room and/or outdoor
temperature feedback
| Not applicable
Maximum continuous heat
output
| P max,c| Heater Rated
Wattage
| kW| | Electronic heat charge control with room and/or outdoor
temperature feedback
| Not applicable
Auxiliary Electricity
consumption
| | | | | Fan assisted heat output| Not applicable
At nominal heat
output
| el max| 0| kW| | Type of heat output/room temperature control
(select one)
At minimum heat
output
| elmin| 0| kW| | Single stage heat output and no
room temperature control
| No
In standby mode| el SB| 0| kW| | Two or more manual stages, no
room temperature control
| No
| | With mechanical thermostat
room temperature control
| No
| | With electronic room
temperature control
| No
| | Electronic room temperature
control plus day timer
| No
| | Electronic room temperature
control plus week timer
| 7%
All iQ controls
| | Other Control options (multiple selections
possible)
| | Room temperature control with
presence detection
| No
| | Room temperature control with
open window detection
| 1%
All iQ controls
| | With distance control option| 1%
iQ Hub + App
| | With adaptive start control| 1%
iQ T1 only
| | With Working Time Limitation| No
| | With Black Bulb sensor| No
Contact Details| Herschel Infrared Ltd, Bristol BS93AA. www
.herschel-infrared.co.uk
When installed as a portable heater using Inspire Feet
- Seasonal space heating energy efficiency pre Lot 20 = 30%
- Efficiency EC/2009/125 = 36%
All Herschel Inspire Panels are compliant if used with a plugin electronic room temperature control.
Applies to ALL models covered by these instructions:
Model Identifier: Herschel Inspire Series (all)
Item| Symbol| Value| Unit| | Item| Unit
Heat Output| | Type of heat input for electric storage local space
heaters only (select one)
Nominal Heat output| P nom| Heater Rated
Wattage
| kW| | Manual heat charge control with integrated thermostat| Not applicable
Minimum heat output (indicative)| P min| N/A| kW| | Manual heat charge
control with room and/or outdoor temperature
feedback
| Not applicable
Maximum continuous heat
output
| P max,c| Heater Rated
Wattage
| kW| | Electronic heat charge control with room and/or outdoor temperature
feedback
| Not applicable
Auxiliary Electricity
consumption
| | | | | Fan assisted heat output| Not applicable
At nominal heat
output
| el max| 0| kW| | Type of heat output/room temperature control
(select one)
At minimum heat
output
| elmin| 0| kW| | Single stage heat output and no
room temperature control
| No
In standby mode| el SB| 0| kW| | Two or more manual stages, no
room temperature control
| No
| | With mechanical thermostat room
temperature control
| No
| | With electronic room temperature
control
| 7%
| | Electronic room temperature
control plus day timer
| No
| | Electronic room temperature
control plus week timer
| No
| | Other Control options (multiple selections possible)
| | Room temperature control with
presence detection
| No
| | Room temperature control with
open window detection
| No
| | With distance control option| No
| | With adaptive start control| No
| | With Working Time Limitation| No
| | With Black Bulb sensor| No
Contact Details| Herschel Infrared Ltd, Bristol BS93AA. www
.herschel-infrared.co.uk
In this portable configuration, this product is only suitable for well- insulated spaces or occasional use.
References
- Infrarotheizung.de – Wir machen Werkstattheizungen und Hallenheizungen
- Herschel Infrared Heaters: UK No. 1 infrared heating panel manufacturer
- Herschel Infrared Product Warranty Registration
- Herschel infrarood productgarantieregistratie
- Riscaldatori a infrarossi Herschel: n° 1 in Italia per il riscaldamento a infrarossi
- Registrazione della garanzia del prodotto a infrarossi Herschel
- Radiateurs infrarouges Herschel: n ° 1 français du chauffage infrarouge
- Enregistrement de la garantie du produit infrarouge Herschel
- Calefaccion por infrarrojos Herschel: radiadores de bajo consumo, España
- Registro de garantía del producto infrarrojo de Herschel
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>