BROAN Aer110lbn Energy Star Certified Bath Fan Instruction Manual

May 15, 2024
Broan

BROAN Aer110lbn Energy Star Certified Bath Fan

BROAN Aer110lbn Energy Star Certified Bath Fan 

SAFETY INFORMATION

Installer: Leave this manual with the homeowner

READ AND SAVE THESE INSTRUCTIONS

WARNING

To reduce the risk of fire, electric shock, or injury to persons, observe the following:

  • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  • Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  • Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
  • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  • Ducted fans must always be vented to the outdoors.
  • This unit must be grounded.

CAUTION

  • For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  • For installation in flat ceilings only.
  • To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
  • Please read specification label on product for further information and requirements.

CLEANING & MAINTENANCE

For quiet and efficient operation, long life, and attractive appearance – remove grille and vacuum interior of unit with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).

OPERATION

Use an on/off switch or speed control to operate this ventilator. See “Wiring Diagram” for details.

ALL INSTALLATIONS

Start here.

All Installations

IMPORTANT – The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
All Installations
OPTION – To mount housing anywhere between ceiling framing: Use optional Hanger Bar Kit (sold separately from local distributors or website). Follow mounting instructions included with kit.

  1. Remove blower and all packing material from fan housing.
    All Installations

  2. Remove wiring panel from fan housing (if already installed).

  3. A pair of flanges may be attached to housing if desired or required.
    Snap both flange pieces under rolled-over edge of housing (all four sides).

  4. Attach grille brackets* to housing.
    All Installations

  • Grille brackets are located in Styrofoam packing material in box.
    NEW CONSTRUCTION
    For Retrofit Installation
    RETROFIT

    1. Remove old fan.
      Enlarge ceiling opening (if necessary) to 9¾” (parallel to joist) by 10½” (perpendicular to joist). Leave ductwork and wiring in place.
      All Installations

    2. Fold mounting ears flat against housing.

    3. Connect wiring.
      Connect power cable to housing with appropriate UL approved connector (not included). Make wiring connections as shown in “Wiring Diagram” section. Reinstall wiring panel and secure with screw from parts bag.

    4. Mount fan to ceiling structure.
      Mount housing to ceiling structure with standard drywall or wood screws (not included) in locations shown.
      *Center hole optional.
      All Installations

    5. Connect 4-in. round duct.

    6. Pull existing ducting through housing discharge opening.

    7. Attach and tape ducting to duct connector.

    8. Push connector/ducting back through opening.

    9. Engage tabs and secure with screw from parts bag.
      All Installations
      All Installations

    10. Attach damper/duct connector to fan housing.
      Push connector through opening from inside of housing. Engage tabs and secure with screw from parts bag.
      All Installations

    11. Mount housing to ceiling structure.
      Make sure bottom of housing will be flush with finished ceiling. For proper location when using ½” ceiling material: Bend out housing tabs to fit against bottom of structure. Secure housing through mounting ears with appropriate fasteners (not included).
      If mounting housing to I-joist, use wood blocking as shown.
      All Installations
      All Installations

    12. Connect 4-in. round duct.
      All Installations

    13. Connect wiring.
      Connect power cable to housing with appropriate UL approved connector (not included). Make wiring connections as shown in “Wiring Diagram” section. Reinstall wiring panel and secure with screw from parts bag.

    14. Install blower.
      Re-install blower. Secure blower with (2) screws from parts bag and plug blower into black receptacle.
      All Installations

    15. Finish ceiling, then install grille.
      Attach MOUNTING PLATE to housing with (2) SCREWS, using the GRILLE BACKETS installed in step 4.
      Connect LIGHT PANEL PLUG to receptacle in corner of housing.
      Line up (3) STUDS on GRILLE FRAME with (3) KEYHOLE SLOTS on MOUNTING PLATE. Rotate GRILLE FRAME to secure in place.
      All Installations

WIRING DIAGRAM

Wiring Diagram

CUSTOMER SUPPORT

Broan-NuTone LLC, 926 West State Street, Hartford, Wisconsin, USA 53027 Broan-NuTone.com 800-558-1711

Register this product at broan.com, broan.ca, nutone.com or nutone.ca. For Warranty Statement, or to order Service Parts: go to the appropriate website and type the model number in the “Model Search” field.