Specifications
- Models: AE80K, AE80LK, AE110K, AE110LK
- Description: Fan, Fan with LED light
- CFM: 80 (AE80K, AE80LK), 110 (AE110K, AE110LK)
- Sones: 0.7 (AE80K, AE80LK), 1.0 (AE110K, AE110LK)
- Lighting: 11W Dimmable LED
- Features: TrueSealTM Damper Technology, EzDuctTM Connector, LED Lighting
Installation
The FlexTM Series fan offers versatile installation options for both new
construction and roomside retrofits.
- For new construction, use the FoldAwayTM Mounting Ears that are precisely positioned.
- For roomside retrofits, fold the mounting ears flat for easy installation.
- Use the EzDuctTM Connector for room-side installation without attic access.
Operation
The TrueSealTM Damper Technology reduces air leakage by up to 50% compared to
other models, leading to a better home performance.
The integrated LED lighting offers energy efficiency and longevity, lasting up
to 25,000 hours.
Maintenance
Regularly clean the CleanCoverTM Grille to maintain airtight performance.
FAQ
-
Q: Can the fan be used over bathtubs and showers?
A: Yes, the fan is U.L. Listed for use over bathtubs and showers when connected to a GFCI-protected branch circuit (ceiling mount only). -
Q: What is the warranty period for this product?
A: The product comes with a 3-year warranty.
Most flexible installation.
Most efficient operation.
Flexibility for new construction and roomside retrofit from one fan.
- EzDuct™ Connector enables roomside installation without attic access.
- 50% more airtight than standard ventilation fans to help meet rigorous codes and standards.
- Snap-fit Flange Kit will cover the edges of the cutout for a more professional finish and a tighter, leak-free seal.
- Provides a fresh, stylish grille design to complement any bathroom.
Versatile Installation. Airtight Performance. CleanCover™ Grille.
Flex™ Series gives professionals smart options for new construction or roomside retrofits in one, hard-working product line.
FoldAway™ Mounting
Ears are precisely positioned for new construction and fold flat for roomside
retrofits. Every installation can be handled more efficiently.
With our TrueSeal™
Damper Technology, Flex™ Series fans reduce air leakage by up to 50% compared
to competitive models*, resulting in better home performance via blower door
tests.
EzDuct™ Connector
enables roomside installation without attic access. Attach the housing, pull
the duct through, attach the EzDuct™ Connector and reset it with one screw.
LED Lighting offers greater energy efficiency and
longevity, and adds a unique design detail to this hard-working fan. 11-watt,
800 Lumens integrated LED module lasts up to 25,000 hours.
MODEL | DESCRIPTION | CFM | SONES | LIGHTING |
---|---|---|---|---|
AE80K | Fan | 80 | 0.7 | |
AE80LK | Fan with LED light __ | 80 | 0.7 | 11W Dimmable LED |
AE110K __ | Fan | 110 | 1.0 | |
AE110LK | Fan with LED light | 110 | 1.0 | 11W Dimmable LED |
- Testing reflects total fan housing air tightness. See Broan.ca for details.
MODEL AE110K FLEXTM SERIES FAN
DESCRIPTION
BLOWER
- Plug-in, permanently lubricated motor – engineered for continuous operation
- Dynamically balanced centrifugal blower wheel for quiet, efficient performance
- Low RPM for quiet operation
HOUSING
- Rugged, 26 gauge, galvanized steel construction
- Polymeric, 4” duct connector with tapered sleeve and no metallic clatter
- 5-3/4” height allows for 2” x 6” ceiling installations
- Sturdy, easy, four-point mounting directly to joist
- Can be mounted in ceilings up to 7/12 pitch
- Can be installed in a wall if mounted 8-ft. or more above the floor
GRILLE
- Polymeric construction
- Innovative design – the result of extensive research with designers and consumers
CONTROLS (Purchase separately)
Refer to Broan’s catalog for a complete line of accessories to effectively
adapt these fans to your construction requirements
U.L. Listed for use over bathtubs and showers when connected to a GFCI-
protected branch circuit (ceiling mount only)
U.L. Listed for use in insulated ceilings (TYPE I.C.) 3-Year Warranty
SPECIFICATION SHEET
TYPICAL SPECIFICATION
Fan shall be Broan Model AE110K.
Fan shall have corrosion-resistant galvanized steel housing with four-point
mounting capability. It shall be ducted to a roof or wall cap using 4” round
ductwork.
Blower assembly shall be removable, have a centrifugal-type blower wheel and a
permanently lubricated motor designed for continuous operation.
Non-metallic damper/duct connector shall be included.
Air delivery shall be no less than the airflow values and no greater than the
sound level values listed in the HVI Performance Specifications provided in
this specification (see following chart). All air and sound ratings shall be
certified by HVI.
Ceiling Ventilator shall be U.L. Listed for use in insulated ceilings (Type
I.C.) and for use over bathtubs and showers when connected to a GFCI protected
branch circuit.
Broan LLC Hartford, Wisconsin www.Broan-Nutone.com 888-558-1711
Venmar Ventilation ULC Drummondville (Quebec), Canada
www.Broan.ca 877-896-1119
PERFORMANCE RATINGS FLEXTM SERIES FAN
HVI PERFORMANCE
0.1 Ps – Static Pressure (in H2O) | 0.25 Ps |
---|---|
Airflow (CFM) | Sound (Sones) |
110 | 1.0 |
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements.
ELECTRICAL & WEIGHT
Volts | Hz | Amps | Shipping Weight |
---|---|---|---|
120 | 60 | 0.3 | 10.0 |
AIRFLOW PERFORMANCE
Roomside / FlexTM Series Fan
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
- Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
- Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
- Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
- Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
- When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
- Ducted fans must always be vented to the outdoors.
- Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit (ceiling installation only).
- This unit must be grounded.
For Warranty Statement, Service Parts, Technical Support, or to Register your
product, please visit our website or call:
In the United States – Broan-NuTone.com
800-637-1453 or 888-336-6151. In Canada – Broan.ca or
NuTone.ca 877-896-1119
CAUTION
- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
- This product can be installed in a wall if mounted 8-ft. or more above the floor.
- To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
- Please read the specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance –
lower or remove grille and vacuum interior of unit with the dusting brush
attachment.
The motor is permanently lubricated and never needs oiling. If the motor
bearings are making excessive or unusual noises, replace the blower assembly
(includes motor and impeller).
OPERATION
Use an on/off switch to operate the fan.
FlexTM Series Fan ONLY: Do not use a speed control.
IMPORTANT – The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
OPTION – To mount housing anywhere between ceiling framing: Use optional Hanger Bar Kit (sold separately from local distributors or website). Follow mounting instructions included with kit.
ALL INSTALLATIONS
-
Remove all packing material, unplug and remove blower from fan housing.
-
Remove wiring panel from fan housing (if already installed).
31 Some models only:Select 50, 80 or 110 -
CFM based on your room size and desired airflow.
-
Some models only:
A pair of flanges may be attached to housing if desired or required. Snap both flange pieces under the rolled-over edge of the housing (all four sides).
For Retrofit Installation – Skip to Page 3. -
Attach damper/duct connector Toto fan housing.
-
Mount housing to ceiling structure.
- Make sure bottom of housing will be flush with finished ceiling.
- For proper location using ½” ceiling material: Bend out housing tabs (on outside of housing) to fit against bottom of joist.
- Secure housing through mounting ears with appropriate fasteners. If mounting housing to I-joist, use wood blocking as shown.
-
Connect 4-in. round duct.
-
Connect wiring.
Connect power cable to wiring plate (from parts bag) using UL approved connector.
Connect house wiring to fan wiring. Refer to wiring diagram for connection details. Use screw (from parts bag) to secure wiring plate to fan housing. Re- install wiring panel and secure with screw from parts bag. -
Finish ceiling.
Then continue with Step 10.
RETROFIT INSTALLATION
Remove old fan and prepare ceiling.
Enlarge ceiling opening (if necessary) to 9¾” parallel to joist) by 10½”
(perpendicular to joist). (Some models have a cut-out template on side of
carton.)
Existing fan housings are typically attached to the structure
- with screws, nails, or staples, which must be removed.
- with hangers or rails which are fastened to joists and must be removed along with housing.
A pry bar may be needed to remove the old housing.
Leave ductwork and wiring in place.
Fold mounting ears flat against the
housing.
Connect wiring.
Connect power cable to wiring plate (from parts bag) using UL approved
connector. Connect house wiring to fan wiring. Refer to wiring diagram for
connection details. Use screw (from parts bag) to secure wiring plate to fan
housing. Re-install wiring panel and secure with screw from parts bag.
Mount fan-to-ceiling structure.
Mount housing to ceiling structure with appropriate fasteners in locations
shown.
Connect 4-in. round duct.
1 Pull existing ducting through housing discharge opening and 2 tape
ducting to duct connector. 3 Push connector/ducting back hrough opening.
Engage tabs and 4 secure with screw from parts bag.
ALL INSTALLATIONS
Install blower.
Re-install blower removed in Step 1. Secure blower with 2 screws from parts
bag. Plug blower into black receptacle.
FlexTM Series Fan ONLY : Plug 5-wire plug into controller module.
Install grille.
Squeeze grille springs and insert into slots in blower. Push grille up against
ceiling.
If grille spring becomes dislodged from grille snap it back into place as
shown.
Depending upon the model – your grille may look different.
WIRING DIAGRAM
References
- Broan-NuTone | Better Air. Better Life.
- Broan-NuTone - Residential exhaust ventilation and air quality products
- Broan-NuTone - Residential exhaust ventilation and air quality products
- Broan-NuTone | Better Air. Better Life.
- Broan-NuTone - Residential exhaust ventilation and air quality products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>