aqua computer OCTO Fan Controller Per Ventole Installation Guide
- August 21, 2024
- aqua computer
Table of Contents
- aqua computer OCTO Fan Controller Per Ventole
- Product Information
- Product Usage Instructions
- Electrical connections
- aquasuite software
- Overview pages (aquasuite)
- Data quick view and data log (aquasuite)
- Sensor configuration
- Fan configuration
- RGBpx configuration
- Alarm configuration
- Profiles
- System settings OCTO
- Playground (aquasuite)
- Aquasuite web
- Basic settings (aquasuite)
- Technical details and care instructions
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
aqua computer OCTO Fan Controller Per Ventole
Product Information
Specifications
- Brand: aquacomputer
- Model: OCTO
- Language: English
- Current Version: February 2024
Product Usage Instructions
Safety Precautions
Before using the OCTO, please read and follow all safety precautions
mentioned in the user manual to ensure safe operation.
Scope of Delivery
The OCTO package includes [list of items in the package]. Ensure all items
are present before proceeding with the installation.
Assembly Instructions
Follow the step-by-step assembly instructions provided in the user manual
to correctly set up the OCTO device in your system.
Electrical Connections
Refer to the electrical connections section for detailed guidance on
connecting OCTO to power sources and other devices.
aquasuite Software
Install the aquasuite software as per the instructions provided in the
manual to access additional features and functionalities of OCTO.
FAQ
-
Q: How do I update the aquasuite software?
A: To update the aquasuite software, visit the official aquacomputer website and download the latest version. Follow the installation instructions provided on the website. -
Q: Can I use OCTO with other aquacomputer products?
A: Yes, OCTO is compatible with other aquacomputer products.
Ensure proper configurations are set up for seamless integration.
Preface
The OCTO is an eight channel PWM fan controller with outstanding
functionality, equally suited for water cooled or air cooled computers.
In addition to the eight PWM fan outputs with speed signal monitoring, the
OCTO is equipped with four temperature sensor inputs, one flow sensor input as
well as USB and aquabus interfaces. As a special feature, an integrated RGBpx
effect controller for up to 180 individually addressable LEDs is included.
Considering the fast technical development, we reserve the right to perform
alterations to the products at any time. It therefore is possible that your
product does not correspond precisely to the descriptions or especially the
illustrations in this manual.
Safety precautions
The following safety precautions have to be observed at all times:
- Read this manual thoroughly and entirely!
- Save your data onto suitable media before working on your hardware!
- This product is not designed for use in life support appliances, devices, or systems where malfunction of this product can reasonably be expected to result in personal injury. Aqua Computer GmbH & Co. KG customers using or selling this product for use in such application do so at their own risk and agree to fully indemnify Aqua Computer GmbH & Co. KG for any damages resulting from such application!
Scope of delivery
- One OCTO controller
- One temperature sensor (replacement part no. 53026)
- One internal USB cable (replacement part no. 53215)
- Four screws M3 x 8 mm (replacement part no. 91032 or 91069)
- Four hex nuts M3 (replacement part no. 91017)
- Two screws M3 x 12 mm (replacement part no. 91003)
- Two plastic spacers (replacement part no. 91023)
- This manual
Assembly instructions
The OCTO controller can be installed inside the PC case using the supplied
screws and nuts. In order to access the mounting holes, bend the rubber
insulation away from the top cover of the OCTO controller and remove the top
cover. Reinstall the top cover afterwards. The longer distance between the
mounting holes matches 2.5 inch drives, enabling installation in 2.5 inch
drive bays or onto the bottom side of 2.5 inch drives. If necessary, remove
the rubber isolation completely and install with the supplied plastic spacers
instead.
Alternatively, double sided adhesive tape can be used to secure the OCTO
controller inside the PC case.
Make sure that the electric connectors do not have contact to metal parts or
other electronic devices inside the PC case, otherwise malfunctions or
destruction of the OCTO unit or other devices may occur!
Electrical connections
OCTO connector overview
ATTENTION: Completely turn off your power supply or disconnect the mains
power cord from the wall outlet before connecting or disconnecting any cables
to/from the device!
Connector “Power supply”
Please connect a HDD power plug of your PSU to this connector. Do not use
excessive force but double check the polarity of the plug if you are having
trouble to connect.
Pin assignment: Pin 1 +12 V
Pin 2 GND
Pin 3 GND
Pin 4 +5 V
Connector “Fan 1/2/3/4/5/6/7/8”
PWM regulated fan outputs with speed signal processing. The combined current
of all fan outputs must not exceed 8 A in total.
Pin assignment:
Pin 1: GND
Pin 2: 12 V / max. 2 A
Pin 3: Speed signal
Pin 4: PWM signal
Connector “USB”
This connector is used for USB communication with a PC. Connect to an
internal USB header of your motherboard. Take special care to make sure the
pin alignment matches your motherboard!
The corresponding connector on the motherboard is usually a 9 pin connector
with two independent USB ports. Both rows of 4/5 pins can be used to connect
an USB device. The black wires (GND) are to be connected to the side of the
missing pin, see picture with colored pin assignment.
Pin assignment:
- Pin 1 +5 V (red)
- Pin 2 D- (white)
- Pin 3 D+ (green)
- Pin 4 GND (black)
- Pin 5 not connected
Connector “aquabus”
Connector for communication with other Aqua Computer devices. USB and
aquabus interface can be used at the same time.
Pin assignment:
- Pin 1 GND
- Pin 2 aquabus SDA
- Pin 3 aquabus SCL
- Pin 4 +5 V
Compatible aquabus devices:
- aquaero 6 XT (53146, 53206, 53250, 53251, 53262, 53263)
- aquaero 6 PRO (53145, 53253)
- aquaero 6 LT (53234)
- aquaero 5 XT (53089, 53125, 53249)
- aquaero 5 PRO (53090, 53252)
- aquaero 5 LT (53095)
Connector “flow sensor”
Flow sensor and special interconnecting cable are optional accessories and not
included in delivery.
Pin assignment:
- Pin 1 GND
- Pin 2 flow sensor +5 V
- Pin 3 flow sensor signal
Compatible flow sensors:
- Flow sensor high flow LT (53291)
- Flow sensor high flow 2 (53292)
- Flow sensor with 5.6 mm nozzle (53061)
- Flow sensor “high flow” (53068)
- Connection cable flow sensor for VISION (53212)
Connector for temperature sensors
Connector for up to four temperature sensors. Compatible sensors:
- Temperature sensor inline G1/4 (53066)
- Temperature sensor inner/outer thread G1/4 (53067)
- Temperature sensor G1/4 (53147)
- Temperature sensor plug&cool (53025)
- Temperature sensor 70 cm (53026)
Connector “RGBpx 1/2”
Connectors for up to 90 addressable LEDs each. Compatible LED products and
special interconnecting cables are optional accessories and not included in
delivery.
If the RGBpx product to be connected has more than one RGBpx connector, the
connector marked with the word “IN” must be used! Additional RGBpx products
may be connected to the “OUT” connector.
Compatible RGBpx products:
- RGBpx LED-Strip (53268, 53269, 53270)
- RGBpx lighting set (53271, 53272)
- RGBpx Splitty4 (53267)
- RGBpx Splitty12 ACTIVE (53300)
- RGBpx LED ring for ULTITUBE (34115)
- RGBpx LED ring for aqualis (53274, 53276)
- RGBpx LED ring for 60 mm reservoir (53277)
- RGBpx cable (53259, 53260, 53261, 53266, 53297)
Connector “signal”
The signal output can be connected to the power switch header of the
motherboard using an additional specialized cable (53216, not included in
delivery).
Pin assignment:
- Pin 1: open drain max 3.3 V / 5 mA
- Pin 2: do not connect!
- Pin 3: open drain max 3.3 V / 5 mA
Status LED
The red status LED is continuously on for approximately ten seconds during
startup and then turned off during normal operation. The status LED is
blinking during
error conditions, for example after fan output deactivation due to overload or
faulty supply voltage. In case of errors, RGBpx LEDs connected to the device
will be blinking in red, disregarding the current LED controller setup.
aquasuite software
The Windows software aquasuite is an extensive software suite and can be used for configuration and monitoring. The software is not required for operation though. All configuration parameters can be saved into the device’s memory. Please note: Depending on the type of product you are using, some features may not be available for your device.
Installation of the aquasuite software
For configuration and monitoring of our products with USB interface, the
aquasuite software is available for download from our website www.aqua-
computer.de. You will find the setup program in
the support section of the website under Downloads/Software.
The setup program checks all connected USB devices for embedded update service
periods and offers various aquasuite versions depending on detected devices.
If no device with update service for the latest aquasuite version is found, a
warning is displayed and older aquasuite versions that do not require an
update service purchase can be selected for installation. For installation and
update service validation, an internet connection is required.
The latest aquasuite version may also be installed if no suitable update
service period has been found in a device. Subsequently, update service may be
purchased or an existing key may be entered within the aquasuite. These
functions can be accessed in the aquasuite/Updates tab.
Basic operation
The program window is divided into two main areas. On the left side, a list
of “overview pages”, data quick view, data logger, device pages, aquasuite web
and aquasuite configuration is displayed, the right side shows the details of
the currently selected list element. The list can be hidden or restored by
clicking the arrow symbol in the upper left corner.
List elements may be minimized or maximized for easier access by clicking the
title bar. The title bars may contain various symbols that will be explained
in the
following chapter.
Symbols in the headlines
Click the plus symbol in the “Overview pages” headline to create a new
overview page.
Clicking the monitor symbol will toggle desktop mode for this overview page.
While desktop mode is active, the color of the symbol will change to orange.
Overview page: Clicking the padlock symbol will unlock or lock this over-view
page for editing. Device: Device can not be used due to update service
problems, see “Updates and update service” for details.
Clicking the gear symbol will access the basic configuration page of the
selected list element.
In order to save all settings into a device, click the disk symbol in the
headline.
This symbol indicates that communication with this device is not possible at
the moment. Check USB connection and power supply of the device if necessary.
Overview pages (aquasuite)
Current sensor readings and diagrams from all supported devices can be displayed in overview pages. For each device a pre-configured overview page is automatically generated the first time the device is connected to the PC. These pages can be individually modified and new pages can be created. Within one overview page, data from all connected devices can be accessed.
Desktop mode
Each overview page can be displayed directly on your desktop. You can enable
desktop mode for an overview page by clicking the monitor symbol in the list
of overview pages. Desktop mode can only be enabled for one overview page at a
time. With desktop mode enabled, elements of the overview page may cover
program symbols on your desktop, but mouse clicks are transmitted to
underlying desktop symbols.
If a overview page is unlocked for editing while desktop mode is active, the
page will be displayed in the aquasuite window for editing and the current
desktop will be displayed as background for your convenience.
Creating new overview pages and activating edit mode
In order to create a new overview page, click the plus symbol in the
headline “Overview pages”.
Existing overview pages can be unlocked for editing by clicking lock symbol in
the page listing.
Adding new elements
If the currently selected overview page is unlocked for editing, a plus
symbol is displayed in the top right corner of the screen. Click the symbol to
add a new element to the page and select the desired element from the
following list. All available data is displayed in a tree diagram, click the
arrow symbols to access individual items.
Confirm your selection by clicking the check symbol in the bottom right
corner. The new element will be displayed in the upper left corner and the
configuration window is displayed. Configure the element as described in the
next chapters.
Editing existing elements
If the currently selected overview page is unlocked for editing, right-
clicking an element will access a context menu.
To access the settings of an element, select “Settings” in the context menu or
simply double click the element. If you want to move an element, “drag” this
element while holding down the mouse button. Release the mouse button when the
element is at the desired position.
Values and names
If the currently selected overview page is unlocked for editing, right-click
an element and select “Settings”. You may also double click the element.
Font face, size and color as well as position, decimal places and unit can be
configured for individual values.
Detailed data elements
If the currently selected overview page is unlocked for editing, right-click
an element and select “Settings”. You may also double click the element. Apart
from position, size and color, the style of the element can be selected and
configured.
The following styles are available:
- Headline only: Compact display as a headline.
- Text: Displays the numerical value in a box with a headline.
- Bar graph: Displays numerical value as well as bar graph.
- Chart: Displays the value in chronological sequence as a chart.
- Gauge: Displays the value as a analog gauge.
All display styles offer extensive configuration options, additionally statistical data such as minimum, maximum and average can be displayed.
Log data chart
This element can be used to display charts on overview pages. The charts have
to be created using the data log functionality of the aquasuite before they
become available for overview pages. Please refer to the next chapter for
details. Once a chart has been configured, it can be selected from the “Chart
selection” list on the “Display” tab of the settings dialog.
User defined: Images, text, drawing elements
By using user defined controls, simple drawing elements such as circles,
rectangles and texts as well as images and more sophisticated elements can be
added to an overview page. To do so, add an “User defined” element to an
overview page. Switch to the “Display” tab in following dialog box, select the
type of element to be created from the drop down menu and confirm your
selection by clicking the “Load preset” button. Depending on the type of
element, an additional dialog may appear before the code (XAML, Extensible
Application Markup Language) of the new element is displayed in the lower part
of the dialog window. You may want to customize the code. By clocking the “Ok”
Button, the new control is saved to the overview page.
Step-by-step example to add an image: Select “Image” from the drop down menu
and click the “Load preset” button. Select an image file using the following
file
selection dialog. The code is then displayed in the lower part of the dialog
window an can be modified. Save the new control by clicking the “Ok” button.
The picture will be displayed on the overview page.
More complex controls such as data bindings and animations are also available
but will require some programming experience for configuration.
Export and import of overview pages
Elements and complete overview pages can exported from the aquasuite and can
then be imported either on the same PC or on other PCs. For export as well as
import, the overview page must be in edit mode.
To export a complete page, right click a free spot of the page and select
“Export page” from the context menu. To export individual elements, select the
element or elements, perform a right click and select “Export selected” from
the context menu. For import, right click a free spot of the page and select
“Import page” or “Import items”from the context menu. Using “Import page”, the
current page will be deleted and only the imported page items will be
displayed, using “Import items” will add the items from file to the current
page without altering the existing items.
During import, the elements will be assigned to devices using the following scheme:
If a device with identical serial number is found on the computer, no changes
are made.
If no device with identical serial number is found on the computer, the
element will be assigned to the first device found of identical type.
When importing complex pages with elements referring to more than one device,
it is recommended to edit the device assignment in the file using a text
editor prior to importing.
Data quick view and data log (aquasuite)
All data currently monitored by the aquasuite can be accessed in the “Data
quick view” section. This includes data from connected USB devices as well as
hardware data supplied by the Aqua Computer background service. Displayed data
may be filtered using the text box next to the magnifier icon, a chart shows
the development over a maximum of ten minutes. All data shown here is not
stored permanently.
In contrast, the “Data log” may be used to selectively and permanently store
data from all connected Aqua Computer devices and hardware data supplied by
the background service. Logged data can then be analyzed by creating charts or
be exported to files. Data is only logged while the aquasuite software is
being executed.
Log settings
The log settings can be accessed by clicking the “Log settings” element
below the “Data log” headline in the listing. To log data, create a new log
data set by clicking the plus symbol in the upper right corner of the settings
window. Enter name, time interval and configure automatic deletion of old data
to meet your requirements. You may then add the data sources to log by
clicking the plus symbol in the “Data sources” window section. You may add an
unlimited number of data sources to each log data set, the total number of log
data sets is also unlimited.
Analyze data
Logged data can be visually evaluated as charts. To do so, select “Analyze
data” below the “Data log” headline in the listing. The chart will initially
be empty, directly below the chart are eight buttons to modify the chart. In
the lower section of the window, the chart data can be configured. To add data
to the chart, first select the “Data sources” tab in the chart configuration
and select a data set to be displayed. If no data sources are available, you
will have to configure the log settings as described in the chapter “Log
settings” of this manual. Select the time period to be displayed on the right
side of the window and add the data to the chart by clicking the “Add data to
chart” button. Repeat this procedure if you want to display more than one data
set in the chart.
You may modify the chart using the “Chart setup” and “Data series setup” tabs.
Finally, you can use the “Chart manager” tab to save the current chart
configuration and to load or delete previously saved configurations. All saved
chart configurations will be available on overview pages for the “Log data
chart” element.
The currently displayed chart can be edited by using the buttons directly
below the chart and may also be saved as an image file. The button
corresponding to the currently selected function is highlighted by an orange
frame. Please refer to the following list for details on each function:
To save the currently displayed chart as an image file, click the floppy disk
symbol and select a name and location in the following dialog.
This function can be used to add horizontal lines to the chart. While this
function is activated, simply click into the chart to add a line at the
current cursor position.
This function can be used to add vertical lines to the chart. While this
function is activated, simply click into the chart to add a line at the
current cursor position.
This function can be used to add annotations to the chart. While this function
is activated, simply click into the chart to add an annotation at the current
cursor position. By clicking into the text box, you may edit the text. You may
also drag the little circle beside the text box to move the connecting line to
the desired position. Use drag and drop to move existing annotations.
This function can be used to remove horizontal/vertical lines or annotations
from the chart. While this function is activated, simply click the element to
be removed.
This function can be used to move the visible portion of the chart. Press and
hold the mouse button while moving the cursor in the chart to select the
position to be displayed, then release the button.
This function can be used to zoom in and out. Use the mouse wheel or select
the area to be displayed. You can reset the zoom settings by double-clicking
in the chart area.
This function can be used to reload and update the chart.
This function will completely remove the chart.
Manual data export
Saved data can be exported from the data log into a XML file. To do so, select
“Analyze data” below the “Data log” headline in the listing. Select the “Data
sources” tab in the chart configuration and select a data set to be exported.
If no data sources are available, you will have to configure the log settings
as described in the chapter “Log settings” of this manual. Select the time
period to be exported on the right side of the window and start the export
process by clicking the “Export data” button. Enter a file name and path in
the following dialog window.
Automatic data export
The automatic data export feature can be used to save data from the
aquasuite into an XML file on the hard disk or in the RAM (“memory mapped
file”) in a regular time interval. The automatic data export will always
overwrite the previously saved data, so the file always contains only the most
recent data set. Select “Automatic data export” below the “Data log” headline
in the listing to access the settings screen. Create a new export data set by
clicking the plus symbol in the upper right corner of the screen. Enter name,
path and time interval to meet your requirements. You may then add the data
sources to log by clicking the plus symbol in the “Data sources” window
section. You may add an unlimited number of data sources to each export data
set, the total number of export data sets is also unlimited.
Sensor configuration
Select “Sensors” from the device list below the “OCTO” entry. In the upper area, the twenty-one available sensors are displayed including current data. In the lower area, the currently selected sensor can be configured.
Hardware temperature sensor
The first four sensors in the list represent the temperature sensor inputs of
the OCTO.
If necessary, each temperature sensor can be calibrated by adding an offset
of±15 °C.
Hardware flow sensor
The fifth sensor in the list represents the flow sensor input of the OCTO.
Calibration values for sensors sold by Aqua Computer can conveniently be
selected from a drop-down list. Select the appropriate entry for the flow
sensor connected to the OCTO.
If necessary, the flow rate can be calibrated by ±10 %.
Software sensors
The last sixteen sensors in the list are software sensors and can be used to
transmit sensor data that is not physically available to the OCTO controller
from the
computer by USB connection. During installation of the aquasuite, the
background service “Aqua Computer Service” is also installed. This service
supplies various data from PC components and imported data from aquasuite web,
additionally sensor data provided by third party software can be accessed. In
order to access third party software data, the third party software has to be
correctly installed, configured and running.
Currently, the “Aqua Computer Service” supports data transfer from “HWiNFO”
(REALiX, Freeware, www.hwinfo.com) and “AIDA64”
(FinalWire Ltd., subject to
license fees, www.aida64.com).
In the HWiNFO settings menu, “Shared Memory Support” must be activated and the “Sensor Status” window has to be open:
In the AIDA64 preferences menu, “Enable shared memory” must be activated in the “External Applications” sub-menu:
By clicking the plus symbol labeled “Data source”, one of the provided sensors
can be assigned to the selected software sensor.
For each software sensor, a scale factor and an offset may be configured for
manipulation of the displayed sensor value. Data from third party software
regularly requires the scale factor to be adjusted.
Fan configuration
Select “Fan” from the device list below the “OCTO” entry. All available fan outputs will be displayed in the upper region of the page. Click on any element to display and edit the configuration for this fan output.
Fan mode power preset
If power preset mode is selected, you can manually set the desired output
power of the fan output.
Fan mode temperature set point
This mode can be used to automatically adjust fan speed depending on the
current temperature reading of one of the up to nine available temperature
sensors. The desired target temperature can be configured, all other
parameters should not be changed for normal operation.
Fan mode curve controller
This mode can be used to automatically adjust fan speed depending on the
current temperature reading of one of the up to nine available temperature
sensors. The controller curve can be configured by assigning output values to
16 corresponding temperature values.
The output value in percent corresponding to the current temperature is scaled
to the range between minimum and maximum fan power settings before being
applied to the fan output.
The startup temperature will also be factored into the controller output. The
output power defined in the curve controller will be ignored and set to 0 % as
long as the input temperature has not exceeded the defined startup temperature
for the first time. After the startup temperature has been exceeded, the
output will strictly be set according to the defined curve until the output
value goes down to 0 % again. This will trigger the startup process again,
meaning the temperature has to exceed the defined startup temperature again
before the curve will be in effect once more. This behavior is meant to
prevent fans assigned to the curve controller to be switched on and off in
rapid succession. If the first point on the curve is set to a power greater
than 0 %, this behavior is deactivated.
In the aquasuite, controller curves can easily be adjusted using drag & drop
and curves can automatically be generated from start and end points. In the
graphical curve display, the currently displayed area can be changed using the
following methods:
- Mouse wheel movements will zoom in and out.
- A double click on an axis will reset zoom level for this axis, a double click into the diagram will reset both axes.
- Selecting an area on an axis will zoom this axis to this area, selecting an area in the diagram will zoom both axes to this area.
- Mouse movement while right button is pressed will move the displayed area of the diagram.
General fan settings
Depending on currently selected fan mode, additional parameters can be
configured.
The start boost feature can be used to reliably power up a fan or pump
connected to the output. If activated, the controller will set the fan output
to the 100 % power for a short duration before switching to normal operation
whenever the output power changes from exactly 0 % setting to a higher value.
The fan output range can be limited by setting “Minimum power” and ”Maximum
power” values correspondingly. The check box “Hold minimum power” determines
whether the fan will be switched off during a power setting of 0 % (box not
checked) or remain active at the set minimum speed (box checked). Set minimum
power to a value at which the connected fan reliably starts up. The “Maximum
fan speed for bar graph and chart” setting applies only to diagram scaling
within the aquasuite and has no effect on the fan output.
Fan behavior with aquabus connection to an aquaero
As soon as an aquabus connection between the OCTO and an aquaero 5/6 is
established, the fan output is solely controlled by the aquaero. All settings
in the OCTO regarding fan function will be ignored. Only if aquabus is
disconnected, the settings in the OCTO will be used for controlling the fan
output again.
RGBpx configuration
Select “RGBpx” from the device list below the “OCTO” entry.
In the RGBpx overview, select the RGBpx output to be configured.
After selecting a RGBpx output, new LED controllers can be added. Position and
number of assigned LEDs can be modified for existing LED controllers,
controller settings can be modified.
Create and configure additional LED controllers
After selecting a RGBpx output, new LED controllers can be added by clicking
the plus symbol. Alternatively, use the right mouse button and select “New”
from the context menu. Select the desired effect from the superimposed list of
available effects. The controller name can be altered from its default as
well. Confirm you selection by clicking the check symbol in the lower right
corner.
The configuration of the newly added LED controller can be modified in the
lower area of the window. Each LED controller can activated or deactivated for
each of the four available profiles as well. Most effects offer extensive
customization options such as color selection or speed adjustment.
Additionally, many effects can be configured to modify effect parameters
depending on current sensor data.
In total, up to 6 LED controllers can be configured for each output.
Modify existing LED controllers
Existing LED controllers can be selected by clicking the corresponding
color bars, the configuration of the selected controller can then be modified
in the lower area of the window.
By clicking the gear symbol, the effect to be displayed can be changed and the
controller name can be altered. Confirm you selection by clicking the check
symbol in the lower right corner.
Modify LED assignments
Existing LED controllers can be moved by using “drag&drop”on the
corresponding color bars. The position of the color bar defines the position
of the effect on the connected LEDs. Controllers positioned further up in the
list have higher priority than controllers further below.
The length of the bar (corresponding to the number of LEDs assigned) can be
changed by moving the right/left edge of the color bar.
Duplicate LED controllers
Select the LED controller(s) to be duplicated and click the duplicate
symbol to create new LED controllers using identical configurations.
Alternatively, use the right mouse button and select “Duplicate” from the
context menu.
These duplicated controllers will initially have configurations identical to
the original controllers, but can be modified without affecting the original
controllers.
In total, up to 6 LED controllers can be configured for each output.
Delete LED controllers
Select the LED controller(s) to be deleted and click the delete symbol to
delete the selected controllers. Alternatively, use the right mouse button and
select “Delete” from the context menu.
Sound controlled effects
Sound controlled effects can be used to visualize the current audio output of
the computer. A warning in the LED configuration area will notify you if audio
analysis has been disabled in the aquasuite. In this case, please enable the
feature in the general aquasuite configuration. The general aquasuite
configuration can also be used to modify existing audio filters and define
custom audio filters.
AMBIENTpx effect
The AMBIENTpx effect replicates the border area of the current monitor content
on the configured LEDs. This effect is meant to be used with LED strips
installed to the rear of the monitor for background lighting. A warning in the
LED configuration area will notify you if video analysis has been disabled in
the aquasuite. In this case, please enable the feature in the general
aquasuite configuration.
For each configured AMBIENTpx effect, please select the correct monitor, edge
and desktop range to evaluate for the effect.
Prerequisites and limitations:
- The AMBIENTpx effect requires Microsoft Windows operating system version 8.1 or newer.
- Screen content preventing analysis by DRM or similar methods cannot be analyzed.
- Multi monitor setups must be configured using standard procedures of the operating system. Special features of the graphics card driver like “NVIDIA Surround” or “AMD Eyefinity” must be disabled.
- AMBIENTpx is not available while “NVIDIA G-Sync” is active.
Alarm configuration
Select “Alarms” from the device list below the “OCTO” entry.
Signal output configuration
The signal header can be configured as a speed signal output or as a switching
output.
Option “Power switch (53216)”: This mode can be used for emergency shutdown of
the PC, if the “signal” header is connected to the power switch header of the
motherboard using a suitable cable (art. 53216). Before connecting the cable,
make sure the signal output is configured correctly! After connecting the
cable, test the setup by deliberately creating an alarm condition. If the PC
is not shut down, the cable header connected to the motherboard must be
rotated by 180 degrees and the test has to be repeated. Emergency shutdown may
result in data loss as operating system and running programs are not shut down
properly!
Alarm reporting and alarm limits
Select the data sources to be monitored and set appropriate alarm limits. If
the current reading is below the limit (flow sensors) or higher than the limit
(temperature sensors), an alarm will be raised if the check box “Activate
alarm evaluation” is set for this value.
On the alarm page within the aquasuite, all sources that currently raise an
alarm are highlighted with a red background color. Alarms that have been
active at least once since device start-up, but are not active presently, are
highlighted with a yellow background color.
Make sure only to use readings for alarm evaluation that are functional with
your specific setup.
Profiles
Select “Profiles” from the device list below the “OCTO” entry.
The profile management can be used to to save four configurations as profiles
and activate them manually or automatically. Profile management is a software
feature of the aquasuite and requires a USB connection to the OCTO.
Manual profile selection
Select the profile to be activated by clicking the corresponding button.
Automatic profile selection
Profiles can be activated automatically using the global profiles feature of
the aquasuite, see chapter 15.4. for details.
Profile configuration
All contiguration changes are automatically stored in the currently active
profile.
The current configuration can also be stored in any other profile by clicking
the corresponding button.
System settings OCTO
Select “System” from the device list below the “OCTO” entry.
Device information
The details displayed here might be required when you contact our service
for support. You may enter a “Device description” for easier identification,
this text will be displayed in the device list and in the data quick view.
Factory defaults
Click the button “Reset device to factory defaults” in the aquasuite or select
the “Factory defaults” entry from the menu for a complete reset of all
settings. You will have to completely reconfigure the device after resetting
it to factory defaults!
Basic RGBpx settings
Both RGBpx outputs can be completely disabled and the brightness of both
outputs can be adjusted using a slider.
Firmware update
The most up to date firmware for all supported devices is always included in
the current version of the aquasuite software. The button ” Update firmware
now” will start the update process for the device firmware. During the
firmware update process, do not disconnect the device from the PC and do not
power down the PC! After the firmware is successfully updated, the aquasuite
software will be automatically closed.
Playground (aquasuite)
Click the entry “Playground” to configure Virtual Software Sensors, global profile management and hotkeys.
Input values
Input values defined in this section can be manipulated by individually
configured control elements, for example sliders or buttons.
Create a new input value by clicking the plus symbol in the upper right corner
of the “Input values” window and configure the properties as desired. A name,
an icon, a unit, a range of values as well as a initial value can be assigned
to each input value. This new input value will then be available to be
displayed on overview pages and in the quick view section and can be used as a
data source for software sensors and virtual software sensors.
In the lower area of the window, control elements can be created and
configured to manipulate the input value. These preconfigured control elements
can then be used for overview pages or in the system tray.
Virtual Software Sensors
Virtual Software Sensors can be used for extensive yet easy to use adaptation
and calculation of sensor values using mathematical and logical functions as
well as filters.
Create a new Virtual Software Sensor by clicking the plus symbol in the upper
right corner of the “Virtual Software Sensors” window. Each Virtual Software
Sensor
always has an “Out” element which will provide the resulting sensor value. In
the settings dialog of this element, the name and unit of the sensor can be
configured. You can now add data sources and function blocks to the lower area
of the sensor window and connect inputs and outputs of the blocks with lines.
Connect the out-put of the last function block with the “Out” element.
The resulting virtual sensor can be used within the aquasuite software, for
example for overview pages, additionally it may be transmitted via USB
connection to
connected devices that feature software sensors.
The following (very simple) example calculates the average out of two temperatures:
Virtual software sensors are updated once per second and re-calculated with the numbers valid in that particular moment. When using fast changing input values, extreme values can therefore either be used or ignored for the calculation. No smoothing or averaging is taking place.
Output actions
While the virtual software sensors are used as a value within the aquasuite,
output actions configured in this section are used to trigger events. Various
notification events including emails and MQTT messages are available.
Additionally, external programs can be started.
Create a new output action by clicking the plus symbol in the upper right
corner of the “Output actions” window and configure the properties as desired.
Each output action always has an “Output” element which represents the event
itself. In the settings dialog of this element, the event to be executed can
be selected and configured.
You can now add data sources and function blocks to the lower area of the
window and connect inputs and outputs of the blocks with lines. Connect the
output of the last function block with the “Output” element. The event will be
executed when the input of the “Output” element reaches a value greater than
zero. Output actions are updated once per second and re-calculated with the
numbers valid in that particular moment. When using fast changing input
values, extreme values can therefore either be used or ignored for the
calculation. No smoothing or averaging is taking place. Example: If thresholds
are exceeded for very short periods of time lasting less than one second, the
action can be executed or not be executed seemingly at random, depending on
whether the thresholds is exceeded in the exact moment the calculation is
performed.
Global profiles
The global profile management can be used to conveniently change settings
in multiple devices simultaneously and activate desktop pages. Individual
actions can be defined for each of the four profiles, switching between
profiles can either be done manually or automatically depending on
configurable rules.
In order to use this feature, set up profiles within the individual device
configurations first. These profiles can then be activated using the global
profile management. Not every type of device supports profiles.
Buttons in the upper window area can be used to switch between global
profiles. Alternatively, the profile icon in the title bar of the aquasuite
window or a profile icon in the system tray may be used.
Example use cases: Switching of LED illumination settings depending on current
time of day or modification of fan settings when a graphics application is
launched.
Notice for profile activation depending on running applications: During
configuration of the respective rule in the aquasuite, the application to be
configured must already be running. The application selection within the
aquasuite will always show currently running applications and processes only.
Hotkeys
Hotkeys are key combinations that will be processed system-wide and can
activate global profiles or desktop pages. The configured key combinations
will be registered in the operating system and be processed by the background
service. If the configured actions only use the profile management, the
aquasuite does not have to be running for hotkeys to be operational; if
desktop pages are used, the aquasuite must be running.
Do not use key combinations for this function that are required by other
applications.
Aquasuite web
Click the entry “aquasuite web” to publish data on the internet or import data from the internet. The server for this service is operated by Aqua Computer and provided for use with the aquasuite, without warranty for error free operation or permanent availability. Aqua Computer reserves the right to limit or cancel this service at any time.
Data export
To publish data, create a new export data set by clicking the plus symbol in
the upper right corner of the “Data export” window. The name of the data set
may be modified to meet your requirements. You may then add the data sources
to export by clicking the plus symbol in the “Data sources” window section. By
clicking the gear symbol, the name of the corresponding value can be changed.
Up to 30 data sources can be added to each export data set, the total number
of export data sets is limited to 10. All selected values will be transmitted
to the Aqua Computer server by the Aqua Computer background service
approximately every 15 seconds, even after closing the aquasuite.
Notice regarding data security: All data contained in the configured export
data sets is transmitted to the Aqua Computer server with transport security.
The server stores the data set in volatile memory until a new data set is
received or until 10 minutes have passed. Data received is not permanently
stored, data is also not correlated to IP addresses or other personal data.
Data on the server may be accessed by anyone without restrictions, furthermore
automatic data collection and recording through third parties is possible. Use
the data export feature for data that you want to publish publicly and are
allowed to do so only.
Data access
Published data can be obtained from the Aqua Computer server in various
formats. Generally, the “access key” is required to access data. In addition
to access through any internet browser and importing data into the aquasuite,
data is also available in JSON format and compatible to Circonus. Furthermore,
the server generates banner images in two different sizes from the transmitted
data, suitable to be included in forums signatures. The code required for the
Aqua Computer forums is provided for your convenience.
Data import
To import a data set from the Aqua Computer server, the “access key” of the
data set is required. The access key can be found in the aquasuite on the
computer providing the data in the “Data access” section. Create a new import
entry by clicking the plus symbol in the upper right corner of the “Data
import” window. Enter the access key of the data set to be imported. Up to 10
data sets (each containing up to 30 values) can be configured.
In order to verify that data is being imported, use the “Data quick view”
feature in the aquasuite. Navigate to “Data from Aqua Computer service”, then
“aquasuite web”. For each imported data set, you should find an entry with the
name of the data set containing the individual values. It may take a few
seconds before imported data is displayed.
Basic settings (aquasuite)
Click the entry “Settings” below the headline “aquasuite” to access basic settings for language, units and start-up of the software.
Language
Select a language from the drop down menu. After changing the language
setting, the software will have to be restarted.
Create overview pages
After activating the “Generate device overview pages”, new overview pages with
default settings will be created for all devices.
Reorder menu items
The order in which overview pages and devices are displayed in the list can be
adjusted to you preference. Activate the reorder mode by clicking the “Edit
menu order” button or by clicking and holding one of the elements for a few
seconds. Sort the list items by clicking the arrow symbols and exit the
reorder mode by clicking the check symbol on the right side of the window when
done.
Units
Select the units to be used for temperature and flow values from the drop down
menus. After changing these settings, the software will have to be restarted.
Event log
Events from various parts of the aquasuite can be saved to text files. Use the
buttons to view the files either internally in the aquasuite or with an
external program.
Application start-up
You may customize start-up behavior to suit your preferences. You may also
select to hide the task bar symbol of the software when minimized.
Service administration
The background service configures special USB settings for all connected Hs
Aqua Computer devices, provides hardware data, software sed rerefree file
management, aquasuite web and Playground and should therefore always be
active. The hardware monitoring features of the background service can be
disabled for specific categories if errors occur. Especially when using
hardware monitoring software of different manufacturers at the same time,
conflicts can occur when accessing data. Deactivate the hardware monitoring
feature of the aquasuite or parts of it in this case.
When maintenance mode is activated, all optional modules of the background
service are deactivated. This is useful in case of erroneous settings in the
Play-ground, in particular if a system shutdown is configured and triggers too
often. Therefore, in default configuration maintenance mode is automatically
enabled if the computer is shut down three times by this feature (recommended
setting).
Audio and video
The background service can analyze audio and video data and provide it to
connected devices. Both functions can be enabled and disabled separately.
Notices for video analysis: Screen content preventing analysis by DRM or
similar methods cannot be analyzed. If a graphics card is configured for
variable refresh rate or a modified refresh rate, video analysis may fail;
please deactivate this function in the graphics settings of the operating
system if necessary.
Updates and update service
For software activation, all aquasuite versions starting with version 2017
require an active update service for the initial release date of the
respective version. Update service periods are generally assigned to
individual devices, brand-new devices automatically contain update service for
a specific period depending on the type of the device. For software
activation, at least one device in the computer must contain a corresponding
update service period that includes the release date of this software version.
If a valid update service period is detected for at least one device, all
devices connected to the computer can be used with this version. It is not
mandatory that each device has a corresponding update service period. For
update service validation, the aquasuite requires an internet connection.
After successful validation, a file containing current data is stored on the
computer. A re-validation is performed only if a new software version (update)
is installed or upon connection of new devices. New devices can not be used
prior to re-validation, even if other devices with corresponding update
service periods are connected at the same time.
To purchase update service, please use the “Buy” button, which will open a
website with current prices and payment options. If you have received a key
for update service with a device or bought one separately, you may enter the
key after clicking the “Register” button. Select a currently connected USB
device from the list for update service assignment. After clicking the
“Register key” button, the update service period is permanently assigned to
the selected device and stored on the Aqua Computer update server. The key
will not have to be re-entered after re-installation of the software or
transfer of the device to another computer, but transferring the update
service period to another device is not possible.
During update service validation and software activation, device serial
numbers and a calculated computer ID are transmitted to and stored on the
update server. No further personal information such as IP addresses are
stored.
E-mail and MQTT accounts
Accounts for sending e-mail or MQTT messages can be configured. These accounts
can then be used to send messages in the “Outputs” section of the Playground.
Technical details and care instructions
Technical details
Power supply: 12 V DC +5 %, max. 8 A
5 V DC + 5 %, max. 6 A
Dimensions: 76 x 48 x 17 mm
Ambient temperature range: 10 to 40 °C (noncondensing)
Care instructions
Use a dry and soft cloth for cleaning. All electronic components and headers
must not get in contact with coolant or water!
Waste disposal
This device has to be disposed of as electronic waste. Please check your local
regulations for disposal of electronic waste.
Contact Aqua Computer
We are always happy to answer questions regarding our products and to receive
feedback. For answers on frequently asked questions, please also check our
website www.aqua-computer.de. You might also
want to visit our forums and discuss our products with experienced moderators
and thousands of members – available
24/7. To get in direct contact with our customer support team, we offer
several options:
Email: support@aqua-computer.de
Postal address: Aqua Computer GmbH & Co. KG
Gelliehauser Str. l
37130 Gleichen
Germany
Tel: +49 (0) 5508 97 49290 (9-16 h CET, German and English language)
Aqua Computer GmbH & Co. KG
Gelliehauser Str. l, 37130 Gleichen
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>