PuriSystems HEPA Pro UVIG Air Scrubber Owner’s Manual

June 3, 2024
PuriSystems

HEPA Pro UVIG Air Scrubber
Owner’s Manual
PuriSystems HEPA Pro UVIG Air Scrubber

READ AND SAVE THESE INSTRUCTIONS
WARNING!

Please note that the Purisystems HEPA Pro UVIG should only be used with parts approved by Purisystems.The use of unauthorized parts or alterations to the machine could void your warranty.Contact an approved distributor for further assistance.

SAFETY NOTES

To Avoid the Risk of Fire or Electric Shock:

  • The unit must be electrically grounded.
  • This machine is forbidden to stack and does not place heavy objects on the power cord.
  • Please check the power cord for damage (wear, cuts, etc.) before use.
  • Please check if the filter is damaged before use.
  • Do not touch the product with wet hands.
  • Before plugging the power cord into the power outlet, turn off the power switch on the unit.
  • When water enters the machine, pull out the power plug and completely dry the machine before use
  • Unplug the power plug during thunder or thunderstorms.
  • Do not place this product in a humid place. Otherwise, there may be a risk of electric leakage or electric shock.
  • Do not install it in a place with combustible gas. There will be the risk of explosion.
  • Please clear any obstructions on the air inlet and outlet before use.
  • When cleaning the surface of the unit, please unplug the power cord and wipe it with a soft cloth to avoid scratching the unit. Do not use wet cloth, wax, or thinner.
  • Do not put your hands or foreign objects into the air inlet or outlet. Otherwise, product failure or physical injury may occur.
  • A description of the dangers of fire, electric shock or personal injury that may arise during cleaning and user maintenance (e.g. lubrication).
  • When using PuriSystems HEPA Pro UVIG indoors, please turn off combustion equipment such as fireplaces, furnaces, water heaters, and HVAC systems to avoid the risk of reverse emissions of carbon monoxide gas.
  • When repairing with PuriSystems HEPA Pro UVIG, be sure to lock the casters to avoid collision accidents.
  • Remind the user to disconnect the power supply before maintenance.

※ Keep this manual in a visible place near the machine for easy access.

INTRODUCTION

The PuriSystems HEPA Pro UVIG is a convenient filtration system that cleans the air. The PuriSystems HEPA Pro UVIG uses an effective blend of airflow and advanced filtration to expel airborne particles like mold spores, dust, pollen, and pet dander.The PuriSystems HEPA Pro UVIG is ideal for for restoration jobs,including water, sewage, and fire.

APPLICATION

Odor Control
When used with the optional activated carbon filter (P/N:), PuriSystems HEPA Pro UVIG is also excellent in odor control. Simply put the carbon filter in the pre-filter tank, it can capture a variety of odor-causing gas molecules, such as volatile organic compounds (VOC’s), smoke, soot, and paint odors.
Other Use
The cleaner is also useful in many other applications, including mold repair, fire damage, dust control, and sewage repair.

IDENTIFICATION
Congratulations on purchasing a PuriSystems HEPA Pro UVlG air scrubber. To take advantage of the warranty plan, be sure to note the serial number and date of purchase.
Serial Number: —————-
Date of Purchase: ————-

HOW IT WORKS

When set to maximum airflow, the scrubber draws air through two types of filters—a pre-filter and a HEPA/Activated Carbon Filter.

  1. Pre-Filter
    The first phase of filtration, the pre-filter, Captures initial dust and allergen particles.

  2. HEPA/Activated Carbon Filter
    The second phase of filtration, the HEPA/Activated Carbon Filter, catches smaller particles, down to 0.3 microns. Contributing to the control and prevention of the growth of bacteria, germs, and mold. And it captures 99.99% of dust and allergens.

  3. UV-C Light
    UV-C light technology works with filters to enhance the elimination of airborne germs. Titanium Dioxide is activated by the UV-C light to decompose the remaining odor molecules caused by smoking, cooking, and pets.

KEY FEATURES

PuriSystems HEPA Pro UVIG Air Scrubber - Overview

Specification

Category PuriSystems HEPA Pro UVIG
Power(V) 115Vac 60Hz
Power(W) High: 0.85 kW

Low: 0.75kw
Airflow| High: 2000CFM
Low: 800CFM
Size| 35. 6×27.6×30.3 inch
Weight| 152 lbs

INSTRUCTIONS

THE CONTROL PANEL
Power indicator
When the switch is On, the indicator light is on; when the switch is OFF, the indicator is off.
Circuit Breaker Switch
Circuit Breaker Switch is designed to prevent more than 12 amperes of current from passing through the circuit. If this happens, the switch will cut off power to the machine.
Pressure Gauge
The differential pressure is usually at 300Pa, which increases over time. When it reaches 500Pa, replace the filter in time.
Gear Switch
Rotate the knob clockwise to adjust the gears. The initial position is off. Gears 1, 2, and 3 correspond to low, medium, and high speeds, respectively.
UV-C Light Switch
For turn on/off UV Light.
Pressure Sensing Port
Used for differential pressure gauge to detect the pressure value, pay attention to check whether the port is blocked before use.

PuriSystems HEPA Pro UVIG Air Scrubber - Figure 1

FILTER
Filter grade and size chart

  1. Size:27.0×26.0×0.8(inch)
  2. An aluminum frame is put around the outer edge. It can collect dust of 10~20μm up to 90% in accordance with the standard of weight method.

PuriSystems HEPA Pro UVIG Air Scrubber - Figure 3

  1. Size: 24.0×24.0×11.5 (inch)

  2. It an collect dust of 0.3μm up to 99.97% in accordance with the standard of weight method.

  3. Size:24.0×24.0×11.5(inch)

  4. Activated carbon filter has efficient adsorption performance and can be used for air purification. The activated carbon filter material contains 100% surface adsorption capacity to remove volatile organic compounds (such as formaldehyde, toluene, hydrogen sulfide, chlorobenzene) and pollutants in the air.

  5. Size:24.0×24.0×11.5(inch)

  6. H14 Filter,The effective rate of 0.1 micron and 0.3 micron reaches 99.998%, which is the most effective filter for pollutants such as smoke, dust and bacteria.

Note: The activated carbon filter and H14 filter are sell separately.
Filter Replacement time

  1. when the pressure gauge reaches 500 pa.
  2. when the filter is damaged due to long-term use.
  3. when the filter blockage causes the suction capacity to decrease.

Parts Replacement

  1. Change the Filter
    First, turn off the unit, unplug the plug, pull up the Pre-filter, twist the internal fixed knob and remove the fixed rod, take out the HEPA filter, replace with a new HEPA filter, install the fixed rod after the replacement, and tighten the knob, Insert a new Pre-filter, and the replacement is complete.

  2. Change the UV-C Light
    First, turn off the unit, unplug the plug, pull up the Pre-filter, twist the internal fixed knob and remove the fixed rod, take out the HEPA filter, pull out the UV lamp to the left to separate it from the lamp holder, and remove the UV-C light. Replace with a new UV-C light, put in the HEPA filter, install the fixed rod and tighten the knob, insert the Pre-filter, and replace it.

WARNING

  1. Do not operate without a HEPA filter! Failing to use a HEPA filter or using an unauthorized power cord may cause damage to the electrical system or mechanical parts.
  2. When replacing the filter, please always wear approved protective equipment.
  3. If the value of the differential pressure meter is at 500pa, the high-efficiency filter must be replaced.

Wiring Diagram

PuriSystems HEPA Pro UVIG Air Scrubber - Figure 6

WARRANTY

All warranty benefits apply to the original owner only Warranty cannot be transferred or assigned.
1 YEAR (FROM DATE OF PURCHASE): PuriSystems warrants the unit’sparts will operate free of defects in material or workmanship. This includes factory laborers. At its discretion, will replace defective parts, including factory labor. This does not include transportation costs.
Customer Responsibilities: In order to take advantage of the warranty service, the customer must do the following:

  1. Customer must provide normal care and maintenance (including, but not limited to cleaning filters)
  2. Removal and re-installation of unit is the sole responsibility of owner.
  3. If customer cannot return unit to certified repair center, all costs associated with shipment are borne by the customer.In addition, all ancillary charges related to freight shipments, including but not limited to palletizing, wrapping, labeling,and pickup are associated with customer.
  4. If shipped, customer is responsible for all risk of loss or damage.

Purisystems Warranty Steps:

  1. Once goods are received , customers must log in www.purisystems.com to fill out the warranty registration form and submit to Purisystems company. We will receive your purchasing and installation information and save it. If no warranty registration is sent to us, warranty period will begin the day the shipment left the warehouse. Please be sure to record serial # and date of installation. You will need this information to receive the RA number.
  2. If warranty service is necessary, customers must contact Purisystems Tech Support by sales@purisystems.com or local technical service phone to receive a Return Authorization (RA number). Once an RA has been issued, customers should bring the unit to a certified repair center. Purisystems will arrange the shipping to bring the unit back to the Purisystems warehouse (at the expense of the customers) if customers are not available.
  3. After the unit has been received by Purisystems (whether at a repair center or the warehouse), Purisystems will have an initial inspection. If it is determined to be invalid warranty claim (see exclusions below), customers have to pay for all associated repair costs and shipping costs for units repair.
  4. Customers can pick up the unit after repair at their own expense for shipping. Units will have a rigorous testing before sending it back to customers.
  5. If the unit can no longer be fixed , and it is in the warranty period and determined to be valid claim, we will ship the customer a new unit within the same year warranty from the date of replacement.
  6. After parts are repaired or replaced by Purisystems, the original warranty period continues to apply until it meets its deadline. No extensions to the original warranty period .

Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:

  • Damage occurs in uses for which this product was not intended for.
  • Damage caused by unauthorized modification or alteration of the product.
  • Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
  • Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
  • Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
  • Damage caused by failure to perform proper maintenance of the product.

The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.

E-mail: sales@purisystem.com
Add:8605 SANTA MONICA BLVD

79525 WEST HOLLYWOOD, California, 90069 USA

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PuriSystems User Manuals