aspira Smart Air Ecocomfort 2.0 Instruction Manual
- June 13, 2024
- aspira
Table of Contents
- Putting into service
- Dimensions
- Contents of package
- Installation of several devices
- Type of installation
- Putting into service
- Technical data
- Accessories and spare parts
- General warnings
- Waste disposal
- Energy label
- Product fiche
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ASPIRVELO
AIR
Serie ECOCOMFORT 2.0 SMART
ENEN PRECISE FAN UNIT WITH HEAT RECOVERY.
EQUIPPED WITH ARTIFICIAL INTELLIGENCE AND SMART FUNCTIONS.
INSTALLATION MANUAL
Putting into service
- This manual contains the information required for installing and putting into service the fan system.
The information the user requires to use the system is provided in the Use and Installation Manual,that can be downloaded at the following link: pdf.fantinicosmi.it , framing the quad core you will be directed directly to the link.
pdf.fantinicosmi.it
Dimensions
Contents of package
- Folding outdoor grille
- Telescopic tube
- Filter
- Cartridge
- Electronic unit
- Electronic unit lid
- Lid
Wall bore
Installation of several devices
Electronic unit fixing holes
- Drilling template supplied.
- To mount the grille, follow the supplied instructions.
Type of installation
- Adjust according to the thickness of the perimeter wall.
- To mount the grille, follow the supplied instructions.
- The unit complies with the double insulation rules (Class II). It does not require an earth cable.
- Do not supply power to ECOCOMFORT 2.0 without first having mounted the electronic unit lid.
- Connect the 230V cable in the lower left terminal, passing it through the appropriate tear-proof device
WARNING
In case of a longer power supply failure at 230V, it could be necessary to
update the date and the hour from the Intelliclima+App, as shown in the
chapter “4.3.3.6 Day and Time” to restore the Reporting Function.
Putting into service
After having installed and powered the device, it must be associated to the Fantini Cosmi Intelliclima + app to be able to control it.
https://play.google.com/store/apps/details?id=com.fantinicosmispa.intelliclimasmart&gl
https://apps.apple.com/it/app/intelliclima/id124
- Download the app from one of the stores.
- Touch to start installation.
- Touch to open the app.
- Enter the registration data.
- Enter the username and password.
- Touch to use in Wi-Fi.
- Touch to use in Bluetooth low energy.
- Touch to confirm (only BLE).
- Touch to continue (only BLE).
- Touch to create a new home.
- Enter the name you want to give the hom and touch to confirm.
- Touch to add a device.
- Touch to add a VMC.
- Select Ecocomfort 2.0 Smart.
- Touch to accept the Privacy policy.
- Touch to allow access to the position of your device.
- Touch to continue.
- Select the device to associate.
- Touch to start the configuration (only first association).
- Press the blue button on the device (only first association).
- Touch to maintain the existing profile.
- Touch to overwrite the existing profile.
- Set date and time.
- Touch to continue.
- Select Master or Satellite Unit.
- Choose the rotation.
- Select the house (Master only).
- Set the sensor thresholds.
- Touch to continue.
- Select your Wi-Fi network.[2,4 GHz (802.11 b/g/n)]
- Enter the password of your Wi-Fi network and touch to continue.
- Check that the password is correct and touch to confirm.
- Enter the name and image you want to give to the zone.
- Touch to continue.
- Touch to finish.
You can now control the device via app.
Technical data
Fan speed m3/h| Maximum power W| Supply voltage| D2mnTw )|
dB(A) 1,5 mt| *dB(A) 3 mt| temperature
---|---|---|---|---|---|---
V low 20,5| 2,5| 230 V- 50 Hz| 40 dB| 18,5| 12,5| (- 20) — (+ 50) °C;
V medium 35| 4| 26,5| 20,5
V high 48,5| 6,3| 32,5| 26,5
V sleep 8| 2| ND| ND
(*) Noise reduction coming from outside with kit cod. AP19881.
Accessories and spare parts
ISO Coarse class filters according to UNI EN ISO 16890: 2017 (AP1984);
Panel for acoustic, thermal and anti-condensation insulation (AP1985);
Windproof and rainproof grille (code AP1612);
External noise reduction kit (code AP19881).
General warnings
Carefully read the installation instructions, the safety warnings, and the use and maintenance instructions in this manual, which must be stored with care for any future consultation.
-
The unit should only be installed by qualified technicians, in compliance with current standards and interposing an all-pole switch with contact opening distance equal to or greater than 3 mm.
-
The unit is intended to ventilate residential premises with heat recovery; different uses are not permitted and shall exempt the manufacturer from any responsibilities for the consequences resulting from improper use, as well as incorrect installation.
-
After removing the packaging, ensure the product is intact; if in doubt do not use it.
-
The use of any electrical appliance implies the observance of some fundamental rules. In particular:
-
Do NOT touch the appliance with wet hands, or wet or bare feet.
-
Do NOT expose the unit to atmospheric agents (rain, sun, etc.).
-
Before performing any maintenance or cleaning, disconnect the unit from the mains power supply, opening the all-pole switch installed on the line.
-
Do NOT power the appliance with the lid open.
-
The unit complies with 2014/30/EU and 2014/35/EU European Directives.
-
Do not obstruct the intake grille.
-
In compliance with current accident prevention legislation, ensure that the unit moving parts cannot be accessed after installation.
If an appliance operating on gas (or other fuels) is installed in the room to be ventilated, make sure there is an adequate exchange of air to ensure the perfect combustion thereof and proper operation of the fan unit. -
Do not install an extractor fan in the same duct where the fumes of a gas appliance are conveyed.
-
The unit can be installed only on a wall.
Waste disposal
The crossed-out wheelie bin symbol on the equipment indicates that at the end of its work life, the product must be disposed of separately from other waste. As such, the user must bring the equipment at the end of its life to appropriate electronic and electrotechnical waste collection centres or bring it back to the dealer when purchasing new equipment that is equivalent on a one-to-one ratio. Appropriate separate collection of the equipment for it to be subsequently recycled, treated and disposed of in an environmentally compatible way contributes to preventing possible negative effects on the environment and on health, and favours recycling the materials that make up the equipment. Illegally disposing of the product will subject the user to administrative sanctions pursuant to Leg.Dec. 22/1997” (article 50 and subsequent of Leg.Dec.no. 22/1997).
Energy label
EU/1254/2014, Annex, IV
Energy label
Product fiche
| | | AP19992 ECOCOMFORT 2.0 SMART
---|---|---|---
Classe di consumo energetico Specific energy consumption class| | | As
Consumo specifico di energia – China caldo Specific energy consumption –
Warmer climate| SEC| kWh/(m2a)| -18
Consumo specifico di energia – Clima temperato Specific energy consumption –
Avarege climate| SEC| kWh/(m2a)| -42,1
Consumo specifico di energia – Clima freddo Specific energy consumption –
Colder climate| SEC| kWh/(m2a)| -79,3
Tipologia di unita di ventilazione Typology of ventilation unit| | | bi-
direzionale
Tipologia di azionamento motore Type of drive| | | velocity multiple
Tipologia recuperatore di calore Type of heat recovery system| | |
rigenerativo
Efficienza termica del recuperatore Thermal efficency of heat recovery| Ili|
%| 81
Portata massima Maximum flow rate| Q”°’| mini| 48
Potenza elettrica assorbita Electric power input| P max| W| 6,58
Civello di potenza sonora Sound power level| LWA| d8(A)| 38
Portata di riferimento Reference flow rate| flier| [Ms| 0.0096
SPI
SPI| | W/(m’/h)| 0,12
Fattore di contra., Control factor| CTRL| | 0,65
Tipologia di control lo Control typology MIX| | | 1,21
Segnale visivo filtro
Position visual filter warning| | | assente
Istruzione per Finstallazione Instruction to install| | | pdflantinicosmi.it
Consumo annuo di elettricita Annual electricity consumption| AEC 0,84| kWh/a|
Risparmio di riscaldamento annuo – Clima caldo Annual heating saved -Warmer
climate| AHS| kWh/a| 20,2
Risparmio di riscaldamento annuo – Clima temperato Annual heating saved –
Average climate| AHS| kWh/a| 44,6
Risparmio di riscaldamento an nuo – Clima freddo Annual heating saved – Colder
climate| AHS| kWh/a| 87,2
FANTINI COSMI SPA
www.fantinicosmi.it
Via dell’Osio, 6 – 20049 Caleppio di Settala MI, Italy
Ph. +39 02 956821
Fax +39 02 95307006
info@fantinicosmi.it
SUPPORTO TECNICO
Tel. +39 02 95682278
supportotecnico@aspira.it
EXPORT DEPARTMENT
Ph +39 02 95682229
export@fantinicosmi.it
5679995C – 10/2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>