PuriSystems PuriCare S2 UVIG Air Scrubber User Guide

June 13, 2024
PuriSystems

PuriSystems PuriCare S2 UVIG Air Scrubber

WARNING : PuriSystems PuriCare S2, S2 UV, and S2 UVIG should only be used with parts approved by PuriSystems. The use of unauthorized parts or any alteration to the machine will void the warranty. Contact the customer support for any assistance.

SAFETY NOTES

Fire Safety

  • The unit with 3-prong power cord must be plugged in to a GFCI outlet.
  • The unit is not stackable. Do not place heavy objects on the unit and the power cord.
  • Check the power cord for wear, cuts, etc. before use. Do not use the machine with visible damage on the power cord.
  • Check filter for any damages before use.
  • Do not operate/touch the unit with wet hands.
  • Turn the unit’s power switch off before plugging the unit into a GFCI outlet.
  • Do not use the machine if it’s wet. Immediately unplug the unit if it gets in contact with water.
  • Unplug the unit during thunder or thunderstorms
  • Do not use or place this unit in a humid environment. This may cause of the electrical components to be wet.
  • Do not use this unit near flammable equipment.
  • Do not use this unit in a room/space with flammable gas.
  • Do not restrict airflow by placing it near any obstructions or wall.
  • When cleaning, unplug the unit first. Do not use wet cloth, wax or thinner.
  • Do not put your hand or foreign object into the air inlet or outlet to avoid physical injury and product damage.
  • When in use, turn off combustion equipment such as fireplaces, furncases, water heaters, ovens, stoves, burners, and many more.
  • Always lock the casters especially when performing maintenance or repair to avoid collisions.
  • Unplug the unit before performing maintenance or repair.
  • Keep this manual in a visible place near the machine for easy access.

INTRODUCTION

The PuriSystems PuriCare 82 is a convenient filtration system that cleans the air. The Puri Systems Puri Care 82 uses an effective blend of air flow and advanced filtration to expel airborne particles like mold spores, dust, pollen, and pet dander.The PuriSystems PuriCare 82 is ideal for for restoration jobs,including water, sewage, and fire.

APPLICATION

Odor Control
PuriSystems PuriCare 82, 82 UV, 82 UVIG is also excellent in odor control. Simply insert the activated carbon filter in the pre-filter slot. This filter can capture variety of odor-causing gas molecules such as volatile organic com pounds (VOC’s), smoke, soot and paint odors.

Other Use
The cleaner is also useful for many other application. That includes mold repair.fire damage restoration, dust control, and sewage repair.

IDENTIFICATION
Congratulations on your purchase. To help you with future warranty claims, be sure to write your serial number and date of purchase on the text lines below.

HOW IT WORKS

When set to maximum airflow, the scrubber draws air through two types of filters-a pre-filter and a HEPA/ Activated Carbon Filter.

  1. Pre-filter
    The first phase of filtration, the Pre-filter, Captures initial dust and allergen particles.

  2. Pure HEPA Filter H13
    The second phase of filtration, the Pure HEPA Filter, catches smaller particles, down to 0.3 microns. Contributes to the control and prevention of the growth of bacteria, germs, and mold. Captures 99.99% of dust and allergens.

  3. UV-C Light
    UV-C light technology works with filters to enhance the elimination of airborne germs Titanium Dioxide is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking, and pets (Only for PuriCare S2 UV & S2 UVIG).

  4. Ion Generator
    The ion generator can be selected to work or not through the ion generator switch. Negative ions can lower blood pressure, improve sleep and lung function, invigorate people,and improve body imagination and immunity (Only for PuriCare S2 UVIG).

KEY FEATURES

INSTRUCTIONS

THE CONTROL PANEL

Circuit Breaker Switch
The circuit breaker switch is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. Its basic function is to interrupt current flow after a fault{10 Amps or more is being drawn) is detected.

Pressure Gauge
Display the filter pressure difference, and replace the filter. Please refer to the “Horizontal air scrubber different filter replacement standards” table on Page 7 for details.

Gear Switch
The machine doesn’t works when the gear switch in “OFF”. Rotate the knob to adjust the fan speed. With Activated Carbon Filter best fan speed.

UV-C Light Switch
To turn ON/OFF the UV light. Ion Generator Switch To turn ON/OFF the ion generator.

Pressure Sensing Port
Used for differential pressure gauge to detect the pressure value, pay attention to check whether the port is blocked before use.

FILTER

Filter grade and size chart

WARNING

  1. Do not operate without a HEPA filter! Failing to use a HEPA filter or using an unauthorized power cord may cause damage to the electrical system or mechanical parts.
  2. When replacing the filler, please always wear approved protective equipment
  3. Please strictly follow the “Negative Air scrubber different filter replacement standards” table to replace the filler.

Parts replacement

  1. Change the filter
    First turn o fflhe unit, unplug the plug, pull up the Pre-filter, twist the internal fixed knob and remove the fixed rod, take out the HEPA filter, replace with a new HEPA filter, install the fixed rod after the replacement and tighten the knob , Insert a new Pre- filter, and the replacement is complete.

  2. Change the UV-C Light
    First turn o fflhe unit, unplug the plug, pull up the Pre-filter, twist the internal fixed knob and remove the fixed rod, take out the HEPA filter, pull out the UV lamp to the left to separate it from the lamp holder, and remove the UV-C light. Replace with a new UV-C light, put in the HEPA filter, install the fixed rod and tighten the knob, insert the Pre-filter, and replace it.

SPECIFICATION

Category PuriSystems PuriCare S2 Series
Power(V) 115V AC 60Hz
Power(W) High: 600 kW          Low: 200 kW
Airfow High: 2,000 CFM        Low: 800 CFM
Size 39.76×29.33×32.68 inch
Weight 132.28 lbs

WARNING

  1. Do not operate without a HEPA filter! Not using a HEPA filter or using an unauthorized power cord may cause damage to the electrical system or mechanical parts.
  2. When replacing the filter, please always wear approved protective equipment.
  3. Please strictly follow the “Horizontal air scrubber different filter replacement standards” table to replace the filter.

WIRING DIAGRAM

WARRANTY

All warranty benefits apply to the original owner only Warranty cannot be transferred or assigned.

1 YEAR (FROM DATE OF PURCHASE):

PuriSystems warrants the unit’s parts will operate free of defects in material or workmanship. This includes factory laborers. At its discretion, PuriSystems will replace defective parts, including factory labor. This does not include transportation costs.
Customer Responsibities : In order to take advantage of the warranty service, the customer must do the following:

  1. Customer must provide normal care and maintenance (including, but not limited to cleaning filters)
  2. Removal and re-installation of unit is the sole responsibility of owner.
  3. If customer cannot return unit to certified repair center, all costs associated with shipment are borne by the customer.In addition, all ancillary charges related to freight shipments, including but not limited to palletizing, wrapping, labeling,and pickup are associated with customer.
  4. If shipped, customer is responsible for all risk of loss or damage.

PuriSystems Warranty Steps:

  1. Once goods are received customers must log in www.purisystems.com to fill out the warranty registration form and submit to Purisystems company. We will receive your purchasing and installation information and save it. If no warranty registration is sent to us, warranty period will begin the day the shipment left the warehouse. Please be sure to record serial # and date of installation. You will need this information to receive the RA number.
  2. If warranty service is necessary, customers must contact Purisystems Tech Support by sales@purisystems.com or local technical service phone to receive a Return Authorization (RA number). Once an RA has been issued, customers should bring the unit to a certified repair center. Purisystems will arrange the shipping to bring the unit back to the Purisystems warehouse (at the expense of the customers) if customers are not available.
  3. After the unit has been received by Purisystems (whether at a repair center or the warehouse), Purisystems will have an initial inspection. If it is determined to be invalid warranty claim (see exclusions below), customers have to pay for all associated repair costs and shipping costs for units repair.
  4. Customers can pick up the unit after repair at their own expense for shipping. Units will have a rigorous testing before sending it back to customers.
  5. If the unit can no longer be fixed , and it is in the warranty period and determined to be valid claim, we will ship the customer a new unit within the same year warranty from the date of replacement.
  6. After parts are repaired or replaced by Purisystems, the original warranty period continues to apply until it meets its deadline. No extensions to the original warranty period.

IMPORTANT NOTICE: Keep the item’s packaging in case warranty service is required.

Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:

  • Damage occurs in uses for which this product was not intended for.
  • Damage caused by unauthorized modification or alteration of the product.
  • Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
  • Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
  • Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
  • Damage caused by failure to perform proper maintenance of the product.

The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

PuriSystems User Manuals

Related Manuals