Thank you for purchasing a Sealey product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND
WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE
INSTRUCTIONS SAFE FOR FUTURE USE.
SAFETY
1.1. ELECTRICAL SAFETY
❑ WARNING! It is the responsibility of the owner and the operator to read,
understand and comply with the following: You must check all electrical
products, before use, to ensure that they are safe. You must inspect power
cables, plugs, sockets, and any other connectors for wear or damage.
You must ensure that the risk of electric shock is minimized by the
installation of appropriate safety devices. A Residual Current Circuit Breaker
(RCCB) should be incorporated into the main distribution board. You must also
read and understand the following instructions concerning electrical safety.
✓ Ensure that cables are always protected against short circuits and overload.
✓ Regularly inspect power supply cables and plugs for wear or damage and check
all connections to ensure that none are loose.
✓ Ensure that the voltage marked on the appliance matches the power supply to
be used and that the plug is fitted with the correct fuse – see fuse rating at
right.
x DO NOT use worn or damaged cables, plugs, or connectors. Have any
faulty items been repaired or replaced immediately by a competent electrician?
✓ It is recommended that this device is wired directly to a fused isolator
switch. If, however, a plug is fitted, the following applies:
✓ Fit a new plug according to the following instructions (the UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been
correctly connected, and that the cable restraint is tight.
1.2. GENERAL SAFETY
✓ Check that the dehumidifier is in sound condition and in good working order.
Take immediate action to repair or replace damaged parts.
✓ Use recommended parts only. Unauthorized parts may be dangerous and will
invalidate the warranty.
x DO NOT stand or place any object less than 10cm from the front or rear of
the unit.
x DO NOT obstruct the air intakes or outlets of the dehumidifier.
x DO NOT place any object into the outlets – the unit has a fan running at
high speed, contact with this will cause injury.
x DO NOT operate the dehumidifier when you are tired or under the influence of
alcohol, drugs or intoxicating medication.
x DO NOT switch the dehumidifier off by disconnecting it from the mains.
ALWAYS switch to the -OFF” position first.
x DO NOT remove the float lever from the water collection tank.
x DO NOT connect or disconnect the plug from the mains with wet hands.
✓ Always discard the water from the collection tank, DO NOT use it for any
other purpose.
✓ Place the dehumidifier on a level and stable surface.
x DO NOT use the dehumidifier at ambient temperatures below 5°C.
x DO NOT use the dehumidifier outside. x DO NOT use means to accelerate the
defrosting process or to clean, other than those recommended by the
manufacturer.
✓ The appliance shall be stored in a room without continuously operating
ignition sources (for example open flames, an operating gas appliance, or an
operating electric heater. • DO NOT pierce or burn.
✓ Be aware that refrigerants may not contain an odor.
✓ When using continuous draining, make sure that the drain hose is positioned
correctly.
✓ Ensure that heating appliances are not exposed to the flow of air from the
dehumidifier.
✓ Before attempting to move the dehumidifier, empty the contents of the
collection tank.
✓ Switch off and disconnect it from the mains before attempting any cleaning
or other maintenance work.
✓ Ensure that the dehumidifier is correctly turned off when not in use, and
stored in a safe, dry area, out of reach of children. This appliance can be
used by children aged 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience or knowledge if they have
been given supervision or instruction concerning the use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
❑ WARNING : If the power cord is damaged, it must be replaced by a
professionally trained person.
NOTE: This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
INTRODUCTION
A totally dry heat, no condensation, no gas, no fumes, and no smell. A single infrared bulb allows the heater’s maximum temperature to be reached quickly with a Helen coating to reduce glare. Highly polished aluminum reflector for maximum heat efficiency. Controlled by push-on/off switch or via remote control (batteries not included). Ideal for industrial or domestic applications. Outdoor use only (IP55). Mounting brackets and fixings included.
SPECIFICATION
Model no: ……………………………………………AK466D
Tank capacity: ……………………………………. 12L
Supply: ……………………………………………….230V
Motor power: ………………………………………..500W
OPERATION
-
Unpack the product and check contents, should there be any damaged or missing parts contact your supplier immediately. Store the sump extraction probes in storage pipe on the back of the trolley
-
Ensure you have read, understood and apply the safety instructions.
-
To achieve oil extraction the sump oil temperature must be 50 ºC or above.
-
Check that the waste oil canister cap is correctly screwed on, and the hose tap is turned off.
-
Choose the appropriate extraction probe (diameter, flexible or rigid) for the type of vehicle, and push it onto the hose end.
NOTE: To provide a faster extraction, the wider diameter probe is preferred where access allows. -
Check length of the dip stick against the length of the probe (fig 1) to establish an approximate depth, and mark the probe at this point.
-
Insert the probe through the dip stick entry hole (fig 2) and gently push the probe down to the bottom of the sump.
-
Switch the pump on and open the hose tap. The pressure gauge (fig 3) should register 40cm hg or above as extraction commences.
-
When sump is empty the pressure gauge will indicate zero. Move probe around the bottom of the sump to extract any remaining oil.
-
Switch the pump off, turn off the hose tap and remove the extraction probe from the sump.
-
When extraction is complete unplug from the mains power supply.
-
Dispose of waste oil in accordance with local authority regulations.
FAULT FINDING
-
Should the pressure gauge not reach the required 40cm hg check the following:
a) Ensure the probe has been pushed deep enough to access the oil.
b) Air leak. Ensure all joints and seals on the pump unit and hose are tight.
c) The oil is below the 50°C temperature
c) The extraction may be complete. -
Motor not working:
a) Check electrical supply and connections.
b) Check there are no foreign objects blocking or passing through the motor’s front grill.
MAINTENANCE
‰ WARNING! Ensure the drainer is disconnected from the mains electrical supply before attempting any maintenance.
- Keep the unit clean, wipe off any oil spillage.
- Keep the probes clean and check that the tubes are clear.
- Check that all tubes, hoses, and connections are in good condition.
- Regularly check all electrical connections.
- To maintain the motor use an authorised service agent.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories, and packaging should be sorted, taken to a recycling center, and
disposed of in a manner that is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
BATTERY REMOVAL: REMOTE CONTROL
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd
are required to inform potential purchasers of products containing batteries
(as defined within these regulations), that they are registered with Valpak’s
registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration
Number (BPRN) is BPRN00705.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications, and component parts without
prior notice. Please note that other versions of this product are available.
If you require documentation for alternative versions, please email or call
our technical team at technical@sealey.co.uk
or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: The guarantee is 12 months from the purchase date, proof of
which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
01284 703534
sales@sealey.co.uk