EG4 ELECTRONICS EG4 Indoor Buildable Conduit Box User Guide
- August 16, 2024
- EG4 ELECTRONICS
Table of Contents
**EG4 ELECTRONICS EG4 Indoor Buildable Conduit Box User Guide
**
ABBREVIATIONS
- AWG – American Wire Gauge
- In-lbs. – Inch Pounds
- A – Amps
- kW – Kilowatt
- Ah – Amp hour(s)
- kWh – Kilowatt-hour
- AC – Alternating Current
- LCD – Liquid Crystal Display
- AFCI – Arc-Fault Circuit Interrupter
- LFP – Lithium Iron Phosphate
- AHJ – Authority Having Jurisdiction
- L1 – Line 1
- kAIC – kilo-Amp Interrupting Capability
- L2 – Line 2
- ANSI – American National Standards Institute
- mm – Millimeters
- BAT – Battery
- MPPT – Maximum Power Point Tracking
- BMS – Battery Management System
- mV – Millivolt
- COM – Communication
- N – Neutral
- CT – Current Transformer
- NEC – National Electric Code
- DC – Direct Current
- NEMA – National Electrical Manufacturers Association
- DIP – Dual In-line Package
- NFPA – National Fire Prevention Association
- DOD – Depth of Discharge
- Nm – Newton Meters
- EG – Equipment Ground
- NOCT – Normal Operating Cell Temperature
- EGS – Equipment Grounding System
- PC – Personal Computer
- EMC – Electromagnetic Compatibility
- PCB – Printed Circuit Board
- EPS – Emergency Power System
- PE – Protective Earth
- ESS – Energy Storage System
- PPE – Personal Protective Equipment
- E-Stop – Emergency Stop
- PV – Photovoltaic
- FCC – Federal Communication Commission
- RSD – Rapid Shut Down
- GE – Grounding Electrode
- SCC – Standards Council of Canada
- GEC – Grounding Electrode Conductor
- SOC – State of Charge
- GFCI – Ground Fault Circuit Interrupter
- STC – Standard Testing Conditions
- GFDI – Ground Fault Detector/Interrupter
- UL – Underwriters Laboratories
- Imp – Maximum Power Point Current
- UPS – Uninterrupted Power Supply
- IEEE – Institute of Electrical and Electronic Engineers
- V – Volts
- IP – Ingress Protection
- VOC – Open-Circuit Voltage
- Isc – Short-Circuit Current
- VMP – Voltage Maximum Power
BRIEF DESCRIPTION
The EG4® Indoor Buildable Conduit Box allows users a simple and effective way to protect cables and connections between battery and inverter. The conduit box is designed to pair the EG4 WallMount Indoor 280Ah Lithium Battery with either the EG4 18kPV Hybrid Inverter, EG4 12kPV Hybrid Inverter, or EG4 6000XP Off-Grid Inverter.
PACKING LIST
The items listed below will arrive with the product shipment:
-
Disassembled Indoor Buildable Conduit Box (6 pcs)
Total Weight: 14.70 lbs. (6.66 kg)
-
M6 x 1.0 Phillips Flat Head Screw (x10)
-
M6 x 1.0 Phillips Hex Head Screw w/ Washer set (x4)
-
M6 x 1.0 Phillips Hex Head Screw w/ Washer set (x4) (for battery mounting)
-
Rotating Cover
GLW-M63 Qty 4
GLW-M50 Qty 1
GLW-G 1 Qty 2
GLW-PG21 Qty 2 -
Grommets
RSB-28 Qty 2
RSB-35 Qty 2
RSB-50 Qty 1
RSB-63 Qty 4
TOOLS NEEDED
- Phillips head screwdriver
- 10 mm socket and ratchet
- Proper PPE (Personal Protective Equipment)
CONDUIT BOX KNOCKOUT/HOLE PATTERNS & SCHEMATICS
EXTERIOR DIMENSIONS
Top View
RIGHT & LEFT SIDE PANEL KNOCKOUT DIMENSIONS
Front View
Right Panel
Left Panel
TOP PANEL KNOCKOUT DIMENSIONS
Top Panel
CONDUIT BOX ASSEMBLY
The Indoor Buildable Conduit Box is a highly recommended accessory to enclose all battery cables for added protection and safety. The conduit box holds the wiring that runs between the inverter and the battery
No. | Item |
---|---|
1 | Bottom Plate |
2 | Left Side Plate |
3 | Right Side Plate |
4 | Back Plate |
5 | Front Plate |
6 | Top Plate |
7 | Ground Screw and Wire |
NOTE: Bottom plate should have the GROUND screw and wire (labeled 7 in the image) to the back left when viewing the front for assembly
- Starting with the bottom plate (labeled 1 in the image), ensure the ground screw and wire are securely fastened. Align the left-side plate (labeled 2) with the holes on the bottom plate. Attach the left-side plate using three of the included M6 x 1.0 Phillips flat head screws.
- Locate the right-side plate (labeled 3), align with the holes in the bottom plate. Attach to the bottom plate using three of the included M6 x 1.0 Phillips flat head screws.
- Locate the back plate (labeled 4), align and attach using four of the M6 x 1.0 Hex head screw with washer set. Install the M6 x 1.0 Hex head screw with washer set going from the inside of the box to the outside.
- Locate the front plate (labeled 5), align and attach using the pre-installed thumbscrews.
- Locate the top plate (labeled 6), align with holes on top of the left and right-side plates. Attach the top plate using four of the included M6 x 1.0 Phillips flat head screws.
- Use the remaining four M6 x 1.0 Hex head screw with washer set to mount the conduit box to the battery
NOTES
CONTACT US
support@eg4electronics.com
903-609-1988
www.eg4electronics.com
©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
VERSION 1.0 | INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE.
MODEL #: CS-280-BD-IN-XY