The EG4 Chargeverter 5KW AC Charger 100A 48VDC is a high-powered charger designed to charge LiFePO4 batteries. It comes with safety features such as a grounding system and overcurrent protection to ensure the safety of the user and the product while in use. The product has an LCD display and function buttons that allow for easy operation and monitoring during charging.

Product Usage

  1. Before using the EG4 Chargeverter 5KW AC Charger, read the user manual carefully.
  2. Inspect the unit before installation to ensure that nothing is damaged.
  3. Connect the AC line input to a suitable power source using the prewired 250V, 30A, twist-lock plug provided.
  4. Connect the positive and negative battery cable inputs to the corresponding terminals on the battery being charged.
  5. Turn on the unit and use the function buttons to set the charging parameters according to the battery manufacturer’s specifications.
  6. The power indicator and charging indicator will show the status of the unit during operation.
  7. If at any point during use, there is an issue with the product, refer to the troubleshooting section of the user manual or contact the tech department of the distributor where you purchased your product for assistance.
  8. When maintenance or cleaning is required, disconnect all wiring before attempting any work on the unit. Do not disassemble the unit, take it to a qualified service center for repair.
  9. Follow all safety instructions provided in the user manual during use to avoid electric shock, fire, or bodily harm.

ABOUT THIS MANUAL

Purpose
This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read this manual carefully before installation and operation.

Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.

SAFETY INSTRUCTIONS

WARNING: This section contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
  2. CAUTION – This charger is set up to charge LiFePO4 batteries. Other battery chemistries are supported. However, verify with the battery manufacturer for charging specifications prior to use, otherwise battery damage and/or bodily harm can occur.
  3. Do not disassemble the unit. When service or repair is required, take it to a qualified service center. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wiring before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION – Use extreme care when attaching this device to a battery.
  6. NEVER charge a frozen battery.
  7. Be very cautious when working with metal tools on or around batteries. A potential riskexists for a dropped tool to spark or short circuit batteries or other electrical parts causing a fire.
  8. Please strictly follow the installation procedure when connecting or disconnecting DCterminals. Please refer to installation section of this manual for details.
  9. Breaker is required as overcurrent protection for the power supply.
  10. GROUNDING INSTRUCTIONS -This charger should be connected to a permanent ground wiring system. Be sure to comply with local requirements and regulations when using this charger.
  11. NEVER short DC inputs.
  12. Warning!! Only qualified personnel are able to service this device. Please contact thetech department of the distributor where you purchased your product for assistance withany issues.

DISCLAIMER

EG4 reserves the right to make changes to the material herein at any time without notice. You may refer to the EG4 website at www.eg4electronics.com for the most updated version of our manual.

PRODUCT OVERVIEW

EG4-ELECTRONICS-48VDC-5KW-AC-Charger-FIG-1

  1. Power indicator
  2. Charging indicator
  3. Function button – ESC
  4. Function button – UP
  5. Function button – DOWN
  6. Function button – ENTER
  7. LCD display
  8. Battery breaker
  9. Holding bracket
  10. AC line input
  11. Prewired 250V, 30A, twist-lock plug11a. Plug pinout
  12. Positive battery cable input
  13. Negative battery cable input

Other Common 30A 120V Plug Pinouts

EG4-ELECTRONICS-48VDC-5KW-AC-Charger-FIG-3

Warning!! Plug pinouts are provided as an example. Please seek guidance from a qualified professional before making any modifications.

INSTALLATION

Unpacking and Inspection

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of the package:

  1. The unit × 1
  2. User manual ×1
  3. Screws × 4

Mounting the Unit

Consider the following points before selecting where to install:

  1. Do not mount the charger on flammable construction materials.
  2. Suitable for mounting on concrete or other non-combustible surface only.
  3. Install this charger at eye level or a location that allows the LCD screen to be easily viewed.
  4. The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  5. The recommended installation position is to be attached to the wall.
  6. Verify there is sufficient room for heat dissipation and space for wires.

Chargeverter can produce heat of more than 131°F (55°C). It is recommended to mount this unit on appropriate backing, such as cement board, with sufficient clearance around the unit to allow proper airflow. Do not block the air vents

Install the unit by securing with four M4 screws.EG4-ELECTRONICS-48VDC-5KW-
AC-Charger-FIG-4

Warning: Ensure battery breakers and/or battery on/off switches are in the off position and the charger is not plugged in while installing battery charging cables.

AC and DC Connections

  • Connect battery cables to the battery terminals or bus bars using appropriate size bolts.
  • Ensure charger cable ring terminals are attached to the battery terminals/bus bar of theproper polarity and tightened to the proper torque specifications.
  • For 240V usage, plug the charger into a 250V 30A twist lock receptacle with a dedicated30A breaker.
  • For 120V usage, plug the charger into a 125V 30A receptacle with a dedicated 30Abreaker.
  • An additional adapter cable (sold separately) will be required.

OPERATION

Power ON/OFF

  1. Ensure that the battery cables are securely connected.
  2. Plug the charger into an outlet of the proper voltage and amperage.
  3. Turn on battery breakers and/or battery on/off switches.
  4. Turn on the built-in battery breaker on the front of the unit.
  5. The unit will begin charging and work normally if properly connected.

Operation and Display Panel

The operation and display panel, shown in the chart below, is located on the front panel of the AC charger. It includes two indicators, four function keys and an LCD display, indicating the operating status and input/output power information of the unit.

LED Indicator

EG4-ELECTRONICS-48VDC-5KW-AC-Charger-FIG-5

Function Keys

EG4-ELECTRONICS-48VDC-5KW-AC-Charger-FIG-6

LCD Setting

Press the “ENTER” button on the front of the unit to enter the settings mode. Press “UP” or “DOWN” button to select setting programs. Press “ENTER” button to confirm the selection or “ESC” button to exit.

Setting Programs

EG4-ELECTRONICS-48VDC-5KW-AC-Charger-FIG-7

  • Recommended 30A charging rate per battery to maintain battery lifespan and 85A total charging rate to reduce heat output of the unit.