Pro tech QM7320 Tester Alcohol Breath Fuel Cell LCD User Manual
- August 19, 2024
- PRO TECH
Table of Contents
Fuel Cell Breathalyser
with Advanced Flow Detection
User Manual
QM7320
GENERAL INFORMATION & SAFETY INSTRUCTIONS
- Use ALKALINE batteries only
- DO NOT DRINK AND DRIVE!
WARNING: The manufacturer is not responsible for any potential injury from misuse.
BOX CONTENTS
- 1x Breathalyser
- 1x AA Battery
- 1x Mouthpiece Set
OVERVIEW
BEFORE FIRST USE
Prior to using your product, please read all the safety and operating
instructions thoroughly. Please ensure you follow the steps below before using
the product. We recommend you keep the original packaging for storing the
product when not in use.
Please pay close attention to the section entitled Important Safety and
General Instructions. Find a safe and convenient place to keep this
instruction manual for future reference.
Unpack the product but keep all packaging materials until you have made sure
your new product is undamaged and in good working order.
GETTING STARTED
Battery
The tester requires One (1) AA Alkaline battery to operate. Press down with
little pressure and slide away the battery cover from back of the unit.
Install the battery and close the battery cover. (** It is recommended to use
NEW alkaline batteries)
15 Minute Observation Period
It is suggested to wait 15 minutes from smoking and drinking, and rinse your
mouth with water before using the unit. If you do not wait enough time and
perform a test just after drinking, the reading will fluctuate very high
reading and then drop gradually. It is due to the strong alcohol residue
inside your mouth that enhanced the measured values. In addition, if the
alcohol residue inside mouth (without enough wait time) is of too high
concentration, it might have potential to damage the sensor.
WARNING: Failure to wait 15 mins could give inaccurate test results and damage the sensor!
Optimal Accuracy at Room Temperature
It is recommended to conduct breath tests at room temperature for optimal
accuracy. It is also recommended to store the unit in room temperature
environment (when not using the unit for long time) to maintain the healthy
state of the sensor. Do not use or store the unit under extreme temperature
setting. (eg: store inside car under extreme summer or winter temperature)
TAKING A BREATH TEST
Insert a mouthpiece
Insert mouthpiece firmly into the slot. Additional mouthpieces could be
purchased from your distributor.
NOTE: Tests conducted without using mouthpiece might contribute
inaccurate results. It is recommended to use mouthpiece in every breath test.
Breath Testing Modes (Automatic/Manual)
The breathalyser is capable of conducting Automatic and Manual tests.
Automatic test – an easiest way to collect a deep lung sample.
The flow system monitors the subject’s breath and automatically takes sample
near the end of the breath flow.
Manual test – normally used only when the subject is unable to conduct an
automatic test.
Conducting a breath test
| Press Power button for 2 sec to power on the unit.The unit initiates sensor
warm-up process. Timer starts to count down.
---|---
Taking an Automatic Test
| When you see “rdy” (Ready) with a beep sound, take a deep breath and blow
into the mouthpiece moderately, and at a constant speed and pressure.
---|---
| It displays “[—” and alert a continuous beep, indicates a proper breath flow
is detected. At the end of breath flow (~5 sec), the tester would
automatically take the breath sample.
“click, click”| Blow until you hear the 2 ‘click’ sound (click, click) is
complete to signal sampling process is successful.
| Tester starts analyzing the collected breath sample and shows “[. —”
(Calculating). Wait for a short while and the BAC result would be displayed.
Taking an Manual Test
| When you see “rdy” (Ready) with a beep sound, apart from let the tester to
start collect breath sample automatically, you could also manually start the
breath sample collection process by pressing Left button (Manual test mode).
The manual test mode starts and it displays “L. —” and alert a continuous beep
sound.
---|---
| Take a deep breath and blow into the mouthpiece moderately, and at a
constant speed and pressure.
“click, click”| Blow until you hear the 2 ‘click’ sound (click, click) is
complete to signal sampling process is successful.
| Tester starts analyzing the collected breath sample and shows “[. —”
(Calculating). Wait for a short while and the BAC result would be displayed.
Read the results
BAC result would be displayed in either format of (‰, %, mg/l) according to
your country specific BAC display format. In case you would like to change the
display format, simply press LEFT button to change between display format.
At some occasion, the unit may auto long beep before you blow into the unit and display result as 0.00. This happens because there is a possibility to measure a very low presence of other substance on the sensor after long storage without usage. In this case, simply restart another test.
At some occasion, the unit may display result as ”Out”. This happens because the test has been conducted in either too cold or too hot temperature environment. Please bring the tester back to a normal room temperature environment. You might need to wait few minutes for the sensor insde the tester to stable down to room temperature condition before conduct a re-test.
*The BAC result will show on display for 30 seconds. The unit will turn off automatically afterwards. You can also turn off the unit at any time by pressing and holding down ‘POWER’ button for 3 seconds.
Suggested wait time between tests
After you have completed the first test and would like to take a second test
and so on, it is recommended to WAIT AT LEAST FEW MINUTES (PREFERABLY 5-10
MINS) between tests to prevent the sensor being saturated and to keep the
healthy state of the sensor.
TEST RECORD MEMORY MODE
Recall cumulative test count
During countdown, press ‘POWER’ button to display the cumulative test count –
the number of tests it has performed.
In case you would like to reset this counter, you could long press LEFT button
until you see the counter is reset to zero.
NOTE: It is recommended to recalibrate the unit once every year or after 300 tests, whichever comes first.
Recall previous test results (up to 16 records)
And then press ‘POWER’ button again to display the latest test record
(indicated by the serial number’l’ on screen, followed by the corresponding
result) Press LEFT button to display the next test records sequentially upto
the 16th test record history.
Press RIGHT button to see the records in backward order.
To exit the test record memory mode, press ‘POWER’ button again back to
countdown.
SYSTEM MESSAGE
Display | Cause and Course of Action |
---|---|
This message means the unit detected an out of range high alcohol |
concentration (above 4.00‰ BAC / 0.400%BAC / 2.00 mg/L).
| This message (Flow) means insufficient or uneven blowing is detected. Kindly
perform another test.
| This message means Sensor Not Ready. It happens when high concentration of
alcohol residue or pollutant is found on sensor from last test. Kindly switch
off unit and wait few minutes before conduct next test.
| This message (Repeat) means the unit could not complete a test.
Kindly repeat another test.
| This message means the test has been conducted in either too cold or too hot
temperature environment. Please bring the unit back to a normal room
temperature environment. Suggest to wait few minutes for the sensor inside the
unit to stable down to room temperature condition before conduct a re-test.
| This message means Low Battery. Replace new AA alkaline batteries.
PRECAUTIONS
- Allow at least 15-20 mins after drinking, smoking before testing. Rinse mouth with water before testing.
- For more accurate results, it is recommended to have the unit recalibrated for every 12 months or 300 tests.
- The unit is designed to be used in a temperature range of 10-40C (Celsius), with optimal accuracy for tests conducted at room temperature (i.e: around 20-26C Celsius).
- It is normal to see test result below 0.10‰ OR 0.010% BAC OR 0.050mg/L when you did not drink any alcohol before. This is because it is possible to measure other substance in your breath other than alcohol in some occasions.
- Do not use the unit as a tool to determine you should operate vehicle. The BAC result displayed is for reference only. Manufacturer and dealer disclaims any legal responsibility for the measured test value.
MAINTENANCE
To keep the unit in a healthy condition, it is suggested to use the unit at
least once a month.
The breathalyser is calibrated during manufacture using advanced alcohol
simulation equipment. Known alcohol concentrations are passed through the
sensor to set baseline values for testing. During testing, the unit compares
users’ breath samples to these baseline values.
The accuracy of breath alcohol testers can fluctuate after six to twelve
months of normal use, depending on the number of tests performed and operating
conditions.
If this product is providing inconsistent test results, is not providing any
test results, or provides unusually high or low test results, the product
should be recalibrated.
SPECIFICATIONS
BAC Detection Range| 0.00 to 4.00 ‰BAC (i.e: 0.000 to 0.400%BAC or 0.00 to
2.00 mg/l)
---|---
Accuracy| +/- 0.05 ‰BAC or +/- 0.005 %BAC at cal. point at room temp.
Warmup| Within 5 seconds (* at low concentration test)
Response time| Within 10-30 seconds
Sensor| Electrochemical Fuel Cell sensor
Operating temperature| 10 – 40°C (50 – 104ºF)
Display panel| Digital LCD display with backlight
Digital display| 3 digits (‰BAC) or 4 digits (%BAC)
Power| One 1.5V AA Alkaline Battery
Battery life| Approx. 500-1000 tests with new battery
Dimensions| 114 x 51 x 18 mm
Recalibration| Recommended every 6-12 months or 300 tests
WARRANTY
Our product is guaranteed to be free from quality and manufacturing defects
for a period of 12 Months.
If your product becomes defective during this period, Electus Distribution
will repair, replace, or refund where a product is faulty; or not fit for
intended purpose.
This warranty will not cover modified product; misuse or abuse of the product
contrary to user instructions or packaging label; change of mind and normal
wear and tear.
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and for compensation for any other reasonably foreseeable loss or damage. You
are also entitled to have the goods repaired or replaced if the goods fail to
be of acceptable quality and failure does not amount to a major failure.
To claim warranty, please contact the place of purchase. You will need to show
receipt or other proof of purchase. Additional information may be required to
process your claim. Should you not be able to provide proof of purchase with a
receipt or bank statement, identification showing name, address and signature
may be required to process your claim.
Any expenses relating to the return of your product to the store will normally
have to be paid by you.
The benefits to the customer given by this warranty are in addition to other
rights and remedies of the Australian Consumer Law in relation to the goods or
services to which this warranty relates.
This warranty is provided by:
Electus Distribution
46 Eastern Creek Drive,
Eastern Creek NSW 2766
Ph. 1300 738 555
Distributed by:
Electus Distribution Pty Ltd
46 Eastern Creek Dr,
Eastern Creek NSW 2766 Australia
Ph 1300 738 555
www.electusdistribution.com.au
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>