DATALOGIC BLADE 1D Reader Scanners User Guide
- August 13, 2024
- DATALOGIC
Table of Contents
- DATALOGIC BLADE 1D Reader Scanners
- Product Usage Instructions
- Connections
- Frequently Asked Questions
- Q: How do I adjust focus on Blade 200 models?
- INSTALLATION PROCEDURE
- PRODUCT OVERVIEW
- CONNECTIONS
- TECHNICAL FEATURES
- COMPLIANCE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DATALOGIC BLADE 1D Reader Scanners
Specifications
- Product Name: BLADETM Image-Based Industrial Reader
- Manufacturer: Datalogic S.r.l.
- Model: Blade 200
- Country of Origin: Italy
- Power Supply Input Voltage: +Vdc, -Vdc
- Connectors:
- Power, COM, and I/O Connector: M12 male 17 pin
- Ethernet Connector 1: 4 pin
- Ethernet Connector 2: 4 pin
- SD Card Slot
Product Usage Instructions
- Mounting: Physically mount the Blade reader in the desired location.
- Electrical Connections: Make the necessary electrical connections following the provided pin functions.
- Configuration: Configure the reader using either the X-PRESS interface for simple configuration or the DL.CODE software configuration program for complete configuration.
HMI X PRESSTM Interface
In normal operating mode, the colors and meanings of the five LEDs are as follows:
LED Color | LED Meaning |
---|---|
READY (green) | Indicates the device is ready to operate. |
BACKUP (green) | Indicates that a valid Backup is present on the SD card. |
TRIGGER (yellow) | Indicates the status of the reading phase. |
COM (yellow) | Indicates active communication. |
STATUS (red) | Blinks together with Ready LED to indicate an active diagnostic |
message.
Connections
Ethernet Models:
- M12 Male 17 Pin Connector for POWER, COM, and I/O
- Ethernet Connector (4 pin)
Fieldbus Models:
- M12 A-Coded Male 5 Pin Connector for POWER and I/O
Frequently Asked Questions
Q: Where can I download the complete Product Reference Guide? A: You can download the Product Reference Guide by scanning the QR code provided in the manual or by visiting www.datalogic.com.
Q: What do the different LED colors on the Blade reader indicate? A: The green LED indicates readiness, the yellow LED indicates reading status, and the red LED indicates communication status.
Q: How do I adjust focus on Blade 200 models?
A: For Blade 200 models, focus adjustment can be done using the dedicated adjustment feature mentioned in the manual.
Datalogic S.r.l.
Via San Vitalino 13
40012 Calderara di Reno (BO)
Italy
Tel. +39 051 3147011
Fax +39 051 3147205
©2023 Datalogic S.p.A. and/or its affi liates
All rights reserved. Without limiting the rights under copyright, no part of
this docu-mentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A. and/or its
affi liates.
Owners of Datalogic products are hereby granted a non-exclusive, revocable
license to reproduce and transmit this documentation for the purchaser’s own
internal busi-ness purposes. Purchaser shall not remove or alter any
proprietary notices, inclu-ding copyright notices, contained in this
documentation and shall ensure that all notices appear on any reproductions of
the documentation.
Electronic versions of this document may be downloaded from the Datalogic
website (www.datalogic.com). If you visit our website and would like to make
comments or suggestions about this or other Datalogic publications, please let
us know via the “Contact” page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual
that is complete and accurate, however, Datalogic shall not be liable for
technical or editorial errors or omissions contained herein, nor for
incidental or consequen-tial damages resulting from the use of this material.
Datalogic reserves the right to change any specifi cation at any time without
prior notice.
Trademarks
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A.
in many countries, including the U.S.A. and the E.U.
Blade, ID-NET, DL.CODE, and X-PRESS are trademarks of Datalogic S.p.A. and/or
its affi liates. All other brand and product names may be trademarks of their
respective owners.
NOTE: This Quick Reference Guide does not replace the Product Reference Guide.
Download the Product Reference Guide by reading the QR code here or at
www.datalogic.com.
NOTE: Scan this QR code to download the multilingual quick guide.
INSTALLATION PROCEDURE
- Physically mount the Blade reader.
- Make the necessary electrical connections.
- Confi gure the reader using the X-PRESS interface (simple confi gura-tion) or the DL.CODE so ware confi guration program (complete con-fi guration).
HMI X-PRESS™ INTERFACE
In normal operating mode the colors and meaning of the fi ve LEDs are illu-
strated in the following table:
READY (green) | indicates the device is ready to operate. |
---|---|
BACKUP (green) | indicates that a valid Backup is present on the SD card. |
TRIGGER (yellow) | indicates the status of the reading phase. |
COM (yellow) | indicates active communication. |
STATUS (red) | blinks toghether with Ready led to indicate an active dia- |
gnostic message.
During the reader startup (reset or restart phase), all the LEDs blink for one second.
The single push button gives immediate access to the following relevant functions:
- Aim sets the device in continuous reading mode, with all code symbologies enabled, in order to easily check out were the reading area is, and correctly aim the reader.
- Test Mode with bar graph visualization to check static reading performance.
- Learn to self-detect and auto-confi gure for reading an unknown barcode (by type and length). Only one symbology type can be saved using this method. Performing Autolearn on a second symbology will overwrite the fi rst one.
- Init to forcibly formatting the SD Card possibly inserted, and execute a backup on it.
PRODUCT OVERVIEW
Front models
1 | Reading Window |
---|---|
2 | HMI X-PRESS™ Interface |
3 | 360° Feedback |
4 | 90° Rotating Connector Block |
Side models
5 | Reading Window |
---|---|
6 | HMI X-PRESS™ Interface |
7 | 360° Feedback |
8 | 90° Rotating Connector Block |
Ethernet models
9 | Power – COM – I/O Connector (17 pin) |
---|---|
10 | Ethernet Connector (4 pin) |
11 | Focus adjustment (Blade 200 models only) |
12 | SD Card slot |
Fieldbus models
13 | Focus adjustment (Blade 200 models only) |
---|---|
14 | SD Card slot |
15 | Ethernet Connector 1 (4 pin) |
16 | Power – I/O Connector (5 pin) |
17 | Ethernet Connector 2 (4 pin) |
CONNECTIONS
Ethernet models
- Blade 200 models only
** DO NOT leave fl oating. See Reference Manual for connection details.
Fieldbus models
TECHNICAL FEATURES
| BLADE 100| BLADE 200
---|---|---
ELECTRICAL FEATURES
Power| |
Supply Voltage (Vdc)| 10 to 30 Vdc
Max Consumption (A)| 0.45| 0.50
Communication Interfaces| |
RS232| 2400 to 115200 bit/s| 2400 to 115200 bit/s
RS422 Full Duplex| –| 2400 to 115200 bit/s
ID-NET ™| Up to 1Mbaud
Ethernet| 10/100 Mbit/s
Inputs| Opto-coupled and polarity insensitive (see Product Reference
Guide for details)
Max Voltage| 30 Vdc
Max Input Current| 10 mA
Outputs| NPN or PNP short circuit protected (see Product Reference Guide
for details)
VOUT (ILOAD = 0 mA) Max.| 30 Vdc
VOUT (ILOAD = 100 mA) Max.| 3 Vdc
ILOAD Max| 100 mA
OPTICAL FEATURES
see Product Reference Guide for details
PHYSICAL FEATURES
Dimensions| H x W x L
x1xx Models (connector at 0°)| 83 x 68 x 38 mm (3.27 x 2.68 x 1.5 in)
x2xx, x3xx Models (connector at 0°)| 104 x 86 x 35.8 mm (4.1 x 3.38 x 1.41 in)
Weight| 310 g. (10.93 oz.)
Material| Aluminium
ENVIRONMENTAL FEATURES
Operating Temperature| 0 to 50 C (32 to 122 °F)
Storage Temperature| -20 to 70 C (-4 to 158 °F)
Max Humidity| 90% non-condensing
Vibration Resistance EN 60068-2-6| 14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz; 2
g @
70 to 500 Hz; 2 hours on each axis
Shock Resistance EN 60068-2-27| 30g; 11 ms; 3 shocks on each axis
Protection Class EN 60529| IP65
USER INTERFACE
LED Indicators| Power; Ready, Backup, Trigger, Com, Status; Ethernet Network;
(see Product Reference Guide for other LEDs)
Other| X-PRESS™ Keypad button
SOFTWARE FEATURES
READABLE CODE SYMBOLOGIES
1-D and stacked|
•PDF417 Standard and Micro PDF417| •Codabar
•Code 128 (GS1-128)| •Code 93
•Code 39 (Standard and Full ASCII)| •Pharmacode
•Code 32| • EAN-8/13 – UPC-A/E
•MSI| (including Addon 2 and Addon 5)
•Standard 2 of 5| •GS1 DataBar Family
•Matrix 2 of 5| •Composite Symbologies
•Interleaved 2 of 5|
Operating Mode|
CONTINUOUS, PHASE MODE|
Configuration Methods|
X-PRESS™ Human Machine Interface Windows-based SW (DL.CODE™) via Ethernet
Host Mode Programming sequences sent over Serial or Ethernet TCP interfaces
Parameter Storage|
Permanent memory (Flash)|
COMPLIANCE
Power Supply
This product is intended to be installed by Qualifi ed Personnel only.
This product is intended to be connected to a UL Listed Direct Plug-in Power
Unit marked LPS or “Class 2”.
LED Safety
LED illuminators integrated are classifi ed as “EXEMPT RISK GROUP” according to
IEC62471.
EUROPEAN DECLARATION OF CONFORMITY
Hereby, Datalogic S.r.l. declares that the full text of the European Declara-
tion of Conformity is available at: www.datalogic.com. Select the Support &
Service > Downloads > Product Certifi cations link where you can search for
your specifi c product certifi cation.
UKCA DECLARATION OF CONFORMITY
Hereby, Datalogic S.r.l. declares that the full text of the UKCA Declaration
of Conformity is available at: www.datalogic.com. Select the Support & Service
Downloads > Product Certifi cations link where you can search for your specifi c product certifi cation.
PATENTS
See www.patents.datalogic.com for patent
list.
This product is covered by one or more of the following patents:
Design patents: EM002486514, EM015009660, GB9002486514 0001/0003, USD743397,
USD800120, ZL201430537609.3
Utility patents: DE202015004175, EP2517148B1, EP2616988B1, EP2649555B1,
EP2795534B1, EP3016028B1, EP3092597B1, IT0282308, US10133895, US10796117,
US7433590, US8245926, US8888003, US8915443, US9122939, US9355292, US9361503,
US9430689, US9798948, ZL200980163411.X, ZL201080071124.9, ZL201180044793.1,
ZL201280010789.8, ZL201480072926.X
WEEE STATEMENT
Waste Electrical and Electronic Equipment (WEEE) Statement
For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.datalogic.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>