helo Roxx Pure Electric Sauna Heater Instruction Manual

August 10, 2024
HELO

helo Roxx Pure Electric Sauna Heater

Specifications

  • Model: 7013519 314 SKLT 75 F
  • Sauna Type: Genuine Finnish sauna
  • Control Center: Pure 314 SKLT 75-1

Product Information

  • The genuine Finnish sauna provides a traditional sauna experience with high-quality materials and design.
  • The control center, Pure 314 SKLT 75-1, ensures precise control over sauna settings for optimal comfort.

Usage Instructions

  • Before using the sauna, ensure proper ventilation in the sauna room and adjacent areas.
  • Install recommended ventilation systems as shown in the provided diagrams. Ensure adequate airflow for a comfortable sauna experience.
  • Follow the provided guidelines for installing and preparing the sauna heater. Check the power rating of the heater and its compatibility with the sauna volume.
  • If using the remote control, follow the instructions for connecting and configuring the remote control system for convenient sauna operation.

FAQ

  • Q: What is the recommended power rating for the sauna heater?
  • A: The recommended power rating varies based on the sauna’s volume. Refer to for specific guidelines.
  • Q: How do I install the door switch?
  • A: The door switch should be placed at the bottom of the sauna door with the magnetic part on the door. Refer to Figure 7 for proper positioning.

Check before taking a sauna bath

  1. The sauna room is suitable for taking a sauna bath.
  2. The door and the window are closed.
  3. The sauna heater is topped with stones that comply with the manufacturer’s recommendations, the heating elements are covered with stones, and the stones are piled sparsely.

NOTE! Ceramic rocks are not allowed.
The heater’s main switch is located at the bottom of the heater, on the right side as seen from the front.
The main switch is marked with a 0 – 1 sticker.

Sauna room
The walls and ceiling of a sauna room should be thermally well insulated. All surfaces that store heat, such as tiled and plastered surfaces must be insulated. It is recommended to use wooden panel cladding inside the sauna room. If there are heat storage elements in the sau-na room, such as decorative stone, glass etc., note that these elements may extend the pre- heating period even though the sauna room is otherwise well insulated (see page 6, section 2,7 Preparing for sauna heater installation).

Operation of the sauna heater controls
This appliance may not be used by children aged less than eight years, by persons with reduced physical, sensory or mental capabilities, or by persons lacking experience and knowledge regarding its operation only if such have been given instructions on the safe use of the device and the risks involved. Children must not be allowed to play with the appliance or to clean and service it without supervision. (7.12 EN 60335-1:2012)

Operation of the sauna heater controls

  • Refer to the specific control panel operating instructions.
  • Pleasant, smooth sauna bath temperature is about 70 °C.
  • If you encounter any problems, please contact the manufacturer’s warranty service shop.
  • For additional information about enjoying a sauna bath, please visit our website at: www.Sauna360.com

Heating the sauna

  • Before turning the sauna heater on, make sure the sauna room is suitable for taking a sauna bath. When heated for the first time, the sauna heater may emit some odour. If you detect any odour while the sauna heater warms up, disconnect the sauna heater briefly, and air the room. Then turn the sauna heater back on.
  • You should turn the sauna heater on roughly an hour before you plan to take a sauna bath, so that the stones have time to heat up properly and the air warms up evenly in the sauna room.
  • If you encounter any problems, please contact the manufacturer’s warranty service shop.
  • Pleasant, smooth sauna bath temperature is about 70 °C.
  • Do not put any objects on the sauna heater. Do not dry clothes on the sauna heater or anywhere in its vicinity.

Recommended sauna room ventilation

  1. Sauna room
  2. Washroom
  3. Electric sauna heater
  4. Exhaust valve
  5. Exhaust flue or channel
  6. Door to the sauna room
  7. A ventilation valve can be installed here to be kept closed while the sauna is heated and during bathing.

Inlet vent can be positioned in the A zone. Make sure the incoming fresh air will not interfere with (i.e. cool down) the sauna heater’s thermostat near the ceiling.
The B zone serves as the incoming air zone, if the sauna room isn’t fitted with forced ventilation. In this case, the exhaust valve is installed min 1m higher than the inlet valve.
DO NOT ISTALL INLET VALVE WITHIN ZONE C, IF THE SAUNA HEATER’S CONTROL THERMOSTAT IS LOCATED IN THE SAME ZONE.

Installing the sensor near a supply air vent

  • The sauna room air should be exchanged six times in an hour. The diameter of the supply air pipe should be between 50 and 100 mm.
  • A circular air supply vent (360°) must be installed at least 1000 mm away from the sensor.
  • An air supply vent with a flow-directing panel (180°) must be installed at least 500 mm away from the sensor. Air flow must be directed away from the sensor.

Ceiling installation of the sensor

  • Ceiling installation of the sensor In-ceiling installation, a 5-mm hole must be drilled to the sensor case to allow any condensed water to drain.
  • Do not spray water directly towards the sensor or splash water at it with a sauna scoop.

Installing the Extra NTC sensor

  • The additional OLET 31 sensor is connected to the Ext NTC connector on the RJ10 circuit board. For more details, refer to the switch diagram. The additional sensor is installed on the sauna room wall no more than 500 mm from the ceiling. Once the additional sensor has been connected to the circuit board, it is automatically activated. This means that the temperature shown on the control panel is measured by the additional sensor.
  • The primary sensor installed above the sauna heater only has the limiter circuit that limits the maximum temperature to 110 °C. Even if the temperature is set to 110 °C on the control panel, the maximum temperature that can be shown on the panel is approximately 90 °C, as the primary sensor above the heater limits the maximum temperature to 110 °C. Depending on individual preferences, the temperature of a sauna room is typically set between 70 and 80 °C.

Sauna heater stones
Quality stones meet the following requirements:

  • Sauna stones should withstand heat and heat variation caused by vaporization of the water thrown on the stones.
  • Stones should be rinsed before use to avoid odour and dust.
  • Sauna stones should have an uneven surface to supply a larger surface for the water to evaporate from.
  • Sauna stones should be large enough, to allow good ventilation between the stones. This extends the useful life of the heating elements. It is recommended to use Vulkanite stones in the size of 5cm-10cm. E.g. Helo product 0043020
  • Sauna stones should be piled sparsely in order to enhance ventilation between the stones. Do not bend the heating elements together or against the frame.
  • Rearrange the stones regularly (at least once a year) and replace small and broken stones with new, larger stones.
  • Empty the stone compartment regularly, at least once a year in private use, remove small and broken stones and replace them with new ones.
  • In commercial use this operation must be performed at least every second month.
  • Stones are piled so that they cover the heating elements. Do not, however, pile a large heap of stones on the heating elements. For a sufficient amount of stones refer to Table 1 on page 7. Any small stones in the package of stones must not be piled on the sauna heater.
  • The warranty does not cover defects resulting from poor ventilation caused by small and tightly packed stones.
  • Structural clay tiles are not allowed. They may cause damage to the sauna heater that will not be covered by the warranty.
  • Do not use soapstone as sauna rocks. Any damages resulting from this will not be covered by the stove warranty.
  • Do not use lava stone as sauna rocks. Any damages resulting from this will not be covered by the stove warranty.

DO NOT USE THE HEATER WITHOUT STONES

If the sauna heater will not heat up

  • If the sauna heater will not heat up, please check that:
    • the power is on;
    • the main fuses of the sauna heater are intact;
    • is there any error messages on the control panel? In case of an error message on the control panel, please refer to the control panel instructions.
  • THE PERSON INSTALLING THE SAUNA HEATER SHOULD LEAVE THESE INSTRUCTIONS AT THE PREMISES FOR THE FUTURE USER.

Preparing for sauna heater installation

  • Check the following before installing the sauna heater.
  • The ratio of the heater’s input (kW) and the sauna room’s volume (m3). Volume recommendations are presented in table 1 on page 7. The minimum and maximum volumes must not be exceeded.
  • The sauna room height must be a min. of 1900 mm.
  • Uninsulated and masonry stone walls extend the preheating time. Each square meter of plastered ceiling or wall surface adds 1.2 m3 to the sauna room’s volume.
  • Check page 9 Table 2 for a suitable fuse size (A) and the correct diameter of the power supply cable (mm²) for the sauna heater in question.
  • Conform to the specified safe clearance around the sauna heater. Please refer to page 7 table 1. The sauna heater is leveled by the adjustable legs
  • There should be enough room around the sauna heater controls for maintenance purposes. Also a doorway can be considered as a maintenance area.
  • Only a single sauna heater is allowed per sauna room

Installation

  • Follow the safety clearance specifications on page 7 when installing the sauna heater. A thin panel is not a suitable mounting base; the mounting base must be reinforced with timber behind the panel. The minimum clearances specified on page 7 must be followed even if the sauna room wall materials are incombustible.
  • Walls or ceilings must not be clad with fiber-reinforced plasterboard or other light-weight cladding, because they may cause a fire hazard.
  • Install the sauna heater so that the sign and the warnings can be read even after the installation.

Sauna heater safety clearances

  • For wall installation, install the OLET 31 sensor 40 mm from the ceiling on the centre line of the heater.
  • For ceiling installation, install it above the heater, and in line with the centre line of the heater. Do not install the sensor anywhere else.

Various stages of the installation

  • With the adjustment legs driven in, the mounting height of the sauna heater wall mount is 750mm from the floor.
  • The adjustment legs can be adjusted 15mm in case the floor is inclined. After the mounting, check that both adjustment legs are evenly against the floor.
  • The distance between the holes for the mount in the wall is 240mm.

Parts for wall mounting:

  • sauna heater locking wedges (A) 2 pcs

  • wall fastening (B) 1 pc

  • sheet metal screw 4.2 x 13mm 2 pcs

  • build screw 6 x 40mm 2 pcs

  • Pass the locking wedges (A) through the holes in the heater so that the ingoing part is turned upwards.

  • The wall mount (B) is attached to the wall so that the holes where the locking wedges are secured to are upwards.

  • The mount may also be attached directly to the sauna heater.

  • Mark the locations of the screws on the wall and, if necessary, drill small holes and mount the sauna heater then to the wall with the screws provided.

  • The picture shows how the wall mount should be attached to the sauna heater. The locking wedges are attached to the wall mount with the sheet metal screws.

Connection of the sauna heater to the mains

  • The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations. The sauna heater is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) cables or a corresponding type. Other output cables (signal lamp, electric heating toggle) must also adhere to these recommendations. Do not use PVC insulated cable as a connection cable for the sauna heater.
  • A multipolar (e.g. 7-pole) cable is allowed, if the voltage is the same. In the absence of a separate control current fuse, the diameter of all cables must be the same, i.e. in accordance with the front fuse.
  • The connecting box on the sauna wall should be located within the minimum safety clearance specified for the sauna heater. The maximum height for the connection box is 500 mm from the floor. See page 10. Figure 4 Locating the connecting box for the connection cable in the sauna room
  • If the connection box is located at over 500mm distance from the heater, the maximum height is 1000mm from the floor..

NO T E: Controlling the lights in the sauna with the circuit board is only possible with resistive loads (incandescent light bulbs). The circuit board relay cannot withstand capacitive loads (switched-mode power supply units). If the lighting fixtures in the sauna have transformers, for example LED or halogen lamps, the stove circuit board’s relay control must be fitted with a separate relay or contactor for controlling the lights.
Sauna heater insulation resistance:
The sauna heater heating elements may absorb moisture from air, e.g. during storage. This may cause leakage currents. The moisture will be gone after a few heating sessions. Do not connect the heater power supply through a ground fault interrupter.
However, adhere to the effective electrical safety regulations when installing the sauna heater.

Electric heating toggle
Electric heating toggle applies to homes with an electric heating system.
Sauna heater has connections (marked N-55) for controlling the electric heating toggle. Connectors N-55 and the heating elements are simultaneously live (230V). The sauna heater thermostat also controls the heating toggle. In other words, home heating turns on once the sauna thermostat cuts power off the sauna heater.

Locating the connecting box for the connection cable in the sauna room

A = Specified minimum safety clearance

  1. Recommended location for the connecting box
  2. Silumin box recommended in this area.
  3. This area should be avoided. Always use a silumin box.

In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connection box must be clear of obstacles. When installing the connection box to zones 2 or 3, refer to the instructions and regulations of the local energy supplier.

Locat Remote controlling

  • The Heater can be remotely controlled by connecting a closed contactor, which can be pulse triggered, to connectors 3 and 4 of a RJ10 circuit board. The recommended cable size is AWG 24 or 26. The maximum length of an AWG 24 cable is 200 m when using a Pure controller.
  • The maximum length of an AWG 26 cable is 130 m when using a Pure controller.

Coupling order of RJ 10 connectors to circuit board

NOTE: Incorrect connections may break a circuit board.

Wiring diagram

  1. Power input
  2. Alternation of electric heating
  3. Sauna lighting
  4. Control panel
  5. Sensor
  6. Door switch
  7. Remote control
  8. Capteur appoint

Door switch

  • The door switch refers to the switch on the sauna door. This switch complies with regulations. Public and private saunas must have a door switch, i.e. saunas where the heater can be switched on from outside the sauna, e.g. using an On/Off button or a similar method.
  • The control panel automatically registers when the door switch is connected to the heater’s OLEA 99 circuit board. When using the sauna for the first time after the installation, close the door to the sauna room and turn on electricity using the heater’s main switch.
  • If the door is opened before the heating sequence is started, (pre-set heating) automatic use (remote use) is disabled after one minute. The door must be closed and the function restarted from the control panel.
  • If the door has been left open for more than five minutes while the heater is on, the heater is automatically turned off.
  • The heater can be turned on again from the control panel after the door is closed. The fault indicator light, if installed, will start flashing. See installation instructions below.

Door switch instructions for installation and connection

  • The door switch is installed outside the sauna room on the upper edge of the door, at least 300 mm from the inner corner.
  • The switch part is installed on the door frame and the magnet is installed on the door. The distance between the switch and the magnet is 18 mm.
  • When the door switch is installed on the top part of the door, Sauna360 recommends using the Sauna360 model with product number 0043233, SSTL 8260371.
  • When the door switch is installed on the bottom part of the door, Sauna360 recommends using the Sauna360 model with product number SP11000326, SSTL 8263280.
  • See the installation and user instructions supplied with the heater for instructions.

Principle image when Pure is used as control panel

Helo-WT technology in a Roxx Pure heater

  • Helo-WT (Helo Water Tech) uses the heater’s thermal energy to heat water and raise the moisture level without a separate heat source. Moisturised air improves the sauna climate, and various fragrances and salts can be evaporated to make the sauna experience more enjoyable.
  • A water container with a lid is delivered with the heater; the container can be installed between the heating elements. The water tank can be installed when approximately 2/3 of the heater stones have been stacked.
  • The tank has a capacity of approximately two litres. Bringing water to the boil when the tank is full takes approximately 1-2 hours depending on the set temperature.
  • It is recommended to pour water into the tank when the heater is turned off. Water is poured through the grate on the lid. You can pour less water into the tank if the bathing time is shorter.
  • The water tank must be removed and impurities, such as limescale etc. removed every so often. The stones surrounding the tank must be removed during cleaning, so that the tank can be lifted more easily.
  • When the water is boiling, the moisture levels in the sauna remain high. This means that the temperature can be kept lower while still experiencing pleasant heat. More heat and moisture can, if necessary, be created by throwing water on the stones on top of the heater.
  • Mild fragrance essences, suitable for heater use, can be put in the water tank.
  • You can, for example, put mountain salt crystals on the lid of the water tank. They dissolve into the steam and evaporate into the air. If mountain salt crystals are placed in the water tank, the salinity of the water will remain 26%.
  • Do not use the tank without water.
  • Remove the tank from the heater if the steam function is unpleasant. The tank will deform if it overheats.
  • If you remove the tank from the heater, replace it with sauna stones.

Helo Roxx Pure spare part list

ROHS

Instructions for environmental protection

  • This product must not be disposed with normal household waste at the end of its life cycle. Instead, it should be delivered to a collecting place for the recycling of electrical and electronic devices.
  • The symbol on the product, the instruction manual or the package refers to this.
  • The materials can be recycled according to the markings on them. By reusing, utilizing the materials or by otherwise reusing old equipment, you make an important contribution for the protection of our environment.
  • Please note that the product is returned to the recycling center without any sauna rocks and soapstone cover.
  • Please contact the municipal administration with inquiries concerning the recycling place.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals