Spanet SV-4T Support Hub Controller User Guide
- August 9, 2024
- spanet
Table of Contents
Spanet SV-4T Support Hub Controller
OVERVIEW
DISPLAY MODE ICONS
- Water Temperature
- Set Temperature
- Clock
MENU ICONS
- Sleep timer menu icon
- Light menu icon
- Blower menu icon
STATUS ICONS
- Keypad locked
- Sanitise cycle operating
- Filtration cycle operating
- Fault conditions have occured
USING INSTRUCTION
CHANGING LIGHT MODES
When the light is first turned on the display will show the current light mode
in use. Press ( or button to step through the choice of light modes:
- WHTE
- White Light
- UCLR
- User Colour
- FADE
- Fade Effect
- STEP
- Step Effect
- PARTY
- Party Effect
CHANGING LIGHT SPEED OR LIGHT COLOUR
Depending on the light mode selected the Light (spd/cir) button will activate one of three light mode option screens.
- CL: XX
- User Colour Number
- L.SPD
- Light Transition Speed
- L.BRT
- Light Brightness
- Press the button to adjust each setting.
- Press OK button to save each setting and move to the next setting.
Note: All light settings are saved for future ON / OFF use.
FULL KEYLOCK
Press and hold this button combination until LOCK appears on the display:
Repeat the button combination to unlock.
Note: Once locked if any button is pressed the keystroke will be ignored and the display will show LOCK.
PARTIAL KEYLOCK
Press and hold this button combination until LOCK appears on the display:
Repeat the button combination to unlock.
Note: Once locked only pumps, blower, light, and sanitise buttons can be used. Access to all other buttons is disabled.
SETUP MENU
- The setup menu allows customization of the adjustable controller settings. Menu access and item adjustments are carried out as follows:
- Press and hold buttons together until [MODE] is displayed.
- Press to navigate through setup menu items.
- Press OK to enter item adjustment.
- Press on to adjust the setting.
- Press OK to confirm the setting and exit.
All setup menu items follow the same adjustment procedure. Menu items that can be adjusted are as follows:
[MODE] OPERATING MODES
Operating modes affect heating and filtration behavior. The choices are:
- NORM Normal heating & filtration
- AWAY Heating disabled. Filtration reduced to 1hr p/day.
- WEEK Mon-Thu (works like AWAY mode) Fri-Sun (works like NORM mode)
[FILT] DAILY FILTRATION TIME
Adjust the hours of filtration per day. Filtration limits differ for the type
of pump:
- Circ Pump (2A or less) 1-24 hrs
- Jet Pump (2spd or 1spd) 1-8 hrs
[F.CYC] FILTRATION CYCLES
This setting defines how often filtration cycles occur. Filtration can be set
to run every 1/2/3/4/6/8/12 or 24 hrs
[SNZE] SLEEP TIMERS
Used to disable automatic heating and filtration during certain times of day
or night. Upon entering the SNZE menu there are four choices:
- SNZ
- Sleep Timer #1
- SNZ
- Sleep Timer #2
- R. SET
- Reset timers to default
- EXIT
- Exit the sleep timer menu
Only one sleep timer needs to be set however two timers are provided to facilitate different sleep settings on different days. Each sleep timer setting consists of a weekday setting, start time, and stop time (refer to below).
- x. DAY Day(s) of operation
- x.BGN Sleep timer begins time
- X.END Sleep timer end time
Use the Up, Down & OK buttons to adjust and confirm each setting.
[P.SAV] POWER SAVE (off-peak)
Reduce operating costs by limiting filtration and heating to occur during
cheaper off-peak power periods. There are three P.SAV modes:
- OFF P.SAV disabled
- LOW Off-peak filtration only
- HIGH Off-peak filtration & heating
Once P.SAV mode is selected the begin and end times of the PEAK power tariffs must be set so the control knows NOT to operate during those peak hours.
- BGN Peak power begins time
- END Peak power end time
[W.CLN] AUTOMATIC SANITISE
Adjust the start time of the 10-minute automatic daily sanitizing cycle. The
setting can be adjusted from 0:00 to 23:59.
[D.DIS] DEFAULT DISPLAY MODE
Used to adjust the default display mode shown on the keypad. Setting choices:
- W.TMP Water Temperature
- S.TMP Set Temperature
- TIME Clock
[T.OUT] LOAD TIME OUTS
All accessory loads (pumps & blowers) automatically turn off after a time-out
period has elapsed. Adjust the time-out period from 10-60 minutes.
[H.PMP] HEAT PUMP MODE
Defines heat pump operating mode:
- AUTO Heat & Cool
- HEAT Heat Only
- COOL Cool Only
- OFF Heat Pump Disabled
[H.ELE] ELEMENT BOOST
Enables/disables SV electric element to boost heat pump heating if the water
temperature is 2°C or more below set temperature point OR the heat pump has
been operating for more than 1hr.
- OFF Element disabled (heat pump only)
- ON SV element + heat pump