spanet SV2 Spa Pool Controller
DISPLAY MODE ICONS
MENU ICONS
- Sleep timer menu icon
- Light menu icon
- Blower menu icon
STATUS ICONS
- Keypad locked
- Sanitise cycle operating
- Filtration cycle operating
- Fault condition has occured
Overview
CHANGING LIGHT MODES
When light is first turned on the keypad will display the light mode menu
showing current light mode in use.
Press button to step through choice of light modes:
- WHTE White Light
- UCLR User Colour
- FADE Fade Effect
- STEP Step Effect
Press button to confirm light mode selection.
Dependant on light mode selected the keypad will then display one of three light mode option screens.
- CL:xX User Colour Number
- L.SPD Light Transition Speed
- L.BRT Light Brightness
Press button to adjust each setting.
Press button to save each setting and move to the next setting.
Note: All light settings are saved for future ON / OFF use.
FULL KEYLOCK
Press and hold this button combination until LOCK appears on the display:
Note: Once locked if any button is pressed the key stroke will be ignored and the display will show LOCK.
PARTIAL KEYLOCK
Press and hold this button combination until LOCK appears on the display:
Repeat button combination to unlock.
Note: Once locked only pumps, blower, light and sanitise buttons can be used. Access to all other buttons is disabled.
SETUP MENU
The setup menu allows customisation of the adjustable controller settings.
Menu access and item adjustments are carried out as follows:
All setup menu items follow the same adjustment procedure. Menu items that can be adjusted are as follows:
[MODE] OPERATING MODES
Operating modes effect heating and filtration behaviour.
The choices are:
- NORM Normal heating & filtration
- AWAY Heating disabled. Filtration reduced to 1hr p/day.
- WEEK Mon-Thu (works like AWAY mode) Fri-Sun (works like NORM mode)
[FILT] DAILY FILTRATION TIME
Adjust the hours of filtration per day. Filtration limits differ for type of
pump:
- Circ Pump (2A or less) 1-24 hrs
- Jet Pump (2spd or 1spd) 1-8 hrs
[F.CYC] FILTRATION CYCLES
This setting defines how often filtration cycles occur. Filtration can be set
to run every 1/2/3/4/6/8/12 or 24 hrs
[SNZE] SLEEP TIMERS
Used to disable automatic heating and filtration during certain times of day
or night. Upon entering SNZE menu there are four choices:
- 1.SNZ Sleep Timer #1
- 2.SNZ Sleep Timer #2
- R.SET Reset timers to default
- EXIT Exit sleep timer menu
Only one sleep timer needs to be set however two timers are provided to facilitate different sleep settings on different days. Each sleep timer setting consists of a week day setting, start time and stop time (refer below).
- x.DAY Day(s) of operation
- x.BGN Sleep timer begin time
- x.END Sleep timer end time
Use the Up, Down & OK buttons to adjust and confirm each setting.
[P.SAV] POWER SAVE (off peak)
Reduce operating costs by limiting filtration and heating to occur during
cheaper off peak power periods. There are three P.SAV modes:
- OFF P.SAV disabled
- LOW Off-peak filtration only
- HIGH Off-peak filtration & heating
Once P.SAV mode is selected the begin and end times of the PEAK power tariff must be set so the control knows NOT to operate during those peak hours.
- BGN Peak power begin time
- END Peak power end time
[W.CLN] AUTOMATIC SANITISE
Adjust the start time of the 10 minute automatic daily sanitise cycle. Setting
can be adjusted from 0:00 to 23:59.
[D.DIS] DEFAULT DISPLAY MODE
Used to adjust the default display mod shown on the keypad. Setting choices:
- W.TMP Water Temperature
- S.TMP Set Temperature
- TIME Clock
[T.OUT] LOAD TIME OUTS
All accessory loads (pumps & blowers) automatically turn off after a time out
period has elapsed. Adjust the time out period from 10-60 minutes.
[H.PMP] HEAT PUMP MODE
Defines heat pump operating mode:
- AUTO Heat & Cool
- HEAT Heat Only
- COOL Cool Only
- OFF Heat Pump Disabled
[H.ELE] ELEMENT BOOST
Enables/disables SV electric element to boost heat pump heating if the water
temperature is 2°C or more below set temperature point OR the heat pump has
been operating for more than 1hr.
- OFF Element disabled (heat pump only)
- ON SV element + heat pump