FRIEDRICH F-Series Commercial Split Heat Pump Owner’s Manual

August 10, 2024
FRIEDRICH

FRIEDRICH F-Series Commercial Split Heat Pump

Standard Features

  • ScrScroll Comproll Compressorsessors
  • StandarStandard Indoor Blower VFDd Indoor Blower VFD
  • Indoor and Outdoor Copper TIndoor and Outdoor Copper Tube / Aluminum Fin Coilube / Aluminum Fin Coil
  • Separable Air Handler for Easier InstallationSeparable Air Handler for Easier Installation
  • Air Handlers with Convertible AirflowAir Handlers with Convertible Airflow
  • Shipped with a NitrShipped with a Nitrogen Holding Charogen Holding Charge
  • RPCY models for use with matching RHCYP modelsRPCY models for use with matching RHCYP models
  • Designed for A2L designed for A2L refrigerant R-454Befrigerant R-454B

Information provided for pre-sale only. Products will not be produced or shipped until ratings are certified to the Department of Energy.

Preliminary Information and Accessories

Preliminary information based on preliminary estimates. Not a representation of energy use or efficiency of these models.

Specification Unit RPCY2090 RPCY2120
Matching Air Handler Model RHCYP2090
Gross Cooling Capacity Btu/h [kW] 85,500 [25.1] 114,000

[33.4]
Net Sensible Capacity| | Btu/h [kW]| 62.215 [18.2]| 84,181 [24.7]
Net Latent Capacity| | Btu/h [kW]| 23,285

[6.8]| 29,819 [8.7]
EER up to| 11.0| 11.0
IEER up to| 14.2| 14.2
COP at 47°F / 43°F up to| 3.4| 3.4
COP at 17°F / 15°F up to| 2.25| 2.25
MCA (208/230v / 460v / 575v)| 39 / 17 / 13| 44 / 24 / 21
MCA (208/230v / 460v / 575v)| 60 / 25 / 20| 70 / 35 / 30
Rated Indoor Airflow| CFM| 2,875| 4,050
Estimated Weight| RPCY| lbs. [kg]| 389 [150]| 600 [203]
RHCYP| lbs. [kg]| 330 [150]| 447 [203]
Accessories
MERV 13 Filter (For Air Handlers)| RXMF-M13A11625 (1x16x25)
RXMF-M13A21625 (2x16x25)
MERV 8 Filter (For Air Handlers)| RXMF-M08A11625 (1x16x25)
RXMF-M08A21625 (2x16x25)

  • Low Ambient Control RXAD-A08

Model Number

  • R P C Y 2 090 C A Z

Nomenclature

  • 1 2 3 4 5 678 9 10 11

Heat Pumps

  • 1 – Brand
    • R = Friedrich
  • 2 – Unit Type
    • P = Heat Pump
  • 3 – Cabinet Type
    • C = Commercial
  • 4 – Refrigerant
    • Y = R-454B
  • 5 – Cooling Configuration
    • 2 = 2-stage compressor
  • 6,7,8 – Capacity
    • 090 = 7.5 Ton
    • 120 = 10 Ton
  • 9 – Voltage
    • C = 208/230 V, 3PH, 60Hz
    • D = 460 V, 3PH, 60Hz
    • Y = 575 V, 3 PH, 60 Hz
  • 10 – Minor Series
    • A = 1st Design
  • 11 – Compressor
    • Z = Scroll compressor

Model Number

  • R H C Y P 2 090 C A R

Nomenclature

  • 1 2 3 4 5 6 789 10 11 12

1 – Brand
R = Friedrich

2 – Unit Type
H = Air Handler

3 – Cabinet Type
C = Commercial

4 – Refrigerant
Y = R-454B

5 – Heat Type
P = Heat Pump

6- Airflow Configuration
2 = 2-Stage

7,8,9 – Capacity

  • 090 = 7.5 Ton
  • 120 = 10 Ton

10 – Electrical Designation

  • C = 208/230 V, 3 PH, 60 Hz
  • D = 460 V, 3 PH, 60 Hz Y = 575 V, 3 PH, 60 Hz

11 – Minor Series

  • A = 1st Design

12 – Drive

  • R = Belt Drive – VFD low static
  • S = Belt Drive – VFD medium static
  • T = Belt Drive – VFD high static

Diagrams

Information is provided for pre-sale purposes only. Products will not be produced or shipped until ratings are certified by the Department of Energy.

Friedrich is a part of the Rheem family of brands. In keeping with its policy of continuous progress & program improvement, Friedrich reserves the right to make changes without notice. © 2024 Rheem Manufacturing Company, all rights reserved. Friedrich trademarks are owned by Friedrich Air Conditioning LLC. Rheem trademarks are owned by Rheem Manufacturing Company. 06/24 • Form No. MFR-1142

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FRIEDRICH User Manuals

Related Manuals