Huepar RL300HVG Horizontal Vertical Rotary Laser Instruction Manual
- August 7, 2024
- Huepar
Table of Contents
Huepar RL300HVG Horizontal Vertical Rotary Laser
Operating Manual
Horizontal/Vertical Rotary Laser (Green beam/ Red beam)
RL300HG/ RL300HR
RL300HVG/RL300HVR
support@huepar.com
Thank you for purchasing Huepar RL300H/RL300HV Rotary Laser Level.
The instrument is intended for determining and checking precise horizontal and
vertical lines. The instrument is suitable for indoor and outdoor use.
Please read the Safety Instructions and User Manual thoroughly before using
this product.
Product Overview
- ON/OFF Button
- Slope Adjustment Buttons in X+ axis
- Manual/Slope Mode Button
- Manual/Slope Mode Indicator
- ADS Mode Indicator
- ADS Button
- Variable Rotation Speed Button
- Slope Adjustment Buttons in X-axis
- Power ON Indicator
- Battery Capacity Indicators
- Scanning Angle Selection
- Laser Window
- Control Keypad
- Type-C Charging Port
- 5/8″ -11 Threaded Mount
- Window for Plumb Beam (RL 300HV Only)
- Battery Compartment
- Battery indicator
- Type-C Charging Port on Battery
Safety Instructions
Before using this product, please read thoroughly and comply with the Safety Instructions. Failure to read and follow may void the warranty.
- WARNING!
- CLASS II LASER PRODUCT
- COMPLIES WITH 21 CFR 1040.10 AND 1040.11
- Max. Power Output: ≤ lmW
- Wavelength: 505nm-650nm
- LASER RADIATION:
- DO NOT STARE INTO BEAM.
- DO NOT DIRECT EYE EXPOSURE.
- AVOID VIEW WITH OPTICAL INSTRUMENTS.
ATTENTION:
Read all instructions prior to operating this laser tool. Do not remove any
labels from tool.
- While the product is in operation, be careful not to expose your eyes to emitting laser beam (Green/Red light source). Exposure to a laser beam for an extended time may be hazardous for your eyes.
- Do not attempt to view the laser beam by optical tools such as telescopes as serious eye injury may result.
- Do not disassemble or modify the laser in any way. Modifying the tool may result in hazardous Laser Radiation Exposure.
- Do not operate the laser around children or allow children to operate the laser. Serious eye injury may result.
- An exposure to the beam of a Class 2 laser is considered safe for a maximum of 2 seconds. Eyelid reflexes will normally provide adequate protection.
- The following label/print samples are placed on the product to inform of the laser class for your convenience and safety.
User Guide, Maintenance and Care
- When not in use please power OFF the tool.
- The laser tool is sealed and calibrated at the plant to the accuracy specified.
- It’s recommended to carry out an accuracy check before its first use and periodic checks during future use especially for precise layouts.
- Do not touch the glass window in case leaving any fingerprint on the window, which may affect the performance of the laser.
- Do not store the laser tool in direct sunlight or expose it to high temperatures. The housing and some internal parts are made of plastics and may become deformed at high temperatures.
- Exterior plastic parts may be cleaned with a damp cloth, NEVER use solvents. Use a soft, dry cloth to remove moisture from the tool before storage.
- Store the tool in its case when not in use. If storing for extended time, remove batteries before storage to prevent possible damage.
- Do not dispose of this product with household waste.
- Always dispose of batteries per local code.
- Please recycle in line with local provisions for the collection and disposal of electrical and electronic waste under the WEEE Directive.
- Charging and Battery Safety Please read thoroughly and comply with battery safety instructions and attention before charging. Fail to read and follow may result in personal injury, fire, and property damages if the battery is charged and/or used improperly.
Charging Precautions:
- Please use the charger or adapter provided by the manufacturer.
- Each charge time is about 4 hours, but not more than 24 hours.
- Please charge in 24 hours when the low battery or the laser tool turns off due to low power.
- The best charging temperature: 0°C to 20°C (32°F-68°F)
- If the lithium battery is not used for extended time, please charge the lithium battery once every 3 months, each charging time is not less than 6 hours
*Note:
- The battery can be charged directly instead of being charged in the device.
- The laser tool is not able to work while being plugged in directly if taking out the battery.
- Battery indicator(18)
- During charging, the battery indicator will light up in red.
- When charging is complete, the battery indicator will light up in blue
Battery Safety:
- DO NOT SHORT CIRCUIT. Short circuits may cause fire, and injury!
- Do not charge unattended.
- Do not disassemble, or modify the battery.
- Keep the battery away from children, and pets.
- Immediately discontinue use of the battery if the battery becomes abnormal/ deformed (emits an unusual smell, feels hot, changes color or shape, or appears abnormal in any other way). Please contact the manufacturer to replace it.
- Never charge or store the batteries inside your car. Extreme temperatures (low or high) might ignite the battery, and cause a fire.
- Do not place the battery in high-pressure containers, microwave ovens, or on induction cookware.
- Do not carry, or store the batteries together with hairpins, necklaces, or other metal objects.
- On (battery electrolytes) exposure to skin, flush with water immediately. If eye exposure occurs, flush with water for 15 minutes, and seek emergency care immediately.
Operation
-
Battery Installment
- STEP 1: Rotate counterclockwise as shown, and turn on the battery compartment.
- STEP 2: Install the battery, and rotate clockwise to tight the compartment .
-
Power ON/OFF
- Press the button to turn on automatic leveling in default. The power indicator(9) will light up.
- Press the button again to switch off the instrument. The power indicator will go out.
- Note : After power on, the current battery level will be displayed on Power indicator (10), ranging from 1 to 3 indicator(s).
-
Automatic Leveling Mode
- Press the Key ON/OFF to bring automatic leveling function. It takes about 15 seconds for leveling.
- The laser module will rotate at the speed of 600r.p.m in default.
- The indicator(4) and beam(s) will blink together if the instrument is placed improperly, or the slope of instrument exceeds the range (±5°). Please adjust the position or angle of the instrument.
- Note: When using automatic leveling mode, please place this instrument on a level surface.
-
Spinning
- Press the Key , to control the spinning speed of the laser module.
- Press the button , repeatedly, the spinning speed of the laser module will continuously change as follows: 0➔300➔600➔0 rpm.
-
Scan Mode
- Step 1: Press the button to change the spinning speed to O rpm.
- Step 2 : Press the button repeatedly, the angle of scanning will continuously change as follows: 0°➔ 10°➔ 45°➔ 90°➔ 180°➔ 0°.
- Note: The Detector cannot pickup the Laser beam when in scan mode.
-
Slope Adjustment
- When the instrument is upright for horizontal scanning, the slope of X-axis and Y-axis can be set.
- Press the button , the instrument enters the manual leveling mode. The indicator(4) will light up.
- Slope of X-axis
Aim the Xl-beam to the direction of the slope required then to adjust.
-
Press the button to move the laser beam up or down.
-
Exit slope adjustment mode
- Press the button again. The instrument will exit the slope adjustment mode and will self-leveling again. The indicator(4) will go out.
- Note :Slope of Y-axis and Slope of both X&Y-axis can be set by the remote control. See remote control section for further details.
-
Automatic Drift System (ADS)
- If the unit is running in self-leveling mode, press the Automatic Drift System (ADS) button on the face of the laser to turn on the Automatic Drift System.
- Once activated the green LED(S) will flash quickly firstly, then stop flash, now ADS is ON.
- If for example, the unit is knocked or caught by a gust of wind, the laser prism will stop rotating and the green ADS LED(5) will flash slowly to show an alarm condition. Check that your datums have not altered and if all is ok. Press the ADS button again & the laser will reset to AUTO level.
- This function is used to alert users that the laser has been disturbed. If this mode has not been turned on and the laser is disturbed, it is possible that although a level datum will continue to be produced it may be at a different height than before.
- Note : The ADS function cannot be activated when in manual mode doing Gradients or Slopes.
-
Vertical Leveling
- Place the unit on the rear lay-down mount on a firm, generally level surface. The mount is located on the opposing side of the keypad.
- Press the button , and the unit will power on and begin automatically self-leveling vertically. This process takes around 15 seconds. When the leveling process is completed, the laser will start spinning at 600rpm in default, indicating a vertically level datum.
- Note : You do not need to independently level the surface but it does need to be within ±5 deg of true
Remote Control
Overview
- Indicator
- Rotating Speed Selection
- Manual /Slope Mode
- Scanning Mode
- Anti-Clockwise Spin
- Clockwise Spin
- Manual Slope X&Y axis
Function Operation
- Spinning
- Continuous spinning
- Press the button to control the spinning speed of the laser module.
- Press the key repeatedly, the spinning speed of the laser module will continuously change as follows: 0➔300➔600➔0 r.p.m.
- Stepping spinning
- Press the button to change the spinning speed to 0 rpm.
- Press the button , the laser beam will step-move clockwise.
- Press the button , the laser beam will step-move counter-clockwise.
- Scan mode
- Step 1: Press the button to change the spinning speed to 0 rpm.
- Step 2: Press the button repeatedly, the angle of scanning will continuously change as follows: 0°➔ 10°➔ 45°➔ 90°➔ 180°➔ 0°.
Note :
- It’s able to press the button to rotate the position of the laser prism either clockwise or counter-clockwise.
- The Detector cannot pickup the Laser beam when in scan mode.
Slope Adjustment
Press the button , the instrument enters the manual leveling mode.
-
Slope of X-axis
Aim the Xl-beam to the direction of the slope required then to adjust.- Press the button to move the laser beam up or down.
-
Slope of Y-axis
- Aim the Yl-beam to the direction of the slope required then to adjust.
- Press the button to move the laser beam up or down.
-
Slope of both X&Y-axis
Proceed as above, but use all four Arrow Buttons as required. -
Exit slope adjustment mode
Press the button again. The instrument will exit the slope adjustment mode and will self-leveling again.
Detector
- Power supply
- The detector is powered by a 9V alkaline battery.
- Remove the battery door cover.
- Insert the battery according to polarity and replace the battery door.
- Mounting the staff clamp
- Insert the staff clamp screw into the staff clamp thread.
- Rotate the nut until the clamp is secured in place.
- Detector operation
- Switch the detector on by pressing button The speaker will beep once indicating the instrument is operating.
- To turn ON/OFF the speaker by pressing button The LCD screen will display the battery level, detection mode and speaker function.
- To change between coarse and fine mode, press button .
- Move the detector into the path of the laser beam.
- Hold the detector upright for horizontal beams. Rotate the detector 90° for vertical beams.
- The direction arrows or level line on the LCD screen will indicate the position of the laser beam. The detector will emit a constant beep once the level position has been located when the speaker function is on.
- Detector position for horizontal beam
Specifications
Model | RL300HVG | RL300HG | RL300HVR | RL300HR |
---|---|---|---|---|
Laser Type | Green Beam | Red Beam | ||
Laser Wavelength | 505-520nm | 635-650nm | ||
Laser Class | Class 2 (IEC/EN60825-l/2014), ,,;1mw | |||
Light Source | Laser Diode | |||
Horizontal/Vertical Accuracy | ±3mm at30m (±1/8 in at 100ft) | |||
Leveling Range | ±s□ | |||
Working Range (Radius) | 60m | 30m | ||
Working Range with Receiver (Diameter) | 800m | 700m | ||
Spinning Speed | 0, 300, 600 rpm | |||
Directional-Scanning Angle | 0°, 10 °, 45 °, 90 °, 180 ° | |||
Slope-adjusting Range | ±5° (Bi-directional) | |||
Remote controlling Distance | Approximately 30m | |||
Working Temperature | 0°C– S0°C(-4°F–104°F) | |||
Power Supply | Li-ion Battery 7.4V/2.6mAh | Li-ion Battery 7.4V/l.SmAh | ||
Hours in continuous use | About 14 hours | About 20 hours | ||
Water-proof | IP65 | |||
Mount Size | S/8”-11 | |||
Dimension | 245(L) X 200(W) X l 77(H)mm | |||
Weight | 1.54kg |
Note: Appearance and specifications may differ due to product improvement. Working distance varies depending on the operating environment.
Accuracy Check
-
The ambient temperature has the greatest influence. Especially temperature differences occurring from the ground upward can divert the laser beam. The deviations play a role in excess of approx. 65-ft (20m) measuring distance and can easily reach two to four times the deviation at 330-ft (l00m). Because the largest difference in temperature layers is close to the ground, the instrument should always be mounted on a tripod when measuring distances exceeding 65-ft (20m). If possible, also set up the instrument in the center of the work area.
-
Checking the Leveling Accuracy
-
Apart from exterior influences, device-specific influences (such as heavy impact or falling down) can lead to deviations. Therefore, check the accuracy of the instrument each time before starting your work. A free measuring distance of 100-ft (30m) on a firm surface is required for the check. A reversal measurement must be carried out over both axes X and Y (each positive and negative; 4 complete measurements).
- Mount the instrument in the horizontal position onto a tripod or place it on a firm and level surface near wall. Switch the instrument on. Position the X-axis to aim to a wall or target plate.
-
-
After the leveling, mark the center of the laser beam on wall (point Hl).
-
Rotate the instrument by 180°, allow it to level in and mark the center point of the laser beam on the wall (point H2}.
-
The difference D of both marked points Hl and H2 on wall is the actual deviation of the instrument for the measured axis. The value of D (deviation) should be less than 1/4-in (6mm).
-
Repeat the measuring procedure for the Y-axis. Position the Y·axis to aim to a wall or target plate.
-
After the leveling, mark the center of the laser beam on wall (point Hl).
-
Rotate the instrument by 180°, allow it to level in and mark the center point of the laser beam on the wall (point H2).
-
The difference D of both marked points Hl and H2 on wall is the actual deviation of the instrument for the measured axis.
-
The value of D (deviation) in either axis should be less than 1/4-in (6mm).
-
-
-
Checking the Vertical Alignment
A free measuring distance of 100-ft (30m) on a firm surface between two walls or targets A and Bis required for the check. Place the laser instrument in the laydown position on a flat, level surface.- Mount the instrument in the vertical position onto a tripod using mount accessory or place it on a firm and level surface near wall.
- Switch the instrument on. Position the up beam to aim at wall A or target plate.
- After the leveling, mark the center of the laser beam on wall A (point Hl).
- Rotate the instrument by 180° (without changing the height), allow it to level and mark the center point of the laser beam on wall B (point H2).
- Without turning the instrument, position it close to wall B by moving the tripod.
- After instrument levels, align the height of the instrument so that the center point of laser beam is exactly on point H2 of wall B.
- Rotate the instrument by 180° (without changing the height), allow it to level and mark the center point of the laser beam on wall A (point H3).
- The mark of point H3 should be marked in such a way that it is as vertical as possible (above or below) of point Hl.
- The difference D of both marked points Hl and H3 on wall A is the actual deviation of the instrument for the measured axis.
- The value of D (deviation) should be less than 1/4-in (6mm).
Warranty
The laser tool passed a rigorous and comprehensive product inspection. We are confident in the quality of our products and provide excellent guarantees for professional users of the products.
We offer One Year Warranty from the date of purchase including that:
- Proof of purchase is produced
- Service/repairs have not been attempted by unauthorized persons
- The product has not been misused Defective products will be repaired or replaced, free of charge or at our discretion, if sent together with proof of purchase to our authorized distributor(s).
This Warranty does not cover:
- Faults caused by accidental damage
- The product has suffered unreasonable wear and tear
- Failure to use according to manufacturers’ instructions
- Defects caused by maintenance or renovation without our authorization
- Calibration and maintenance are not included in the warranty
Note :
- We are not liable for any direct or indirect loss caused by the failure of this product beyond the scope stipulated by law.
- Repair or replacement under this Warranty does not affect the expiry date of the Warranty.
- This warranty is only applied to customers who have purchased this product, and is not permitted to transfer this warranty to any third parties.
- This Warranty shall not be altered without our authorization.
You can enjoy 12 months limited warranty but it can be up to 24 months if you
register as a member through the product registration. Please scan the QR
code to activate your priority.
If you encounter any questions or confusion about the product, please feel
free to contact us:
support@huepar.com
Changzhou Levelsure Optoelectronics Technology Co.,Ltd.
E-mail: support@huepar.com
Made in China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>