SILVERCREST SFM 2400 A1 Ergonomic Wireless Mouse Instruction Manual

June 3, 2024
SILVERCREST

SILVERCREST SFM 2400 A1 Ergonomic Wireless Mouse

SILVERCREST-SFM-2400-A1-Ergonomic-Wireless-Mouse-
product

Warnings and symbols used

The symbols shown are used in the operating instructions, on the packaging and on the unit.

  • DANGER! This symbol with the signal word “DANGER“ indicates a hazard with a high level of risk which, if not avoided, will result in serious injury or death.

  • WARNING! This symbol with the signal word “WARNING“ indicates a hazard with a medium level of risk which, if not avoided, could result in serious injury or death.

  • CAUTION! This symbol with the signal word “CAUTION“ indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

  • ATTENTION! This symbol with the signal word “ATTENTION“ indicates a possible property damage.

  • NOTE: This symbol with the signal word
    “NOTE“ provides additional useful information.

  • Direct current / voltage

  • Warning against optical radiation

  • This action sign indicates to wear suitable protective gloves! Follow the instructions to avoid hands striking or being struck by objects or being in contact with thermal or chemical materials!

  • WARNING! EXPLOSION HAZARD!
    A warning with this symbol and word
    “WARNING! EXPLOSION HAZARD” indicates the potential threat of explosion. Failure to observe this warning may result in serious or fatal injuries and potential property damage. Follow the instructions in this warning to prevent serious injuries, a danger to life or property damage!

ERGONOMIC WIRELESS MOUSE

Introduction

We congratulate you on the purchase of your new product. You have chosen a high quality product. The instructions for use are part of the product. They contain important information concerning safety, use and disposal. Before using the product, please familiarise yourself with all of the safety information and instructions for use. Only use the product as described and for the specified applications. If you pass the product on to anyone else, please ensure that you also pass on all the documentation with it.

Intended use

This ERGONOMIC WIRELESS MOUSE (hereinafter referred to as “product”)is an information technology device and is designed as an input device for computers. This product is not intended for use in companies or for other commercial uses (e.g. office productivity applications). Use this product only in the home for private purposes Any other use is considered improper. Any claims resulting from improper use or due to unauthorised modification of the product will be considered un-warranted. Any such use is at your own risk.

Trademark notices

  • USB® is a registered trademark of USB Implementers Forum, Inc.
  • Windows® is a registered trademark of Microsoft Corporation in the United States and other countries.
  • Mac OS is trademarks of Apple Inc., registered in the U.S. and other countries.
  • The SilverCrest trademark and trade name is the property of their respective owners.
  • Any other names and products are trademarks or registered trademarks of their respective owners.

Scope of delivery

Note: refer to fold out page (Fig. B)SILVERCREST-SFM-2400-A1-Ergonomic-
Wireless-Mouse-fig 2
1 Ergonomic wireless mouse
1 USB dongle
1 CD-ROM installation software
2 Batteries (AA)
1 Instructions for use

Safety notes

Before using the product, please familiarize yourself with all of the safety instructions and instructions for use! When passing this product on to others, please also include all the documents!

WARNING! DANGER TO LIFE AND RISK OF ACCIDENT FOR INFANTS AND CHILDREN!
DANGER! RISK OF SUFFOCATION! Never leave children unsupervised with the packaging material. The packaging material poses a suffocation hazard. Children frequently underestimate the dangers. The packaging material is not a toy.
This product may be used by children age 8 years and up, as well as by persons with reduced physical, sensory or mental capacities or lacking experience and/or knowledge, so long as they are supervised or instructed in the safe use of the product and understand the associated risks. Do not allow children to play with the product. Cleaning and user maintenance should not be performed by children without supervision. The product is not a toy.
DANGER! Some of the provided parts can be swallowed. If a part is swallowed, seek immediate medical attention.

WARNING! Radio interference

  • Switch the product off on aeroplanes, in hospitals, service rooms, or near medical electronic systems. The wireless signals transmitted could impact the functionality of sensitive electronics.
  • Keep the product at least 20 cm from pacemakers or implantable cardioverter defibrillators, as the electromagnetic radiation may impair the functionality of pacemakers.
  • The radio waves transmitted could cause interference in hearing aids.
  • Do not place the product near flammable gasses or potentially explosives areas (e.g. paint shops) with the wireless components on, as the radio waves emitted can cause explosions and fire.
  • The range of the radio waves varies by environmental conditions. In the event of wireless data transmission, unauthorised third parties receiving the data cannot be excluded.

DANGER! Keep batteries out of reach of children. If accidentally swallowed seek immediate medical attention.

  • Swallowing may lead to burns, perforation of soft tissue, and death. Severe burns can occur within 2 hours of ingestion.

WARNING! EXPLOSION HAZARD!

Never recharge non-rechargeable batteries. Do not short-circuit batteries or open them. Overheating, fire or bursting can be the result. Never throw batteries into fire or water. Do not exert mechanical loads to batteries.

Risk of batteries leakage

Avoid extreme environmental conditions and temperatures, which could affect batteries, e.g. radiators / direct sunlight.
In the event of a leakage of batteries, immediately remove them from the product to prevent damage.
Avoid contact of leaked chemicals with skin, eyes and mucous membranes. In the event of contact with battery acid, thoroughly flush the affected area with plenty of clean water and seek immediate medical attention.

WEAR PROTECTIVE GLOVES!

Leaked or damaged batteries can cause burns on contact with the skin. Wear suitable protective gloves at all times if such an event occurs.

Battery

  • Both batteries must always be replaced at the same time.
  • Insert batteries according to polarity marks (+) and (-) on the battery and the product.
  • Never try to recharge the batteries and under no circumstances throw them into fire.
  • Use a dry lint-free cloth or cotton swab to clean the contacts on the battery / rechargeable battery and in the battery compartment before inserting!
  • Remove exhausted batteries from the product immediately.
  • Only use the specified type of battery!
  • Remove the battery when the product is not to be used for a long time.
  • Improper use may cause explosions and danger to life.

ATTENTION! RISK OF PROPERTY DAMAGE

  • Check the product before every use! Discontinue use if any damage to the product is detected!
  • Sudden temperature changes may cause condensation inside the product. In this case, allow the product to acclimate for some time before using it again to prevent short circuits!
  • Do not operate the product near heat sources, e.g. radiators or other devices emitting heat!
  • Do not throw the product into fire and do not expose to high temperatures.
  • Never open the product!! It has no internal parts requiring maintenance.

ATTENTION! Ensure that no direct heat sources (e.g. heating) can affect the product

  • any contact with splashed and dripping water and corrosive liquids is avoided and the product is not operated in the vicinity of water. In particular, the product should never be submerged in liquid; do not place any vessels filled with liquid, for example, vases or drinks, on or near the product.
  • the product is not used in the immediate vicinity of magnetic fields (e.g. speakers).
  • no fire sources (e.g. burning candles) are placed on or near the product.
  • no objects are inserted into the interior of the product.
  • the product is never subjected to excessive shocks and vibrations.

Do not look directly into the light beam. Also, do not look at the light beam with optical devices.

NOTE:

The user must take regular breaks during the use of the product, in case of pain in the hands, arms or shoulder and neck area the work must be interrupted and some stretching exercises must be done.

  • The OWIM GmbH & Co KG is not responsible for interference with radios or televisions due to unauthorised modification of the product.
  • The user of the product is fully responsible for correcting interference caused by such unauthorised modification of the product, as well as replacement of such products.
  • It is necessary to repair the product if they have been damaged in any way, for example, if the housing is damaged, if liquid or objects have penetrated the product or if the product has been exposed to rain or moisture.
  • Repair work is also required if the product is not working properly or has been dropped. If smoke is produced, or there are any unusual sounds or smells, turn the product off immediately and remove the batteries. In such cases, the product should not be used until they have been inspected by authorised service personnel. Only have the product repaired by qualified personnel. Never open the housing of the product.

Description of parts

Please refer to the fold out page.

  1. Right mouse button
  2. DPI button
  3. LED indicator for low battery and DPI status 4 Backward button
  4. Forward button
  5. Left mouse button
  6. Scroll wheel and middle mouse button
  7. Battery compartment cover
  8. Instructions for use
  9. USB dongle
  10. Software CD
  11. 2 x AA batteries
  12. On/Off Switch

Technical data

  • Voltage supply: 2 x 1.5 V, AA batteries
  • Operation time: 3 to 6 months (Alkaline battery)
  • Operating Systems: Windows® 7 / 8 / 10
  • Resolution: 800 / 1600 / 2400 dpi
  • Range: 10 m
  • Radio frequency band: 2408 – 2474 MHz
  • Max. transmitted power: 0.72 mW
  • USB version: 2.0
  • Hardware requirement:: 1 free USB port
  • Operating temperature: 5 to 35 °C
  • Storage temperature: 0 to 45 °C
  • Storage humidity: 10 to 70 % RH
  • Dimension (L x W x H): approx. 118 x 90 x 52 mm
  • Net weight: approx. 90 g (without battery)

The specification and design may be changed without notification

Before use

NOTE:

  • Before use, verify the package contents are complete and undamaged!
  • All parts have to be unpacked and the packaging material has to be removed completely.

Setting up your mouse – inserting/replacing the battery (see fig. C )SILVERCREST-SFM-2400-A1-Ergonomic-Wireless-Mouse-fig
3

  • Remove the battery compartment cover 8 .
  • Insert 2 AA batteries 12 into the battery compartment .
  • Ensure that the polarities are correct (+/–).
  • Reinsert the battery compartment cover 8 and push it down until it locks in place.

Operation

  1. Connecting the USB dongle 10 (see fig. D): Slot the USB dongle 10 into a spare USB port on your computer.SILVERCREST-SFM-2400-A1-Ergonomic-Wireless-Mouse-fig 4
  2. Slide the ON/OFF button 13 to the “ON” position in order to turn on the mouse.
  3. Turn your computer on.
  4. The necessary drivers are automatically installed.

**Function of buttons

SILVERCREST-SFM-2400-A1-Ergonomic-Wireless-Mouse-
fig 1**

  1. Right mouse button: Provides traditional mouse click functions.

  2. DPI button: (800 / 1600 / 2400 – Click button once, then change DPI setting to next DPI value). The default DPI setting is 1600 dpi. Choose a setting that is comfortable for you.

  3. Backward button

  4. Forward button

  5. Left mouse button: Provides traditional mouse functions
    like click, double click and drag.

  6. Scroll wheel and middle mouse button: Roll up or down to scroll through pages or documents.
    LED indicator for low battery and DPI status 3

  7. When battery power is low, the LED indicator will light up in red, please replace the batteries with new batteries.

  8. Press DPI button to change its DPI level. The LED indicator will flash according to its DPI level:

  * Flash 1 x = 800 DPI
  * Flash 2 x = 1600 DPI
  * Flash 3 x = 2400 DPI

Software installation

NOTE:
The software is not compatible with MAC OS.
You can also download the mouse installation software at www.Lidl- service.com. At this Lidl service website you have to input the product number IAN 373971_2104 to search for the software to download.

Software installation from CD

  1. Insert the provided Setup Disc into the computer’s CD rom.
  2. The installation process should start automatically.
  3. If this is not the case, start the file “SFM 2400 A1 Mouse Setup.exe“ manually on the CD-ROM by double-clicking.
  4. Follow the installation instructions to complete the whole installation process.
  5. After installing and running the application software program, you will find the below user interface.SILVERCREST-SFM-2400-A1-Ergonomic-Wireless-Mouse-fig 5

Configuration of wireless mouse function

The software is used to configure the mouse buttons. The software is divided into three tabs:
Button Assign/ Sensitivity/ Support. Please refer to below for more details.

Button Assign tab:

  • You can program the buttons of the mouse with different functions. Just simply click on the button that you wish and a function list will pop out for selection. Once you have selected your preferred function on the list click “Apply“, and the assigned mouse function will now be ready to use.

Sensitivity tab

Option Description
CPI1/ CPI2/ There are 3 optical resolution of wireles mouse that you can update and preset in this software menu.
CPI3SILVERCREST-SFM-2400-A1-Ergonomic-Wireless-Mouse-fig
5

Option Description

  • Acceleration You can set your preferred mouse cursor speed (0 – 10). Click “Accuracy Increasing“ box to achieve a better accuracy of wireless mouse .
  • Vertical Scrolling   Speed This setting allows you to change the scroll speed of the wireless mouse (0 – 10).
  • Double Click Speed This setting allows you to adjust how fast the left button pressed in a row that double click is triggered.
  • Polling rate The higher the data transfer rate, the more often your computer receives information about the status of your mouse. You can select among 125 Hz, 250 Hz, 500 Hz and 1000 Hz.

Support tab:
This tab shows the software version.

Profile (1- 5):
There are total 5 profile that you can preset and optimize to your favor setting via this software. Also you can save/ load profile into/out of this software anytime when you need.

Restore to default:
You can reset all setting to factory default setting by clicking “Restore to default“ and then press “Apply“.

Storage when not in use

Batteries must be removed before storage.
Store the product in a dry indoor location protected from direct sunlight, preferably in its original packaging.

Cleaning

Switch the product off before cleaning!
No acid, chafing or solvent cleaning agents should be used or the product can be damaged.
Only clean the outside of the product using a soft, dry cloth! At persistent soiling, a mild cleaning agent can be used.

Troubleshooting

Problem Solution

The product does not work properly.

  • Option 1: Check if the battery is properly fitted.
  • Option 2: The battery needs to be replaced by a new one.
  • Option 3: Remove any other mouse connected to your computer and reconnect your mouse.
  • Option 4: Avoid using this product onto transparent or reflective surfaces.
  • Option 5: USB dongle not correctly inserted, try another free USB port or reboot your computer.
  • Option 6: Dirts stained onto optics of mouse, please clean the dirts and try again.

Disposal

Packaging:

The packaging is made of environmentally friendly materials, which may be disposed of through your local recycling facilities.
Observe the marking of the packaging materials for waste separation, which are marked with abbreviations (a) and numbers (b) with following meaning: 1–7: plastics / 20–22: paper and fibreboard / 80–98: composite materials.

Product:

Contact your municipality for information on how to dispose of your worn-out product.
The adjacent symbol of a crossed out dustbin on wheels indicates this product is subject to Directive 2012/19/EU. This directive states at the end of the life this product must not be disposed of through regular household refuse but must be returned to special collection sites, recycling depots or waste management companies.
This disposal is free of charge to you.
Protect the environment and dispose of properly.
The product is recyclable, subject to extended manufacturer responsibility, and collected separately.an be obtained from your local authority.

Batteries:

Think about the environment and your personal health. Dispose empty batteries in separate collecting boxes. These can be found in many public buildings or in shops where batteries are sold.

Improper disposal of batteries can harm the environment!

Never dispose of batteries in your household waste. They may contain toxic heavy metals and are subject to hazardous waste regulations. The chemical symbols of the heavy metals are: Cd = cadmium, Hg = mercury, Pb = lead. Therefore dispose of used batteries through your local collection site.

Simplified EU declaration of conformity

Hereby, OWIM GmbH & Co. KG, Stiftsbergstraße 1,
74167 Neckarsulm, GERMANY, declares that the product [ERGONOMIC WIRELESS MOUSE, HG05319A], is in compliance with Directives 2014/53/EU and 2011/65/EU.
The full text of the EU declaration of conformity is available at the following internet address: www.owim.com

Warranty and service

Warranty

  • The product has been manufactured to strict quality guidelines and meticulously examined before delivery. In the event of product defects you have legal rights against the retailer of this product. Your legal rights are not limited in any way by our warranty detailed below.
  • The warranty for this product is 3 years from the date of purchase. The warranty period begins on the date of purchase. Please keep the original sales receipt in a safe location. This document is required as your proof of purchase.
  • Should this product show any fault in materials or manufacture within 3 years from the date of purchase, we will repair or replace it – at our choice – free of charge to you.
  • This warranty becomes void if the product has been damaged, or used or maintained improperly.
  • The warranty applies to defects in material or manufacture. This warranty does not cover product parts subject to normal wear, thus possibly considered consumables (e.g. batteries) or for damage to fragile parts, e.g. switches, rechargeable batteries or glass parts.

Warranty claim procedure

To ensure quick processing of your case, please observe the following instructions:
Please have the till receipt and the item number
(IAN 373971_2104) available as proof of purchase.
You will find the item number on the rating plate, an engraving, on the front page of the instructions for use (bottom left), or as a sticker on the rear or bottom of the product.
If functional or other defects occur, please contact the service department listed either by telephone or by e-mail.
You can return a defective product to us free of charge to the service address that will be provided to you. Ensure that you enclose the proof of purchase (till receipt) and information about what the defect is and when it occurred.

Service

Service Great Britain

Tel.: 08000569216
E-Mail: owim@lidl.co.uk

Service Cyprus

Tel.: 8009 4211
E-Mail: owim@lidl.com.cy

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals